06-633-016••s• •o s s a•.- boil, • • ! s r y • s s s • y y I- FLOOR AREAS HAVE A 4' CONC. SLAB ON WELL COMPACTED FILL OVER A POLYETHYLENE VAPOR BARRIER AND REINF. W/ 6x 6-6/6 WWF. (U.ON.) LAPPED 6' MIN. (WWF SHOULD BE PLACED 2' BELOW THE TOP OF THE SLAB IN ORDER TO BE EFFECTIVE). 2- PROVIDE DIAMOND SHAPED ISOLATION JOINTS AT ALL COLUMNS ((o' CLEAR OF COLUMN AT CL05E5T POINT) AND SAW CUT JOINTS AT ALL COLUMN CENTER LINES AND A$ INDICATED ON PLAN. (NO BAY LARGER THAN 25' X 25') COORDINATE WITH ARCHITECTURAL DRAWINGS FOR ANY SPECIAL JOINT PATTERN THAT MAY NEED TO BE FOLLOWED. 3- COORDINATE ALL FLOOR SLOPES AND ELEVATION WITH ARCHITECTURAL DRAWINGS. COORDINATE ALL DIMENSIONS WITH ARCHITECTURAL DRAWINGS. 4- CENTERLINE OF COLUMN OR WALL IS CENTER LINE OF FOOTING 5- TOP OF FOOTING ELEVATION: ALL FOOTING5: EL. - 1-4'(U.ON,). 6- FOR GENERAL NOTES AND SCHEDULES SEE DWG, 5-5 MA80NRY NOTE&: (TYPICAL FOR ALL LEVELS) I- PROVIDE M 9 ga. LADDER TYPE HORIZONTAL MASONRY REINIF, 6 16' O/C IN ALL MASONRY WALLS (U.ON.). 2- SPLICE VERTICAL MASONRY WALL REINFORCEMENT 48 BAR DIAMETERS AS FOLLOWS: FOR* 5 BARS: 30' FOR M 6 BARS: 36' FOR # 1 BARS: 42' 3- AT EITHER SIDE OF OPENINGS BETWEEN 3'-0' AND 4'-0' INCLUSIVE PROVIDE 2 N 5 VERT. IN GROUTED CELL (U.ON) FOR OPENINGS FROM 4'-0' TO (o'-6' PROVIDE 2 0(o VERT. IN GROUTED CELL (U.ON) FOR OPENINGS FROM 6'-(O' TO 8'-0' PROVIDE 2 01 IN GROUTED CELL. (U.ON) IN OPENINGS WIDER THAN 8'-0' PROVIDE AN 8x 16 CONC. TIE COL. W/ 4 0(o VERT. 4 03 TIES ,0 8' 0/C (U.ON) 4- ALL MASONRY IN THIS PROJECT HAS BEEN DESIGNED IN ACCORDANCE W/ ACI 530-99/ASCE 5-99 AND THE FLORIDA BUILDING CODE. ALL MASONRY IN THIS PROJECT IS TO BE CONSTRUCTED IN ACCORDANCE WITH ACI 530-99. 5- MASONRY UNITS TO COMPLY WITH ASTM C-90 AND HAVE A MIN F'M AND A NET AREA COMPRESSIVE STRENGHT (N.A.C.5.) AS FOLLOW: FOUNDATION TO ROOF FLOOR: F'M = 2000 PSI AND N.A.C.S. -- 2800 PSI. CONTRACTOR MUST PROVIDE WRITTEN CONFIRMATION FROM THE MASONRY MANUF. OF THE ABOVE REQUIREMENTS. 6- GROUT TO HAVE A MIN. F'c=3000 PSI AT 28 DAYS WITH A SLUMP OF 8' ,/- 1' AND TO BE POURED IN 4'-0' LIFTS. 7- USE BAR SPACERS POSITIONERS TO MANTAIN MASONRY REINF. IN PROPER LOCATION AND VERTICAL ALIGNMENT. rAA mo—mm—sm 1/411 = V-011 FOOTING REINF. NOTE: PROVIDE 36' x 36' CORNER BARS AT ALL CORNERS AND FOOTING CHANGES IN DIRECTION. SPLICE REINF. 36 BAR DIAMETERS (MIN.) CONCRETE 3TAIR5 5' CONC. SLAB ON GRADE W/ 0 3 1112- EA. WAY 4 1 0 3 EA. NOSING r C THESE PLANS ARE FOR RUILpINCs pEPARTMENT RE 1EW. . THEY ARE NOT TO DE CONSTRUED AS FINAI,,CON5TRUGTION - POCUMENT5 UNTIL ALL BUILDING DEPARTMENT, AM.PO IAL 0 ARE OBTAINED AND COMMENTS INCORPORATED INTO THESE DU6 G 0 0 Z w U Lu ❑ 0 w U z w _® VJ mo�w// LL. Q U O O u- L�.L/r C I.J.. Q M� LJ.J UW 00 d� ® v� �! o SHEET OF: M M � M > J IY O-1 m L - Ow �> dU J � W D (DO Z C O U Lo mt O O O 1 CK 1 U w AN S-1 7