06-633-013ELECTRICAL 5�1„I CL LIST:
3 W. GROUNDED DUPLEX RECEPTACLE 20 A. 120 V. M.N.+12' AFF.
3 W. GROUNDED SINGLE RECEPTACLE 30 A. 240 V. M.N.+12' AFF.
3 W. GROUNDED SINGLE RECEPTACLE 60 A. 240 V. M.H.+12' AFF.
KD PUSH BOTTON
JO JUNCTION BOX GIELING OR FLOOR MOUNTED
19 JUNCTION BOX WALL MOUNTED M.H. AS DIRECTED
® VOICE DATA OUTLET M.H. + 12' AFF. OR AS INDICATED
[NQi TELEVISION OUTLET M.H.+12' AFF.
ifl [I] INTERCOM
Q THERMOSTAT M.H. +50' AFF. (REFER t0 A/C DWCx5. FOR LOCATION)
4 MOTOR OUTLET
® ELECTRICAL PANEL
® SWITCH BOARD
13 FUSED D15CONNECTED SWITCH W/ DUAL ELEMENT FU81=5
F65il CIRCUIT BREAKER (HAGR TYPE IF FOR A/C UNIT)
_1*1- INCANDESCENT FIXTURE OUTLET GIELING MOUNTED
F0 INCANDESCENT FIXTURE OUTLET WALL MOUNTED
O RECESSED HI -HAT LIGHT CEILING MOUNTED
CEILING FLUORESCENT STRIP
FLOODLIGHT
SINGLE POLE TOGGLE SWITCH M.H. 50' AFF
$3
3 THREE WAY SWITCH M.H. 50' AFF
SINGLE POLE SWITCH W/ DIMMER M.H. 50' AFF
sp ELECTRICAL SMOKE DETECTOR DEVICE
EXHAUST FAN
CEILING FAN
1 GROUND FAULT INTERRUPTER
Wp• WATER PROOF.
Vf'• VAPOR PROOF.
® 240 V. OUTLET
❑O METER
400 AMP METER
221GAIG5
NEMA 3R
ELECT. METER
1-1/2'6
3.3/0 TWW-CU 2'0 3.3 THW-CU 1-1/41♦
SIw1;lvICE
2*350 MGi',GU
1+'4/0 MCMCUIN) SIZE GUTTER 70 N.E.C. PANEL 'A" PANEL 'B'
IN -3"0 GOND. PVC 313-9,Wb)
-° ------~
"2 IN 1' CUND, 12x8xL 100 A 200 A
ELECT. SERVICE
C.!�.P.
SERVICE CONNECT t0 A CONCRETE ENCASED
2"350 MCMCU I ELECTRODE BOND TO A 5/8'x10' GND. RODS
1'4/0 MCMCU(N) (SEE DETAIL)
IN -3'0 COND. PVC 6 �
GENERAL ELEGTRfGAL NOTES:
1.0 - GENERAL
1.1 - WORK INCLUDED UNDER THIS DIVISION CONSIST OF PROVIDING LABOR MATERIALS,
APPLIANCES, EQUIPMENT, TOOLS, TRANSPORTATION, SUPERINTENDENCE AND SERVICES REQUIRED
TO CONSTRUCT AND INSTALL COMPLETE AND PROPER OPERATING ELECTRICAL SYSTEMS
AS SPECIFIED, INDICATED AND ELSEWHERE REQUIRED
2.0 - EXAMINATION OF SITE
2-1 - BIDDER 15 ADVICED TO VISIT THE SITE AND ACQUAINT HIMSELF WITH WORKING CONDITIONS.
CONTRACTOR SHALL ACCEPT CONDITIONS AS THEY EXIST ON BID DATE.
3.0 - MATERIALS
3.1 - MATERIALS, EQUIPMENT AND APPLIANCES SHALL BE NEW AND OF BEST QUALITY
UNLESS OTHERWISE INDICATED.
32 - DETERMINE THAT PROPOSED EQUIPMENT CAN BE INSTALLED IN SPACE AVAILABLE. INSTALL
EQUIPMENT SO PARTS ARE READILY ACCESSIBLE FOR INSPECTION AND MAINTENANCE EXTRA
COMPENSATION WILL NOT BE ALLOWED FOR DISMANTLING EQUIPMENT TO OBTAIN ENTRANCE INTO BLDG.
33 -MATERIALS SHALL BEAR UNDERWRITER'S LABEL WHERE SUCH STANDARDS HAVE BEEN TA LIS HED
AND LISTED BY UNDERWRITER'S LABORATORIES INC.
3.4 - MATERIALS, EQUIPMENT AND APPLIANCES SHALL CONFORM TO LATEST STANDARDS OF ;
AMCA, $MAGNA, ANSI, A$HRAE, ASME, ASTM, NEMA, ARI AND NFPA.
3.5 - USE EXTREME CARE IN SELECTION AND INSTALATION OF EQUIPMENT TO INSURE THAT NOISE AND
VIBRATION ARE HELD TO ABSOLUTE MINIMUM. CORRECT OBJECTIONABLE NOISE
AND VIBRATION. PROVIDE ELIMINATORS REQUIRED FOR PROPER RESULTS.
4.0 - PERMITS, FEES AND CODES
4.1 - COST FOR FEES, PERMITS, TESTS NAD INSPECTIONS SHALL BE PAID FOR BY THE CONTRACTOR
4.2 - INSTALLATION SHALL BE IN ACCORDANCE WITH APPLICABLE CODES AND REGULATIONS INCLUDING:
F.S.C., N.E.C., NF.P.A., 0.5.HA. AND STATE, COUNTY AND CITY DEPARTMENTS OF HEALTH.
5-0 - COOPERATE WITH OTHER TRADES
5.1 - MAKE KNOWN ARRANGEMENT OF WORK AND CHECK ARRANGEMENT AND LOCATION OF OTHER TRADES
TO AVOID CONFLICTS. EXAMINE DRAWINGS OF OTHER TRADES TO DETERMINE EXACT EQUIPMENT LOCATION.
6.0 - OPERATING INSTRUCTIONS
6-1 - CONTRACTOR SHALL PROVIDE TO OWNER OPERATION AND MAINTENANCE MANUALS.
REPRESENTATIVE IN OPERATION OF ALL EQUI
WNER'S P
CONTRACTOR SHALL INSTRUCT OWNER OR OMENT.
TYPE WRITTEN LABEL5 SHALL BE PLACED IN PANEL BOXES DESIGNATING CIRCUITS LAYOUTS
1.0 - INSPECTION .
1.1 - NOTIFY OWNER TWENTY-FOUR HOURS IN ADVANCE WHEN PIPING OR EQUIPMENT IS t0 BE TASTED,
BEFORE PIPING IS INSULATED OR CONGEALED, AND BEFORE TRENCHES ARE BACKFILLED.
1.2 - FAILING TO COMPLY WITH THE ABOVE, CONTRACTOR $HALL UNCOVER AND RETEST LINES,
REPAIRIG DAMAGE TO OTHER CONTRACTOR'S WORK, AS WELL AS HIS OWN.
1.3 -BEFORE REQUESTING FINAL PAYMENT, INSPECT INSTALLATION TO ASSURE THAT WORK 18 COMPLETE
AND REQUIREMENTS OF CONTRACT HAVE BEEN FULFILLED.
8.0 - CUTTING AND PATCHING
8.1 - UNLESS OTHERWISE INDICATED, DO NO MORE CUTTING AND PATCHING THAN REQUIRED
FOR INSTALLATION OF WORK
82 - CUTTING OF STRUCTURAL MEMBERS OR EXPOSED SUI;;;�FACE OF CONCRETE BLOCK WILL NOT BE PERMITED.
9.0 - MATERIALS AND EQUIPMENT
9.1 - CONDUCTORS SHALL BE THWN COPPER AS NOTED ON DRAWINGS.
92 - RECEPTACLES, SWITCHES AND TELEPHONE OUTLETS SHALL BE AS MANUFACTURED BY LEVITON,
HUBBEL OR APPROVED EQUAL. COLOR AND STYLE AS SPECIFIED BY ARCHITECT AND/OR OWNER
9.3 - COMPUTER OUTLETS: (IF APPLICABLE) SHALL BE AS SPECIFIED BY OWNER
9.4 - PANELBOARDS:
A. GENERAL: INTERRUPTING CAPACITY RATINGS SHALL BE VERIFIED AND BASED ON THE AVAILABLE
SYMMETRICAL FAULT CURRENT GIVEN BY THE POWER COMPANY UPON LOCATION AND
INSTALLATfON OF TRANSFORMER
B- DIRECTORY: COMPLETE AT END OF JOB, TYPEWRITTEN.
C- FINISH: ANSI %I ENAMEL OVER A RUST INHIBITING TREATMENT AFTER FABRICATION AND BEFORE
ASSEMBLY. AFTER INSTALLATION, AND BEFORE ACCEPTANCE BY OWNER, ASSEMBLY SHALL BE PAINTED
WITH A RUST INHIBITING PAINT ( COLOR SELECTED BY ARCHITECT )
D- NAMEPLATES: PROVIDE A LAMACOID NAMEPLATE WITH 5/16' LETTERS ENGRAVED ON FRONT FACE
SHOWING PANEL NAME, VOLTAGE AND PANEL RATING. COORDINATE TO GIVE SAME NAME AS SHOWN
ON PANELBOARD SCHEDULE.
9S - FIXTURES:
A. THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL LIGHTING FIXTURES AS SPECIFIED ON
DRAWING WITH OWNER AND /OR ARCHITECT APPROVAL. VERIFY BEFORE PURCHASE AND INSTALLATION.
9.6- LAMPS: ALL LAMPS USED ON THIS PROJECT SHALL BE NEW, DELIVERED TO THE JOB SITE IN THE ORIGINAL
PACKING CASES AND SLEEVES AND SHALL BE OF THE SAME MANUFACTURER UNLESS OTHERWISE SPECIFIED.
9.1 - BALLAST: ALL. BALLAST SHALL BE RATED TO OPERATE AT THE SERVICE VOLTAGE AS SHOWN AND AS
SPECIFIED, PLUS OR MINUS THE DEVIATIONS WITH THE ELECTRIC SERVICE COMPANY
IS ALLOWED BY FRANCHISE.
10.0 - FUSES
A - SUPPLY AND INSTALL ALL FUSES IN EACH FUSED DEVICE.
B - ALL AIR CONDITIONING AND KITCHEN EQUIPMENT SHALL BE FUSED AS PER MANUFACTURER'S
RECOMENDATION5 AND SPECIFICATIONS.
G - INSTALL LABELS IN ALL FUSED DEVIGES INDICATING PROPER SIZE FUSE t0 USE.
11.0 - MISCELLANEOUS
11.1 - ALL EMPTY CONDUIT t0 BE SUPPLIED WITH NYLON PULL WIRE.
11.2 - ALL FLEX CONDUIT SHALL HAVE 'TITE-BITE' CONNECTORS.
113 - ELECTRICAL CONTRACTOR t0 INSTALL AND WIRE OUTLETS IN FIXTURES WHERE SHOWN ON DRAWINGS
-OUTLETS TO BE INSTALLED IN FIXTURES AFTER FIXTURES INSTALLATION.
11.4 - ALL DEDICATED CIRCUITS SHALL BE LABELED AS SUCH AT OUTLET.
11.5 - THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING AND VERIFYING THE TELEPHONE
COMPANY REQUIREMENTS FOR INSTALLATION OF SERVICE AND ADVISE THE OWNER AND/OR
THE ENGINEER OF ANY ADDITIONAL REQUIREMENTS THAT MAY BE NECESSARY.
Ilb - THE CONTRACTOR $HALL BE RESPONSIBLE FOR COORDINATING AND VERIFYING THE ELECTRICAL
COMPANY'S REQUIREMENTS AND SERVICE ENTRANCE FOR THE BUILDING TO MAIN ELECTRICAL ROOM.
ALL OUTLETS PLATE$ SWITCHES ETC. TO BE WHITE.
h
.ELECTFRIG RISER DlAG;fR/4rj_
N.T.S.
CONGSRI�tE PaJINDATION
d.
c 20. FT. Mlx °
��-
GROUNDMI ELECTRODE CONDUCTOR
BOLTED -TYPE CONNECTIONDEVICE OR EXOTPERMIC WELD
GROLINDNIG ELECTRODE CONDUCTOR
NONMETALLIC PROTECTIVE SLEEVE
NoA AVG. OR LARGER BARE
COPPER CONDUCTOR OR
° STEEL REINFORCING BAR OR
° ROD NOT LE66 THAN 1/2 INCH
a DIAMETER
ii -
PANEL
150 A
col
tE C IN, t -
1,,
J)1,, � Ute 1 k, :i3 (t1F
,"<t j - 1; Y u F, V1 v' 11_) 1 1
*;111tJ1C'3
-_I CONNECT t0 A CONCRETE -ENCASED ELEr-TRODE CONSISTING
OF At LEAST 20 FT. OF ONE OR MORE BAIRE OR ZINC
GALVAN_I NCH ORIZED STEEL CON5I5TINGROFIAT LEAST
BOAFT. OFRS BARE COPPER 1/2
I_ CONDUCTOR NOT SMALLER THAN No. 4 AND LOCATED WITHIN
-I AND NEAR THE BOTTOM OF A CONCRETE (FOUNDATION OR
LL FOOTING THAT 1$ IN DIRECT CONTACT WITH( EARTH.
ENCASE CaROUND INS ELECTRODE pTL.
3/4"= I'-fd"
PANEL A, E3 4 C CALCULATIONS
ITEM
PANEL A
PANEL B
PANEL C
1
SERVICE
$Q. FT.
5839
3
568
6401
GENERAL LIGHTING
11511•
1
1104•
19221•
$MALL APPLIANCES
1500
9000
1
16500
1/2'
12
GENERAL LIGHTING
15
WASHER
15
1500
!2
GENERAL LIGHTING
15
1
19
1/2'
1600
REFRIGERATOR
15
1500
•
1/2'
12
GENERAL L1(7*HTiNr-s
15
1
1500
DISHWASHER
12
1500
20
1
31
1/2'
12
RECEPTACLE
1500
DISPOSAL
35
800
12
RECEPTACLE
20
1
6
1/2'
800
DOOR MOTOR
20
1
12
1/2'
12
REGI=PTACL!y -
20
3000
30000
HOOD UJ/EXHAUSt
12
1500
20
1
►
1/2'
!2
RECEPTACLE
1500
ICE MAKER
1500
1/2'
12
RECEPTACLE
20
1
0
1/2'
1500
WINE COOLER
1500
1
1500
1/2'
12
SMALL APPLIANGE$
20
1
1500
POOL MOTOR
!2
GF,I. BATH RECEPT.
F120
20
12
12
1/2'
IZ
1500
1500
JACUZZI
1500
1/2'
12
SMOKE DETECTORS
WATER HEATER
1
4000
1/2'
1500
SMALL APPLIANCES
20 1
1
1500
4000
12 1
WINE COOLER
1500
A/C 63
1500
[MICROWAVE
$UB -TOTAL V.A.
29511
19800
6204
56221
lat.10KW10000
60
10000
6204
10000
REST 40%
1801
3920
21
18488
HANDLER UNIT "1
10830
10830
[AIR
AIR HANDLER UNIT "2
23
24
10630
10830
AIR HANDLER UNIT *3
10830
25
26
10830
RANGE
12000
12000 0
DRYER
5000
5000
DEMAND
11801
41150
21864
11918
[AgMPSOEMAND
(VA/240 V)
14
114
29
30
116
325
100
200
150
400
TYPE: SQUARE 'D' QD (OR EQUAL) PANEL A (TYPICAL)
VOLTAGE: 120/240 V. 10 3W.
MOUNTING: FLUSH (ALL 20 AMPS, I POLE CKTS. EXCEPT AS NOTED)
111
�
0
a
O >
pQ
U
1
REMARKS
15
1
3
1/2'
12
GENERAL LIGHTING
15
1
0
1/2'
12
GENERAL LIGHTING
15
1
11
1/2'
12
GENERAL LIGHTING
15
1
15
1/2'
!2
GENERAL LIGHTING
15
1
19
1/2'
12
GENERAL LIGHTING
15
1
•
1/2'
12
GENERAL L1(7*HTiNr-s
15
1
21
!/2'
12
GENERAL LIGHTING
20
1
31
1/2'
12
RECEPTACLE
20
I
35
1/2'
12
RECEPTACLE
20
1
6
1/2'
!2
RECEPTACLE
20
1
12
1/2'
12
REGI=PTACL!y -
20
1
•
1/2'
12
RECEPTACLE
20
1
►
1/2'
!2
RECEPTACLE
20
1
12
1/2'
12
RECEPTACLE
20
1
0
1/2'
12
RECEPTACLE
20
1
1500
1/2'
12
SMALL APPLIANGE$
20
1
•
1/2'
!2
GF,I. BATH RECEPT.
F120
20
12
12
1/2'
IZ
GF.1. BATH REGEPT.
20
1
1500
1/2'
12
SMOKE DETECTORS
20
1
1500
1/2'
12
SMALL APPLIANCES
20 1
1
1500
1/2' 1
12 1
WINE COOLER
CONNECTED LOAD:6EE LOAD CALCULATION
(A/C RATING 22,0000 AMPS)
u
30
u
REMARKS
1
1
2
GENERAL LIGHTING
3
4
GENERAL. LIGHTING
5
6
GENERAL LIGHTING
1
6
GENERAL LIGHTING
9
10
GENERAL LIGHTING
11
12
GENERAL. LIGHTING
13
14
RECEPTACLE
15
16
RECEPTACLE
11
18
RECEPTACLE
19
20
RECEPTACLE
21
22
RECEPTACLE
23
24
RECEPTACLE
25
26
RECEPTACLE
21
28
RECEPTACLE
29
30
SMALL APPLIANCES
31
32
SMALL APPLIANCES
33
34
G.F.I. BATH RECEPT.
35
36
SMOKE DETECTORS
31
38
SMALL APPLIANCES
39
40
ICE MAKER
41
42 1
JACUZZI
Z%:l-;Nc;vm AND SMOKE DETECTOR CIRCUITS TO BE ARC FAULT PROTECTED
E �: 14 . �v i,G� �.���1 is
►1 r r
IIS w .r�Ci� l� 10'40,ljk)r
. ► . r too
MAN: 100 A
FEEDER: !; , THW-CU
CONDUIT.
Z 111 -
0
12 144' • 1 r 15
12 - 1/2,-_--�-- - I 15
30
12
1/2'
1/2'
1
15
I
12
1/2'
DRYER2"8
1
15
5000
12
1/2'
12
1
15
2
12
1/2'
3
1
15
1*10
1
12
1/2'
2
I
20
2
12
1/2'
306
1
20
6
12
1/2'
•
1
20
?0
12
1/2'
12
1
20
12
1/2'
REFRIGERATOR
1
20
1500
12
1/2'
•
1
20
1/2'
12
1/2'
9
1
20
12
1/2'
1
1
20
1
12
1/2'
1500
1
20
12
12
1/2'
1500
1
20
20
12
1/2'
•
1
20
SMALL APPLIANCE$
12
1/2'
SMALL APPLIANCES
1
20
1500
12
1/2'
1500
1
20
1/2'
12
1/2'
1500
1
20
12
12
1/2'
1500
1
20
FEEDER:SEE RISER
FED FROM:SERVICE
TYPE: SQUARE 'D' QD (OR EQUAL) PANEL E3 (TYPICAL) A
MAIN: Z00
VOLTAGE: 120/240 V. 1# 3W. FEEDER: 300 tHW-CU
MOUNTING: FLUSH (ALL 20 AMPS, I POLE CKTS. EXCEPT AS NOTED) CONDUIT: 2'
ul
LL O 0 > 3 Lu w
REMARKS 1- 1- 0 Q
Q- s- REMARKS O > p u
30
2
30000
1/2'
10
WATER HEATER M
I
3
a 2
DRYER2"8
t
3/4'
5000
2
30
12
DOOR MOTOR
50
2
50000 (••)
3/4'
3
4
14
1*10
1
16
16
2
11
50
2
12000
3/4'
306
OVEN/RANGE
5
6
WASHER
24
1/2'
1500
I
?0
1500
1/2
12
POOL EQUIPMENT
30
1 -
8
REFRIGERATOR
12
1/2'
1500
1
20
20
1
15co
1/2'
12
016HWAOHER
9
10
DISPOSAL12
1/2'
800
1
20
20
1
1500
1/2'
12
HOOD W/ EXHA! i$T11
12
MICROWAVE
12
1/2'
1500
1
20
20
1
1500
1/2'
12
SMALL APPLIANCE$
13
14
SMALL APPLIANCES
12
1/2'
1500
1
20
20
1
1500
1/2'
12
SMALL APPLIANCES
15
I6
SMALL APPLIANCES
12
1/2'
1500
1
20
20
1
1500
1/2'
12
SMALL APPLIANCES
11
18
SMALL APPLIANCES
12
1/2'
1500
1
20
50
2
50(.0 0•)
3/4'
2"8
A/C 63
19
10
A.H.U. r'3
2%
3/4'
10830 (••)
2
60
21
22
23
24
25
26
_
21
26
29
30
31
32
33
34
35
36
31
38
39
40
tKl_
42
CONNECTED LOAD:SEE LOAD CALCULATION FEEDER:SEE RISER
(A/C RATING 22,000 AMPS) FED FROM:SERVICE
NOTE. ALL BEDROOM AND SMOKE DETECTOR CIRCUITS TO BE ARC FAULT PROTECTED
51Ji2)EGF (O FL Oli0A
3UILGING COUIE ;'LUS
LOCAL !��EN�0,10 Nis
3Y:�- -- ------ --
TYPE: SQUARE 'D' QD (OR EQUAL) FIANEL G (TYPICAL)
VOLTAGE: 120/240 V- 10 3W.
MOUNTING: FLUSH (ALL 20 AMPS, I POLE CKTS. EXCEPT AS NOTED)
u!
w
U1
0
(L
O >
F
REMARKS
1
REMARKS
15
1
3
1/2'
12
GENERAL LIGHTING
20
1
1500
1/2'
12
DOOR MOTOR
50
2
50000 (••)
3/4'
206
A/C 01
14
2"6
16
16
2
11
50
2
5060 Of)
3/4'
200
A/C *2
22
~
23
24
25
20
1
1500
1/2
12
POOL EQUIPMENT
CONNECTED LOAD:$EE LOAD CALCULATION
(A/C RATING 22,000 AMPS)
l••) AC COMPRESSOR 0 AIR HANDLER UNIT LOADS ARE NOT CONCURRENT.
MAIN: 150 A
FEEDER: 301/0 THW-CU
CONDUIT: 1-1/2'
O }
1-
REMARKS
1
12
2
RECEPTACLE
3
4
DOOR MOTOR
5
(o
A.N.U. 41
1
S
3/4'
9
10
A.H.U. *2
I I
12
13
14
2"6
16
16
2
11
18
19
20
21
22
~
23
24
25
26
21
28
29
30
31
32
33
34
35
36
31
38
39
40
42
41
l••) AC COMPRESSOR 0 AIR HANDLER UNIT LOADS ARE NOT CONCURRENT.
MAIN: 150 A
FEEDER: 301/0 THW-CU
CONDUIT: 1-1/2'
FEEDER:5EE RISER
FED FROM:SERVIGE
O }
1-
W
0
a
0
u
12
1/2'
0
1
20
12
1/2'
1500
1
20
2"6
3/4'
10830 0-)
2
60
L0
2"6
3/4'
108300•)
2
60
FEEDER:5EE RISER
FED FROM:SERVIGE
U)
z
O
0)
W
w
a
r
r
>orc
W
C
mLL
D >
rY
IL (�
W
c Z
O
�0
U
SHEET: E-3
OF: 3
or'`
0)
N
L0
N
O
~
o
o
�
a
w
3Q
0
O
Q
0
U)
z
O
0)
W
w
a
r
r
>orc
W
C
mLL
D >
rY
IL (�
W
c Z
O
�0
U
SHEET: E-3
OF: 3