Loading...
06-1811-020TYPE: SQUARE 'D' QD (OR EQUAL) PANE A (TYPICAL) MAIN: 200 A VOLTAGE: 120/240 V. lm 3W. (ALL 20 AMPS, 1 POLE GKtS. EXCEPT AS NOTED) FEEDER: 3"3/0 THW-CU MOUNTING: FLUSH CONDUIT: 1-1/2' Lu O O } REMARKS 6 z U Y REMARKS N z U REMARKS O U Q LL O > O 91 2 5060 (••) 15 I 159i50 1/2' 12 GENERAL LIGHTING 1 3/4' 2 GENERAL LIGHTING 12 1/2' 1 15 15 I 1/2' 12 GENERAL LIGHTING 3 4 GENERAL LIGHTING 12 1/2' 1 15 15 I 2 60 1/2' 12 GENERAL LIGHTING 5 6 GENERAL LIGHTING 12 1/2' 1 15 15 1 0 1/2' 12 GENERAL LIGHTING 10 GENERAL LIGHTING 8 RECEPTACLE 12 1/2' • 1 20 20 1 a 1/2' 12 RECEPTACLE 9 10 RECEPTACLE 12 1/2' 1 20 20 1 0 1/2' 12 RECEPTACLE 11 12 RECEPTACLE 12 1/2' 1 20 20 1 a 1/2' 12 RECEPTACLE 13 14 RECEPTACLE 12 1/2' 1 20 20 1 0 1/2' 12 RECEPTACLE 15 16 RECEPTACLE 12 1/2' 1 20 20 1 s 1/2' 12 G.F.I. BATH RECEPT. 1T 18 SMOKE DETECTORS 12 1/2' 1 20 20 I 1 1500 1/2' 12 SMALL APPLIANCES 19 20 SMALL APPLIANCES 12 1/2' 1500 1 20 20 1 1500 1/2' 12 SMALL APPLIANCES 21 22 SMALL APPLIANCES 12 1/2' 1500 1 20 20 1 1500 1/2' 12 SMALL APPLIANCES 23 24 SMALL APPLIANCES 12 1/2' 1500 1 20 20 1 1500 1/2' 12 SMALL APPLIANCES 25 26 SMALL APPLIANCES 12 1/2' 1500 1 20 20 1 1500 1/2' 12 SMALL APPLIANCES 21 28 SMALL APPLIANCES 12 1/2' 1500 1 20 20 1 1500 1/2' 12 SMALL APPLIANCES 29 30 REFRIGERATOR 12 1/2' 1500 1 20 50 2 12000 3/4' 306 OVEN/RANGE 31 32 DISHWASHER 12 1/2' 1500 1 20 41 42 33 34 DISPOSAL 12 1/2' 1 1500 1 20 30 2 5000 3/4' 2"8 t DRYER 35-]36 DOOR MOTOR 12 1/2' 1 1500 1 20 1"90 31 38 DOOR MOTOR 12 1/2' 1500 1 20 20 1 1500 1/2' 12 WASHER 39 40 POOL MOTOR 12 1/2' 1500 1 20 20 1 1500 I/2' 12 HOOD W/ EXHAUST 41 42 CONNECTED LOAD:SEE LOAD CALCULATION FEEDER:SEE RISER (AIC RATING 22,000 AMPS) FED FROM:SERVICE NOTE: ALL BEDROOM AND SMOKE DETECTOR CIRCUITS TO BE ARC FAULT PROTECTED TYPE: SQUARE 'D' QD (OR EQUAL) I AN E L V (TYPICAL) MAIN: 150 A VOLTAGE: 120/240 V. 10 3W. FEEDER: 301/0 THW-CU MOUNTING: FLUSH (ALL 20 AMPS, 1 POLE GKTS. EXCEPT AS NOTED) CONDUIT: 1-1/2' %, w Q U 3 REMARKS Y U PANEL B Y REMARKS SQ. FT. U O U Q LL 50 2 5060 (••) 3/4' 2"8 A/C ol 1 159i50 2 A.H.U. #1 2«6 3/4' 10830 (•+) 2 60 1500 3 4 1500 1500 DISHWASHER 50 2 5060 C•+) 3/4' 208 A/C 2 5 6 A.H.U. n 2P6 3/4' 10830(so) 2 60 3000 � 8 1500 1500 POOL MOTOR 15 1 0 1/2' 12 GENERAL LIGHTING 9 10 GENERAL LIGHTING 12 1/2' f 1 15 15 1 # 1/2' 12 GENERAL LIGHTING Il 12 GENERAL LIGHTING 12 1/2' 8 1 15 20 1 1/2' 12 RECEPTACLE 13 14 RECEPTACLE 12 1/2' 0 1 20 20 1 4 1/2' 12 RECEPTACLE 15 16 RECEPTACLE 12 1/2' • 1 20 20 1 1/2' 12 RECEPTACLE 11 IS RECEPTACLE 12 1/2' 1 20 20 1 & 1/2' 12 G.F.I. BATH REGEPT. 19 20 SMOKE DETECTORS 12 1/2' 5000 1 20 20 1 1500 1/2' 12 JACUZZI 21 22 WATER HEATER 10 1/2' 4000 2 30 23 24 15,11 13-1 2-10 25 26 200 150 400 2-1 28 29 30 31 32 33 34 35 36 3'1 38 39 40 41 42 CONNECTED LOAD:SEE LOAD CALCULATION FEEDER -SEE RISER (A/C RATING 22,000 AMPS) FED FROM:SERVICE NOTE: ALL BEDROOM AND SMOKE DETECTOR CIRCUITS TO BE ARC FAULT PROTECTED (••) AG COMPRESSOR is AIR HANDLER UNIT LOADS ARE NOT CONCURRENT. PANEL A 4 5 CALCULATION& ITEM PANEL A PANEL B SERVICE SQ. FT. 3326 1999 5325 GENERAL LIGHTING 99'18• 5997• 159i50 SMALL APPLIANCES 16500 16500 WASHER 1500 1500 REFRIGERATOR 1500 1500 DISHWASHER 1500 1500 DISPOSAL 1500 1500 DOOR MOTOR 3000 3000 HOOD W/EXHAUST 1500 1500 POOL MOTOR 1500 1500 JACU771 1500 1500 WATER HEATER 4000 4000 SUB -TOTAL V.A. 36918 12997 49975 let. IOKW 10000 10000 10000 REST 40% 10971 1199 15990 AIR HANDLER UNIT 01 10830 10830 AIR HANDLER UNIT 02 10830 10830 RANGE 12000 12000 DRYER 5000 5000 TOTAL VA DEMAND 3i791 32859 64650 AMPS DEMAND (VA./240 V) 15,11 13-1 2-10 BREAKER 200 150 400 CONCRETE FOUNDATION e °� 20• FT. MR* ° :. r• . -... . - BOLTED -TYPE COWECTIONDEVICE OR EXOTHERMIC WELD GROINDNG ELECTRODE CONDUCTOR NONMETALLIC PROTECTIVE SLEEVE ° No.4 AVC. OR LAR53M BARE COPPER CONDUCTOR OR STEEL REINFORCNG 5AR OR n ROD NOT LESS THAN 1/2 NCH a DIAMETER DIRECT CONTACT UTH EARTH ¢ETE-ENCASED ELECTRODE CONSISTING. = ONE OR MORE BARE OR ZINC EINFORCING BARS OF NOT LESS THAN 1/2 ;)F At LEAST 20 FT. OF BARE COPPER LLER THAN No. 4 AND LOCATED WITHIN >M OF A CONCRETE FOUNDATION OR ERECT CONTACT WITH EARTH. ENCASE GfROUND INC ELECTfRODE DTL- 3/4II 11_011 400 AMP METER 221CAICS NEMA 3R ELECT. SERVICE SERVICE 20350 MCMCU 104/0 MCMCU(N) IN -3'0 GOND. PVC A9 I Li lr�u SECOND FLOOR ELECTRICAL PLAN 1/411 3.1/0 THW-CU 1-1/2'0 3#3/0 THW-CU 2'0 0 N N v rn O Q I,���•...,, o _ `� p F R of?j —� CONNECT TO A CONCRETE ENCASED •.•.••••� •.... 4 ELECTRODE BOND TO A 5/8'x10' GND. RODS •,:. �, CA. q,�� •, (SEE DETAIL) ELECT C f SEER ED IAGFRA, N.T.S. ' co Z O co UJ W UQ Zo_ W� 00 — J U L.L w _w Q ^. 0— w Ow Uw 0— mv, 0 }' (]d 00 (D W ~o Z CD r4 SHEET: OF: _f) � M M w 0 J � �O O -j 1a LL QO a c� J � W co 0 Z 0O O U E-2 2