10-797-011v V • • • ••• f/i• • i • ii••• " Y ..64 9 GENERAL 1. THE STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH THE DRAWINGS OF ALL OTHER DISCIPLINES AND THE SPECIFICATIONS FOR THIS PROJECT, THE CONTRACTOR SHALL VERIFY THE REQUIREMENTS OF OTHER TRADES AS TO SLEEVES, CHASES, HANGERS, INSERTS, ANCHORS, HOLES AND OTHER ITEMS TO BE PLACES OR SET IN THE STRUCTURAL WORK. THE CONTRACTOR SHALL COORDINATE WITH ALL TRADES ALL ITEMS THAT ARE TO BE INTEGRATED INTO THE STRUCTURAL SYSTEM. ORDER OF CONSTRUCTION TO BE THE RESPONSIBILITY OF THE CONTRACTOR. HE SHALL PROVIDE ALL ITEMS NECESSARY FOR HIS CHOSEN PROCEDURE. 2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH ALL SAFETY PRECAUTIONS AND REGULATIONS DURING THE WORK. ALL CONSTRUCTION SHALL BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE STANDARDS OF OSHA, CHAPTER 33 OF THE IBC 2006, AND LOCAL ORDINANCES AND CODES. THE ENGINEER WILL NOT ADVISE ON NOR ISSUE DIRECTION AS TO SAFETY PRECAUTIONS AND PROGRAMS. 3. THE STRUCTURAL DRAWINGS HEREIN REPRESENT THE FINISH STRUCTURE. THE CONTRACTOR SHALL PROVIDE ALL TEMPORARY GUYING AND BRACING REQUIRED TO ERECT AND HOLD THE STRUCTURE IN PROPER ALIGNMENT UNTIL ALL STRUCTURAL WORK AND CONNECTIONS HAVE BEEN COMPLETED. THE INVESTIGATION, DESIGN, SAFETY, ADEQUACY AND INSPECTION OF ERECTION BRACING, SHORING, TEMPORARY SUPPORTS, ETC. IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR. 4. THE ENGINEER SHALL NOT BE RESPONSIBLE FOR THE METHODS, TECHNIQUES AND SEQUENCES OF PROCEDURES TO PERFORM THE WORK. THE SUPERVISION OF THE WORK IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR. OBSERVATION VISITS TO THE SITE BY THE STRUCTURAL ENGINEER SHALL NOT BE CONSTRUED AS INSPECTION, NOR AS APPROVAL OF CONSTRUCTION. 5. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT SPECIFICALLY SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED, SUBJECT TO APPROVAL BY THE ENGINEER. 6. ALL STRUCTURAL SYSTEMS WHICH ARE TO BE COMPOSED OF COMPONENTS TO BE FIELD ERECTED SHALL BE SUPERVISED BY THE SUPPLIER DURING MANUFACTURING, DELIVERY, HANDLING, STORAGE AND ERECTION IN ACCORDANCE WITH THE SUPPLIER'S INSTRUCTIONS AND REQUIREMENTS. 7. LOADING APPLIED TO THE STRUCTURE DURING THE PROCESS OF CONSTRUCTION SHALL NOT EXCEED THE SAFE LOAD - CARRYING CAPACITY OF THE STRUCTURAL MEMBERS. THE LIVE LOADINGS USED IN THE DESIGN OF THIS STRUCTURE ARE INDICATED IN THE "DESIGN CRITERIA NOTES". DO NOT APPLY ANY CONSTRUCTION LOADS UNTIL STRUCTURAL FRAMING IS PROPERLY CONNECTED TOGETHER AND UNTIL ALL TEMPORARY BRACING IS IN PLACE. 8. ALL REFERENCED CODES AND STANDARDS ARE PER THE LATEST EDITIONS OF THESE STANDARDS AS ADOPTED BY THE LOCAL JURISDICTION, UNLESS OTHERWISE NOTED, THESE CODES AND STANDARDS ARE CONSIDERED PART OF THE CONSTRUCTION DOCUMENTS BY REFERENCE. 9. SHOP DRAWINGS AND OTHER ITEMS SHALL BE SUBMITTED TO THE ENGINEER FOR REVIEW PRIOR TO FABRICATION, ALL SHOP DRAWINGS SHALL BE REVIEWED BY THE GENERAL CONTRACTOR BEFORE SUBMITTAL. THE ENGINEER'S REVIEW IS TO BE FOR CONFORMANCE WITH THE DESIGN CONCEPTS AND GENERAL COMPLIANCE WITH THE RELEVANT CONTRACT DOCUMENTS. THE ENGINEER'S REVIEW DOES NOT RELIEVE THE CONTRACTOR OF THE SOLE RESPONSIBILITY TO REVIEW, CHECK AND COORDINATE THE SHOP DRAWINGS PRIOR TO SUBMISSION. THE CONTRACTOR REMAINS SOLELY RESPONSIBLE FOR ERRORS AND OMISSIONS ASSOCIATED WITH THE PREPARATION OF SHOP DRAWINGS AS THEY PERTAIN TO MEMBER SIZES, DETAILS, DIMENSION, ETC. ALLOW TWO WEEKS FOR SHOP DRAWING REVIEW. 10. ANY DEVIATION FROM THE CONTRACT DOCUMENTS SHALL BE APPROVED BY THE ENGINEER & SHALL BE SO DOCUMENTED. THIS DOCUMENTATION SHALL BECOME PART OF THE CONTRACT DOCUMENTS. DEVIATION FROM THE CONTRACT DOCUMENTS SHALL NOT BE ALLOWED ON SHOP DRAWINGS, WITHOUT A SPECIFIC STATEMENT IN THE FORM OF A COVER LETTER DESCRIBING THE PROPOSED DEVIATION, & REQUESTING APPROVAL. THE CONTRACTOR SHALL REVIEW & VERIFY ALL SHOP DRAWINGS TO ASSURE THEY COMPLY W/ REQUIREMENTS OF THE CONTRACT DOCUMENTS. THE ENGINEER WILL REVIEW THE SHOP DRAWINGS FOR GENERAL CONFORMANCE W/ DESIGN CONCEPT. THIS REVIEW BY THE ENGINEER SHALL NOT BE CONSTRUED AS APPROVAL. 11. SUBMIT SHOP DRAWINGS IN THE FORM OF FOUR SETS OF PRINTS AND ONE SET OF REPRODUCIBLE DRAWINGS TO BE USED AS SHOP DRAWINGS. AS A MINIMUM, SUBMIT THE FOLLOWING ITEMS FOR REVIEW: 11.1. STRUCTURAL STEEL SHOP DRAWINGS. 11.2. METAL DECKING SHOP DRAWINGS. 11.3. LIGHT GAUGE STEEL FRAMING. STRUCTURAL STEEL 1. STRUCTURAL STEEL SHALL HAVE THE FOLLOWING MATERIALS UNLESS NOTED OTHERWISE. WIDE FLANGE SECTIONS ASTM A992 (50 ksi) OTHER ROLLED SHAPES AND PLATES ASTM A36 STRUCTURAL STEEL TUBES ASTM A500 GRADE B (46 ksi) STRUCTURAL STEEL PIPES ASTM A53, TYPE E or S GRADE 3 HEADED STUD ANCHORS (HAS) ASTM A307 WITH ASTM A563 HEAVY HEX BOLTED CONNECTIONS ASTM A325 THREADED ROD ASTM A307 ANCHOR BOLTS ASTM A307 NUTS ASTM A563 (heavy hex) WASHERS GRADE A (hardened) 2. THE FABRICATION AND CONSTRUCTION OF ALL STRUCTURAL STEEL SHALL COMPLY WITH THE LATEST EDITION OF THE FOLLOWING CODES: IBC 2006 SECTION 2205 AISC SPECIFICATIONS FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL BUILDINGS. AISC CODE OF STANDARD PRACTICE EXCLUDING SECTIONS 3,4, 4.4, AND 4.4.1. AISC SPECIFICATIONS FOR STRUCTURAL JOINTS. AWS WELDING CODE, PROVIDE SHOP DRAWINGS FOR REVIEW PRIOR TO FABRICATION, ALL SHOP FABRICATION BE BY AISC-APPROVED FABRICATORS. 3. ALL STRUCTURAL WELDING SHALL CONFORM WITH THE FOLLOWING SPECIFICATIONS: WELDING RODS E-70 XX (typical) E-60 XX (roof decks) STRUCTURAL WELDING AWS D1.1 WELDS NOT PART OF SLRS AWS D1.8 ALL WELDS PART OF SLRS AWS 1.8 DC ALL DEMAND CRITICAL WELDS PART OF THE SLRS ALL WELDS PERFORMED BY AWS CERTIFIED WELDER. STRUCTURAL CUTTING AWS CERTIFIED WELDER HSA's/DBA's MANUFACTURERS SPECIFICATIONS 4. ANY SUBSTITUTION OF ANY MEMBERS SHALL BE AT THE WRITTEN CONSENT OF THE STRUCTURAL ENGINEER. 5. ANY CONNECTIONS OF INTERSECTING STEEL MEMBERS NOT SPECIFIED ON THE DRAWINGS SHALL BE A FILLET WELD AND SHALL BE SIZED BY SUBTRACTING 1/16" LESS THAN THE THINNEST CONNECTING MEMBER WITH A MINIMUM OF A 3/16" FILLET WELD. ALL WELDS SHALL BE FULL SURFACE WELDS. CONTACT THE SER REGARDING ANY UNSPECIFEID CONNECTIONS 6. ALL WELDING SHALL MEET REQUIREMENTS OF J2 AISC 360. 7. ALL STRUCTURAL CONNECTIONS, SHOWN IN THE PLANS, SHALL BE BOLTED WITH A MINIMUM OF A 314" DIAMETER ASTM A325N BOLT, UNLESS NOTED OTHERWISE AND SHALL BE TIGHTENED TO A SNUG TIGHT FIT, AS DEFINED BY AISC SPECIFICATIONS. S. HARDENED WASHERS SHALL BE PROVIDED AT ALL TURNED ELEMENTS OF BOLTED CONNECTIONS. IF THE CONNECTION IS SLOPED OR SKEWED THEN PROVIDE BEVELED WASHERS AS REQUIRED. PROVIDE WASHERS THAT COMPLETELY COVER ANY OVERSIZED HOLES OR SLOTS ER ASTM F-436. 9. TIGHTEN ALL SLIP -CRITICAL BOLTS, MOMENT FRAME BOLTS AND BOLTS INSTALLED IN OVERSIZED OR SLOTTED HOLES BY THE "TURN OF THE NUT" OR THE "DIRECT TENSION" METHOD. PROVIDE HARDENED WASHERS UNDER ALL TURNED ELEMENTS. PRETENSION BOLTS PER TABLE J311 OF AISC 360. 10. WHERE ASTM A490 OR STRONGER BOLTS ARE SPECIFIED IN THE DRAWINGS, BOTH THE BOLT HEAD AND THE NUT SHALL HAVE A HARDENED WASHER BETWEEN IT AND THE BASE STEEL AND REQUIRED IN AISC SPECIFICATIONS. 11. BOLTS MUST BE LONG ENOUGH FOR THREADS TO RE FLUSH WITH THE OUTSIDE FACE OF THE BOLT AFTER TIGHTENING. NO MORE THAN 5 THREADS OF "STICKOUT" ARE PERMITTED. THE "TURN OF THE NUT" METHOD IS DESCRIBED BELOW (THIS IS FOR PERPENDICULAR SURFACES ONLY): 11.1 THE TURN OF THE NUT METHOD IS NOT TO RE USED FOR BOLTS LONGER THEN 12 BOLT DIAMETERS. TIGHTEN ALL BOLTS IN THE CONNECTION TO THE SNUG, TIGHT CONDITION. FROM THE SNUG, TIGHT CONDITION, TIGHTEN EACH BOLT AS SPECIFIED BELOW: BOLT LENGTH: AMOUNT OF TURN APPLIED TO NUT. UP TO AND INCLUDING 1/3 TURN OF THE NUT 4 DIAMETERS OVER 4 DIAMETERS 1/2 TURN OF THE NUT BUT NOT EXCEEDING I DIAMETERS OVER 8 DIAMETERS 2/3 TURN OF THE NUT BUT NOT EXCEEDING 12 DIAMETERS 12. DO NOT REUSE BOLTS, NUTS OR WASHERS. 13. FITTED STIFFENER PLATES SHALL BE PROVIDED AT ALL BEARING LOCATIONS AND SHALL MEET THE FOLLOWING REQUIREMENTS UNLESS NOTED OTHERWISE IN THE DRAWINGS: FLANGE WIDTH STIFFENER PLATE THICKNESS FILLET WELD THICKNESS UP TO 1" 3/8" 1 /4" V to 12" 3/8" 114" 12" to 16" 1 /2" 5/16" 16" AND BIGGER 518" 3/8" 14. HOLES IN STEEL SHALL BE DRILLED OR PUNCHED. ALL SLOTTED HOLES SHALL BE PROVIDED WITH SMOOTH EDGES. BURNING OF HOLES AND TORCH CUTTING AT THE SITE IS NOT PERMITTED. 15, THE STRUCTURAL STEEL ERECTOR SHALL PROVIDE ANY REQUIRED TEMPORARY GUYING AND BRACING REQUIRED. COLUMNS, ANCHOR BOLTS, BASE PLATES, ETC. HAVE BEEN DESIGNED FOR THE FINAL COMPLETED CONDITION AND HAVE NOT BEEN INVESTIGATED FOR POTENTIAL LOADINGS ENCOUNTERED DURING STEEL ERECTION AND CONSTRUCTION. ANY INVESTIGATION OF THE COLUMNS, ANCHOR BOLTS, BASE PLATES, ETC.. FOR ADEQUACY DURING THE STEEL ERECTION AND CONSTRUCTION PROCESS IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR. 16. REFER TO THE "SPECIAL INSPECTION" SECTION OF THE GENERAL STRUCTURAL NOTES FOR ANY INSPECTION REQUIREMENTS. METAL DECKING 1. ALL METAL DECK SHALL BE MANUFACTURED AND ERECTED IN ACCORDANCE WITH THE LATEST REQUIREMENTS OF THE STEEL DECK INSTITUTE. 2. STEEL ROOF DECK SHALL NOT SUPPORT SUSPENDED CEILINGS, LIGHT FIXTURES, HVAC DUCTS, PLUMBING OR ANY OTHER ARCHITECTURAL ELEMENTS UNLESS SPECIFIED OTHERWISE. 3. WHERE THE DECK IS TO RECEIVE SPRAYED ON FIRE PROOFING, THE SURFACE SHALL PREPARED PROPERLY SO THAT THE FIREPROOFING ADHERES TO THE PAINTED DECK. 4. ALL DECK SUPPORTS SHALL BE DRY PRIOR TO FASTENENING THE DECK. 5. PRIOR TO WELDING INTERLOCKING SEAMS OR BUTTON PUNCHING, STEEL DECK SHALL BE CRIMPED PER THE MANUFACTURERS SPECIFICATIONS. 6. THE YIELD STRESS OF ANY 22 GAUGE STEEL DECK SHALL BE LIMITED TO A MAXIMUM OF 50 ksi. 7. ALL DECK SHALL SPAN A MINIMUM OF 3 CONTINUOUS SPANS. WHERE THE 3-SPAN CONDITION CAN NOT BE MET, THE CONTRACTOR SHALL PROVIDE A HEAVIER GAUGE DECK SO AS TO PROVIDE AN EQUIVALENT LOADING TO THE 3-SPAN CONDITION SPECIFIED. 8. STEEL ROOF DECK 8.1. STEEL ROOF DECK SHALL BE 1 1/2" DEEP, GALVANIZED TYPE "B" WIDE RIB DECK WITH INTERLOCKING SIDE SEAMS WITH THE FOLLOWING PROPERTIES: 20 GAUGE MINIMUM S (in^3/ft)= 0.23510.248 B MINIMUM I (in^41ft)= 0,216 8.2. ROOF DECK SHALL HAVE A MINIMUM DIAPHRAGM SHEAR CAPACITY 0 C7#�b�, ft. FORA 4'-O" ECK SPAN. 2.3. PROVIDE A MINIMUM OF 2 INCHES OF BEARING AND LAP AT THE SPLICE POINT . 9.4. THE CONTRACTOR MAY SUBMIT FOR APPROVAL, THE MANUFACTURERS ICC REPORT OF AN ALTERNATIVE METHOD OF DECK ATTACHMENT. THE ALTERNATE METHOD SHALL PROVIDE MINIMUM DECK DIAPHRAGM SHEAR VALUES EQUAL TO OR GREATER THAN THOSE NOTED ABOVE. THE ENGINEER OF RECORD SHALL APPROVE ANY ALTERNATE METHODS PRIOR TO SUBSTITUTION. WOOD SHEATHING NOTES 1. ALL PLYWOOD CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE AMERICAN PLYWOOD ASSOCIATION (APA) SPECIFICATIONS. 2. ALL MEZZANINE FLOOR PANEL SHEATHING SHALL BE APA RATED SHEATHING. THE SHEATHING EDGES SHALL BE TONGUE AND GROOVE. FLOOR SHEATHING SHALL BE FASTENED TO STEEL DECK Wl #10 PAN HEAD TEK SCREWS @ 6"o.c. EDGE NAILING AND 12"o.c. IN THE FIELD. COLD -FORMED STEEL FRAMING 1. THE FABRICATION AND ERECTION OF ALL COLD -FORMED METAL FRAMING SHALL COMPLY WITH THE REQUIREMENTS OF AISC "MANUAL OF STEEL CONSTRUCTION", AWS "STRUCTURAL WELDING CODE", AND AISI "SPECIFICATION FOR THE DESIGN OF COLD FORMED STEEL STRUCTURAL MEMBERS". 2. LIGHT GAUGE STEEL FRAMING (LGSF): 2.1. FOLLOW ALL MANUFACTURERS RECOMMENDATIONS FOR THE USE OF THESE PRODUCTS. ALL LGSF SHALL BE MANUFACTURED FROM GALVANIZED STEEL. 2.2. GALVANIZED STEEL MUST MEET THE MINIMUM REQUIREMENTS OF ASTM A446 GRADE D (Fy = 50 ksi) FOR 12,14,16 AND 1$ GAUGE MATERIAL, AND ASTM A446 GRADE A (Fy = 33 ksi) FOR 20 GAUGE AND LIGHTER. GALVANIZED COATINGS MUST MEET THE ASTM A525 SPECIFICATIONS. 2.3. ALL SIZES INDICATED ON PLANS ARE EITHER AISI OR SSMA NOMENCLATURE. LGSF SHALL MEET OR EXCEED PROPERTIES OF SPECIFIED ELEMENTS. 2.4. ALL WELDS SHALL BE MADE IN ACCORDANCE WITH AWS D1.3-0$. WELDING PROCEDURES SHALL BE PRE -QUALIFIED AND WELDERS CERTIFIED TO THOSE PROCEDURES USED ON THIS PROJECT, ALL SCREWS SHALL BE #8 OR #10 PAN HEAD SCREWS. 2.5. ALL COLD FORMED STEEL WALL STUDS SHALL HAVE TWO ROWS OF HORIZONTAL BRIDGING. BRIDGING USED FOR ERECTION PURPOSES ONLY SHALL BE LEFT IN PLACE. WALL STUDS SHEATHED ON BOTH SIDES SHALL BE FASTENED TO SHEATHING WITH MIN #i SCREW @ 12" 0-C. SHEAR WALL STEEL SHEETING SHALL BE FASTENED WITH PAN HEAD SCREWS, MIN FASTENERS #10 @ 6" 0-C EDGE FASTENING, 12" 0-C "FIELD" FASTENING. 2.6. FLOORS FRAMED W/ LIGHT GAUGE STEEL JOISTS SHALL BE SHEATHED ON ONE SIDE W/ A WOOD OR METAL DIAPHRAGM L BRACED W/ INTERNAL BRIDGING PER DETAILS. STATEMENT OF SPECIAL INSPECTION SPECIAL INSPECTION AND QUALITY ASSURANCE, AS REQUIRED BY SECTION 1704 OF THE IBC, SHALL BE PROVIDED BY AN INDEPENDENT AGENCY EMPLOYED BY THE OWNER UNLESS WAIVED BY THE BUILDING OFFICIAL. THE CONTRACTOR SHALL COORDINATE AND COOPERATE WITH THE REQUIRED INSPECTIONS. ALL TESTING AND INSPECTION REPORTS SHALL BE SENT TO THE ENGINEER OF RECORD FOR REVIEW. REPORTS SHALL MEET THE REQUIREMENTS OF IBC SECTION 1704.1.2. ITEMS REQUIRING SPECIAL INSPECTION ARE: 1. STRUCTURAL STEEL FABRICATION: 1.1. VERIFICATION OF STRUCTURAL STEEL MATERIAL, BOLTS, WASHERS, AND WELD MATERIAL. 12. NOTE IDENTIFICATION MARKINGS CONFORMING TO ASTM, MANUFACTURES CERTIFICATE OF COMPLIANCE, AND MANUFACTURES MILL REPORTS. 1.3. SHOP WELDING: ALL SHOP WELDING SHALL BE INSPECTED IN ACCORDANCE WITH SECTION 1704.3.1.1, AWS D1.3, AND 1707.1 2. STRUCTURAL WELDING (FIELD) IBC SECTION 1704.3 2.1. PERIODIC SPECIAL INSPECTION OF SINGLE PASS FILLET WELDS LESS THAN OR EQUAL TO 5/16". 2.2. CONTINUOUS SPECIAL INSPECTION OF SINGLE PASS FILLET WELDS GREATER THAN 5/16" AND MULTI -PASS FILLET WELDS. 2.3. CONTINUOUS SPECIAL INSPECTION OF COMPLETE AND PARTIAL PENETRATION WELDS. 2.4. PERIODIC INSPECTION OF FLOOR AND ROOF DECK WELDING. 3. HIGH STRENGTH BOLTED CONNECTIONS IBC SECTION 1704.3.3 3.1. GENERAL PER 1704.3.3.1: 3.1.1. REVIEW REQUIREMENTS FOR BOLTS, NUTS, WASHERS, PAINT BOLTED PARTS AND INSTALLATION, TIGHTENING SUCH THAT STANDARDS ARE MET. 3.1.2. CONFIRM PLYS ARE PROPERLY SNUG AND MONITOR INSTALLATION OF BOLTS TO VERIFY THAT THE SELECTED PROCEDURE FOR INSTALLATION IS PROPERLY USED. 3.1. PERIODIC SPECIAL INSPECTION PER 1704.3.3.2 3.2. CONTINUOUS SPECIAL INSPECTION PER 1704.3.3.3. 4. COLD FORMED STEEL FRAMING: 4.1. WELDING INSPECTION SHALL CONFORM TO AWS D1.3, 4.2. PERIODIC SPECIAL INSPECTION OF SCREW ATTACHMENTS, BOLTING, ANCHOR DEVICES, AND OTHER FASTENING COMPONENTS WITHIN THE LATERAL FORCE RESISTING SYSTEM, (IDENTIFIED ON THE DRAWINGS). 5. EPDXY ANCHORS CBC TABLE 1704.4 POST INSTALLED ANCHORS 5.1. SPECIAL INSPECTIONS SHALL VERIFY ALL DRILLED HOLES DIAMETER, DEPTH, AND PREPARATION PRIOR TO INSTALLATION OF EPDXY AND ANCHOR ROD. A STRUCTURAL OBSERVATION SHALL BE PERFORMED AND A WRITTEN REPORT SHALL BE SUBMITTED IN ACCORDANCE WITH IBC SECTION 1709.1 i 1709.2. THE SPECIAL INSPECTIONS ARE REQUIRED BY THE IBC CODE SECTION 1704. DESIGN LOADS & CRITERIA DESIGN CODES BUILDING CODE 2007 ASCE 7-051 FLORIDA IC 2007 STRUCTURAL STEEL AISC 13thEDITION STEEL DECK SDI LIGHT GAUGE STEEL FRAMING AISI 2004 SEISMIC OCCUPANCY CATEGORY (ASCE 7-05 TABLE 1-1) II IBC SEISMIC IMPORTANCE FACTOR (ASCE 7-05 TABLE 11.5.1) IE 1.0 MAPPED SPECTRAL RESPONSE ACCELERATION: SITE CLASS (SEE ASCE 7-05 TABLE 9.4.1.2, PER ASCE 7-05, USE CLASS D UNLESS OTHER INFORMATION IS PROVIDED) D DESIGN SPECTRAL RESPONSE ACCELERATION PARAMETERS Sos 0.040 Sol 0.022 SEISMIC DESIGN CATEGORY (ASCE 7-0511.6) A BASIC SEISMIC -FORCE RESISTING SYSTEM, SEE ASCE 7-05 TABLE 12.2.1 ORDINARY STEEL MOMENT FRAMES: RESPONSE MODIFICATION FACTOR R = 3.0 OVERSTRENGTH FACTOR no 3.0 ANALYSIS PROCEDURE USED. (ASCE 7-05 EQUIVALENT LATERAL FORCE PROCEDURE SECTION 124): SEISMIC RESPONSE COEFFICIENT - ULTIMATE Cs= 0.010 SEISMIC RESPONSE COEFFICIENT - ALLOWABLE Cs= 0.0071 WIND IBC SIMPLIFIED METHOD PER SECTION 1609.6 WIND SPEED (3 SECOND GUST) 145 M.P.H. EXPOSURE CATEGORY C WIND IMPORTANCE FACTOR (ASCE 7-05 TABLE 6.1) IW= 1.0 ROOF DEAD LOAD 12 P.S.F. + 25 P.S.F. @ GRN ROOF ROOF SNOW LOAD (VALUES SHOWN DO NOT INCLUDE DRIFT, OR UNBALANCED LOADS,) P 9 = 0 P.S.F. Pf = 0 P.S.F. INTERIOR STORY WIND/SEISMIC DRIFT (h = story ht) DM < 0.025 * h / P O • ii i• 1. J4 • V• •• •Y i • U • MARKS & ABBREVIATIONS "• ` L •" O N AB ANCHOR BOLT •• Z •••�. ��.� " ACI AMERICAN CONCRETE INSTITUTE ` (� . • � ADJ ADJACENT " • L- • Q! i " 4 " i • „ • Y • • • " • RISC AMERICAN INSTITUTE OF STEEL CONSTRUCTION U "gas • w • AISI AMERICAN IRON & STEEL INSTITUTE : ALT ALTERNATE, APA AMERICAN PLYWOOD ASSOCIATION W CK ARCH ARCHITECT 0� ASTM AMERICAN SOCIETY OF TESTING MATERIALS L AWSA AMERICAN WELDING SOCIETY C N O BF-X BRACED FRAME MARK (� U BLDG BUILDING N BLW BELOW BM BEAM BOT BOTTOM BRG BEARING BTWN BETWEEN COL COLUMN CONC CONCRETE CONT CONTINUOUS CBC CALIFORNIA BUILDING CODE DBA DEFORMED BAR ANCHOR DBE DECK BEARING ELEVATION DBL DOUBLE DIET DETAIL DIA DIAMETER DIM DIMENSION DL DEAD LOAD DWG DRAWING DWL DOWEL E EXISTING EA EACH E.F. EACH FACE E.J. EXPANSION JOINT EL EARTH QUAKE LOAD ELEV ELEVATION EQ EQUAL E.W. EACH WAY EXP EXPANSION EXT EXTERIOR FC-X FOOTING CONTINUOUS MARK FND FOUNDATION Z FL FLOOR 0 FM-X MAT FOOTING MARK FR-X RECTANGULAR FOOTING MARK 11 FS-X SQUARE FOOTING MARK 0� FTG FOOTING FTS-X THICKENED SLAB FOOTING MARK GA GAUGE W GAL GALVANIZED 12 Z GLB GLUE LAMINATED BEAM Ur (D Uj GR GRADE Z Z 2 GIRT GROUT 0 GSN GENERALSTRUCTURALNOTES HB HORIZONTAL BRIDGING 0 U HDG HOT DIP GALVANIZED HORIZ HORIZONTAL HSA HEADED STUD ANCHOR ICBO INTERNATIONAL CONFERENCE OF BUILDING OFFICIALS IBC INTERNATION BUILDING CODE I.F. INTERIOR FACE IN. INCH INT INTERIOR JST JOIST ; K KIP = 1000 POUNDS KLF KIPS PER LINEAL FOOT KSF KIPS PER SQUARE FOOT t �� LBS POUNDS LF LINEAL FOOT LGSF LIGHT GAUGE STEEL FRAMING LL LIVE LOAD " MAX MAXIMUM H,, MECH MECHANICAL � MF-X MOMENT FRAME O MIN MINIMUM Q MISC MISCELLANEOUS k' NTS NOT TO SCALE Q.C. ON CENTER O.F. OUTSIDE FACE" OPP OPPOSITE PL PLATE ' PLF POUNDS PER LINEAL FOOTr PSF POUNDS PER SQUARE FOOT a; PSI POUNDS PER SQUARE INCH PSL PARALAM BEAM REINF REINFORCING REQ'D REQUIRED R.D. ROOF DRAIN SAD SEE ARCHITECTURAL DRAWINGS SBP-X STEEL BASE PLATE SC-X STEEL COLUMN MARK SCP-X STEEL CAP PLATE M SER STRUCTURAL ENGINEER OF RECORD E SHT SHEET SI SPECIAL INSPECTION SIM SIMILAR 3u IL i%!G DEPT; SJI STEEL JOIST INSTITUTE `'`TPUC'TUR SL SNOW LOAD L si=CitOv SQ SQUARE SSMA STEEL STUD MANUFACTURES ASSOCIATION STAG STAGGERED '� PF:pyrp By, STD STANDARD-.., STIFF STIFFENER STL STEEL " STR STRUCTURAL STSDS SELF TAPPING SELF DRILLING SCREWS T&B TOP AND BOTTOM DRAWN BY: TEMP TEMPERATURE N. Tanner THK THICKNESS T.O. TOP OF CHECKED BY: TOC TOP OF CONCRETE TOD TOP OF DECK J. Crilly TOF TOP OF FOOTING TOW TOP OF WALL SCALE: TYP TYPICAL 12 1.R0�� UNO UNLESS NOTED OTHER ISE, VERT VERTICAL DATE: VIF VERIFY IN FIELD11 Aug 2010 W/ WITH h WL WINDLOAD,R �, PROJECT NO: WT WEIGHT 10031 •,f rrfil �`3�t��, \tg.(\ SHEET: ISSUED FOR PERMIT 11 Aug 2010 ENGINEER SEAL Drawing No: S001 NOTE: THE UNDERSIGNED IS NOT THE ENGINEER OF RECORD FOR THE OVERALL PROJECT. a J N �- nE CU O � n O b U) Z 0 H U 0 U) Q DO oc m 10 ' 00 N sTooCO �•d 0 00 C0 ♦� O � co _O O V w Q I