12-224-011FLAME SPREAD AND SMOKE DENSITY:
8315.1 WALL AND CEILING FINISHES SHALL BE HAVE FLAME SPREAD
CLASSIFICATION OF NOT GREATER THAN 200,
EXCEPTION: FLAME-5PREA0 REQUIREMENTS FOR FINISHES SHALL NOT APPLY TO
TRIM DEFINED AS PICTURE MOLDS, CHAIR RAILS, 5A5E5OARD5 AND
HANORAILSi TO DOORS AND WINDOWS OR THEIR FRAMESt OR TO MATERIALS
THAT ARE LESS THAN iia INCH IN THICKNESS CEMENTED TO THE SURFACE OF
WALLS OR CEILINGS IF THESE MATERIALS HAVE A FLAME-5PREAD
CHARACTERISTIC NO GREATER THAN PAPER OF THIS THICKNESS CEMENTED TOA
NONCOMBUSTIBLE BACKING.
R3152 SMOKE -DEVELOPED INDEX
WALL AND CEILING FINISHES SHALL HAVE A SMOKE -DEVELOPED INDEX OF NOT
GREATER THAN 450.
83153 TESTING
TEST SHALL BE MADE IN ACCORDANCE WITH ASTM E 84.
8315.4 ALTERNATE TEST METHOD.
AS AN ALTERNATE TO HAVING A FLAME -SPREAD CLA5IFICATION OF NOT
GREATER THAN 200 AND A SMOKE DEVELOPED INDEX OF NOT GREATER THAN
450 WHEN TESTED IN ACCORDANCE WITH ASTM E 84, WALL AND CEILING FINISHES,
OTHER THAN TEXTILES, SHALL BE PERMITTED TO BE TESTED IN ACCORDANCE
WITH NFPA 286MATERIALS TESTED IN ACCORDANCE WITH NFPA 286 SHALL MEET
THE FOLLOWING CRITERIA:
DURING THE 40KW EXPOSURE, THE INTERIOR FIN15H SHALL COMPLY WITH ITEM M.
DURING THE 160 KW EXPOSURE, THE INTERIOR FIN15H SHALL COMPLY WITH ITEM
*2. DURING THE ENTIRE TEST, THE INTERIOR FINISH SHALL COMPLY WITH ITEM 3.
I. -DURING THE 40 KW EXPOSURE, FLAMES SHALL NOT SPREAD TO THE CEILING.
2: DURING THE 160 KW EXPOSURE, THE INTERIOR FIN15H SHALL COMPLY WITH THE
FOLLOWING:
2.1. FLAME SHALL NOT SPREAD TO THE OUTER EXTREMITY OF THE SAMPLE ON
ANY WALL OR CEILING.
22. FLASHOVER, AS DEFINED IN NFPA 286, SHALL NOT OCCUR
3.- THE TOTAL SMOKE RELEASED THROUGHOUT THE NFPA 286 TEST SHALL NOT
EXCEED 1,000 m
8316.1 INSULATION
INSULATION MATERIALS, INCLUDING FACINGS, SUCH AS VAPOR RETARDERS OR
VAPOR PERMEABLE MEMBRANES INSTALLED WITHIN FLOOR -CEILING
ASSEMBLIES, ROOF -CEILING ASSEMBLIES, WALL ASSEMBLIES, CRAWL SPACES
AND ATTICS SHALL HAVE A FLAME-5PREAD INDEX NOT TO EXCEED 25 WITH AN
ACCOMPANYING 5MOKE-DEVELOPED INDEX NOT TO EXCEED 450 WHEN TESTED
IN ACCORDANCE WITH ASTM E 84.
EXCEPTIONS:
I. WHEN SUCH MATERIALS ARE INSTALLED IN CONCEALED SPACES, THE
FLAME -SPREAD AND SMOKE -DEVELOPED LIMITATIONS DO NOT APPLY TO THE
FACINGS, PROVIDED THAT THE FACING 15 INSTALLED IN SUBSTANTIAL CONTACT
WITH THE UNEXP05ED SURFACE OF THE CEILING, FLOOR OR WALL FINISH.
2. CELLULOSE LOOSE -FILL INSULATION, WHICH 15 NOT SPRAY APPLIED,
COMPLYING WITH THE REQUIREMENTS OF SECTION 83163, SHALL ONLY BE
REQUIRED TO MEET THE SMOKE -DEVELOPED INDEX OF NOT MORE THAN 450.
12
5 �-
HURRICAN STRAP
3X3 (26 GA) GALV M
DRIP NAILS 15D 4' O.C.
TOP OF BEAM
1X2 PT NAILE .
WD. FASCIA W/C2�lrod
,>
NAILS a EA. TRUSS
WD. SOFFIT W/4" W.
SCREENED VENTS
CONTINUOS.
I
NEW 5/8' STUCCO FINISH
ON EXISTING 8' CONC.
BLOCK W/"9 HORZ. RE INF
10 EVERY 2ND. COARSE 4
EXTN 4' INTO COL'S.
(LADDER TYPE).
I
1 #E, TIE DOWN (TYP)
lw 4'-0' MAX. O.G.
11 c�
N
0
TOP OF FINISH. FLOOR I)
e
FINISH GRADE co,
11
UA •-fie !�
TYPICAL END WA
@GARAGE AREA
LL SECTION
3/4"= 1'-0"
ROOF PLYWOOD SHEATHING NOTE:
5/8' CDX EXTERIOR PLYWOOD, NAILED WITH ad NAILS m 6'
ON CENTER AT SUPPORTS, 10d NAILS 6 4" O.C. AT GABLE
ENDS AND EDGES. TYP.
TIE BEAM NOTE:
F.B.C. THE TIE BEAM SHALL BE CONTINUOUS. CONTINUITY
OF THE REINFORCING IN STRAIGHT RUNS SHALL BE PROVIDED BY LAPPING
SPLICES NOT LESS THAN 18 INCHES. CONTINUITY SHALL BE PROVIDED AT
CORNERS BY BENDING TWO BARS FROM EACH DIRECTION AROUND THE CORNER
30 INCHES OR BY ADDING TWO 05 BENT BARS WHICH EXTEND 30 INCHES (2 " 5 X 5'-O')
EACH WAY FROM THE CORNER CONTINUITY AT COLUMNS SHALL BE PROVIDED
BY CONTINUING HORIZONTAL REINFORCING THROUGH COLUMNS OR BY BENDING
HORIZONTAL REINFORCING IN THE COLUMNS A D15TANCE OF 30 INCHES.
SPANISH TILE ROOF ATTACH W/ ROOF GEMENT ON
90* HOT MOPPED SLATE OVER 30* TIN TAG 4 3/4'
RING SHANKED NAIL FELT UNDERLAYMENT IN GRID
PATTERN 'm 9' O.C. 4 6' O.C. ON OVERLAP OVER 5/8'
PLYWOOD SHEATHING
5/8' CDX EXTERIOR PLYWOOD, NAILED
WITH ad NAILS 10 6' ON CENTER AT
SUPPORTS, 10d NAILS w 4O.C. AT
GABLE ENDS AND EDGES. TYP.
3' x 3' 26 GA .GALV. METAL DRIP
LAPPED 6' AND NAILED
6 4"G.C. OVER 1'X2' P.T.
WD. NAILER CONT.
Ai--\ OF BEAM
EL. +20'-1'
SPANISH TILE ROOF ATTACH W/ ROOF
CEMENT ON 90" HOT MOPPED SLATE
OVER 30* TIN TAG 4 3/4" RING SHANKED
NAIL FELT UNDERLAYMENT IN GRID
PATTERN im 9' O.C. 4 6' O.G. ON OVERLAP
OVER 5/a' PLYWOOD SHEATHING
PRE -FAB. WOOD TRUSSES BY OTHER
R-30 INSULATION
1'X3' FURRING m 16' O.C. W/ 5/8' TYPE X
GYPSUM BOARD SEE SPECF. ON SHEET
A-3
1'X3' PT FIRE STOP PRESSURE TREATED
8'X12' GONG. TIE BEAM W/4 *5'5 CONT. 4 2
" 5 BENT 30' EA. WAY At COMERS.
PROVIDE 4 *3 TIES m 12" O.C_ AT CORNERS
4 AT 48' THEREAFTER
1/2' DRYWALL OVER 1'X2" Pt. WD FURR
16' O.C.
1'X3' PT FIRE STOP PRESSURE TREATED
INSULATION R.4.1
4' WOOD BASE
1/2' EXPANSION JOINT
4" CONC. SLAB REINF. W/
6"X6" #10/10 W.W.M.
PROVIDE 6 MIL VAPOR BARRIER
ON GROUND SLAB
WELL COMPACTED TO
95% MAX. DENSITY
CONCRETE FOOTING SEE S-1
FOR SPECIFICATIONS
2'X8' WD. FASCIA
MRKD
LIGHT TEXTURE STUCCO
WTH,
ON METAL LATH ON
TYPE
MATERIAL
5/8' CDX PLYWOOD
N.O.A.
i__j
WD. SOFFIT W/4' W.
1
SCREENED VENTS (TYP.)
I
CONTINUOS.
DOUBLE
METAL
LIGHT TEXTURED STUCCO
08-101505
4Y
ON 8" GONG. BLOCKS
II
d,\ TOP OF 2nd FLOOR T.B.
EL. + 11'-1'
TIE BEAM. REFER
STRUCT. DWG'S
LIGHT TEXTURED STUCCO
ON 8' GONG. BLOCKS
PROVIDE HORIZONTAL JOINT
REINFORCEMENT 6 16 "O.C.
EVERY OTHER BLOCK COURSE
*9 LADDER TYPE TYP
PROVIDE 3/4' RECESS AT BLOCK
WALL 4 SLIDING GLASS DOOR
(TYPICAL)
GROUND FL. FIN.
EL. +O'-0"
12
5 GN
c ¢oOp�r""
rri
15RE-FAB WOOD TRUSSES AS
PER MANUFACTURES SPECS.
BATT INS LATION (R=30)
FULL LENNGTH LAYER OF 1/2'
DRYWALL ON 1'X3' WOOFURRING
STRIP 16' O.G. WITH R-19 INSULATION.
IN X 4' P.T. WD. FIRE STOP
HURRICANE STRAP
8'X12' GONG. TIE BEAM
W/405 BARS CONT. (TYP.)
03 TIES a 12' m CORNERS,
54L.6 48' C.C.
WOOD FURRINGxS AT 24' O.C.
INSULATION (R4.1)
1'X4' P.T. WOOD
BASE BOARD
FLOOR SHEATING SHALL BE
3/4' PLYWOOD NAILED TO
TRUSSES WITH 10d NAILS SPACE
Q 6' O.G. AT PANEL EDGES
AND -9 10" O.C. ON
INTERMEDIATES SUPPORTS.
I Z- 16' FLAT FLOOSii WOOD TRUSSES SEE
STRUCTURAL DRAWINGS
" GYPSUM BOARD ON IN X 3'
WOOD FURRING AT 16' O.C.
1' X 4' P.T. WOOD FIRE STOP
INSULATION (R4.1)
1/2' GYPSUM BOARD ON I'X2'
WOOD FURRINGS AT 24' O.C.
" 5 DOWEL 6 48' C.0
I'X4' P.T. WOOD
NAILER CONT. (TYP)
4' WOOD BASE BOARD
.: • . '�` I'� 4' CONG. SLAB
5EE FOUNDATION PLAN
....,::
MOISTURE BARRIER
TYPICAL END WALL SECTIONA
3/4"= 1'-0"
NOTES
ALL NON IMPACT RESISTANT WINDOW 4 EXTERIOR DOORS REQUIRED SHUTTERS BY SEPARATE PERMIT
DOOR SCHEDULE O
•
MRKD
SIZE
WTH,
HEIGHT.
TYPE
MATERIAL
FRAME
N.O.A.
REMARKS
1
2(2'-8')
1-3/4'
8'-0'
DOUBLE
METAL
METAL
08-101505
—
2
5311/6'
505/6'
ALUM/GLASS
YES
DOUBLE
08_1
0.66
3
16'-0"
-i'-O"
GARAGE
MTL
MTL
0-1-0'106.05
ROOLING GARAGE DOOR
4
2'-6'
505/8'
8'-0'
FLUSH
AL/GL_
ALUM.
08-041-1.05
IMPACT GLASS
5
2(4'-0')
a'-0'
SLIDING
AL/GL.
ALUM.
01-0301.09
IMPACT GLASS
6
2(3'-0')
HR 24
8'-O'
FRENCH
AL/GL.
ALUM.
08-041-1.05
IMPACT GLASS
7
2(2'-6")
1-3/8'
V -O'
BI -FOLD
WOOD
WOOD
FULL. LOUVER DOOR FOR FRESH AIR
8
3'-0'
1-3/8'
S'-0"
FLUSH
METAL
METAL
I HR FIRE RATED DOOR
9
2'-0'
1-1/8'
8'-0'
BI -FOLD
WOOD
WOOD
10
2'-0'
I-1/8'
8'-0'
BI -FOLD
WOOD
WOOD
FULL LOUVER DOOR A/C CLOSET DOOR
11
2'-8'
1-3/8'
8'-0"
FLUSH
WOOD
WOOD
12
2(2'-8')
8'-0'
FRENCH
AL/GL.
ALUM.
08-0411.05
IMPACT GLASS
13
2'-8"
1-1/8'
8'-O'
FLUSH
WOOD
WOOD
FULL LOUVER DOOR A/C CLOSET DOOR
14
2'-6"
S' -O'
FLUSH
WOOD
WOOD
15
3'-0'
1-1/8'
8'-O"
BI -FOLD
WOOD
WOOD
40
2'-8'
1-1/8'
8'-O'
FLUSH
WOOD
WOOD
11
2'-6"
I-1/8"
8'-O"
BI -FOLD
WOOD
WOOD
BI -FOLD
WOOD
WOOD
19
2'-8"
1-3/8'
8'-O"
FLUSH
WOOD
WOOD
20
2(3'-0')
1-1/8'
8'-0'
BI -FOLD
WOOD
WOOD
21
2(2'-8')
1-3/8"
8'-0'
DOUBLE
WOOD
WOOD
22
2'-6"
1-1/8"
8'-0"
BI -FOLD
WOOD
WOOD
23
2'-6"
1-1/8'
S'-0"
BI -FOLD
WOOD
WOOD
1-3/8'
S' -O'
FLUSH
WOOD
WOOD
NOTES
CONTRACTOR SHALL VERIFY ALL FINISHES W/OWNER PRIOR TO PURCHASING MATERIALS
CONTRACTOR SHALL VERIFY ALL COLORS W/ OWNER PRIOR TO COMMENCEMENT OF WORK
UJINDOW SCHEDULE
*
MRKD
WIDTH
HEIGHT
MATERIAL
IMPACT
GLASS
U -COEFFICIENT
SHGC
p
(0o
�
RESISTANT
TYPE
N Uao
HR 34
5311/6'
505/6'
ALUM/GLASS
YES
DOUBLE
08_1
0.66
CLEAR
HR 44
-I4'
505/8'
YES
DOUBLE
Obi
0.66
CLEAR
HR 24
3�'
505/8'
YES
DOUBLE
0.8-1/
0.66
CLEAR
HR 43
-14"
383/8'
YES
DOUBLE
0.81
0.66
CLEAR
NOTES
ALL WINDOWS WITH PRODUCT APPROVAL AND SEPARATE PERMIT
(TYP) PROVIDE STORM SHUTTER BEFORE FINAL INSP. (BY OTHER)
2'-0'
(O.C.)
)OF TRUSSES
:RS)
SSS INSULATION (TYP.)
TYP. WALL SECTION
'WOOD SHEATHING
3PRAY FIN. ON 1/2'
CEILING (TYP.)
'IVE TRIM MOULDING
=OUR SIDES)
_... ::)F 1/2" DRYWALL
ADHERED TO PLYWOOD SHEATHING
W/ LAMINATING COMPOUND COMBED
OVER ENTIRE CONTACT SURFACE
ACCESS ATTIC DETAIL
3/41w= 1'-0"
v-
ni
O
CD
2'-0 3/16'
( INSIDE LOOKING OUT)
$ soul
T
-TION
A.eX1P !
-Isla µi
AREA OF CLEAR OPENING
8 SQ. FT.
EG3RE55 WINDOW NOTE&
IN AN OUTSIDE WINDOW OPERABLE FROM
THE INSIDE, THE MODE OF OPERATION
SHALL NOT REQUIRE THE USE OF A KEY,
TOOL, SPECIAL KNOWLEDGE OR EFFORT,
SUCH CLEAR, OPENING SHALL NE NOT LESS
THAN 20' IN WIDTH, AND 24" IN HEIGHT, AND
5.7 SQ. FT. IN AREA. THE BOTTOM OF THE
OPENING SHAL-L BE NO MORE THAN 44"
ABOVE THE FINISHED FLOOR AND NO
PARI OF THE OPERATING MECHANISM
SHALL BE PLACED HIGHER THAN 34'
ABOVE THE FINISHED FLOOR. AS PER
SECTION 10252, 1025.2.1, 1025.3 -F.5.0-2001
OL TOP OF FIN. FLOORCII d DEPT.
ELEV. 0'-UIL0
BUILDING EZ%' Oto
EGRESS WINDOW DETAIL7I`��`
3/4"= 1'-0"
LOT 17
't"
No Q M
U6 J
W LIN.
z
W a
o-
n
WMINOR
�..
J Q
� a
ul z
Lu NONE!
a
J
z
z p
W
z
M
sem.
REMONS
1-
2-
a-
4,-
S.-
6 -
DAN :FF:6F2UARY, 2012
SCALB: S�IowN
O AWR. M. CASTELLON
DESK$/ BY JR
JOB 110
A-7
O
CD
00 00
N
`
p
(0o
�
u
N Uao
�a
z
qF..
}
..
't"
No Q M
U6 J
W LIN.
z
W a
o-
n
WMINOR
�..
J Q
� a
ul z
Lu NONE!
a
J
z
z p
W
z
M
sem.
REMONS
1-
2-
a-
4,-
S.-
6 -
DAN :FF:6F2UARY, 2012
SCALB: S�IowN
O AWR. M. CASTELLON
DESK$/ BY JR
JOB 110
A-7