05-1438-011DATA = CAT 5
A VOICE = CAT 5
DOOR BELL
CABLE
ANTISCALD NOTE:
ALL SHOWER NEAP MIXING VALVES SHALL SE SCALD
PREVENTIVE OF THE PRESSURE OALANCE TYPE.
N
N
N
IL
I`
N
�t
N
O
O
N
00
O
O
i
Z
Q
N
Z
Q
F�:
N
N
LO
Q
N
Q
co
t`
r-
Www"d
aOFFICES FOR HANZMAN —I— CRIDEN, P.A.
o OFFICE CONDO BUILDOUT
� SUITE 515, FIFTH FLOOR, PLAZA 57
W 7301 S.W. 57TH COURT
o' CITY OF SOUTH MIAMI
a SOUTH MIAMI, FLORIDA 33143
a
PLUMBING NOTES
1.0 GENERA.
1.1 PROVIDE ( FURNISH AND INSTALL ) ALL NECESSARY
MATERIALS AND LABOR FOR A COMPLETELY OPERATIONAL
PLUMBING SYSTEM AS SHOWN ON THE DRAWINGS AND
HEREIN SPECIFIED. INSTALL IN ACCORDANCE WITH THE
FLORIDA BUILDING CODE AND LOCAL ORDINANCES.
1.2 SCOPE OF WORK :
PROVIDE THE FOLLOWING COMPLETE SYSTEMS
A. SANITARY COLLECTION.
B. HOT AND COLD WATER SUPPLY.
C. AIR CONDITIONING CONDENSATE.
D. ROOF DRAINAGE.
1.3 PAY FOIR ALL FEES, INSPECTIONS AND CONNECTION
CHARGES REQUIRED.
1.4 VERIFY .AT JOB SITE ALL SPACE CONDITIONS, DIMENSIONS
WITH PIPE, FIXTURES, AND EQUIPMENT SIZES PRIOR TO
FABRICATION OR INSTALLATION. COORDINATE REQUIREMENTS
TO AVOIID INTERFERENCE WITH OTHER TRADES.
1.5 SUBMIT SHOP DRAWINGS FOR ARCHITECT / ENGINEER
APPROVAL BEFORE PROCEEDING WITH THE PURCHASE OR
INSTALLATION OF EQUIPMENT AND MATERIALS.
1.6 GUARANTEE ALL WORK FREE OF DEFECTS IN MATERIALS
AND WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM
DATE OFF ACCEPTANCE.
2.0 MATERIALS
2.1 PROVIDE SHUT-OFF VALVES FOR EACH FIXTURE AND
WATER HAMMEL ARRESTOR WHERE SHOWN AND WHERE
REQUIRED FOR PROPER PERFORMANCE OF THE SYSTEM.
2.2 PROVIDE DIELECTRIC FITTINGS TO CONNECT PIPING TO
EQUIPMENT OF DISSIMILAR METALS. USE CLAMPS AND
FASTENERS OF SIMILAR METALS OR ISOLATE THEM FROM
PIPING ,AND SLABS TO PREVENT CORROSION.
2.3 PIPING
2.3.1 DOMESTIIC HOT AND COLD WATER: COPPER TUBING TYPE
"K" OR "L" WITH SOLDER JOINTS. WOG BRONZE VALVES
125 P.S.I. MIN. PROVIDE PRE -MOLDED FIBERGLASS
INSULATION FOR HOT WATER LINES.
2.3.2 SANITARY WASTE, VENT, AND ROOF DRAINAGE CAST IRON PIPING
NO —HUB;
2.3.3 A/C CONDENSATE:
ABOVE FLOOR: COPPER D.W.V. PIPE WITH ARMFLEX INSULATION.
BELOW FLOOR: PVC SCHEDULE 40 AND FITTINGS.
INSULATE ALL OVERHEAD HORIZONTAL RUNS WITH 1/2" ARMFLEX
INSULATION.
PLUMBING FIXTURE SCHEDULE
SYMBOL
FIXTURE TYPE
STIRZE
C.W.
H.W.
DESCRIPTION
KS
KITCHEN 61M<
12'
1/2'
REF.
REF. ICE MAKER
-
12'
-
ANTON«D FRANYIE
VIVIA J4 rR,. NYIE
FIE 1499:35 kic
Certificate of
Authorization #
0000 oa
iQC NW 27 Street, Miami FL 33172
TEL: (306 5 21FAX: (305) 594-9279
wwv►C. n -f n ineers.com
DESKS d Y DATE
JOB NUMBER
O
EcID
Ee
PARTNER'$
OFFICE I
PARTNER'5
OFFICE 2
O
WORK
STATION 1
ADMIN
OFFICE
PARTNERS
OFFICE 3
EXISTING
o' ROOF DRAM
I PANTRY/
STATION 2 STATION 3 3TCR46E
1 �
...a. PARA fit,
I OFFICE —
__ 1{
OFFICEE4 S (r mm �I f_..I__
HALLWAY
SMALL
O X�
CONFERENCE ROOM
EXI8TING -~
2' A/C DRAIN DN.
CONFERENCE T2I"1 RECEPTION (TYPICALI IV A
AREA PXIS1
3/V FOR GROUND
1 314C.W.
3'VENT.
VSD (DN) 4'66
(480-)
PLUMBING OFFICE PLAN - 5UITE-
$CALE: 10 • P-0'
FIFTH LEVEL
BUILDING PLAN,
�1/21 cW
--
--------Co.
�I
I)
STAIR NO.1
I I
I
I�
CONNECT NEW Ii2'
CW PIPE TO EXISTT.
REMOVE CAP AND
CONNECT NEW 2' SAN.
'
PIPE 4 2' VENT TO
v
EXISTMG
Z
515
d DRAWING TTiLE:
CHANDLER AND ASSOCIATES NO
DATE FINIS NO DATE REVISION
ARCHTnECTURK PA PLUMBING PARTAL
A' 0003050 OFFICE PLAN
MSON R CHANDLER. A.TA AR. NOQ 16068 ( I
BUTTE 515
e
y. �'... yle�.,, PALE:
SOUTH NHAW FLORIDA 33143 ; ; �r,t �''�T •., TE:
TEL M 669-759Z I �� I
AN ECT NOS 20051
FAX (� •669-7593 i :' E;� �'� #?RAWY�K2 NO:
2 ' •
ocraMw Boa F E ..� � .. e 4°vt� .• k
,3 I,y k, I
r