Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
6835 SW 67 ST EB-09-057-015
La La C\2 co co 0 �. c-D q CYD o F====1 CO a 125 ® "' LO cri ca IRRIGATION NOTES AND SPECIFICATIONS IRRIGATION LEGEND STATIONS LEGEND IRRIGATION E U I PM ENT LEGEND C b 01. All work to be installed according to local and county codes by a licensed and insured SYMBOL BRAND MODEL RISER NOZZLE RADIUS DESIGN FLOW PRECIPIT. STATION# GPM o BODY PATTERN PRESSURE G.P.M. RATE 1 38.37 irrigation contractor (contractor). Contractor shall include all labor, materials, and equipment 2 4 7 Code Brand Description Size '= ® TORO MPR570 6" 8'r-1 5'r 1 5'R 40 P.S.I. 0.26-1.45 1.75 necessary to complete the work detailed and intended in this plan. 3 47.95 02. It is the contractor's responsibility to visit the site and become familiar with the existing ® TORO MPR570 6" 8'r-1 5'r H 1 5'R 40 P.S.I. 0.58-2.02 1.75 4 42.14 TORO Greenkeeper 212 Series Controller 6 stations co ® TORO MPR570 6" 8'r-1 5'r TO 1 5'R 40 P.S.I. 0.86-3.00 1.75 f conditions prior to entering into contract with the Owner or General Contractor. 5 45.04 O ® TORO MPR570 6" 8'r-1 5'r F 1 5'R 40 P.S.I. 1.16-4.20 1.75 6 20.00 TORO Rain Sensor N/A o 03. All materials, quantities, sizes, and all other information contained in this plan shall be O verified by the contractor prior to entering into contract with the Owner or General Contractor. TORO MPR570 6" 4-EST 5'X 18' 40 P.S.I. 0.53 1.55 0 TORO Series 252 Electric Valves 1 1/4"- 2" =4==) O -" ❑ TORO MPR570 6" 4S-SST 4'X 18' 40 P.S.I. 0.63 1.55 IRRIGATION SIMBOLS LEGEND %°. This plan is diagramatical and therefore site condition and the scale of the plan may affect the R ® TORO 340 series 12" 01 1 WR 40 P.S.I. 0.57 0.75 ❑ TORO Pump Relay N/A -,; exact location of the system components. The contractor shall modify and/or adjust the @ MASTER VALVE TORO 340 series 12" 01 1 WR 40 P.S.I. 1.14 0.75 © a system as required so as to comply with full coverage design intent. Should the contractor # STATION VALVES - Single Phase Electric Pump 60 GPM TORO 340 series 12" 01 16'R 40 P.S.I. 1.71 0.75 0 �✓ find a discrepancy, error or omission he shall contact the Landscape Architect immediately. - - - Schedule 40 PVC Pipe - Main Line As shown • TORO 340 series 12" 01 16'R 40 P.S.I. 2.28 0.75 K] 6 ZONE IRRIGATION CONTROLLER b f' 04. Piping in islands or narrow beds shall run to one side of the island or bed to allow for - - - Class 200 PVC Pipe - Lateral Lines As shown ❑O CU TORO 340 series 12" 03 28'R 40 P.S.I. 1.36 0.75 S RAIN SENSOR planting. This includes mainlines and electrical wires. Piping and wiring should be installed Schedule 40 PVC Pipe - Sleeves As required-` TORO 340 series 12" 03 28'R 40 P.S.I. 2.72 0.75 after all the large plant material has been installed. ® Pump Relay Note: Irri Irrigation Contractor may substitute the brand names ecified for 05. The Landscape Architect has the right as Owner's authorized representative to at any stage ❑• TORO 340 series 12" 03 28'R 40 P.S.I. 4.07 0.75 g Y p Q TORO 340 series 12" 03 28'R 40 P.S.I. 5.43 0.75 Q BACKFLOW PREVENTER another brand however, the same performance is required for each •� of the works, A inspect, accept or reject any and all work and materials which, in his opinion, substitution.Irrigation Contractor shall verify the G.P.M. discharge do not meet the requirements of the design intent. @ MASTER VALVE 06. All bellow ground pipe shall be polyvinyl chloride) (PVC) pipe comforming to ASTM EQUIPMENT requirements for the irrigation pump, it shall meet the individual stations o # NUMBER DENOTES SPRAY HEAD RADIUS flow requirements, considering friction losses. M specification D 1785, Schedule 40, or it may be PVC pipe conforming to ASTM D 2241, 1 . EQUIPMENT MOUNTING CHECK VALVE Class 200. Irrigation equipment are to be located next to pump location as shown in plan. The equipment, 07. All PVC fittings shall be Schedule 40, Type 1, NSF Approved conforming to the ASTM D 2466 requirements, except as noted in the drawings. shown in plan and typical electrical schematic diagram shall be mounted onthe building wall or on IRRIGATION 08. All sprinkler heads shall meet the performance called for in this plan, and shall all be from a Unistrut frame set into a 16" x 10" deep concrete footing x 6" longer than both ends of the CONTROLLER one single manufacturer. Although all shrub heads are specified as 15' radius shrub heads, Unistrut structure's length. RAIN 24 V 3#12 IN 1/2"C SENSOR IRRIG. 3#6 THW/CU IN 1"C, contractor shall according to site conditions and space requirements, use a different radius 2. WORK PERFORMANCE: WIRE ELECTRICAL PANEL head or in some cases a different pattern head. XP-300 series sprinklers are shown as one All electrical work to be performed by a licensed and insured electrical contractor, in strict tib a a� m m model, Contractor shall use adjustable part-circle as required. Spacing shall also be adjusted 24 V GROUND o 0 compliance with all sections of Article 680 of the National Electrical Code Latest Edition. S C 24 V 1. 0 a o W so as not to overthrow water into impervious areas. CONTROL [WIRE(COMMON) ZONE 24V ELECT. m Ma o d O v o o W o 13,09. All valves shall be installed inside a plastic valve box of a size proper to the valve(s) size. WIRES VALVES (QUANITY "13 °�aro 0 5 Am m 0 Valve boxes shall be installed over 3" of gravel for drainage and the top level with finished REQUIRED AS SHOWN .0 a a CIO o o grade. 1#8 THW/CU IN 1/2"C L IN PLAN) W B a� m " �m� -off m•� o• ou 10. All wire to/from controller to the electric valves shall be #14, direct burial underground (GROUND PER NEC) PUMP L m o° .P 'MIA -"w v°m o feed type. All connections shall be waterproof direct burial connectors and splices. All wire 2-5/8"x10' CU/CLAD RELAY R 3 #8 0+� ° v°'m W a 3/4" C ZONE 24V vHU�oUm0� ��gti �o shall be placed bellow the PVC pipe for protection of the wire, and shall be placed loosely to GROUND RODS ELECT. 4 �" a q� m w allow for contraction. v 11. Thurst blocks shall be placed at all changes in direction of the main line. ' MIN MASTERVALVE ob a 0� o a ab 12. Trenching backfill shall be free of rocks, stones, or any other debris which may damage 24 V IRRIG. WIRE PVC PIPE AS z "� ro "c"H a the system components. o SPECIFIED IN 13. Risers shown are to be 6" in sod areas and 12" minimum in areas of round covers.The IRRIGATION PUMP PLAN g Y HECK VALVE shall be installed so that the shrub head operates above the ground cover's adult's height. (grounded) Contractor shall consult with Landscape Architect an specific height of plants prior to TO WELL installation. 14. Contractor shall coordinate with General Contractor, the installation of sleeves under all IRRIGATION SCHEMATIC DIAGRAM paved areas prior to their installation. N.T.S. 15. Backflow preventer if required shall be placed 18" min, above the highest sprinkler head. 16. Contractor shall, prior to installing the irrigation heads, flush all lines with the maximum Q water pressure available, to remove dirt and grit. Lines shall be pressure tested at 150%of O their operating pressure for leaks, and all leaks shall be repaired. This shall be done prior to w backfilling. 17. Contractor is responsible for keeping the work premisses clean of debris, and for removing all debris caused by his work from the site. MPR PLUS NOZZLES 4" MAX. (SIZE PER PLAN) PLASTIC VALVE BOX WITH COVER MARKED -NOTE: INSTALL SPRINKLER "IRRIGATION" AT FINISHED GRADE I II I I I I II_ APPROVED BACKFILL 1/2" IN TURF AND 2" EPDXY FILLED IN GROUND COVER CONNECTORS NOTE: CONTRACTOR AREAS -MAY INSTALL PIPE TO FINISH GRADE SIDE INLET LATERAL LINE (COVER SOLENOID ACTUATED AS NOTED) - SPRAY SPRINKLER BODY REMOTE CONTROL VALVE COMMON WIRE(PROVIDE 4" x 2-1/4" x 8" SOLID 24" OF WIRE IN A COIL) IN BARBED MALE ELL BRICK AT EACH CORNER 2" PVC CONDUIT. -FUNNY PIPE COMMON AND CONTROL MAINLINE(COVER AS WIRES (PROVIDE 24" OF NOTED IN LEGEND LATERAL PIPE WIRE IN A COIL, EA.) o LATERAL TEE SCH 80 PVC NIPPLE CD V) w MAINLINE(COVER AS NOTED) W NOTE: USE 45 ELLS IMMEDIATELY OUTSIDE OF VALVE BOX, AS 12" POP-UP SPRINKLER ON NECESSARY, FOR TRANSITION TO REQUIRED LATERAL LINE DEPTH. W POLY PIPE SWING JOINT DETAIL REMOTE CONTROL VALVE DETAIL we N.T._S. N.T.S. Lo PEI coo OUTSIDE WALL FINISH GRADE. C Z r_0 V) ;,: .,..:•;.,,�::.,._..... U.V. STABILIZED VALOR O -6 _ THERMOPLASTIC HOUSING IRRIGATION CONTROLLER BUNDLE IRRIGATION CONTROL WIRES LU AS SPECIFIED IN PLAN. UNDER PIPES AT 10' INTERVALS AND -'p CLICK STOP SETTINGS - MEASURE RAINFALL PROVIDE 1' EXPANSION LOOP AT 50' ON z IN QUANTITIES OF 1 /8"TO 1" o INTERVALS. 0 Q ADJUSTABLE VENTILATION HOLES W BACKFILL WITH PREVIOUSLY >O EXCAVATED MATERIAL. `> m 2� :x. aaaa SAND OR FINE MATERIAL ? " PIPE PASSING 1 /4" SIEVE. L q - m 1.5-INCH PVC SCH 40 PIPE OR CONDUIT(TYP.) 1 3"1 1 1 1 1 3„ CONDUIT AND FITTINGS 4" 6" FOR PIPE 2"AND SMALLER AND 12" FOR PIPE OR CONDUIT 2" AND ALUMINUM MOUNTING BRACKET ® JUNCTION BOX FOR PIPE 2 1/2" AND LARGER WHERE SMALLER AND 12" FOR PIPE 2 1/2"AND TOTALLY SEALED& LEAD WIRES 1-INCH PVC SCH 40 CONDUIT .® WEATHERPROOF SWITCH 0 CONTROL WIRE IS IN SAME TRENCH - IF TO POWER SUPPLY LARGER, WHERE NO WIRES IN TRENCH. MECHANISM (U.L. LISTED) ONLY ONE PIPE IN TRENCH, PROVIDE 5" WIRES TO REMOTE ;> TO TRENCH WALL. �JgFl AMAVY �9 [�1G CONTROL VALVES <<<< RAIN SENSOR DETAIL WALL MOUNT CONTROLLER DETAIL o 0 TRENCHING DETAIL N.T.S. N.T.S. 00 N.T.S. o rd _ N U U •U-a CO �a Orlando Comas A.S.L.A. SEp, _ -,---Esc-� •� U LANDSCAPE ARCHITECT ,:, L: 0 7428 SW 48th Street, � :, `�. } sheet no. Miami, Florida, 33155 Phone: (305)283-9382 - State Lic. No. LA1565 e-mail ocomas @bellsouth. i'1 r�