12-1372-007ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 80
The lower the Energy Performance Index, the more efficient the home.
6724 Magnolia Court, South Miami, FL, 33143-
1. New construction or existing
New (From Plans)
9. Wall Types
Insulation
Area
a. Concrete Block - Int Insul, Exterior
R=4.1
3274.30 ft2
2. Single family or multiple family
Single-family
b. Frame - Steel, Adjacent
R=11.0
243.83 ft
3. Number of units, if multiple family
1
c. N/A
R=
ft2
4. Number of Bedrooms
4
d. N/A
R=
ft2
10. Ceiling Types
Insulation
Area
5. Is this a worst case?
No
a. Under Attic (Vented)
R=19.0
1440.00 ft2
6. Conditioned floor area (ft2)
2649
b. N/A
R=
ft2
c. N/A
R=
ft2
7. Windows" Description
Area
11. Ducts
R ft 2
a. U -Factor: Dbl, U=0.87
437.68 ft2
a. Sup: Attic, Ret: 1st Floor, AH: 1st Floor
6 260
SHGC: SHGC=0.50
b. Sup: Attic, Ret: 2nd Floor, AH: 2nd Floor
6 310
b. U -Factor: N/A
ft2
SHGC:
12. Cooling systems
kBtu/hr
Efficiency
c. U -Factor: N/A
ft2
a. Central Unit
29.6 SEER:16.00
SHGC:
b. Central Unit
29.6 SEER:16.00
d. U -Factor: N/A
ft2
13. Heating systems
kBtu/hr
Efficiency
SHGC:
a. Electric Strip Heat
17.0
COP:1.00
Area Weighted Average Overhang Depth:
3.836 ft.
b. Electric Strip Heat
25.5
COP:1.00
Area Weighted Average SHGC:
0.500
8. Floor Types
Insulation
Area
14. Hot water systems
Cap:
1 gallons
a. Slab -On -Grade Edge Insulation
R=0.0
1209.00 ft2
a. Electric
EF: 0.95
b. Raised Floor
R=0.0
231.00 ft2
b. Conservation features
c. N/A
R=
ft2
None
15. Credits
Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature:
Address of New Home:
Date:
City/FL Zip:
-VVIE ST
7
f W
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's
support staff.
**Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software