Loading...
05-1438-002Air System Sizing Summary for AHU-5 Frcjact Name: 05-176 PLAZA-57 (SUITE 515) 10/12/2005 Prepared by: FRANYIE ENGINEERS INC. 01:03PM Air System information AirSystem Name --------------- ........ .-------- ---- .............. .• AHU-5 Number of zones ----------- ------- ------. --- . --- ---------------------------- Equipment Class -------------------- ---------------_---..... SPLT AHU Floor Area ............ •---------........ ------------...--------..._.2528.0 ft2 Air System Type --------------------------------- - -- ............ SZCAV Location ........................ -------....................... Miami IAP, Florida Sizing Calculation Information Zone and Space Sizing Method: Zone CFM Sum of space airflow rates Calculation Months ........ ___ ........... ............ ..._....... ....Jan to Dec ............................. Space CFM...._.................. Individual peak space loads Sizing Data ............................ ....................................... Calculated Central Cooling Coil Sizing Data Total coil load ................. .• - ----- /.. 9.0 Tons Load occurs at . - _.-- ........................... Jul 1300 ------------ Total coil load _-_-_--------------.... .............�.7 147 MBH OA DB / W B .......------------------------- --.......... --------.89.7176.7 IF -------- Sensible coil load ...............--------- ...._.._.......... ..... 89.4 MBH Entering DB / W B ......................... ............... ...........79.3 / 64.0 IF Coil CFM at Jul 1300_ .................----.----- ..........__... 3221 CFM Leaving DB / W B----------- ._..................... ................... -.53.6 / 52.3 `F . Maxblock CFM ----- -- ........_ ... ----- . 3221 CFM Cgii ADP ------------------------ ........... .............................. ---- 50.8 IF ..................... Sum of peak zone CFM .--_-----------------------_._....__........ 3221 CFM Bypass Factor-.*, ---- ..... - 1- ........... --- - _ - _..........- -.... 0.100 Sensibleheat ratio 0.830 Resulting RH----------------------._.......... ------------_-_-__ - ............._ 40 % ........................................................... W/Ton -_.....- -----...... .._.. 281.6 Design supply temp.... ---------- ----------- --------- --............ ...... 55.0 IF ........................__...-------------_-- STU/(hr-ft2) - . ----- --- . •........---------- ........... ........ 42.6 Zone T-stat Check ------------------------------- _............... ---------0 of 1 OK Water flow @ 10.0 IF rise ................................................ N/A Wax zone temperature deviation ............. ................. ............ 0.0 IF Central Heating Coil Sizing Data Max coil load --•...................... - .............. 23.5 MBH Load occurs at ------- ........ ....... Des Htg ..-- Coil CFM at Des Htg------------------_-- - ................ 3221 CFM BTU/(hr-ft2) ........__--------------- ----------------- ..... 9.3 Max coil CFM . ---- --.... -............ ......------ ------ .......--...... 3221 CFM Ent. DB / Lvg DB ............ -._............. .--------------- .. 67.2 / 73.9 IF Water flow @ 20.0 IF drop ............................................... N/A Supply Fan Sizing Data Actual max CFM -------•--- --------- ----- 3221 CFM Fan motor BHP ................ ...................................... .------- ......... 1.88 BHP ....... Standard CFM .---........ ...... -- -----------_...._._._.. 3220 CFM Fan motor kW . ........ --------------- ___ .............. ...... .._..._.---.1.40 kW Actualmax CFMJft2 ...................................... .............1.27 CFM/ft2 Fan static--.......................................................... ........... - --. 2.00 in wg Outdoor Ventilation Air Data Design airflow CFM.. ------------- ------.......................... 360 CFM (CFM/person ................ ............... - ..............-- ...__.. 20.00 CFM/person CFM/ft2------------• ................. .............-•------------_--------.._.. 0.14 CFM/ft2 Hourly Analysis Program v.4.2 Pago I of t"' 1