12-1371-022HANGERS AND SUPPORTS 5TANDARD 5" WIDE HANGER5 HANGER EXTENSION TO BE THE SUM OF THE DISTANCES BETWEEN THE HANGING WIRES AND THE DUCT 51ZE, ID (5MACNA) DUCT SIZE, INCHES MAXIMUN HANGER MINIMUN CHANNEL PROFILE 5PAG I NG 48: WIDE OR WRATER 4 FT. LESS THAN 45" WIDE 6 FT. AND LESS THAN 45" 50" DEEP 3 "X2 " WIDTH BETWEEN 28" 6 FT. 48" AND GREATER FIRE RATED ROOF CEILING ASSEMBLY THAN 16" DEEP X LESS THAN 2al" WIDE 8 FT. AND 16" DEPTH OR LESS SMOKE CONTROL CHANNEL 5EGT ION IF TOTAL EXTENSION 15 NOT GREATER THAN: MINIMUN CHANNEL GAUGE MINIMUN CHANNEL PROFILE 6" 24 311X1.5" 18" 22 311X2" 50" 18 3 "X2 " 22 GAUGE 2'X1.5" HANGER MAY BE SUBSTITUTED FOR 3" HANGER FOR DUCTS WITH WIDTHS NOT OVER 48" AND DEPTHS NOT OVER 24" PROVIDED THAT NOT MORE THAN ONE JOINT OCCURS BETWEEN HANGER AND THAN MAXIMUM HANGER SPACING 4 FT. EXCEPTION: WHEN DUCT PERIMETER 15 80" OR LESS AND DOES NOT RF_aUIRE REINFORCEMENT TWO JOINTS ARE PERMITTED BETWEEN HANGERS. ROOF STRUCTURE SEE ARCHITECTURAL 4-16d NAILS THRU PLYWOOD 4'0 METAL DUCT 30 GAUGE MIN. FB.C. 6033 PROVIDE W/P. CAP LOW PROFILE R.D.D. AT TOP FOR BATHROOM PROVIDE CORROSION RESISTANT INSECT SCREEN —ROOFING CONTRACTOR TO SUPPLY WATER PROOFING, AS PER VENT MOUNT. DETAIL 4 RECOMMENDATION. - WALL I 50 ELBOW 4 / CAP ASSEMBLY FAN IN------,/ CEILING T-i"F I CAL ROOF G,4P DETAIL L TOILET EXH. NT& NOT BIRD SC FOR DRYER FLUE 5 1-1/2"X22 GAUGE METAL STRAP ANGHORD TO SLAB W/5PAN51ON ANCH. ® 6FT. MAX. MAX 5 FT. 5PAG I NS BETW. SUPPORT GAL. METAL STRAP SUPPORT W/METAL SCREW r ° LOW VELOG I TY FLEXIBLE DUCT FLEXIBLE DUCT SUPPORT DETAIL 4"d INSIDE DIAMETER MTL. STEEVE FOR DRYER DUCT W/CAP. FINISH WALL DRYER VENT TERMINATION DETAIL N.T.S. HVAC DESIGN REQUIRES: YES NO DUCT SMOKE DETECTOR X FIRE DAMPER(S) 0 M X SMOKE DAMPER(S) I X FIRE RATED ENCLOSURE X FIRE RATED ROOF CEILING ASSEMBLY X FIRE STOPPING w X SMOKE CONTROL C) N AIR CONDITIONING GENERAL NOTES 1. SCOPE OF WORK: A. INSTALL A COMPLETE NEW HVAC SYSTEM AS SHOWN ON DRAWINGS. 2. EQUIPMENT SHALL HAVE CAPACITIES REQUIRED TO OBTAIN A SUITABLE OPERATING BALANCE BETWEEN ASSOCIATED ITEMS OF EQUIPMENT. ALL DAMPERS AND CONTROLS SHALL BE ADJUSTED TO OSTEIN THE REQUIRED CAPACITIES UNDER ACTUAL OPERATING CONDITIONS OF EACH ITEMS OF EQUIPMENT SHALL NOT EXCEED THE RATED MOTOR HORSEPOWER. BALANCED CAPACITIES BE EQUAL TO THOSE SCHEDULED AT DESIGN CONDITIONS. 3. COOLING SYSTEM AREA DESIGNED FOR 18F D8 INSIDE CONDITIONS WITH OUTSIDE AIR TEMPERATURE OF 91F D.B. 79F W.B. HEATING IS DESIGNED TO MAINTAIN MINIMUM INSIDE TEMPERATURES OF 12F D.B. WITH AND OUTSIDE TEMPERATURE OF 45F D-5- 4. AIR DISTRIBUTION DEVICES SHALL BE CONSTRUCTED OF ALLUMINIUM, AS MANUFACTURED BY TITUS. CEILING DIFFUSER TO BE TITUS SERIES 200-F5, W/ OPPOSED BLADE DAMPER, AND SUPPLY AIR REGISTERS TO BE MODEL 2 -11 -FL EXPOSED GRILLAGE SHALL BE PAINTED OF SAME COLOR OF THE CEILING OR WALL IN WICH IT IS LOCATED IN AND ALL SCREWS SHALL BE OF THE COUNTERSUNK TYPE ALSO PAINTED AS GRILLAGE. 5. CONSTRUCT AIR CONDITIONING DUCTWORK FROM ONE INCH THICK FOR DUCTWORK THAT RUNS BETWEEN FLOORS AND ONE HALF INCH THICK FOR DUCTWORK THAT RUNS WITHIN ATTIC SPACE STANDARD WEIGHT, FIBROUS GLASS DUCTBOARD. FABRICATED, SEAL AND INSTALLED PER LATEST SMACNA FIBROUS GLASS DUCT MANUAL RECOMMENDATIONS. DUCT SIZES NOTED ARE CLEAR INSIDE DIMENSIONS PROVIDE ALL ELBOWS WITH DOUBLE THICKNESS TURNING VANES AT ALL BRANCH DUCT TAKE -OFFS AS REQUIRED FOR PROPER AIR BALANCING. 6. AIR COOLED CONDENSING UNITS TO BE AS SCHEDULE, OR APPROVED EQUAL PROVIDED EACH UNIT WITH ANTI- CYCLING DEVICE OR TIMER, HIGH AND LOW PRESSURE CONTROLLERS, AND FILTER DRIER. rt. FANCOIL UNIT TO BE AS SCHEDULE, OR APPROVED EQUAL COORDINATE WITH ELECTRICIAN TO CONNECT MULTI -SPEED FAN MOTOR TO PROPER SPEED TAPS TO DELIVER SCHEDULED AIR QUANTITIES, AGAINST SYSTEMS RESISTANCE AS INSTALLED DURING THE COOLING MODE± AND TO DELIVER MINIMUM SUPPLY AIR CFM, AS RECOMMENDED BY UNIT MANUFACTURER DURING THE HEATING MODE. 8. INSULATE REFRIGERANT SUCTION PIPE WITH 3/4 INCH THICK ARMAFLEX FINISH INSULATION EXPOSED TO WEATHER WITH TWO COATS OF GLASSFAB AND MASTIC. PROVIDE 3" PVC JACKET FOR ALL REFRIGERANT LINES UNDER GROUND FLOOR 9. COORDINATE ALL WORK WITH OTHER TRADES INVOLVED, THIS INCLUDES WALL AND ROOF PENETRATIONS AND REQUIERED ELECTRICAL SERVICE AND CONTROL WIRING. PLUMBER IS TO PROVIDE A MINIMUM 1- 1/4 INCH CONDENSATE TRAP SEAL AT EACH FANCOIL UNIT, PIPE TO OUTSIDE OF HOUSE 6' ABOVE FINISHED GRADE. 10. THERMOSTAT SHALL HAVE A MAXIMUM HEATING MODE TEMPERATURE SETTING OF -18F AND A MINIMUM COOLING MODE TEMPERATURE SETTING OF 10F. IT SHALL BE ADJUSTABLE TO PROVIDE A TEMPERATURE OF UP TO 10F BETWEEN FULL HEATING AND FULL COOLING. HEATING AND COOLING TO BE NON -CONCURRENT THERMOSTAT TO HAVE REQUIRED STAGES OF COOLING AND HEATING FOR COMPATIBILITY WITH AIR CONDITIONING EQUIPMENT PROVIDE. 11. THE AIR FLOW AT EACH SUPPLY OUTLET SHOWN ARE PRELIMINARY AND FINAL FLOW AT EACH OUTLET SHALL BE DETERMINED BY DEGREE OF COMFORT TEMPERATURE. EXHAUST FAN SCHEDULE EF -1 SHALL BE GROAN MODEL N.- II a 120WI PH/60 HZ. 1/4' SP 50 CFM W/BACKDRAFT DAMPER EF -2 SHALL BE GROAN MODEL N.- 360 m 120WI PH/60 HZ. 1/4' SP 110 CFM W/BACKDRAFT PAMPER PROVIDE SAFETY FLOAT SAITGH DEVICE 2" COND. DRAIN — UNDERSROUND.. (SEE A/C FL.PLAN FOR TERMINATION) RA OPENING \I SUPPLY r�kirc'OUCT O R-6 MIN. INSULATION 6„ DISCONNECT SWITCH AIR J HANDLER LIGUID LINE TO G. U. UNIT o SUCTION LINE TO G. U. AIR HANDLING UNIT AIR CONDITIONING CLOSET NOTE: A/C COMPRESSOR UNIT SHALL BE MOUNTING 1.0 FT. ABOVE OF BASE FLOOD ELEVATION. 1 CONDENS IN X UNIT 6' min. 6" MIN. ... 1/2' ANCHOR BOLT BY 2' EA. CORNER W/2 BY 1/8' L WELDED. A/C COMP SHALL BE INTALLED ABOVE BASE FLOOD ELEVATION 6' MIN. CONCRETE BASE 6 F.F.E. 10.00 N.G.V.D. LIQUID AND SUCTION LIN W/ 6X6 - 10/10 WWF W INSULATI N METAL SUPPORT (SELF -STANDING) METAL BAND 1-1/2' 20 GA. TYP AROUND COND. UNIT AS SHOWN NTS POWER 4 CONTROL CONNECTIONS O o SEAL ENTRANCE OF REFRIGERANT LINES INTO P.V.C. PIPE W/ IMPERMEABLE, RESILENT MATERIAL 4' SCHEDULE 40 P.V_C. PIPE /O O SUCTION LINE W/1-1/2" ARMAFLEX INSULATION 4 VAPOR BARRIER CONDENSING UNIT MOUNTAING DETAIL N.T.S. METAL ROUND FITTING QUADRANT OPERATOR TO BE OUTSIDE INSULATION PROVIDE INSULATION GUARD LUHERE NECESSARY PROVIDE FIBERGLASS INSULATION SEAL TO NECK 4 PERIMETER OF DIFFUSER DIFFUSER OR REGISTER SEAL JOINT WITH DUCT SEALER AND TAPE R-6 MIN. INSULATION INSULATED FLEX. DUCT R-6 MIN. INSULATION SEAL JOINT WITH DUCT SEALER AND TAPE `-- R-6 MIN. INSULATION FLEXIBLE DUCT CONNECTION DETAIL N.T.S. �L. CONDENSATE WATER DISCHARGE SCALE- N.T.S. LOT 5 o_ 0 L CD c 0 CL 0 cu 0- 0 c.� E 1, ; ... .� 0U� ( a p LL 0 M M dd I LL_ .E w r "tirt C) N (T3 c L zco CDLCD JoU) v o O Q O LjL ® U w cC3 J 0 C Ez <[ w �- d- c0: <; � _ O o_ 0 L CD c 0 CL 0 cu 0- 0 c.� E REVISIONS L- 2- 3,- 4.- 6. - DATE *EPTEMBER, 2012 SCALP; SHOWN DRAWN- M. CASTELLON DENGN By. JR JOB NOc M-2 1, ; ... .� 0U� ( a p LL Z M dd I LL_ .E w r "tirt C) (T3 c JoU) Q O LjL ® U w cC3 J 0 C w �- d- REVISIONS L- 2- 3,- 4.- 6. - DATE *EPTEMBER, 2012 SCALP; SHOWN DRAWN- M. CASTELLON DENGN By. JR JOB NOc M-2 1, ; ... .� ( a p dd I "tirt F j"p REVISIONS L- 2- 3,- 4.- 6. - DATE *EPTEMBER, 2012 SCALP; SHOWN DRAWN- M. CASTELLON DENGN By. JR JOB NOc M-2