12-1372-001L�
FORM 405-10
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONS TION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Palmcorp Development Group Lot 3
Builder Name:
Street: 6724 Magnolia Court
Permit Office: South Miami
City, State, Zip: South Miami , FL , 33143-
Permit Number:
Owner: Palmcorp Development Group
Jurisdiction: 233300
Design Location: FL, Miami
1. New construction or existing New (From Plans)
9. Wall Types (35182 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 3274.30 ft2
b. Frame - Steel, Adjacent
R=11.0 243.83 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 4
d. N/A
R= ft2
5. Is this a worst case? No
10. Ceiling Types (1440.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=19.0 1440.00 ft2
6. Conditioned floor area above grade (ft2) 2649
b. N/A
R= ft2
Conditioned floor area below grade (W) 0
c. N/A
R= ft2
11. Ducts
R ft2
,7. Windows(437.7 sqft.) Description Area
a. Sup: Attic, Ret: 1st Floor, AH: 1st Floor 6 260
a. U -Factor: Dbl, U=0.87 437.68 ft2
b. Sup: Attic, Ret: 2nd Floor, AH: 2nd
Floor 6 310
SHGC: SHGC=0.50
b. U -Factor: N/A ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
29.6 SEER:16.00
c. U -Factor: N/A ft2
b. Central Unit
29.6 SEER:16.00
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U -Factor: N/A ft2
a. Electric Strip Heat
17.0 COP:1.00
SHGC:
b. Electric Strip Heat
25.5 COP:1.00
Area Weighted Average Overhang Depth: 3.836 ft.
Area Weighted Average SHGC: 0.500
14. Hot water systems
8. Floor Types (1440.0 sqft.) Insulation Area
a. Electric Tankless
Cap: 1 gallons
a. Slab -On -Grade Edge Insulation i.; R=0.0 1209.00 ft2
b. Conservation features
EF: 1.033
b. Raised Floor q �� r a xs� R=0.0 231.00 W
None
a N/A '` h R_ ft2
15. Credits
Pstat
u Total Proposed Modified Loads: 67.91
Glass/Floor Area xf 61
PASS
'6� , .. ,
. , Total Standard Reference Loads: 84.64
Q
hereby certifyrt'at the`pla and spe)ificakions covered by
Review of the plans andkt
5 "
this calculation are m com110n e- with the Florida Energy
specifications covered by this
{
Code. i „s
calculation indicates compliance��r
with the Florida Energy Code.
PREPARED
/~�
Before construction is completed'
..
..
DATE:
this building will be inspected for
is f
bgtai7c�tg `as
compliance with Section 553.908
Florida Statutes.
hereby certify that this designed, is in compliance
with the Florida Energy Gode'. i,WIF
OWNER/AGENT.
BUILDING OFFICIAL:
DATE:
DATE:
Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist
- Heat Sys #1 may be undersized. Size of 17.0 was increased to 18.5 for simulation. Please review the Manual J8 report.- Cool Sys
41 may be undersized. Size of 29.6 was increased to 29.6 for simulation. Please review the Manual J8 report.- Cool Sys #2 may be
undersized. Size of 29.6 was increased to 29.6 for simulation. Please review the Manual J8 report.
09 ID
\16
9/18/2012 8:51 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 6