12-224-014STRUCTURAL NOTES: COORDINATION: -COORDINATE ALL DIMENSIONS, ELEVATIONS d OPENINGS WITH ARCHITECTURAL DRAWINGS, REPORT ANY DI5CREPANCIE5 TO OUR OFFICE. FOUNDATIONS: -SOIL STATEMENT- VISUAL INSPECTION OF THE 51TE 5HOW5 A 501L OF LIMESTONE WITH SANDY POCKETS AND WITH A LAYER OF TOPSOIL, TH15 LIMESTONE HAS A SAFE BEARING CAPACITY IN EXCESS OF 2000 p5F. AT THE TIME OF GONSTRUGTION A LICENSED ARCHITECT OR POFE55IONAL ENGINEER SHALL SUBMIT TO THE BUILDING OFFICIAL A LETTER ATTESTING THAT THE 51TE HAS BEEN OBSERVED AND THE FOUNDATIONS CONDITIONS ARE SIMILAR TO THOSE UPON WHICH THE DESIGN 15 BASED - 0 ILDING ASED_ BUILDING PAD PREPARATION- -TREES, BRUSH, ROOTS, TOPSOIL, RUBBLE, ORGANICALLY CONTAMINATED OR OTHERWISE OBJECTIONABLE MATERIALS ENCOUNTERED ARE TO BE REMOVED FROM STRUCTURAL AREAS OF THE SITE. FOR A MINIMUM DISTANCE OF FIVE FEET OUT5IDE STRUCTURE PERIPHERY. -EXISTING GROUND BENEATH STRUCTURE FOUNDATION SHALL PROOF ROLLED. AREAS EXHIBITING INSTABILITY ARE TO BE UNDERCUT AND BACKFIELD AND COMPACTED. -THE PROPOSED ENGINEERED FILL MATERIALS ARE TO BE PLACED IN LIFT5 NOT EXCEEDING EIGHT (0) INCHES LOOSE MEASURED THICKNESS IN UNCONFINED LIFTS OR 6" IN CONFINED AREAS. EACH LIFT IS TO BE COMPACTED AS FOLLOWS: I.- SLAB ON GRADE: MINIMUM OF 95% MAXIMUM DENSITY BY ASTM p1551. 2.- FOOTING BEARING: MINIMUM OF 95`o MAXIMUM DENSITY 15Y ASTM p1551. TERMITE PROTECTION: A5 PER F.B.C. 105.11 BUILDING COMPONENTS AND BUILDING SURROUNDINGS REQUIRED TO BE -PROTECTED FROM TERMITE DAMAGE IN ACCORDANCE WITH 503AA, 1804.6.2.1, 1910 ,1,5, 2304 OR 2603.3, OR REQUIRED To HAVE CHEMICAL SOIL TREATMENT IN ACCORDANCE WITH 1816 SHALL NOT E3E COVERED OR CONCEALED UNTIL THE RELEASE FROM THE BUILDING OFFICIALHAS BEEN RECEIVED. ALL BUILDINGS SHALL HAVE PRE -CONSTRUCTION TREATMENT PROTECTION AGAINST - SUBTERRANEAN TERMITES A5 PER F.B.G. 1816.1.1. A CERTIFICATE OF COMPLIANCE SHALL BE 155UED TO THE BUILDING DEPARTMENT BY THE LICENSED PEST CONTROL COMPANY THAT CONTAINS THE FOLLOWING STATEMENT: "THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES. TREATMENT 15 IN ACCORDANCE WITH THE RULES AND LAWS ESTABLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES" CONCRETE: -COMPRESSIVE STRENGTH AT 20 DAYS: SLAB ON FILL: 3000 P51 ALL OTHER POURED -IN-PLACE CONCRETE: 3000 PSI GROUT: 3000 PSI -TEST: A MIN. OF D CONCRETE SPECIMENS SHALL BE TAKEN FROM EACH 50 CU, YD, OR F'ORTION THERE=OF 5PECIMEN5 SHALL BE TESTED ACCORDING TO A,S,T.M, C-39, ONE AT 3, ONE AT 1, AND 3 AT 28 DAYS. -COVER: CONCRETE DEPOSITED AGAINST THE GROUND: _3" FORMED CONCRETE IN CONTACT WITH THE GROUND: -2" BEAMS AND COLUMNS: _1-11211 INTERIOR SLABS: 3/4" EXTERIOR 5LABS�— SLAB ON FILL: (PLACED ACCORDING TO AGI 302) -JOINTS: ISOLATION JOINTS MUST BE USED AT JUNCTIONS WITH WALLS AND COLUMNS, USE 1/2" THICK PREMOLDED JOINTS FULL DEPTH OF SLAB. CONTROL JOINTS PLACED AT CENTERLINE OF COLUMN 1-INE5 PROVIDE INTERMEDIATE JOINTS IF COLUMN SPACING IS GREATER THAN 30'. IN SIDEWALKS PROVIDE TOOLED JOINTS SPACED AT INTERVALS EQUAL TO THE WIDTH OF THE SLAB, 4" 8 5" SLAB5: 111 DEEP TOOLED JOINTS MUST BE SAWED BEFORE 24 HOURS AFTER CONCRETING. CONSTRUCTION JOINTS MUST BE PLACED IN THE SLAB WHERE BUILDING EXPANSION JOINTS ARE SHOWN AND WHERE CONTROL JOINTS ARE SHOWN. WHEN CONCRETING AND OPERATING ARE CONCLUDED FOR THE DAY, CONSTRUCTION JOINTS SHALL BE FORMED WITH BURKE KEYED KOLD METAL JOINT FORM OR APPROVED EQUAL, -VAPOR BARRIERS: WATERPROOF MEMBRANES (OVERLAPPED 6" AT JOINTS) WITH A PERMEANCE OF LESS THAN 0.3`0 PERMS IN ACCORDANCE WITH A,5.T.M, E -9a 5HALL BE PROVIDED UNDER INTE=RIOR SLAB, WHERE NO VAPOR BARRIER 15 USED THE 5UBGRADE MUST BE DAMPENED WITH WATER IN ADVANCE OF CONCRETING NO FREE WATER STANDING ON THE SUBGRADE NOR ANY MUDDY OR SOFT SPOT 15 PERMITTED. -ANY STRUCTURAL MEMBER PENETRATING SLAB ON FILL 15 TO BE 1/2" PRE -MOLDED JOINT FILLER COMPLYING WITH A.S.T.M. D-1152, TYPE I. -FINISHING: NO PREMATURE FINISHING SHALL BE ALLOWED. IMMEDIATE FOLLOWING FLOATING TROWELING WITH STEEL TROWELS SHOULD BE COMMENCED IF REQUIRED GROOMING SHALL GE AFTER THE STEEL TROWELING OPERATION. -SLAB FINISHES: (UNLESS OTHERWISE NOTED BY THE ARCHITECT) BUILDING: _STEEL TROWELED OUTSIDE SLAB: _—BROOMED REINFORCING 5TEEL: � -REINFORCING BARS CONFORMING TO A.S.T.M. A-615 GRADE 60, INCLUDING COLUMN AND BEAM TIES. U) -WELDED FIRE FABRIC CONFORMING TO A.5.T.M. A-105 AND SUPPORTED ON SLAB BOLSTERS SPACED AT 3'-0" O/C. -FABRICATION AND DE=TAILING ACCORDING TO A.C.I.-315. `D -ALL ACCESSORIES To HAVE UPTURNED LEGS AND BE PLASTIC DIPPED AFTER FABRICATION. o STRUCTURAL STEEL: -ALL STRUCTURAL STEEL PLATES, ANGLES, M, 5, C MC 5HAPE5 SHALL CONFORM TO 14.5.T.M. A-36, -ALL STRUCTURAL STEEL WELDING SHALL BE PERFORM WITH A,W.5. D.i.i, J -ALL ANCHOR BOLTS SHALL CONFORM To A.S.T,M. A-301. C) -ALL BOLTS SHALL CONFORM TO A,S.T.M. A-325, -ALL SQUARE/RECTANGULAR COLUMNS SHALL CONFORM TO 4,&,T,M, 14-500, GRADE C (fy = 46 KSI). i -PROVIDE ONE SHOP COAT OF RUST INHIBITING PAINT MIN. 3 ML, DRY FILM THICKNESS). X -FABRICATIONS AND ERECTIONS SHALL BE PONE IN ACCORDANCE WITH THE LATEST o A.I.S.C. SPECIFICATIONS. v WELDING: o -ALL WELDING SHOULD BE PERFORMED IN ACCORDANCE WITH THE REQUIREMENTS SET FORTH BY A.W.S. BY CERTIFIED WELDERS. 0 -CONTRACTORS TO USE E-10 5ERIE5 LOW HYDROGEN ELECTRODES. TIMMR: -ALLLJ015T5 AND IRAFTER5 SHALL HAvF A MIN. STRESS GRADE OF Fb - 1200 P51, E=1,100,000 P51 (SOUTHERN YELLOW FINE=). -TRUSS MANUFACTURER TO SUBMIT SIGNED AND SEALED SHOP DRAWINGS AND CALCULATIONS FOR APPROVAL INDICATING ALL REACTIONS TO THE SUPPORTING STRUCTURE. PRE -FABRICATED WOOD TRU58E5 -SHALL BE DESIGNED AND FABRICATED IN ACCORDANCE WITH THE TRUSS PLATE INSTITUTE (T.P.I.), LATEST EDITION. TRUSSES TO BE ERECTED FOLLOWING THE GUIDELINES OF THE T.P.I. PUBLICATION BWT-16, SUBMIT LAYOUT PLAN AND INDIVIDUAL DRAWINGS FOR EACH DIFFERENT TRUSS, SIGNED AND SEALED BY A FLORIDA REGISTERED PROFESSIONAL ENGINEER, FOR APPROVAL BY STRUCTURAL ENGINEER PRIOR TO FABRICATION. v -GENERAL CONTRACTOR TO PROVIDE PERMANENT LATERAL BRACING OF THE BOTTOM CHORD AND THE WEB MEMBERS IN ACCORDANCE WITH RECOMMENDATIONS OF T.P.I. GWT-76 AND THE REQUIREMENTS OF THE INDIVIDUAL TRUSS DESIGNS, SUBMIT PERMANENT GRACING PLAN FOR APPROVAL BY ENGINEER PRIOR TO ERECTION, GIRDER TRU55E5 TO BE BOLTED TOGETHER WITH 1/2" DIA. DOLTS AT 24" C/C AT TOP CHORD, BOTTOM CHORD, AND WEB MEMBERS. -CONTRACTOR TO SUBMIT SIGNED AND SEALED SHOP DRAWINGS BY A DELEGATED SPECIALTY ENGINEER FOR ALL TRU55 TO TRUSS CONNECTIONS, TRU55 MANUFACTURER TO VERIFY UPLIFT AND nRAVITY TRUSS REACTIONS SHOWN ON FRAMING PLANS. -ALL TRUSSES AND/OR JOIST SHALL BE SECURED TO THE BEARING PARTITIONS OR THE BEAMS WITH a HURRICANE 6TRAP5,45 INDICATED ON PLANS, 5TA6GER TRUS5ED AS REQUIRED TO ACHIEVE PROPER BEARING (4" MIN.). -PROVIDE AN 10 GAGE= METAL STRAP TO TIE DOWN ALL THE "PIGGY BACK" TRUSSES TO THE MAIN N TRUSSES AT ALL THE BEARING POINTS, ELECTRICAL CONDUITS -WHERE REINFORCING STEEL CONGESTION PERMITS, CONDUIT AND PIPES UP TO I" DIAME=TER MAY BE EMBEDDED IN CONCRETE PER ACI 310, SECTION 6.3, SPACE AT 3 DIAMETERS O.C. PLACE BETWEEN OUTER LAYERS OF REINFORCING IF CONDUITS ARE SIGNIFICANTLY CONGESTED, ADDITIONAL z REINFORCING PERPENDICULAR TO PIPING MAY BE REQUIRED. REQUESTS TO EMBED LARGER PIPES SHOULD BE ACCOMPANIED BY A DETAILED DESCRIPTION AND BE SUBMITTED TO THE ARCHITECT FOR EVALUATION. SHOP DRAWING SUBMITTALS: 'z SUBMIT FIVE. PRINTS OF ALL SHOP DRAWINGS LISTED BELOW. IF SIGNED AND ` 5EALED SHOP DRAWINGS ARE REQUIRED, THEN SUBMIT TWO ADDITIONAL SIGNED AND SEALED z PRINTS FOR APPROVAL. J -SHOP DRAWINGS: REINFORCING 5TE:F-L. STRUCTURAL STEEL. CONCRETE MIX DESIGN. a ROOF TRUSSES MASONRY WALLS: -BEARING MASONRY SHOWN THUS IN PLAN SHALL_ BE ERECTED PRIOR TO THE STRUCTURE ABOVE HA5 BEEN POURED. -NON-BEARING MASONRY SHOWN THUS IN PLAN SHALL BE ERECTED AFTER THE STRUCTURE ABOVE HAS BEEN POURED. -MORTAR CONFORMING TO A.S.T.M, C-210 TYPE "M" (2500 PSI). -PROVIDE 9 GAGE LADDER TYPE HORIZONTAL REINFORCEMENT AT 16" O/C (FOR REINFORCED WALLS). -PROVIDE 9 GAGE TRU55 TYPE HORIZONTAL REINFORCEMENT AT 16" O/C (FOR NON -REINFORCED WALL5) -WHENEVER ANCHORS BOLTS ARE TO BE SET IN MASONRY. TWO CELLS AT THE SETTING LOCATION SHALL BE FILLED WITH CONCRETE. -GROUT FOR MASONRY UNITS SHALL CONFORM TO A5TM C416 -PRIMS STRENGTH OF MASONRY UNITS SHALL BE MINIMUM OF F'm = 1500 PSI. (F'c = 1900 PSI) -MAXIMUM POUR LIFT FOR MASONRY UNITS AND GROUT POUR HEIGHT SHALL BE 4'-0" -GROUT FOR FILLED CELLS SHALL HAVE A MIN. COMPRESSIVE STRENGTH OF 3000 PSI WITH A SLUMP OF 9" TO 11'' -CONCRETE BLOCKS SHALL BE C-90 TYPE, PLACED IN RUNNING BONDS. DESIGN CRITERIA: (SUPERIMPOSED LOADS) -LIVE LOAD: 30 PSF (ROOF) -DEAD LOAD: 20 PSF (ROOF) 30 PSF (LIVING AREAS) -WIND LOAD: PER A.S.C.E, 1-05 CATEGORY: JE EXPOSURE - "C" IMPORTANCE: 1.00 WIND VELOCITY: 146 MPH MEAN ROOF HEIGHT: 24.1' GCP1: 0.1a (ENCLOSED) 0.55 (PARTIALY ENCLOSED) OWNER, ARCHITECT, AND CONTRACTOR NOTE- -CHECK FOR SHOP DRAWINGS AND INSPECTIONS OF REINFORCEMENT IN THE FIELD ARE REQUIRED IF THIS OFFICE IS TO BE HELD RE5PONSI5LE FOR THE 5TRUCTUR4L ADEQUACY OF THE CONSTRUCTED BUILDING. �:C�l:�P'`��'..QQ :�I�'_n_f �i�r(�Z�i 7.._T3T3•�P -ALL SHORING, RE -SHORING AND TEMPORARY BRACING REQUIRED IN TH15 PROJECT 15 'CO BE DESIGNED BY FLORIDA PROFESSIONAL ENGINEER WHO SPECIALIZES IN FORM WORK/TEMPORARY BRACING DESIGN. AND WHO HAS BEEN HIRED BY THE GENERAL CONTRACTOR. THE GENERAL CONTRACTOR IS THE ULTIMATE RE5PON5I5LE PARTY FOR SHORING, RE -SHORING, AND TEMPORARY BRACING REQUIRED ON THIS PROJECT AND MUST SATISFY HIMSELF WITH THE ADEQUACY OF THE INSTALLATION OF THESE ITEMS AT ALL TIMES. IN THE SPECIFIC CASE OF POURED 5LA85 IT 15 HIGHLY RECOMMENDED THAT THE GENERAL CONTRACTOR SECURE FROM THE SHORING DESIGNER A CERTIFICATION OF THE INSTALLED SHORING PRIOR TO THE PLACEMENT OF CONCRETE. SAFETY OSHA AND LABOR LAWS. -THE STRUCTURE 15 DESIGNED TO BE SELF-SUPPORTING AND STABLE AFTER THE BUILDING 15 FULLY COMPLETED. IT 15 THE CONTRACTOR'S SOLE= RESPONSIBILITY TO DETERMINE ERECTION PROCEDURE AND SEQUENCE AND INSURE THE SAFETY OF THE BUILDING AND ITS COMPONENT PARTS DURING ERECTION. THIS INCLUDES THE ADDITION OF WHATEVER SHORING, TE=MPORARY BRACING, ETC. THAT MAY BE NECCE5ARY, SUCH MATERIAL SHALL REMAIN THE CONTRACTOR'S PROPERTY AFTER COMPLETION OF THE PROJECT. -THE STRUCTURAL ENGINEER OF RECORD DOES NOT POSSES, NOR PRESUMES TO POSSES ANY KNOWLEDGE OR EXPERTISE IN MATTERS TO JOB 51TE EMPLOYEE SAFETY, OSHA OR LABOR LAW REQUIREMENTS FORA CONSTRUCTION PROJECT. SAFETY AND COMPLIANCE WITH OSHA AND LABOR LAWS ARE THE ABSOLUTE RESPONSIBILITY OP THE GENERAL CONTRACTOR AND THOSE CON5ULTANT5 HE HIRES TO ADDRESS THESE MATTERS, THE STRUCTURAL ENGINEER OF RECORD SPEGIALIZE5 IN STRUCTURAL DESIGN ONLY, AND THE BOARD OF PROFE551ONAL REGULATION FORBIDS HIM FROM ASSUMING RESPONSIBILITY OUTSIDE HIS AREA OF EXPERTISE APPLICABLE CODES: IN MY PROFE56IONAL JUDGE=MENT AND THE BEST OP MY KNOWLEDGE: AND BELEIF, THESE PLANS AND SPECIFICATIONS COMPLY WITH THE: FLORIDA BUILDING CODE. -ALTHOUGH THE ENGINEER OF RECORD HAS STRIVED TO MEET ALL APPLICABLE CODES AND LOCAL ORDINANCE REQUIREMENTS, THE CONTRACTOR 15 STILL RESPONSIBLE FOR COMPLYING WITH ALL APPLICABLE CODES AND ORDINANCES IN THE EVENT OF CONFLICT OR OVERSIGHT IN THE DRAWINGS THE CONTRACTOR MUST IMMEDIATELY NOTIFY THE ARCHITECT OR ENGINEER OF ANY CONFLICT OR D15CREPANCY ENCOUNTERED SO THAT APPROPRIATE REMEDIES MAY BE UNDERTAKEN. -THE APPLICABLE CODES ARE: FLORIDA BUILDING CODE, LATEST EDITION.(2001 W/2009 6UPLEMENT5) A.G.I. 31a BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE, A.C.I. 530 BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES. (2008 EDITION) NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION. (2005 EDITION) A.LS.C. MANUAL, 13th. EDITION. P.C.I. DESIGN HANDBOOK STANDARD HOOK ROOF OR COLUMN TERMINATION PT. DOUBLE TIES (3" C.C.) OFFSET #a AND LARGER BARS ONLY o FINISH FLOOR OR INTERMEDIATE TIE BEAM SEE PLAN DOUBLE TIES (3" C.C. AT BEND POINT) - JOINT J-2 EL. SEE PLAN VAPOR BARRIER SEE SPEC5, WELL COMPACTED FILL 3 TIES 03" — (p OF COLUMN AND FOOTING (U.O,N. IN PLAN) 3 TIES a3" m_ 1~ 0 lu z (n ua A CONCRETE SLAB, SEE PLAN FOR THICKNE55 AND REINFORCING d }- U DOWE=LS SAME SIZE 6 • NUMBER AS VERT. REINF. (SET TO CLEAR BARS _ 311 STANDARD ABOVE) Gl_R, HOOK FOR FOOTING SIZE AND REINFORCING, 5EE SCHEDULE I.- USE 03 TIES FOR #10 VERTICAL REINFORCING OR SMALLER. 2,- TIE SPACING-: SHALL BE: A - LEAST DIMENSION OF COLUMN B - 16 TIMES MAIN BAR DIAMETER C - #3 AT la" OR 114 AT 24" WHICHEVER 15 SMALLER T`'f=ICAL CONCRETE COLUMN &FLICE DETAIL N_T.S FOOTING 5CHEDULE MARK SIZE W x L x D REINFORCEMENT REMARKS LONG. TRANS. WF -16 16"xCONT.xl2" 2 #5 - "B" BARS WF -24 24"xCONT.x12" 3 #5 04 02411 No. 4 SPACING EACH END O all x 21 11 /_ #j? 03D/agn 2 #5 CF -20 2'-0" x 2'-0" x 12" 3 #5 3 #5 # 3 CE -30 3'-0" x 3'-0" x 1211 4 #5 4 ' o all CF -36 3'4011 x 3'-6" x 16" 4 115 4 #B 2 #5 NOTE : 1. CONTRACTOR TO PROVIDE #5 CORNER BARS LAPPED MIN, 30" EACH WAY, FDR EACH BAR IN FOOTING, COLUMN 5CHEDULE MARK SIZE REINI=ORCEMENT REMARKS VERTICALS OR BASE fE TIES OR CAP fE 0 all x 12" 4 #a #3f]�a° "B" BARS 0 1'2" x 1211 4 #6 113N) ")a11 No. 4 SPACING EACH END O all x 21 11 /_ #j? 03D/agn 2 #5 ® HSS 3 I/2"x3 1/211x5/16" SEE DETAIL 5EE DETAIL # 3 ® all x 27" 6 15 22'-311 o all ® all x 13" 4 #5 #3n] tea" 2 #5 # 3 4,a12" BAL a4a'' RTB-1 NOTE : Q DENOTES COLUMN START oX DENOTES COLUMN END a° ° 448 #2 HAIRPIN a"O/C ,TC -1 COL. DETS. COL.o DET. CCL..® �. L d #3 HAIRPIN DET, CCL..® DFT. SEAM 5CHEDULE MARK TOP ELEV. SIZE (INCHES) BOTTOM. REINF. TOP REINFORCING STIRRUPS REMARKS D "A" BARS "B" BARS "G" BARS "T" BARS "E" BARS SIZE No. 4 SPACING EACH END T15-1 VARIES all 12" 2 #5 � N � cJ w Q 2 #D # 3 4'312" BAL a4all TB=2 22'-311 o all 4a" 2 #5 2 #5 # 3 4,a12" BAL a4a'' RTB-1 VARIES a" 12" 2 05 2 #5 # 3 4,a1211 BAL �5)4a" RAKED BEAM R5-1 22'-3" all 32" 2 #6 2 #6 # 3 113 s✓" O/C, 5-1 12'-011 all 3611 2 01 2 #7 # 3 #3 1310" O/C, 5-2 9'=011 all 24" 2 06 2 #6 # 3 #3 810" O/C, 5-3 II' -I" all 30" 2 06 2 06 # 3 #3 010" O/C, 5-4 111-1" all 24" 2 #1 2 #1 # 3 #3 1�03" O/C, PROVIDE 3+1-1 EF INTERMIDIATE BARS EQ SPA 5-5 10'-911 all 26" 2 06 2 #6 # 3 #3 '310" O/C. C_-�REATER OF 0.5 LI OR 0.3 L2 EME3ED 12 5AR DIAM. 11T'' BA S NOTE I. "L'' IS TI --IE LONGER OF 4DJ,4CENT SRAN. 2, 0" UJIDE 5EA1�15 TAKE A MAXIMUM OF 2 5ARS PER LAYEIR, 3, STIRRUPS TO 5E CLOSo'TY17'E WITH 135° NOOK. 4. MID BARS TO 5E #5 X12" E.F. WkENEVEfi- BEAM DEPTH IS LARGER THAN 2'=0" 5, CONTRACTOR TO PROVIDE 25 CORNER 5AiR5 LAPPED MIN. 30" EACH UJA�I', 11 11 rD A C)C, I I /,� LASS 11A11 LAS' SPLICE — "T" F3AR5 RUN CONTINUOUS OR LAP AS REQ'D. AT MIP SPAN. 1 0.3 L 1 E BARS STD. HIOOKS (c, TOP AND BOTTOM REINFORCEMENT SHALL 5E CONTINUOUS FOR ALL TIE SEAMS -1. AS PER ACI 318=02, SECTION 1.13.2.2 IN EXTERIOR PERIMETER SEAMS PROVIDE ADDITIONAL BOTTOM REINFORCEMENT OVER THE SUPPORTS EQUAL TO AT LEAST 25% OF THE LARGER TOTAL 50TTOM REINFORCEMENT AREA CALLED OUT FOR THE MIP -SPAN OF ADJACENT 5E41-15, AND IN ADDITION, AT LEAST 20% OF THE TOP REINFORCEMENT, 5UT NO LESS THAN TWO E3,4IRS, 5HALL PE CONTINUOUS OVER ALL SUPPORTS. TH15 ADDITIONAL REINFORCEMENT 15 TO f5E SPLICED WITH A TENSION "GLASS A" SPLICE 15EGINNING AT THE FACE OF THE 5UPPORT, t�PICAL SEAM 5,4R FLACING D IAGFAM, N.T.S. "C" BARS POR 12" OR WIDER BEAMS• TOP BARS LX "C" BARS (FOR all BMS.) 'MID" BARS (SEE NOTE 4) V N X LLI '— U— MID" BARS (SEE NOTE 4) C, X Lu..i BOTTOM BARS NOTE : QUANTITY OF 'MID" BARS VARIES W/ 5EAM5 DEPTH, SEE BEAMS SEE NOTE -4 ON BAR PLACING DIAGRAM T*rf=IC;AL SAR RLACEMENT DETAIL N.TA �;1:('Y OF S(JU•TH MIAMI BUILDING DEPT- F3U1L0it4G SEr 1011 ,,?PROVE()13Y--'9----- ,)IT-L, 3Y---'9— .---,ITS.. X11 P MrI CONSULTING STR,IJGT,U,�2gJ�Fi�R1N�Z'��a 716&SWV'ST. SUITE B=4:°NIIAMI,FL°_ 66 9 18 eL 3 A(19135�p Jr �X q 5]) 75OF ���pppppp o • n UI!� PAUL A.'M2�TINEZ I � %%% FLORIDA REGd No. X42650 PMMCE JOB # 11019 FC.14 ,SEAL REVLSIONS ' : L- a- 3.- 4.- 5.- 6.- DATE : FEBRUARY, 2012 SCALE: AS NOTED DRAWN: Y. SOSA DESIGN BY' PAM JOB NO: as m i' i <DDo o w V D O 0 o 00 z L q s � N � cJ w Q ,SEAL REVLSIONS ' : L- a- 3.- 4.- 5.- 6.- DATE : FEBRUARY, 2012 SCALE: AS NOTED DRAWN: Y. SOSA DESIGN BY' PAM JOB NO: