12-1372-014FORM 405-10
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Palmcorp Development Group Lot 3
Builder Name:
Street: 6724 Magnolia Court
Permit Office: South Miami
City, State, Zip: South Miami, FL, 33143-
Permit Number:
Owner: Palmcorp Development Group
Jurisdiction: 233300
Design Location: FL, Miami
I. New construction or existing New (From Plans)
9. Wall Types (3518.2 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a- Concrete Block - Int Insul, Exterior
R=4.1 3274.30 fta
3. Number of units, if multiple family 1
b. Frame - Steel, Adjacent
c. N/A
R=11.0 243.83 ft'
R= ft2
4. Number. of Bedrooms 4
d. N/A
R= ft2
5. Is this a worst case? No
10. Ceiling Types (1440.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=19.0 1440.00 ft:,
6. Conditioned floor area above grade (ft2) 2649
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
7. Windows(437.7 sqft.) Description Area
11. Ducts
a. Sup: Attic, Ret: 1st Floor, AH: 1st Floor
R ft2
6 260
a. U -Factor: Dbl, U=0.87 437.68 ft2
b. Sup: Attic, Ret: 2nd Floor, AH: 2nd
Floor 6 310
SHGC: SHGC=0.50
b. U -Factor: N/A ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
29.6 SEER:16.00
c. U -Factor. N/A fta
b. Central Unit
29.6 SEER:16.00
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U -Factor: N/A fta
a. Electric Strip Heat
17.0 COP -1,00
SHGC:
b. Electric Strip Heat
25.5 COP -1-00
Area Weighted Average Overhang Depth: 3.836 ft.
Area Weighted Average SHGC: 0.5Q0
14. Hot water systems
8. FloarTypes (1440.0 sqft.) Insulation Area
a. Electric Tankless
Cap: 1 gallons
a. Slab -On -Grade Edge Insulation R=0.0 1209,00 ft2
b. Conservation features
EF: 1.033
b. Raised Floor R=0.0 231.00 ft'
None
c. N/A R= ft2
15. Credits
Pstat
Glass/Floor Area: 0.165 Total Proposed Modified Loads: 67.91
����
Total Standard Reference Loads: 84.64
I hereby certify that the plans and specifications covered by
Review of the plans and
rr' f.- r
vl� S,
this calculation are in compliance with the Florida Energy
Code.
-
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
'�+�r',,,, fr ��`C,•�
'gyp
PREPARE BY:�'
DATE:' /
�� �_ _
Before construction is completed
this building will be inspected for
compliance with,Section 553.908
` �F,
-.�,� .
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
t. .
,. T
with the Florida Energy Code.
OWNER/AGENT: __ _.. -
BUILDING OFFICIAL:
DATE: _ -- -
DATE:
- Compliance Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist
- Heat sys #1 may be undersized. Size of 17.0 was increased to 18.5 for simulation. Please review the Manual J8 report.- Cool sys
#1 may be undersized. Size of 29.6 was increased to 29.6 for simulation. Please review the Manual J8 report.- Cool sys #2 may be
undersized. Size of 29.6 was increased to 29.6 for simulation. Please review the Manual J8 report.
9/18/2012 8:51 PM EnergyGauge@ USA - FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 6