12-224-025FLUuIBING F1><TURE SC�4EDULE
SYMBOL
FIXTURE TYPE
SR�
C.W.
H.W.
DESCRIPTION
SHOWER HEAD
WATER CL05ET
3'
tie'
-
6.5 gallons per cycle or less
(Energy Star/Water Sense Certified)
0
LAVATORY
1112'
1124
1,2'
L6
®
BATH TU15
2'
tie'
'
w/ ANTI -SCALD VALVE
SHOWER
2'
tie'
tie'
w/ ANTI—SCALD VALVE
❑ ❑
KITCHEN SINK
11/2'
11/2'
1�2
w/ GARBAGE DISPOSAL
%��
D ISNWASNER
_
t,2
D ISGHARGE INTO GARF3AGE
DISPOSAL UNIT.
WASHING MACHI.
2'
t'/2'
t/2'
L/
U_
S-�
Q
FIN. FLR_
SECTION VIEW
FOR
CLARITY.
NOTE: ALL DRRAIN PIPING UNDER SLAB SHALL BE 2' MIN
2' 4 LESS DIA DRAIN 6 1/4' DROP
3' 4 4' DIA DRAIN e 1/8' DROP
WALL
'ZURN'
*ZN-1400-5P—T—VP
FLOOR CLEANOUT.
FACE OF WALL.
STAINLESS STEEL COVER
SCREWED TO THREADED
C.O. PLUG.
'ZURN' *Z-1446—BP—VP
FOR EXPOSED BLOCK
AND GYPSUM BOARD
WALLS. 'ZURN'
*ZN-144-I-5P-VP FPR TILE
WALLS. 'ZURN'
*ZN-1448-5P-VP FOR
PLASTER WALLS.
CONCRETE PAD
2'x2'x8' W/ 4* 3EW.
COMPACTED
FILL
ELEVATION VI
�— TWO-WAY CLEANOUT TEE
OR LONG SWEEP QUARTER
BEND.
NOTE: REFER TO SPECIFICATIONS FOR
MATERIALS
AND REQUIREMENTS FOR INSTALLATION.
CLEANOUT DETAIL5 N.T.5.
'ZURN' *Z-1404-VPIRON
BOX W/ COVER MARKED
'C.O.'
FIN. GRADE
TO
GRADE
FILL VOIDS W/
OILED SAND.
CLEANOUT
FITTING W/
BRASS PLUG.
501L/WATER T,45LE 51TE
VALUATION CRITERIA NT5
'GUY GRAY' MODEL T-200 DRAIN
BOX. MOUNT 42' A.F.F. OR A5
DIRECTED 13Y ARCHITECT.
NOTE: DRAIN PIPING SHALL
SLOPE NO LESS THAN
1/4' PER FOOT.
--------------------------�
I ]
I ]
I 9
I
I
I
I
I
I
I
I
I
I 0
e I
I
I
I
I
I
I
I
I
m I
I I
I I
I I
L--------- ---------J
2' DRAIN PIPE.
3' TRAP SEAL
REMOVEABLE
TRAP
WASHING MACHINE DRAIN BOX
N.T.S.
WATER CONSUL-lf 'TION IN
FLUM1 INC FIXTUF:
FITTINGS
MAXIMUM FLOW RATE
WATER CLOSETS
1.28 << gallons per flushing cycle
LAVATORY
1.0 << gpm at 60 psi
SHOWER HEAD
1.5 << gpm at 80 psi
SINK FAUCET
1.0 <,< gpm at 60 psi
DISHWASHER
6.5 gallons per cycle or less
(Energy Star/Water Sense Certified)
WASHING MACHINE
Water factor of 8 or lower
(Energy Star/Water Sense Certified)
fL U1*'I1B 1Nr_:; NOTE5
GENERAL
PROVIDE ( FURNISH AND INSTALL ) ALL NECESSARY
MATERIALS AND LABOR FOR A COMPLETELY OPERATIONAL
PLUMBING SYSTEM AS SHOWN ON THE DRAWINGS AND
HEREIN SPECIFIED. INSTALL IN ACCORDANCE WITH THE
FLORIDA BUILDING CODE AND LOCAL ORDINANCES.
ecoPE or- WORK
PROVfDE THE FOLLOWING COMPLETE SYSTEMS :
;,-- =A. SANITARY COLLECTION.
B. DOMESTIGOT ANE;C-OLD WATER
C. AIR CONDITIONING CONDENSATE.
PAY FOR', ALL Z=EES, INSPECTIONS AND CONNECTION
CHARGES REQUIRED
VERIFY AT JOB SITE ALL SPACE CONDITIONS, DIMENSIONS
WITH PIPE, FIXTURES, AND EQUIPMENT SIZES PRIOR TO
FABRICATIONORINSTALLATION.COORDINATE REQUIREMENTS
TO ,OVOID INTERFERENCE WITH OTHER TRADES.
SUBMIT SHOP DRAWINGS FOR ARCHITECT / ENGINEER
APPROVAL BEFORE PROCEEDING WITH THE PURCHASE OR
INSTALLATION OF EQUIPMENT AND MATERIALS.
GUARANTEE ALL WORK FREE OF DEFECTS IN MATERIALS
AND WORKMANSHIP FORA PERIOD OF ONE YEAR FROM
DATE OF ACCEPTANCE.
FLUI-151NG LEGENID
m0
CTG-
WCO II
FD
PT
v�—
V
SANITARY SEWER LINE
VENT L INE
CONDENSATE DRAINAGE LINE
CLEANOUT TO GRADE
WALL CLEANOUT
FLOOR DRAIN
COLD WATER (C.W.) LINE
HOT WATER (H.W.) LINE
PRESS. 4 TEMP. RELIEF LINE
GATE VALVE
CHECK VALVE
MATERIALS
PROVIDE SHUT-OFF VALVES FOR EACH FIXTURE Atop ,-SIR
CHAMBERS WHERE SHOWN AND WHERE REQUIRED FOR
PROPER PERFORMANCE OF THE SYSTEM.
PROVIDE DIELECTRIC FITTINGS TO CONNECT PIPING TO
EQUIPMENT OF DISSIMILAR METALS. USE CLAMPS ANI:'
FASTENERS OF SIMILAR METALS OR ISOLATE THL..`°f FROM
PIPING AND SLABS TO PREVENT CORROSION.
PIPING
DOMESTIC HOT ANDCOLD WATER: PVC TUBING TYPE
SANITARY WASTE AND VENT; PVC PIPING
A/C CONDENSATE: PVC 5GEDULE 40 PIPE AND FITTINGS.
P.V.C. DRAIN PIPE AND FITTINGS MAY BE USED WHEN
ALLOWED BY THE LOCAL JURISDICTION.
VB
VIV
VTR
AFF
• FE
-�- FEC
— ® FCO
O LHW TO FIXTURES
TITAN
5CR-3 IN 120
TANKLESS
WATER HEATER
FROM SERV.
COLD WATER
STANDARD ............ ........................ANZIZ, 10.03
DIMENSIONS— .......... . ........ . .. . .... I0'X1'X2.15'
WEIGHT. 8 POUNDS
MATERIALS.._................_.._......_...._.BRASS CASING
PIPE FITTING.—. ----........._............3/4' STANDARD PIPE
PRESSURE REQUIREMENT5.......5 P8I—MINA50 PSI—MAX.
VOLTAGE......_........._......220 VAC STD. (208/211 AVAIL.)
ELEMENTS-..____._ ___..._...DUAL INCOLOY/NICHROME
ENERGY EFFICIENCY ------ ...._- .91
MODEL
MAX.
KW at 220 V
VOLTS
MAX.
AMPS at 220 V
SCR -3
12 KW
220 V
120
TEMPERATURE CHART "F
MODEL
1 GPM
1.5 GPM
2 GPM
3 GPM
4 GPM
SCR -3
109°
13"
55"
36"
21"
WATER HEATER DETAIL
N.T.S.
UNION
HOSE 5155
VACUUM BREAKER
VALVE IN VERTICAL
VENT THRU ROOF
ABOVE FINISHED FLOOR LEVEL
FIRE EXTINGU15HER ON WALL BRACKET (2A-I05C)
FIRE EXTINGUISHER IN CABINET (2A -105c)`
FLOOR CLEAN OUT
PRESS. 4 TEMP. RELIEF VALVE
LOT 17
r
�ti••M,A
M
�na4'
Q
m
1 1
L6
J
OO Ufa
W
0
z
A
:a
N04ktl'
Wr�
L/
U_
S-�
Q
z
Fug°.
L6
z
W
a
}as
Z
Z
O
CL a
W
C*
z`
9
k.
G
�f34
06
✓U� t e
s
`. 0
r
�ti••M,A
REVISIONS
36-
a, -
DATE :FEBRUARY, 2012
SCALE' SNOUN
DRAWN. M. CASTELLON
DESIGN Blf JR
JOB NO
P-2
M
L6
J
Y.
W
0
z
W
Wr�
J
Q
J
L6
z
W
a
}as
Z
Z
O
CL a
W
C*
z`
9
k.
G
�f34
06
✓U� t e
s
`. 0
n4 t
REVISIONS
36-
a, -
DATE :FEBRUARY, 2012
SCALE' SNOUN
DRAWN. M. CASTELLON
DESIGN Blf JR
JOB NO
P-2