06-633-013ELECTRICAL 5�1„I CL LIST: 3 W. GROUNDED DUPLEX RECEPTACLE 20 A. 120 V. M.N.+12' AFF. 3 W. GROUNDED SINGLE RECEPTACLE 30 A. 240 V. M.N.+12' AFF. 3 W. GROUNDED SINGLE RECEPTACLE 60 A. 240 V. M.H.+12' AFF. KD PUSH BOTTON JO JUNCTION BOX GIELING OR FLOOR MOUNTED 19 JUNCTION BOX WALL MOUNTED M.H. AS DIRECTED ® VOICE DATA OUTLET M.H. + 12' AFF. OR AS INDICATED [NQi TELEVISION OUTLET M.H.+12' AFF. ifl [I] INTERCOM Q THERMOSTAT M.H. +50' AFF. (REFER t0 A/C DWCx5. FOR LOCATION) 4 MOTOR OUTLET ® ELECTRICAL PANEL ® SWITCH BOARD 13 FUSED D15CONNECTED SWITCH W/ DUAL ELEMENT FU81=5 F65il CIRCUIT BREAKER (HAGR TYPE IF FOR A/C UNIT) _1*1- INCANDESCENT FIXTURE OUTLET GIELING MOUNTED F0 INCANDESCENT FIXTURE OUTLET WALL MOUNTED O RECESSED HI -HAT LIGHT CEILING MOUNTED CEILING FLUORESCENT STRIP FLOODLIGHT SINGLE POLE TOGGLE SWITCH M.H. 50' AFF $3 3 THREE WAY SWITCH M.H. 50' AFF SINGLE POLE SWITCH W/ DIMMER M.H. 50' AFF sp ELECTRICAL SMOKE DETECTOR DEVICE EXHAUST FAN CEILING FAN 1 GROUND FAULT INTERRUPTER Wp• WATER PROOF. Vf'• VAPOR PROOF. ® 240 V. OUTLET ❑O METER 400 AMP METER 221GAIG5 NEMA 3R ELECT. METER 1-1/2'6 3.3/0 TWW-CU 2'0 3.3 THW-CU 1-1/41♦ SIw1;lvICE 2*350 MGi',GU 1+'4/0 MCMCUIN) SIZE GUTTER 70 N.E.C. PANEL 'A" PANEL 'B' IN -3"0 GOND. PVC 313-9,Wb) -° ------~ "2 IN 1' CUND, 12x8xL 100 A 200 A ELECT. SERVICE C.!�.P. SERVICE CONNECT t0 A CONCRETE ENCASED 2"350 MCMCU I ELECTRODE BOND TO A 5/8'x10' GND. RODS 1'4/0 MCMCU(N) (SEE DETAIL) IN -3'0 COND. PVC 6 � GENERAL ELEGTRfGAL NOTES: 1.0 - GENERAL 1.1 - WORK INCLUDED UNDER THIS DIVISION CONSIST OF PROVIDING LABOR MATERIALS, APPLIANCES, EQUIPMENT, TOOLS, TRANSPORTATION, SUPERINTENDENCE AND SERVICES REQUIRED TO CONSTRUCT AND INSTALL COMPLETE AND PROPER OPERATING ELECTRICAL SYSTEMS AS SPECIFIED, INDICATED AND ELSEWHERE REQUIRED 2.0 - EXAMINATION OF SITE 2-1 - BIDDER 15 ADVICED TO VISIT THE SITE AND ACQUAINT HIMSELF WITH WORKING CONDITIONS. CONTRACTOR SHALL ACCEPT CONDITIONS AS THEY EXIST ON BID DATE. 3.0 - MATERIALS 3.1 - MATERIALS, EQUIPMENT AND APPLIANCES SHALL BE NEW AND OF BEST QUALITY UNLESS OTHERWISE INDICATED. 32 - DETERMINE THAT PROPOSED EQUIPMENT CAN BE INSTALLED IN SPACE AVAILABLE. INSTALL EQUIPMENT SO PARTS ARE READILY ACCESSIBLE FOR INSPECTION AND MAINTENANCE EXTRA COMPENSATION WILL NOT BE ALLOWED FOR DISMANTLING EQUIPMENT TO OBTAIN ENTRANCE INTO BLDG. 33 -MATERIALS SHALL BEAR UNDERWRITER'S LABEL WHERE SUCH STANDARDS HAVE BEEN TA LIS HED AND LISTED BY UNDERWRITER'S LABORATORIES INC. 3.4 - MATERIALS, EQUIPMENT AND APPLIANCES SHALL CONFORM TO LATEST STANDARDS OF ; AMCA, $MAGNA, ANSI, A$HRAE, ASME, ASTM, NEMA, ARI AND NFPA. 3.5 - USE EXTREME CARE IN SELECTION AND INSTALATION OF EQUIPMENT TO INSURE THAT NOISE AND VIBRATION ARE HELD TO ABSOLUTE MINIMUM. CORRECT OBJECTIONABLE NOISE AND VIBRATION. PROVIDE ELIMINATORS REQUIRED FOR PROPER RESULTS. 4.0 - PERMITS, FEES AND CODES 4.1 - COST FOR FEES, PERMITS, TESTS NAD INSPECTIONS SHALL BE PAID FOR BY THE CONTRACTOR 4.2 - INSTALLATION SHALL BE IN ACCORDANCE WITH APPLICABLE CODES AND REGULATIONS INCLUDING: F.S.C., N.E.C., NF.P.A., 0.5.HA. AND STATE, COUNTY AND CITY DEPARTMENTS OF HEALTH. 5-0 - COOPERATE WITH OTHER TRADES 5.1 - MAKE KNOWN ARRANGEMENT OF WORK AND CHECK ARRANGEMENT AND LOCATION OF OTHER TRADES TO AVOID CONFLICTS. EXAMINE DRAWINGS OF OTHER TRADES TO DETERMINE EXACT EQUIPMENT LOCATION. 6.0 - OPERATING INSTRUCTIONS 6-1 - CONTRACTOR SHALL PROVIDE TO OWNER OPERATION AND MAINTENANCE MANUALS. REPRESENTATIVE IN OPERATION OF ALL EQUI WNER'S P CONTRACTOR SHALL INSTRUCT OWNER OR OMENT. TYPE WRITTEN LABEL5 SHALL BE PLACED IN PANEL BOXES DESIGNATING CIRCUITS LAYOUTS 1.0 - INSPECTION . 1.1 - NOTIFY OWNER TWENTY-FOUR HOURS IN ADVANCE WHEN PIPING OR EQUIPMENT IS t0 BE TASTED, BEFORE PIPING IS INSULATED OR CONGEALED, AND BEFORE TRENCHES ARE BACKFILLED. 1.2 - FAILING TO COMPLY WITH THE ABOVE, CONTRACTOR $HALL UNCOVER AND RETEST LINES, REPAIRIG DAMAGE TO OTHER CONTRACTOR'S WORK, AS WELL AS HIS OWN. 1.3 -BEFORE REQUESTING FINAL PAYMENT, INSPECT INSTALLATION TO ASSURE THAT WORK 18 COMPLETE AND REQUIREMENTS OF CONTRACT HAVE BEEN FULFILLED. 8.0 - CUTTING AND PATCHING 8.1 - UNLESS OTHERWISE INDICATED, DO NO MORE CUTTING AND PATCHING THAN REQUIRED FOR INSTALLATION OF WORK 82 - CUTTING OF STRUCTURAL MEMBERS OR EXPOSED SUI;;;�FACE OF CONCRETE BLOCK WILL NOT BE PERMITED. 9.0 - MATERIALS AND EQUIPMENT 9.1 - CONDUCTORS SHALL BE THWN COPPER AS NOTED ON DRAWINGS. 92 - RECEPTACLES, SWITCHES AND TELEPHONE OUTLETS SHALL BE AS MANUFACTURED BY LEVITON, HUBBEL OR APPROVED EQUAL. COLOR AND STYLE AS SPECIFIED BY ARCHITECT AND/OR OWNER 9.3 - COMPUTER OUTLETS: (IF APPLICABLE) SHALL BE AS SPECIFIED BY OWNER 9.4 - PANELBOARDS: A. GENERAL: INTERRUPTING CAPACITY RATINGS SHALL BE VERIFIED AND BASED ON THE AVAILABLE SYMMETRICAL FAULT CURRENT GIVEN BY THE POWER COMPANY UPON LOCATION AND INSTALLATfON OF TRANSFORMER B- DIRECTORY: COMPLETE AT END OF JOB, TYPEWRITTEN. C- FINISH: ANSI %I ENAMEL OVER A RUST INHIBITING TREATMENT AFTER FABRICATION AND BEFORE ASSEMBLY. AFTER INSTALLATION, AND BEFORE ACCEPTANCE BY OWNER, ASSEMBLY SHALL BE PAINTED WITH A RUST INHIBITING PAINT ( COLOR SELECTED BY ARCHITECT ) D- NAMEPLATES: PROVIDE A LAMACOID NAMEPLATE WITH 5/16' LETTERS ENGRAVED ON FRONT FACE SHOWING PANEL NAME, VOLTAGE AND PANEL RATING. COORDINATE TO GIVE SAME NAME AS SHOWN ON PANELBOARD SCHEDULE. 9S - FIXTURES: A. THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL LIGHTING FIXTURES AS SPECIFIED ON DRAWING WITH OWNER AND /OR ARCHITECT APPROVAL. VERIFY BEFORE PURCHASE AND INSTALLATION. 9.6- LAMPS: ALL LAMPS USED ON THIS PROJECT SHALL BE NEW, DELIVERED TO THE JOB SITE IN THE ORIGINAL PACKING CASES AND SLEEVES AND SHALL BE OF THE SAME MANUFACTURER UNLESS OTHERWISE SPECIFIED. 9.1 - BALLAST: ALL. BALLAST SHALL BE RATED TO OPERATE AT THE SERVICE VOLTAGE AS SHOWN AND AS SPECIFIED, PLUS OR MINUS THE DEVIATIONS WITH THE ELECTRIC SERVICE COMPANY IS ALLOWED BY FRANCHISE. 10.0 - FUSES A - SUPPLY AND INSTALL ALL FUSES IN EACH FUSED DEVICE. B - ALL AIR CONDITIONING AND KITCHEN EQUIPMENT SHALL BE FUSED AS PER MANUFACTURER'S RECOMENDATION5 AND SPECIFICATIONS. G - INSTALL LABELS IN ALL FUSED DEVIGES INDICATING PROPER SIZE FUSE t0 USE. 11.0 - MISCELLANEOUS 11.1 - ALL EMPTY CONDUIT t0 BE SUPPLIED WITH NYLON PULL WIRE. 11.2 - ALL FLEX CONDUIT SHALL HAVE 'TITE-BITE' CONNECTORS. 113 - ELECTRICAL CONTRACTOR t0 INSTALL AND WIRE OUTLETS IN FIXTURES WHERE SHOWN ON DRAWINGS -OUTLETS TO BE INSTALLED IN FIXTURES AFTER FIXTURES INSTALLATION. 11.4 - ALL DEDICATED CIRCUITS SHALL BE LABELED AS SUCH AT OUTLET. 11.5 - THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING AND VERIFYING THE TELEPHONE COMPANY REQUIREMENTS FOR INSTALLATION OF SERVICE AND ADVISE THE OWNER AND/OR THE ENGINEER OF ANY ADDITIONAL REQUIREMENTS THAT MAY BE NECESSARY. Ilb - THE CONTRACTOR $HALL BE RESPONSIBLE FOR COORDINATING AND VERIFYING THE ELECTRICAL COMPANY'S REQUIREMENTS AND SERVICE ENTRANCE FOR THE BUILDING TO MAIN ELECTRICAL ROOM. ALL OUTLETS PLATE$ SWITCHES ETC. TO BE WHITE. h .ELECTFRIG RISER DlAG;fR/4rj_ N.T.S. CONGSRI�tE PaJINDATION d. c 20. FT. Mlx ° ��- GROUNDMI ELECTRODE CONDUCTOR BOLTED -TYPE CONNECTIONDEVICE OR EXOTPERMIC WELD GROLINDNIG ELECTRODE CONDUCTOR NONMETALLIC PROTECTIVE SLEEVE NoA AVG. OR LARGER BARE COPPER CONDUCTOR OR ° STEEL REINFORCING BAR OR ° ROD NOT LE66 THAN 1/2 INCH a DIAMETER ii - PANEL 150 A col tE C IN, t - 1,, J)1,, � Ute 1 k, :i3 (t1F ,"<t j - 1; Y u F, V1 v' 11_) 1 1 *;111tJ1C'3 -_I CONNECT t0 A CONCRETE -ENCASED ELEr-TRODE CONSISTING OF At LEAST 20 FT. OF ONE OR MORE BAIRE OR ZINC GALVAN_I NCH ORIZED STEEL CON5I5TINGROFIAT LEAST BOAFT. OFRS BARE COPPER 1/2 I_ CONDUCTOR NOT SMALLER THAN No. 4 AND LOCATED WITHIN -I AND NEAR THE BOTTOM OF A CONCRETE (FOUNDATION OR LL FOOTING THAT 1$ IN DIRECT CONTACT WITH( EARTH. ENCASE CaROUND INS ELECTRODE pTL. 3/4"= I'-fd" PANEL A, E3 4 C CALCULATIONS ITEM PANEL A PANEL B PANEL C 1 SERVICE $Q. FT. 5839 3 568 6401 GENERAL LIGHTING 11511• 1 1104• 19221• $MALL APPLIANCES 1500 9000 1 16500 1/2' 12 GENERAL LIGHTING 15 WASHER 15 1500 !2 GENERAL LIGHTING 15 1 19 1/2' 1600 REFRIGERATOR 15 1500 • 1/2' 12 GENERAL L1(7*HTiNr-s 15 1 1500 DISHWASHER 12 1500 20 1 31 1/2' 12 RECEPTACLE 1500 DISPOSAL 35 800 12 RECEPTACLE 20 1 6 1/2' 800 DOOR MOTOR 20 1 12 1/2' 12 REGI=PTACL!y - 20 3000 30000 HOOD UJ/EXHAUSt 12 1500 20 1 ► 1/2' !2 RECEPTACLE 1500 ICE MAKER 1500 1/2' 12 RECEPTACLE 20 1 0 1/2' 1500 WINE COOLER 1500 1 1500 1/2' 12 SMALL APPLIANGE$ 20 1 1500 POOL MOTOR !2 GF,I. BATH RECEPT. F120 20 12 12 1/2' IZ 1500 1500 JACUZZI 1500 1/2' 12 SMOKE DETECTORS WATER HEATER 1 4000 1/2' 1500 SMALL APPLIANCES 20 1 1 1500 4000 12 1 WINE COOLER 1500 A/C 63 1500 [MICROWAVE $UB -TOTAL V.A. 29511 19800 6204 56221 lat.10KW10000 60 10000 6204 10000 REST 40% 1801 3920 21 18488 HANDLER UNIT "1 10830 10830 [AIR AIR HANDLER UNIT "2 23 24 10630 10830 AIR HANDLER UNIT *3 10830 25 26 10830 RANGE 12000 12000 0 DRYER 5000 5000 DEMAND 11801 41150 21864 11918 [AgMPSOEMAND (VA/240 V) 14 114 29 30 116 325 100 200 150 400 TYPE: SQUARE 'D' QD (OR EQUAL) PANEL A (TYPICAL) VOLTAGE: 120/240 V. 10 3W. MOUNTING: FLUSH (ALL 20 AMPS, I POLE CKTS. EXCEPT AS NOTED) 111 � 0 a O > pQ U 1 REMARKS 15 1 3 1/2' 12 GENERAL LIGHTING 15 1 0 1/2' 12 GENERAL LIGHTING 15 1 11 1/2' 12 GENERAL LIGHTING 15 1 15 1/2' !2 GENERAL LIGHTING 15 1 19 1/2' 12 GENERAL LIGHTING 15 1 • 1/2' 12 GENERAL L1(7*HTiNr-s 15 1 21 !/2' 12 GENERAL LIGHTING 20 1 31 1/2' 12 RECEPTACLE 20 I 35 1/2' 12 RECEPTACLE 20 1 6 1/2' !2 RECEPTACLE 20 1 12 1/2' 12 REGI=PTACL!y - 20 1 • 1/2' 12 RECEPTACLE 20 1 ► 1/2' !2 RECEPTACLE 20 1 12 1/2' 12 RECEPTACLE 20 1 0 1/2' 12 RECEPTACLE 20 1 1500 1/2' 12 SMALL APPLIANGE$ 20 1 • 1/2' !2 GF,I. BATH RECEPT. F120 20 12 12 1/2' IZ GF.1. BATH REGEPT. 20 1 1500 1/2' 12 SMOKE DETECTORS 20 1 1500 1/2' 12 SMALL APPLIANCES 20 1 1 1500 1/2' 1 12 1 WINE COOLER CONNECTED LOAD:6EE LOAD CALCULATION (A/C RATING 22,0000 AMPS) u 30 u REMARKS 1 1 2 GENERAL LIGHTING 3 4 GENERAL. LIGHTING 5 6 GENERAL LIGHTING 1 6 GENERAL LIGHTING 9 10 GENERAL LIGHTING 11 12 GENERAL. LIGHTING 13 14 RECEPTACLE 15 16 RECEPTACLE 11 18 RECEPTACLE 19 20 RECEPTACLE 21 22 RECEPTACLE 23 24 RECEPTACLE 25 26 RECEPTACLE 21 28 RECEPTACLE 29 30 SMALL APPLIANCES 31 32 SMALL APPLIANCES 33 34 G.F.I. BATH RECEPT. 35 36 SMOKE DETECTORS 31 38 SMALL APPLIANCES 39 40 ICE MAKER 41 42 1 JACUZZI Z%:l-;Nc;vm AND SMOKE DETECTOR CIRCUITS TO BE ARC FAULT PROTECTED E �: 14 . �v i,G� �.���1 is ►1 r r IIS w .r�Ci� l� 10'40,ljk)r . ► . r too MAN: 100 A FEEDER: !; , THW-CU CONDUIT. Z 111 - 0 12 144' • 1 r 15 12 - 1/2,-_--�-- - I 15 30 12 1/2' 1/2' 1 15 I 12 1/2' DRYER2"8 1 15 5000 12 1/2' 12 1 15 2 12 1/2' 3 1 15 1*10 1 12 1/2' 2 I 20 2 12 1/2' 306 1 20 6 12 1/2' • 1 20 ?0 12 1/2' 12 1 20 12 1/2' REFRIGERATOR 1 20 1500 12 1/2' • 1 20 1/2' 12 1/2' 9 1 20 12 1/2' 1 1 20 1 12 1/2' 1500 1 20 12 12 1/2' 1500 1 20 20 12 1/2' • 1 20 SMALL APPLIANCE$ 12 1/2' SMALL APPLIANCES 1 20 1500 12 1/2' 1500 1 20 1/2' 12 1/2' 1500 1 20 12 12 1/2' 1500 1 20 FEEDER:SEE RISER FED FROM:SERVICE TYPE: SQUARE 'D' QD (OR EQUAL) PANEL E3 (TYPICAL) A MAIN: Z00 VOLTAGE: 120/240 V. 1# 3W. FEEDER: 300 tHW-CU MOUNTING: FLUSH (ALL 20 AMPS, I POLE CKTS. EXCEPT AS NOTED) CONDUIT: 2' ul LL O 0 > 3 Lu w REMARKS 1- 1- 0 Q Q- s- REMARKS O > p u 30 2 30000 1/2' 10 WATER HEATER M I 3 a 2 DRYER2"8 t 3/4' 5000 2 30 12 DOOR MOTOR 50 2 50000 (••) 3/4' 3 4 14 1*10 1 16 16 2 11 50 2 12000 3/4' 306 OVEN/RANGE 5 6 WASHER 24 1/2' 1500 I ?0 1500 1/2 12 POOL EQUIPMENT 30 1 - 8 REFRIGERATOR 12 1/2' 1500 1 20 20 1 15co 1/2' 12 016HWAOHER 9 10 DISPOSAL12 1/2' 800 1 20 20 1 1500 1/2' 12 HOOD W/ EXHA! i$T11 12 MICROWAVE 12 1/2' 1500 1 20 20 1 1500 1/2' 12 SMALL APPLIANCE$ 13 14 SMALL APPLIANCES 12 1/2' 1500 1 20 20 1 1500 1/2' 12 SMALL APPLIANCES 15 I6 SMALL APPLIANCES 12 1/2' 1500 1 20 20 1 1500 1/2' 12 SMALL APPLIANCES 11 18 SMALL APPLIANCES 12 1/2' 1500 1 20 50 2 50(.0 0•) 3/4' 2"8 A/C 63 19 10 A.H.U. r'3 2% 3/4' 10830 (••) 2 60 21 22 23 24 25 26 _ 21 26 29 30 31 32 33 34 35 36 31 38 39 40 tKl_ 42 CONNECTED LOAD:SEE LOAD CALCULATION FEEDER:SEE RISER (A/C RATING 22,000 AMPS) FED FROM:SERVICE NOTE. ALL BEDROOM AND SMOKE DETECTOR CIRCUITS TO BE ARC FAULT PROTECTED 51Ji2)EGF (O FL Oli0A 3UILGING COUIE ;'LUS LOCAL !��EN�0,10 Nis 3Y:�- -- ------ -- TYPE: SQUARE 'D' QD (OR EQUAL) FIANEL G (TYPICAL) VOLTAGE: 120/240 V- 10 3W. MOUNTING: FLUSH (ALL 20 AMPS, I POLE CKTS. EXCEPT AS NOTED) u! w U1 0 (L O > F REMARKS 1 REMARKS 15 1 3 1/2' 12 GENERAL LIGHTING 20 1 1500 1/2' 12 DOOR MOTOR 50 2 50000 (••) 3/4' 206 A/C 01 14 2"6 16 16 2 11 50 2 5060 Of) 3/4' 200 A/C *2 22 ~ 23 24 25 20 1 1500 1/2 12 POOL EQUIPMENT CONNECTED LOAD:$EE LOAD CALCULATION (A/C RATING 22,000 AMPS) l••) AC COMPRESSOR 0 AIR HANDLER UNIT LOADS ARE NOT CONCURRENT. MAIN: 150 A FEEDER: 301/0 THW-CU CONDUIT: 1-1/2' O } 1- REMARKS 1 12 2 RECEPTACLE 3 4 DOOR MOTOR 5 (o A.N.U. 41 1 S 3/4' 9 10 A.H.U. *2 I I 12 13 14 2"6 16 16 2 11 18 19 20 21 22 ~ 23 24 25 26 21 28 29 30 31 32 33 34 35 36 31 38 39 40 42 41 l••) AC COMPRESSOR 0 AIR HANDLER UNIT LOADS ARE NOT CONCURRENT. MAIN: 150 A FEEDER: 301/0 THW-CU CONDUIT: 1-1/2' FEEDER:5EE RISER FED FROM:SERVIGE O } 1- W 0 a 0 u 12 1/2' 0 1 20 12 1/2' 1500 1 20 2"6 3/4' 10830 0-) 2 60 L0 2"6 3/4' 108300•) 2 60 FEEDER:5EE RISER FED FROM:SERVIGE U) z O 0) W w a r r >orc W C mLL D > rY IL (� W c Z O �0 U SHEET: E-3 OF: 3 or'` 0) N L0 N O ~ o o � a w 3Q 0 O Q 0 U) z O 0) W w a r r >orc W C mLL D > rY IL (� W c Z O �0 U SHEET: E-3 OF: 3