05-1438-010HVAC NOTES 1.0 1.1 PROVIDE (FURNISH AND INSTALL) ALL NECESSARY MATERIALS AND LABOR FOR A COMPLETELY OPERATIONAL HEATING, VENTILATING AND AIR CONDITIONING (HVAC) SYSTEM AS DEPICTED ON THESE CONTRACT DOCUMENTS. 1.2 INSTALL IN ACCORDANCE WITH THE FLORIDA BUILDING CODE, ASHRAE SMACNA, NFPA AND LOCAL ORDINANCES. 1.3 SCOPE OF WORK : PROVIDE THE FOLLOWING COMPLETE SYSTEMS A. AIR CONDITIONING SUPPLY AND RETURN DUCT SYSTEM. B. EXHAUST SYSTEM FOR TOILET ROOMS. C. EXHAUST SYSTEMS FOR WAREHOUSE. D. AIR CONDITIONING UNITS AND CONTROLS. E. INDEPENDENT TEST AND BALANCE. 1.4 NOT USED 1.5 PAY FOR ALL FEES, INSPECTIONS AND CONNECTION CHARGES REQUIRED 1.6 VERIFY AT JOB SITE ALL SPACE CONDITIONS AVAILABLE FOR THE INSTALLATION OF MATERIALS AND EQUIPMENT PRIOR THE INSTALLATION OF EQUIPMENT AND FABRICATION OF DUCTS AND PIPING SYSTEMS. COORDINATE SPACE REQUIREMENTS FOR SERVICE AND MAINTENANCE AND COORDINATE INTERFERENCE WITH OTHER TRADES. 1.7 NATURE OF DESIGN DRAWINGS; DESIGN DRAWINGS ARE DIAGRAMMATIC AND DO NOT INTEND TO SHOW EVERY FITTING, ELBOW, TRANSITION, ETC. THAT WILL BE NECESSARY FOR A COMPLETE AND OPERATIONAL SYSTEMS REQUIRED BY THESE SPECIFICATIONS. 1.8 COORDINATION DRAWINGS; PREPARE 1/4" SCALE (MIN.) COORDINATION DRAWINGS SHOWING DUCTWORK, PIPING AND ALL MAJOR SYSTEM COMPONENTS FOR A/E APPROVAL BEFORE PROCEEDING WITH THE INSTALLATION. IMPLEMENT ALL INFORMATION FROM 1.6 ABOVE. 1.9 SUBMIT SHOP DRAWINGS FOR A/E APPROVAL BEFORE PROCEEDING WITH THE THE PURCHASE OR INSTALLATION OF EQUIPMENT AND MATERIALS. ALL SHOP DRAWINGS MUST BE SUBMITTED IN A SINGLE BOUND AND INDEXED PACKAGE NO LATER THAN 30 DAYS FROM THE ADJUDICATION OF THE PROJECT. 1.10 GUARANTEE ALL WORK FREE OF DEFECTS IN MATERIALS AND WORKMANSHIP FOR A A PERIOD OF ONE YEAR FROM THE DATE OF PROJECT ACCEPTANCE. 2.0 AAAT'FRIAI t 2.1 DUCTWORK 2.1.1 GENERAL. ALL DUCT SIZES SHOWN ARE CLEAR INSIDE DIMENSIONS. 2.1.2 DUCTWORK MATERIALS: A: GENERAL OFFICE AREAS: FIVE POUNDS DENSITY 1.5" THICK GLASS FIBER (R-6) DESIGNED, CONSTRUCTED AND INSTALLED IN ACCORDANCE WITH SMACNA'S FIBROUS GLASS DUCT CONSTRUCTION STANDARDS. DUCT JOINTS SHALL BE SEALED AND TAPED. B: TOILET ROOM EXHAUST AND FRESH AIR INTAKES: GALVANIZED SHEET METAL, CONSTRUCTED, AND INSTALLED ACCORDING TO LATEST EDITION OF SMACNA'S. LOW PRESSURE CONSTRUCTION STD. (0.5" W.G.) C: EXPOSED AIR CONDITIONING DUCTWORK SPIRAL GALVANIZED SHEET METAL, CONSTRUCTED, AND INSTALLED ACCORDING TO LATEST EDITION OF SMACNA'S. LOW PRESSURE CONSTRUCTION STD. (0.5" W.G.) 2.1.3 PROVIDE DOUBLE THICKNESS TURNING VANES AT ALL SQUARE ELBOWS. WHERE THE ELBOWS ARE RECTANGULAR INSTALL SINGLE THICKNESS VANES. .1 ALTERNATE A: PROVIDE 3-PIECE ELBOWS IN LIEU OF TURNING VANES FOR GLASS FIBER DUCTS ONLY. .2 ALTERNATE A: PROVIDE FULL RADIOS ELBOWS IN LIEU OF TURNING VANES. 2.1.4 PROVIDE VOLUME EXTRACTORS BEHIND EACH SUPPLY OUTLET AND AT EACH DUCT BRANCH. 2.2 NOT USED. 2.3 NOT USED. 0) N N M N LO O O N 3 -0 N O Q N Q LO LO r- Z Q N Z Q 2 co ti O CN SUITE 515, FIFTH FLOOR, PLAZA 57 w 7301 S.W. 57TH COURT o CITY OF SOUTH MIAMI a SOUTH MIAMI, FLORIDA 33143 2.4 AIR DISTRIBUTION PRODUCTS : 2.4.1 PROVIDE EXTRUDED ALL ALUMINUM AIR DISTRIBUTION PRODUCTS. 2.4.2 PROVIDE SUPPLY AND RETURN GRILLES AND DIFFUSERS AS INDICATED ON THE DRAWINGS AND SCHEDULES. 2.4.3 PROVIDE FINISHES AND TYPES OF MOUNT IN COORDINATION WITH THE CEILING TYPES AS SHOWN ON ARCHITECTURAL DRAWINGS. 2.4.4 PROVIDE OPPOSED BLADE, KEY OPERATED DAMPERS BEHIND ALL AIR SUPPLY OUTLETS. 2.5 PROVIDE A MINIMUM 5 YEAR WARRANTY FOR ALL AIR CONDITIONING COMPRESSORS STARTING FROM THE DATE OF PROJECT ACCEPTANCE. 2.6 CONTROLS: 2.6.1 GENERAL: PROVIDE THE NECESSARY AUTOMATIC CONTROLS FOR PROPER OPERATION OF ALL EQUIPMENT SPECIFIED HEREIN. FURNISH MAGNETIC STARTERS AND INTERLOCK WIRING INDICATED FOR EACH PIECE OF EQUIPMENT. 2.6.2 OFFICE AREA DX EQUIPMENT: PROVIDE AIR CONDITIONING UNITS WITH MATCHING LOW VOLTAGE HEAT/COOL THERMOSTATS WITH ON -OFF AUTO SUB -BASE SWITCH AS FURNISHED BY THE EQUIPMENT MANUFACTURER. 2.7 STARTERS: PROVIDE MAGNETIC STARTER FOR ALL MECHANICAL EQUIPMENT IN THIS SECTION AS DESCRIBED ON THE EQUIPMENT SCHEDULES. ALL STARTERS MUST HAVE HAND -OFF -AUTO POSITION SWITCH ON THE COVER AND RED/GREEN PILOT LIGHTS, PROVIDE THE NECESSARY AUXILIARY OPEN AND CLOSED CONTACTS FOR THE INTENDED OPERATION AND INTERLOCKS. 2.8 NOT USED. 2.9 IDENTIFICATION: 2.9.1 LABEL ALL EQUIPMENT WITH ENGRAVED BLACK PLASTIC PLAQUES 12"0" HIGH WITH WITH 1.5" LETTERS. USE THE SAME NOMENCLATURE AS IN THESE DOCUMENTS. 2.10 RETURN AIR CEILJNG PLENUMS: 2.10.1 WHEN CEILING SPACES ARE USED AS "RETURN AIR CEILING PLENUMS" ALL MATERIALS INSIDE THE R/A CEILING PLENUM SHALL HAVE A MAXIMUM FLAME SPREAD INDEX OF 26 AND A MAXIMUM SMOKE DEVELOPED INDEX OF 50 PER NFPA 90A. "NO PVC PIPING IS ALLOWED INSIDE THE R/A PLENUM." 2.10.2 PROVIDE FREE PATH FOR R/A INSIDE CEILING SPACE, SEE ARCHITECTURAL PLAN FOR COORDINATION 3.0 EXECUTION 3.1 INSTALL ALL EQUIPMENT AND MATERIALS IN STRICT ACCORDANCE WITH THE MANUFACTURER'S MANUALS AND RECOMMENDATIONS, PAYING SPECIAL ATTENTION TO REQUIRED CLEARANCES FOR INSTALLATION, OPERATION & SERVICE. FOR INSTALLATION, OPERATION AND SERVICE. 3.2 NOT USED 3.3 THERMOSTAT LOCATION. THERMOSTAT LOCATION IS CRITICAL TO PROPER EQUIPMENT OPERATION. INSTALL THERMOSTAT AT LOCATIONS SHOWN ON PLANS. RELOCATE ONLY WHEN APPROVED BY THE A/E IN WRITING. 3.4 RETURN AIR FOR INDIVIDUAL ROOMS IS BEING PROVIDED AS SHOWN ON PLANS AND IS SIZED COUNTING ON A 1" UNDERCUT FOR ALL DOORS IN ADDITION TO THE REQUIRED RETURN OR TRANSFER SYSTEM. 3.5 EQUIPMENT MUST OPERATE FREE OF OBJECTIONABLE NOISE AND VIBRATION REPAIR AND OR REPLACE ALL SOURCES OF NOISE AND VIBRATION FOUND TO BE OBJ CTIONABLE, TO THE SATISFACTION OF THE A/E. 3.6 BALANCE ALL SYSTEMS TO PROVIDE AIR AND WATER QUANTITIES AND CAPACITIES TO MATCH SPECIFIED FLOWS & CAPACITIES. CALIBRATE FLOWS TO NEW EQUIPMENT PER MANUFACTURER'S REQUIREMENTS. SUBMIT FINAL TEST AND BALANCE REPORT TO A/E FOR ACCEPTANCE. OUTSIDE AIR CALCULATIONS I (2) AHU 5 I I I_ ^^2,430 SF a 1�1 PEOPLi=- -.- 4- a 20 CFM/PERSON _ ._ __ _ � il 360 CFM O/A� OFFICES I O/A PROVIDED ! 400 CFM / O/AI I_ __ _ - _ _ _ _. _- _- - ____ _ ___ - __ __ _ _ q .m __ ._ _._ _.. __ _ _ .- __ _._ _ _ _ _ _ _ __ __ - -._ .-. --- _ _ _s .- __ _- J EXISTING SYSTEM PER SHELL DRAWM6 A/C SPLIT SYSTEM SCHEDULE -- DESIGNATION ------------------- L------�'---L---------- QUANTITY ____________________ _EXISTING(2)_ A_R_E_A_S_ERV_E_D_ ______________I ___51JIT� 515__ I ________ --_MA_N_U_FA_C_TU_R_ER-_-- - --------------- ___TRANE __----------- __ FA_N_C_OILMOD_E_L_N_o. _ _________�TILJEP 3 I_________. CONDENSING _UNIT _ MODEL No. LL________- _M__B_i _N_E__D__R_A_T_I__ TOTAL SENSIBLE CAPACITY B_TU/HR ___I __ 61000___L________- GRAND TOTAL CAPACITY__ BTUI/HR _____ I _ 45100 __ I _________ __ ERGTOTAL_HEATINGC_AP_ACITYBTULHR ____ __25,500 __- - - - - - - - - ENYEF_FICIE_NC_YRATIO SEER (EERI__ -- 12. 0___--____-_- __ COEFFICIENT OF PE_R_FOR_MANCE COP_____L_________L_________ F_A_ N__C 0 1 L U_N_ I_T______ ___ _ ________ --TYPE-----------------------L---_VERTICAL-L--------- TOTAL _AIR _SUP P_L_YCFM_ _I I 2�00 __ ________ OUTSIDE AIR _SUPPLY __C_F_M___ ______L__ 200 __L_________ EN_TERIN_G_ AI_R_C_O_NDIT_IO_N_S__F_D_B/FWB I -80/6� _ I __ EV_APO_R_AT_0_R_C_OII _MIN__RO_W_S_/_MA_X. F.P.I j ____ - I _________ EXTERNAL _STA_TI_C_PRESSURE "H20 r ___0.5___ I -_-_ FAN SPEED RPM ----------------j-_NICiN_5P_E_ED__- j -__-_--__--_-_-_- -- FA_N_M_0_T_ORHP_--_--_-_-_- _- -----3/4 ___4---------- __ ELECTRICAL __SERVICE AVAILABLE _0_ I __ 208/I/60_ RU_N_NIN_G_L_0_ADA_MP_S_______�___ 3_9 ___4-________ ELECTRIC RESISTANCE HEATER SIZEK_W___I -- UNIT WEIGHT-------------------�r-----225---L------- �'' C O N D ENS I N G_ U N_I_T _ __ __ _ ________ TY_PE------------------------�-- AIR COOLED-L--------- LOCATION ___ __________________I ___ ROO_P___ I ________ --RE_F_RI_GER_ANT_ TYPE ---------------L--- R-2�---L-------- AMBIENT AIR TEMPERATURE FDB �___ NUMBER _0_FCOM_PRSO_RS_ _____ ____ I ____ ________ NUMBER OFCU _REFRIGERANT CIRITS____ I ____--- _______ __CA_P_AC_IT_Y_ REDUCTION -STEPS %______I __ 0-10_0 __I --------- __ EL_ECT_RIC_ALSERVICE _AVAILABLE _________�__ 206/I/6ID4-________ RU_N_N_IN _G_L_0_AD__A_MP_S_______________1 ___ --24--- 4. 0___ 1 ________ MI_HIM_UM_CIR_C_UIT_A_M_PS__________________ 38.0___4-________ _MA_XIM_U_M_F_U_SE SIZE AM_PSI ___60._0___1 --UNIT WEIGHT-------------r-----212---L-------- AC_C__E_S__S_0__R_I_E__S_ _ _ _______ __ _ REFRIGERANT PIPING LENGHT FT________ __ti --------------- __ LIQ_UIDLINE TYPE O.D. -____ I SUCTION _LINE SIZE O.D._ - t TH__E_RM_0_S_TA_T_ HEAT/COOL I FILT_ER_ SECTION _AND _FILTER TYPE_______ llj!_THROWAIU_AY_L________ SMOKE DETECTOR ___I __IN 6UI90LY I ________ V_I_B_RAT_I_0_NISOLATORS _FA_N_C_OILUN_IT- _r-_--_-_-_-r-_--_-_-_-_-_- FO_R_CON_DEN_SIN_G_UNIT___ ___ L - - I AU_TOMATIC CONTROLS -- TYPE DESCRIPTION-------------------F---- _----j-------- ANTON10 FRANYIE VIV NA Fi?ANYtE Certificate of Authorization # 00002906 �06 NW 27 Street, Miami FL 33172 TEL (306 52-1 FAX: (305) 594-9279 wwvu. ran LOj tigineers.com DESI(rl D DATE JOB NUMBER 05- CHANDLER AND ASSOCIATES ARCHITECYTURE, P.A. AA 00W= LA" R CHANDLEK AIA Al NQ 1606b SOUTH MTAK FWRHM M43 TEL (306) 669-7992 FAX (" 669-7993 W W W.CI- AMLERARCHITEC'TURE.COM 00rj3 w mot NO. DATE AIR DISTRIBUTION SCHE%�ULE DESIG r0000ee000000_000lorso a asa.�osfo®�=Seoaor000s0000r NATION 1 C R L _ USE -------------+--SUPPLY---; REr!1I --}----------- CONST_RUCTION I ALUMIN131 I ALUMINIUM I I---------- _ SIZE-ISNOWN ON FLAN31--___-'� I _ TYPE - - - - - - - - - - - - --------___- J 24' x_2_4' mooUL�R ____r ______-- COMMENTS I DIRECTIONAL CEILING DIFFUSER I -----------------1---------J---------L-------- FINIS_H _ I _ALL _ALUMINIUM _ I ALL A_M LUMINIU__1 _ MOUNTING TYPE --___-I t -BAR_-�-- T-BAR _ NO SE CRITERIA 30 MAX 1 30 MAX I _ MANUFACTURERI METALAIR_E_ I MEtALAIn I ______ _ MODEL-----------i-- 5-0- --J--------RH L-------- A C_C E_S S 0 R I E S __ ___ ____ ____ 17 ________ O_PPO_S_E_D_B_LAD_E RE_GIST__L__ 0ap___J-_-------L-_-_---_ FIRE DAMPER __ I __ I - I CONNECTION SIZE - j SHOWN ON PLANO j -----------------T--------- 1------------------- -o 000as00000000000ir00000eoo�0000ee000ir000eoose NOTES 1. FINISHES AND TYPES OF MOUNTS SHALL BE COORDINATED WITH ARCHITECTURAL DRAWINGS. 2. PROVIDE SINGLE THICKNESS TURNING VANES AT ALL 900 RECTANGULAR ELBOWS AND DOUBLE THICKNESS TURNING VANES AT ALL 90* SQUARE ELBOWS, OR 3 PIECE ELBOWS. 3. PROVIDE VOLUME EXTRACTORS BEHIND EACH SUPPLY OUTLET AND AT EACH DUCT BRANCH SUPPLY OUTLETS MODEL - OBDC. DUCT BRANCH TAKE -OFF MODEL - AIRTROL MOD. 102 4. PROVIDE O.B. DAMPER AT ALL SUPPLY OUTLETS. 5. DUCT WORK TYPE -.--_ SEE A/C NOTES. 6. AIR PATTERN AND DIFFUSOR FACE SHOWN ON PLANS. 7. DIFFUSOR NECK SIZE SHOWN ON PLANS. (6x6, 9x9, 12x12, OR 15x15) HVAC DESIGN REQUIRES: YES NO Remarks DUCT SMOKE DETECTOR - FIRE DAMPER($) - $MOKE DAMPER(S) - _ - FIRE RATED ENCLOSURE - - - FIRE RATED ROOF/FLOOR CEILING A$$EMBLY FIRE STOPPING - - - $MOKE CONTROL - - - TERMINAL UNIT SCHEDULE ee DESIGNATION eeeeeeeeeeeeeeeew�eee 8 eee -- -4 -- __ QUANTITY IVE_RIFY_-_P_R_OV_ID_EPER PLA_N_SL7_ SEE PLAN__ LOCATION _,_PERIMETER _ _-AREA SERVED ---------------- --SIDETI- OAF_ __ OPERATING WEIGHT 1_____ MANUFACTURER ETI MODEL No. I_ VVR_1006__ G E N ERAL DATA _ --jyp_�-----------------------l-Fp.l____ DESIGN_ AIR_FLOW_,_ CFM______ MINIMUM_ DESIGN_ AIR FLOW _CFM ---MAXIM.�BFS�� QBQP�._ »�-0 - - - -- 0.06 ---- __ INLET_ STATIC PRESSURE, __TI 0 __ - STATIC_PRE_SS_UR_EL_"H O______ DESIGN SOUND LEVEL,_ NC_____ 20 INLET CONNECTION SIZE _ IN._______1___10'0____ H__E A _T_I N _G ______________ ____ ___ -- HEAT,[FAN_, CFM ______________1---400--- ELECTRIC RESISTANCE _KW +___WA ___ INDUCTION FAN HP _ ________ I __ 1/6 HP ELECTRICAL SEg�CE AV AIIABLE______1__2_1M60Q A C_C E S S 0 R I E S __________________ __ R,�A PLENVM_FILTER ___________ -r __ ___ ----L___--____ -------------------------- AUT_0_MATIC CONTROLS TYPE DESCRIPTION T-- NOTES: ALL VAV BOXES ARE ELECTRONIC - PREWRE INDI=PENDENT. F.P.I. z FAN POWERED INDUCTION 50XE8 MODEL 400 W. SIXES A$ SCHEDULED 0 PROVIDE WITH 211/120 TRANWORMER FOR ELECTRICAL SERVICE, NOTE: I: FAN PERFORMANCE SELECTED 0 MAXM CM a 025 ESP. PROVIDE FILTER SECTION W/ FILTER ON FPI. FEY1801 I NO. DATE PEVISION DRAWING TITLE: 'l/ H.V.A.C. NOTES and SCHEDULES SUITE 515 SCALE- DATE. PROJECT 140 2005.1 DRAWING NO Alw