12-1372-001L� FORM 405-10 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONS TION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Palmcorp Development Group Lot 3 Builder Name: Street: 6724 Magnolia Court Permit Office: South Miami City, State, Zip: South Miami , FL , 33143- Permit Number: Owner: Palmcorp Development Group Jurisdiction: 233300 Design Location: FL, Miami 1. New construction or existing New (From Plans) 9. Wall Types (35182 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 3274.30 ft2 b. Frame - Steel, Adjacent R=11.0 243.83 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (1440.0 sqft.) Insulation Area a. Under Attic (Vented) R=19.0 1440.00 ft2 6. Conditioned floor area above grade (ft2) 2649 b. N/A R= ft2 Conditioned floor area below grade (W) 0 c. N/A R= ft2 11. Ducts R ft2 ,7. Windows(437.7 sqft.) Description Area a. Sup: Attic, Ret: 1st Floor, AH: 1st Floor 6 260 a. U -Factor: Dbl, U=0.87 437.68 ft2 b. Sup: Attic, Ret: 2nd Floor, AH: 2nd Floor 6 310 SHGC: SHGC=0.50 b. U -Factor: N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 29.6 SEER:16.00 c. U -Factor: N/A ft2 b. Central Unit 29.6 SEER:16.00 SHGC: 13. Heating systems kBtu/hr Efficiency d. U -Factor: N/A ft2 a. Electric Strip Heat 17.0 COP:1.00 SHGC: b. Electric Strip Heat 25.5 COP:1.00 Area Weighted Average Overhang Depth: 3.836 ft. Area Weighted Average SHGC: 0.500 14. Hot water systems 8. Floor Types (1440.0 sqft.) Insulation Area a. Electric Tankless Cap: 1 gallons a. Slab -On -Grade Edge Insulation i.; R=0.0 1209.00 ft2 b. Conservation features EF: 1.033 b. Raised Floor q �� r a xs� R=0.0 231.00 W None a N/A '` h R_ ft2 15. Credits Pstat u Total Proposed Modified Loads: 67.91 Glass/Floor Area xf 61 PASS '6� , .. , . , Total Standard Reference Loads: 84.64 Q hereby certifyrt'at the`pla and spe)ificakions covered by Review of the plans andkt 5 " this calculation are m com110n e- with the Florida Energy specifications covered by this { Code. i „s calculation indicates compliance��r with the Florida Energy Code. PREPARED /~� Before construction is completed' .. .. DATE: this building will be inspected for is f bgtai7c�tg `as compliance with Section 553.908 Florida Statutes. hereby certify that this designed, is in compliance with the Florida Energy Gode'. i,WIF OWNER/AGENT. BUILDING OFFICIAL: DATE: DATE: Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist - Heat Sys #1 may be undersized. Size of 17.0 was increased to 18.5 for simulation. Please review the Manual J8 report.- Cool Sys 41 may be undersized. Size of 29.6 was increased to 29.6 for simulation. Please review the Manual J8 report.- Cool Sys #2 may be undersized. Size of 29.6 was increased to 29.6 for simulation. Please review the Manual J8 report. 09 ID \16 9/18/2012 8:51 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 6