07-420-008SECTION 09330 - QUARRY TILL
11 General' Provide quarry the flooring and base as shown and specified.
A, Standards; Materials and installation shall conform to the following:
1, ANSI A137,1 "Ceramic Tile."
2. TCA "Handbook for Ceramic Tile Installation,"
2.1 Materials.
A. Manufocturers:
1. Quarry Tile: Dal -Tile Corp,, (800) 933=8453, internet ww2.daltile,com.
2. Waterproofing:
a. Setting and Grouting Materials: Mapei Corp, (800) 426-2734, internet
www.mapel.com `
b. Quarry Tile Base Memebrone; Laticrete (800) 243-4788 x 219, internet
www,loticrete,com
B. Quarry Tile: Dol -Tile 6" x 6" x 1/211 quarry the with 5" cove base and appropriate trim, Price
Group 11 # OQ40, Red Blaze color,
1, Rest Rooms: Provide smooth finish quarry tile.
2, Entre Kitchen Area: Provide abrasive non -slip finish quarry tile.
C. Waterproofing for elevated floor slabs: Mapei Planicrete W, heavy-duty trowelable two
component waterproof membrane and adhesive.
D. Setting Adhesive: Mapei Ultra/Flex 1 polymer modified one-step mortar conforming to ANSI
A118.4.
E. Grout: Mapei Ultra/Calor, rapid curing, efflorescence free, color consistent grout conforming
to ANSi A118.6; #09 Grey Color.
F. Quarry Tile Base Membrane: Laticrete 9235 waterproof membrane conforming to ANSI
A118.10-1999.
3.1 Installation
A. Preparation: Clean substrate surfaces, scheduled to receive quarry tile, thoroughly and
remove all coatings that may impair bond.
1. Center the fields bath directions in each floor area. Adjust layout to minimize file
cutting. Avoid file less than one-half size. Locate cuts to be least conspicuous.
2. Maintain units uniformly "in plane." Provide straight, uniform joint widths and grout
lines.
B. Elevated Floor Slabs; Install waterproofing membrane at elevated floor slab surfaces
scheduled to receive quarry the floor finish. Install membrane materials in accordance with
manufacturer's installation instructions to produce a waterproof membrane of uniform
minimum 30 mil thickness bonded securely to substrate.
1. Extend waterproofing up vertical wall surfaces minimum 10" high,
2, Extend membrane down into floor drain flanges to assure continuous waterproofing at
drainage points.
C. Wet Areas; Install waterproofing membrane at oil quarry the wall base. Install membrane
materials in accordance with manufacturer's installation instructions to produce a waterproof
membrane of uniform Minimum 30 mil thickness bonded securely to substrate.
1, Extend Laticrete 9235 .waterproofing up all vertical wall surfaces receiving quarry the
base minimum 10" high. Extend Laticrete 9235 waterproofing membrane 10" minimum
horizontally from all vertical wall surfaces receiving quarry tile base.
D. Installation: Install, grout and clean ceramic the in accordance with referenced TCA
installation details and ANSI standard specifications for setting methods scheduled,
1, Floors: Latex -Portland cement mortar on concrete; TCA detail F113 and ANSI A148,5,
grout ANSI A108.10, Wet cure grout.
2. Base: Latex-portland cement mortar on cement board.
SECTION 09510 - ACOUSTICAL CEILING SYSTEMS
1.1 General Provide acoustical ceiling systems as shown and specified,
A. Standards; Materials and installation shall conform to the following:
1. CISCA "Acoustical Ceilings - Use and Practice."
2,1 Materials:
A. Manufacturer: USG Interiors, Inc., (840) 950-3839, internet www.usg.com
B. Ceiling Panels; USG "Sheetrock Lay -1n ClimoPlus Na. 3270" ceiling panels with white, stipple
texture, vinyl facing, 24" x 48" x 1/2".
C. Suspension System: Comply with ASTM 0635. Provide direct -hung systems adequate to support
light fixtures, ceiling diffusers and other normal accessories, Maximum deflection 1/360 of the
span. Intermediate duty structural class,
1. Exposed "Tee" grid system: USG "Dann DX System" non -fire rated with 15/16" exposed
face, cold -rolled galvanized steel with aluminum face cap, white paint finish on exposed
surfaces. Provide hemmed edge aluminum wall angles, 15/16" exposed leg, white point
finish matching exposed grid.
3.1 Installation
A. Install acoustical ceiling materials and suspension systems in strict accordance with
manufacturer's recommendations, complying with governing regulations and industry standards
applicable to the work.
B. Suspension system installation shall comply with ASTM 0636 requirements and be laser leveled,
maximum deflection of 1/360 of span and maximum surface leveling tolerance 1/8" in 12'-0".
1, Secure wire hangers by looping and wire -tying either directly to building structure or
hangers that are secure and appropriate for substrate,
C. Provide edge trim molding at perimeter of acoustical ceiling installation and intermediate vertical
surfaces. Use maximum lengths. Miter trim corners to Provide tight, accurate joints. Connect
moldings securely to substrate surfaces,
D, Install acoustical lay=in panels level, in uniform plane, with joints snug and square and panels
free from damage or sailing. Fit border units neatly against abutting surfaces. Scribe and cut
panels to fit accurately at borders and penetrations.
SECTION 09640 - WOOD FLOORING
11 General: Provide wood flooring as shown and specified,
A. Standards: Materials and installation shall Conform to the fallowing;
1. NGFMA "Hardwood Flooring Installation Manual."
2. NGFMA "Hardwood Flooring Finishing/Refinishing Manual."
B. Delivery, Storage and Handling; Place wood flooring materials in rooms or spaces to receive-
flooring
eceiveflooring a minimum of 48 hours before the start of installation, Open packages of sealed
flooring to permit natural adjustment of moisture content. Maintain temperature range of 601
F to 702 F before, during and after installation of flooring,
2.1 Materials:
A. Woad flooring: 3/4" x 21/4" kiln -dried, #2 Select Red Oak hardwood strip flooring, plain sawn,
tongue and groove edges.
1. Standard random lengths complying with NGFMA grading rules.
B. Fasteners: Screw type flooring nails, fully barbed flooring brads or machine driven fasteners as
recommended by the flooring manufacturer.
C, Underloyment: APA -CC -EXT plywood underlayment, minimum 3/4" thick,
11 Installation:
A. Preparation; Before_ installing flooring, clean and inspect substrate surfaces.
1. Clear away debris, scrape up cementitious depositsA, remove sealers, dust, dirt, ail, grease
and other substances detrimental to proper performance of woad flooring.
2. Perform band and moisture tests on concrete slabs to determine that concrete surfaces
are sufficiently cured and are ready to receive flooring.
a. When moisture is present, install a single layer of polyethylene vapor barrier over
concrete, all edges lapped 4". All joints sealed with tape.
3, Install single layer of plywood underlayment. Space joints 1/4" on all sides.
4. Vacuum underlayment surface clean immediately before flooring installation.
B. Install wood strip flooring in accordance with NGFMA standards, instructions and
recommendations for the applications indicated.
1. Blind nail wood strip flooring into plywood underlayment. Space fasteners at 8" intervals,
with minimum two fasteners per strip. Countersink all nail heads.
2 Provide expansion space at all wall lines.
C, Sanding: Allow installed wood strip flooring to acclimate to building conditions before sanding.
1. Machine sand in accordance with manufacturer's recommendations. Clean with power.
vacuum. Verify that entire surface of floor is level and smooth without ridges or cups.
D, Finish; Finish installed woad flooring with two coats of clear urethane floor finish. Provide-
surface
rovidesurface preparation, finish materials and application conforming to Section 09900 =Paints and
Coatings requirements.
SECTION 09810 - ACOUSTICAL WALL TREATMENT
1,1 General Provide acoustical wall panels as shown and specified,
2.1 Materials;
A. Manufacturer: Tectum Inc. (888) 977=9691, internet: www.tectum.com
B. Wall Panels: Standard Tectum Acoustical Wall Panels, natural finish cement wood fiber wall
panels, composed of aspen wood fibers and an inorganic cement binder, formed in a continuous
process under heat and pressure, 1" thick panels by size indicated,
C. Accessories: Provide all mounting fasteners and accessories to complete the installation,
3.1 Installation
A. Install acoustical wall treatment panels in strict accordance with manufacturer's
recommendations and drawing details.
SECTION 09900 - PAINTS AND COATINGS
1.1 General: Provide points and coatings as shown and specified.
A, Provide surface preparation, prime, intermediate and finish coatings for interior and exterior new
and existing scheduled surfaces and items.
B. Provide Tenant -selected finishes and colors for all exposed surfaces, unless otherwise indicated,
C. Quality Assurance:
1. Application; Performed only by skilled, experienced painters.
2. Provide lead free prime and finish coatings, All tap coatings shall be mold and mildew
resistant,
D. Maintenance: Furnish extra paint materials from the some production run as the materials
applied in the quantities described below. Package paint materials in unopened, factory -sealed
containers for storage and identify with labels describing contents. Deliver extra Materials to
the Tenant.
1. Provide one gallon of paint and woad stain of each type and calor required for
maintenance purposes. Provide original, unopened, labeled containers with calor samples
and a list of project use.
SECTION 09900 - PAINTS AND COATINGS
1,1 General Provide points and coatings as shown and specified.
A. Provide surface preparation, prime, intermediate and finish coatings for interior and exterior
new and existing scheduled surfaces and items,
B, Provide Tenant- selected finishes and calors for all, exposed surfaces, unless otherwise
indicated.
C, Quality Assurance:
1, Application; Performed only by skilled, experienced painters.
2. Provide lead free prime and finish coatings. All top coatings shall be mold and
mildew resistant.
D. Maintenance: Furnish extra paint materials from the some production run as the materials
applied in the quantities described below. Package paint materials in unopened,
factory -sealed containersfor storage and identify with labels describing contents. Deliver
extra materials to the Tenant.
1, Provide one gallon of paint and wood stain of each type and color required for
maintenance purposes. Provide original, unopened, labeled containers with color
samples and a list of project use,
21 Materials;
A, Manufacturers;
1, Paint: Sherwin-Williams Co. (S -W), (800) 797-8010 for Customer Service, (800)
474-3746 for nearest S -W dealer, internet www,sherwin-williams.comm
2, Woad Clear Finish: Sikkens, (866) 745-5367, internet www.nam.sikkens.com
B. Materials: No substitutions allowed. Paint products are custom colors for Tenant and .
scheduled products must be factory- batWhed. I - at, tary-botched products are available in
5 -gallon containers only. Allow 7-10 Working Days to receive factory -botched products.
C, Exterior Coatings:
Exterior Metals:
Preparation; Remove all rust, grease, ail and foreign material. Uniformly roughen
surface with 150 -grit paper Remove loose dust.
Prime: (1) coat S -W, PraCryl Universal Water Based Primer (866-314 Series)
Finish: (2) coots S -W, SherCryl HPA High Performance Acrylic (866-300 Series)
"Chipotle Red" B66RW31 (Factory -batched)
Application; Conventional or HVLP (high volume low pressure)
Existing Stucco/EIFS Surfaces:
Preparation; Wash to remove all rust, grease, dust, dirt, loose and other
foreign material. Allow to dry thoroughly.
Prime: (1) coat S -W, Loxon Conditioner (A24-100 series)
Finish:. (2) coats S -W, Duration Exterior Flat (K32 Series)
Formula; "Chipotle Gray'
Application: Airless spray with back roll using Y4" nap roller
Exterior Wood Doors - Clear finish:
(Door and Window finishes shall be shop applied in a controlled environment)
Preparation; Remove mill glaze (planers crush) on new woad with 80-120 grit
A. Interior Coatings:
Interior Metals: (Metal deck, doors, door frames, rails and railing frames)
Preparation: Clean thoroughly and remove all rust, grease, oil and foreign Material.
Prime: (1) coat S -W, PraCryl Universal Water Based Primer (866-310 Series)
Finish: (2). coats S -W, SherCryl HPA High Performance Acrylic (B(56�300 Series)
"Chipotle Red" B66RW31 (Factory -batched)
Application: Conventional spray, HVLP or Airless spray
Touch=ups shall be done with conventional spray or airless equipment or
brush or roller,
Drywall_
Preparation: Remove dust, dirt, loose and other foreign material. Fill hairline cracks,
hales and other defects with filler compatible with finish treatment. Sand
smooth.
Application; Brush and 1/2" nap roller
Prime: 1 coat S -W, COLOR PRIME, Interior Latex Primer (B28W110)
Finish: (1) coats S=W, Duration Home Interior Latex Satin (A97W151F)
Formula: S -W #1053 "Light Moves"
OR
sandpaper. Sand in direction of the grain. Remove dust
from the surface
(2) coats S -W, SherCryl HPA High Performance Acrylic (866-300 Series)
and wipe down with tack cloth or damp cloth,
"Chipotle Red" B66RW31 (Factory -botched)
1st coat
SIKKENS Cental 1 - 478 Natural
(Wood Trim and
Application:
Apply liberally with longhair natural bristle brush to all 6
surfaces of doors
U
and windows. Wait 24 hours before next coat,
2nd coat
SIKKENS Centel Door & Window Satin
SIKKENS Cental BL Interior Clear - Low Lustre
Application;
Apply liberally with longhair natural bristle brush to oil 6
surfaces of doors
surfaces. Wait minimum of 4 hours before next coat.
and windows. Wait 24 hours before next coat.
SIKKENS Cental BL Interior Clear - Satin
3rd coat
SIKKENS Centel Door & Window Satin
0
Application;
Apply liberally with longhair natural bristle brush to all 6
surfaces of doors
Application:
and windows,
A. Interior Coatings:
Interior Metals: (Metal deck, doors, door frames, rails and railing frames)
Preparation: Clean thoroughly and remove all rust, grease, oil and foreign Material.
Prime: (1) coat S -W, PraCryl Universal Water Based Primer (866-310 Series)
Finish: (2). coats S -W, SherCryl HPA High Performance Acrylic (B(56�300 Series)
"Chipotle Red" B66RW31 (Factory -batched)
Application: Conventional spray, HVLP or Airless spray
Touch=ups shall be done with conventional spray or airless equipment or
brush or roller,
Drywall_
Preparation: Remove dust, dirt, loose and other foreign material. Fill hairline cracks,
hales and other defects with filler compatible with finish treatment. Sand
smooth.
Application; Brush and 1/2" nap roller
Prime: 1 coat S -W, COLOR PRIME, Interior Latex Primer (B28W110)
Finish: (1) coats S=W, Duration Home Interior Latex Satin (A97W151F)
Formula: S -W #1053 "Light Moves"
OR
Finish:
(2) coats S -W, SherCryl HPA High Performance Acrylic (866-300 Series)
"Chipotle Red" B66RW31 (Factory -botched)
Interior Woad Trim
and Plywood - Clear Urethane Finish:
(Wood Trim and
Plywood finishes shall be shop applied in a controlled environment)
Preparation;
Sand wood trim and plywood with 80=120 grit sandpaper. Sold in direction
U
of the groin. Remove dust from the surface and wipe down with tack
cloth or damp cloth.
1st coat
SIKKENS Cental BL Interior Clear - Low Lustre
Application:
Apply liberally with longhair nylon polyester brush or spray to all exposed
surfaces. Wait minimum of 4 hours before next coat.
2nd coat
SIKKENS Cental BL Interior Clear - Satin
Application:
Apply liberally with longhair nylon polyester brush or spray to all exposed
0
surfaces. Wait minimum of 4 hours,
3rd coat
SIKKENS Centel BL Interior Clear = Satin
Application:
Apply liberally with longhair nylon polyester brush or spray to all exposed
surfaces,
Interior Wood Flooring - Clear Urethane Finish_
Preparation;
Machine sand installed wood flooring with 100-120 grit sandpaper. Sand in
direction of the grain, Remove dust from the surface with vacuum and
wipe down with tack cloth.
Finish:
(2) coots S -W, Wood Classics Waterborne Polyurethane Varnish
(A68 Series), First coat gloss finish, second coat satin finish.
Application:
Synthetic bristle brush or 1/4" nap synthetic roller. Avoid over -brushing or
rapid rolling.
E, Calor Guide:
Where What Color Sheen
Exterior ferrous metals SherCryl HPA "Chipotle Red" Semi
Glass
Exterior ferrous metals, Duration Exterior Satin S -W #4028 "Silver" Satin
where indicated
Existing stucco and EIFS Duration Exterior Flat "Chipotle Gray" Flat
Exterior gypsum- board, Duration Exterior Satin S -W #4028 "Silver"
Satin
where incicated
Interior metal deck, doors, SherCryl HPA "Chipotle Red" Semi
door frames, rails, Glass
and rail frames
Interior ferrous metals, Duration Exterior Satin S -W #4028 "Silver" Satin
where indicated
Dining roam and Duration Home S -W #1453 Satin
hallway Drywall "Light Moves"
Dining room and SherCryl HPA "Chipotle Red" Segni
hallway Drywall Glass
Restroom and serving_ Duration Horne S -W #1053 Satin
3.1 Installation: area soffit drywall "Light Moves"
A, Preparation:
1. Provide necessary staging, ladders, shields, protective coverings and drop cloths.
Protect floors, walls and adjacent work and materials. Remove and properly replace
temporary protection and coverings removed from any port of the work or finish.
Repair domage at Contractor's expense,
2, Clean and prepare substrate surfaces in accordance with manufacturer's instructions
for each particular substrate condition. Clean and correct defects and deficiencies in
substrate surfaces to be pointed before applying paint or finish treatments,
B. Application:
1. Mix, prepare and apply point and finish treatment materials in accordance with
manufacturer's directions.
2. Apply point and finish treatment materials with brush or roller. Spray application of
materials permitted only when specifically indicated.
a. Apply materials at not less .than the manufacturer's recommended spreading
rate, to provide a total dry film thickness as recommended by point material
manufacturer. Apply each coat of proper consistency,
b. Keep brushes and rollers clean, free from contamination and suitable for the
finish required.
C, Unless otherwise indicated, allow exterior points .to dry for 48 hours and interior
paints to dry for 24 hours between coats.
d, Sand lightly and remove dust between coats to achieve required finish.
e. Finished surfaces shall be uniform in finish and color and free of brush marks,
sagging,' holidays, corduroy and other imperfections. Coverage and hide shall be
complete.
f, Edges of point or finish adjoining, other materials or colors shall be sharp and
clean without overlapping. Cut paint in neatly around glass or other edges.
g. Paints and coatings work is subject to acceptance by the Tenant. Correct
unsatisfactory work not complying with these specifications as directed by the
Tenant.
t5 u U S4 1 U U
DIVISION 10 - SPECIALTIES
SECTION 10522 - PORTABLE PIPE EXTINGUISHES u ° u
- Q C,_
1,1 General Provide portable fire extinguishers as shown and specified.
ff �ti4 u i1G stG
A. Standards: Materials and installation shall conform to the following: uQQ _
1. NFPA 10 "Standard for Portable Fire Extinguishers. �Qu u Quuo. _
2,1 Materials;
A, Provide minimum 10 Ib, capacity fire extinguishers in quantity and type complying with local
code and fire regulations requirements.
1. Provide new fire extinguishers fully loaded, tested, UL and FM labeled and listed and
ready for use.
2, Provide manufacturer's recommended mounting brackets and hardware,
3.1 Installation:
B. A. Install fire extinguishers in accordance with manufacturer's installation instructions, at
heights and locations acceptable to the local fire regulations enforcement authority
DIVISION 11- NOT APPLICABLE
DIVISION 12- FURNISHINGS
SECTION 12495 - WINDOW SHADES
1,1 General: Provide window shades as shown and specified.
A. Standards: Shade fabric material shall meet the requirements of the following:
1. NFPA 701 Flame Test and California US Title 19 for flame retardant materials,
B, Field measure window openings and verify installation conditions prior to window shade
fabrication
C. Warranty;
1, 5 years against defects in materials and workmanship.
2, 1 year for service call repairs and adjustments,
2,1 Materials:
A, Manufacturer; Insolroll. Window Shading Systems, Inc. (800) 447-5534, internet
www.insolroll.coM
B. Window Shades: Insolroll 2000 Solar Screen Shades, manual operation,
- 1. Solar Screen Shade Fabric: Insolroll woven_,; fiberglass yarn, 5% openness,
Charcoal/Bronze color,
2. Provide manufacturer's recommended mounting brackets and hardware.
C. Fabrication: Unless otherwise indicated, fabricate window shade units to completely fill
existing window openings from head to sill and jamb to jamb. -
1, Adjustment system controlled by plastic bead chain on polyester card. Multi -banded
steel spring clutches keep shade in desired position.
2. Roller tube 2" extruded aluminum, sized to minimize deflection,
3. Fabric attached to roller tube using. two-sided adhesive tape.
4. Fabric bottom hem RF heat sealed pocket with enclosed hem bar.
3.1 Installation;
A. Install window shades level and plumb in accordance with manufacturer's installation
instructions and drawing details. Provide units securely anchored in place with recommended
hardware and accessories to provide smooth operation without binding.
DIVISIONS 13 = 14 - NOT APPLICABLE
_ _INtitI LTAk1T:
GLAVAN EEHtR ARCHITECTS INC.
2 M I;RAN0VA PLACE
Q
'CO UM6US, OHIO 45215
T E L 6 1 4 2 2 8 8 4 0 0
FAX ,61 4,228.8837
W W W, G L A V A N. C O M
=
AV
a�V
I
00 1
b
U
-
! LL__--�-�
GOPYRIGHT Zi307
THIS DRAWING IS AN INSTRUMENT OF
SERVICE, FANO AS SUCH, REMAINS THE
PROF -ERT, OF GHIPOTLE MEXICAN FRILL
INC.. PERMISSION FOR USE OF THIS
DOCUMENT IS LIMITED AND CAN BE
EXTENDEC ONLY BY WRITTEN AUREEMENT
WITH GHIPOTLE MEXICAN BRILL INC..
i
154JIWAZEE STREET
DENVER, E1-31-01RADO E30202
PHONE: (303) 595-4000
FAX: (303) 595-4014
INTERNET-. WWW,OHIPOTL€.COM
contents:
peri f icetien
i
13
i -
Date of Y %st Print:
i
.2007i
I
00 1
b
U
-
! LL__--�-�
rL
W
0
cr i�
W
0 ;W
-
-
(j} i>
-
M
I
!
Issue Record:
03.05.2067
FIRE -UERM SUBMITTAL
Revision -s:
A03.06.2007
€RPB
COMMENT -
I
Drown:
A€,J,JD
I
Checked;
CO
Project No,
CMC30i
contents:
peri f icetien
i
13
i -
Date of Y %st Print:
i