Loading...
6835 SW 67 ST EB-09-057-007 m LO !6/ N CD 0 LO Ca co 0 C+3 C� v f l ca ed IRRIGATION NOTES AND SPECIFICATIONS IRRIGATION LEGEND STATIONS LEGEND IRRIGATION E UIPMENT LEGEND 01. All work to be installed according to local and county codes by a licensed and insured SYMBOL BRAND MODEL RISER NOZZLE RADIUS DESIGN FLOW PRECIPIT. STATION# GPM UD irrigation contractor (contractor). Contractor shall include all labor, materials, and equipment BODY PATTERN PRESSURE G.P.M. RATE 1 8.37 \ o e TORO MPR570 6" 8'r-1ST 1 5'R 40 P.S.I. 0.26-1.45 1.75 43.07 Code Brand DesCrl tion Size d, " necessary to complete the work detailed and intended in this plan. 3 47.95 ' ® TORO MPR570 6" 8'r-1 5'r H 1 5'R 40 P.S.I. 0.58-2.02 1.75 ® � � 02. It is the contractor's responsibility to visit the site and become familiar with the existing 4 42.14 TORO Greenkeeper 212 Series Controller 6 stations LO conditions prior to entering into contract with the Owner or General Contractor. ® TORO MPR570 6" 8'r-15'r T 1 5'R 4fl P.S.I. 0.86-3.00 1.75 5 45.04 S C, ® TORO MPR570 6" 8'r-1 5'r F 1 5'R 40 P.S.I. 1.16-4.20 1.75 TORO Rain Sensor N/A f 03. All materials, quantities, sizes, and all other information contained in this plan shall be IRRIGATION SIMBOLS LEGEND o ® TORO MPR570 6" 4-EST 5'X 18' 40 P.S.I. 0.53 1.55 ® O %< verified by the contractor prior to entering into contract with the Owner or General Contractor. TORO Series 252 Electric Valves 1 1/2"- 2" 43 0 ❑ TORO MPR570 6 4S-SST 4'X 18 40 P.S.I. 0.63 1.55 ® MASTER VALVE This plan is diagramatical and therefore site condition and the scale of the plan may affect the O TORO 340 series l 2" O1 16'R 40 P.S.I. 0.57 CL75 ® TORO Pump Relay e r-q exact location of the system components. The contractor shall modify and/or adjust the @ STATION VALVES N/A =-% ® TORO 340 series 12" O1 16'R 40 P.S.I. 1.14 0.75 system as required so as to comply with full coverage design intent. Should the contractor � 6 ZONE IRRIGATION CONTROLLER © - Self-Priming,Single Phase Electric Pump 60 GPM ® TORO 340 series 12" 01 16 R 40 P.S.I. 1.71 0.75 find a discrepancy, error or omission he shall contact the Landscape Architect immediately. - - _ • TORO 340 series 12" Ol 16'R 40 P.S.I. 2.28 0.75 ® RAIN SENSOR Schedule 40 PVC Pipe - Main Line As shaven 04. Piping in islands or narrow beds shall run to one side of the island or bed to allow for - - b ❑O TORO 340 series 12" 03 28'R 40 P.S.I. 1.36 0.75 ® Pump Relay - Class 200 PVC Pipe - Lateral Lines As shown . planting. This includes mainlines and electrical wires. Piping and wiring should be installed TORO 340 series 12" 03 28'R 40 P.S.I. 2.72 0.75 - - - Schedule 40 PVC Pipe - Sleeves As required � V BACKFLOW PREVENTER after all the large plant material has been installed. Ff TORO 340 series 12" 03 28'R 40 MASTER VALVE P.S.I. 4.07 0.75 Note: Irrigation Contractor may substitute the brand name specified for 05. The Landscape Architect has the right as Owner's authorized representative to at any stage M � TORO 340 series 12" 03 28 R 40 P.S.I. 5.43 0.75 @ another brand however, the same performance is required for each of the works, A inspect, accept or reject any and all work and materials which, in his opinion, do not meet the requirements of the design intent. e# NUMBER DENOTES SPRAY HEAD RADIUS substitution.Irrigation Contractor shall verify the G.P.M. discharge 0 U I requirements for the irrigation pump,it shall meet the individual stations o 06. All bellow ground pipe shall be poly(vinyl chloride) (PVC) pipe comforming to ASTM . CHECK VALVE o7 specification D 1785, Schedule 40, or it may be PVC pipe conforming to ASTM D 2241, 1 . EQUIPMENT MOUNTING flow requirements, considering friction losses. Class 200. Irrigation equipment are to be located next to pump location as shown in plan. The equipment, 07. All PVC fittings shall be Schedule 40, Type 1, NSF Approved conforming to the ASTM D 2466 requirements, except as noted in the drawings. shown in plan and typical electrical schematic diagram shall be mounted onthe building wall or on IRRIGATION 08. All sprinkler heads shall meet the performance called for in this plan, and shall all be from a Unistrut frame set into a 16" x 10" deep concrete footing x 6" longer than both ends of the CONTROLLER one single manufacturer. Although all shrub heads are specified as 15' radius shrub heads, Unistrut structure's length. RAIN 24 V 3#12 ►N 1/2"C contractor shall according to site conditions and space requirements, use a different radius 2. WORK PERFORMANCE: SENSOR IRRIG, 3#6 THW/CU IN 1"C" WIRE ELECTRICAL PANEL head or in some cases a different pattern head. XP-300 series sprinklers are shown as one All electrical work to be performed by a licensed and insured electrical contractor, in strict model, Contractor shall use adjustable part-circle as required. Spacing shall also be adjusted 24 V GROUND oro �. � m 40 compliance with all sections of Article 680 of the National Electrical Code, Latest Edition. S M24 V a 4 so as not to overthrow water into impervious areas. WIRE (COMMON) " ° , a W 09. All valves shall be installed inside a plastic valve box of a size proper to the valve(s) size. ONTROL ZONE 24V ELECT. oA o 04 9 m °0 g W o IRES VALVES (QUANITY a o �*' �'.5"a"m Valve boxes shall be installed over 3" of gravel for drainage and the top level with finished 7 PM.0 o . x o REQUIRED AS SHOWN to'd 0°07 q g3, M W�� grade. 1#8 THW/CU I N 1/2"C Q W t IN PLAN) 10. All wire to/from controller to the electric valves shall be #14, direct burial underground (GROUND PER NEC) PUMP e „_6 b M,8 W-w" o�o v feed type. All connections shall be waterproof direct burial connectors and splices. All wire 2-5/8"x10' CU/CLAD RELAY R 3 #8 # o .5�"°x 0 0, m'0 w q °od p 3/4" C ZONE 24V m • ° 4J P�' IN shall be placed bellow the PVC pipe for protection of the wire, and shall be placed loosely to GROUND RODS ELECT. ° a�q 2�.M a m m allow for contraction. u 0 o m m�°w " P MASTERVALVE w o p .:6 7 ° B a 1 11. Thurst blocks shall be placed at all changes in direction of the main line. ' MIN H R o r h " m a 12. Trenching backfill shall be free of rocks, stones, or any other debris which may damage 24 V IRRIG. WIRE PVC PIPE AS °z g .0 v °5 o the system components. o SPECIFIED IN p 13. Risers shown are to be 6" in sod areas and 12" minimum in areas of ground covers.They IRRIGATION PUMP PLAN shall be installed so that the shrub head operates above the ground cover's adult's height. (grounded) HECK VALVE Contractor shall consult with Landscape Architect on specific height of plants prior to TO WELL installation. 14. Contractor shall coordinate with General Contractor, the installation of sleeves under all IRRIGATION SCHEMATIC DIAGRAM LN paved areas prior to their installation. N.T.S. 15. Backflow preventer if required shall be placed 18" min, above the highest sprinkler head. 16. Contractor shall, prior to installing the irrigation heads, flush all lines with the maximum A water pressure available, to remove dirt and grit. Lines shall be pressure tested at 150%of a their operating pressure for leaks, and all leaks shall be repaired. This shall be done prior to O backfilling. 17. Contractor is responsible for keeping the work premisses clean of debris, and for removing all debris caused by his work from the site. MPR PLUS NOZZLES 4" MAX. (SIZE PER PLAN) PLASTIC VALVE BOX WITH COVER MARKED NOTE: INSTALL SPRINKLER "IRRIGATION" AT FINISHED GRADE I II 41MM A PPROVED BACKFILL 1 /2" IN TURF AND 2" EPDXY FILLED IN GROUND COVER CONNECTORS 9 �, NOTE: CONTRACTOR AREAS -MAY INSTALL PIPE TO FINISH GRADE LATERAL LINE(COVER SIDE INLET SOLENOID ACTUATED AS NOTED) - SPRAY SPRINKLER BODY REMOTE CONTROL VALVE COMMON WIRE(PROVIDE 4" x 2-1/4" x 8" SOLID 24" OF WIRE IN A COIL) IN -BARBED MALE ELL BRICK AT EACH CORNER 2" PVC CONDUIT. -FUNNY PIPE COMMON AND CONTROL MAINLINE(COVER AS Y WIRES(PROVIDE 24" OF NOTED IN LEGEND P -LATERAL PIPE WIRE IN A COIL, EA.) r _l M - LATERAL TEE SCH 80 PVC NIPPLE MAINLINE(COVER AS NOTED) W NOTE: USE 45 ELLS IMMEDIATELY OUTSIDE OF VALVE BOX, AS Z 12" POP-UP SPRINKLER ON NECESSARY, FOR TRANSITION TO REQUIRED LATERAL LINE DEPTH. W POLY PIPE SWING JOINT DETAIL REMOTE CONTROL VALVE DETAIL � N.T.S. N.T.S. x c� � F4 coo OUTSIDE WALL FINISH GRADE. :,`=,t:;_, :>.. >:•. _ U.V. STABILIZED VALOX THERMOPLASTIC HOUSING LU IRRIGATION CONTROLLER BUNDLE IRRIGATION CONTROL WIRES w ' J CLICK STOP SETTINGS - MEASURE RAINFALL AS SPECIFIED IN PLAN. UNDER PIPES AT 10 INTERVALS AND ® , PROVIDE V EXPANSION LOOP AT 50' Ln IN QUANTITIES OF 1/8"TO 1" INTERVALS. ®< ADJUSTABLE VENTILATION HOLES BACKFILL WITH PREVIOUSLY w> EXCAVATED MATERIAL. "u' ;`: ,s:. .'il _ ;„- - O 8 SAND OR FINE MATERIAL tY. .,', PIPE PASSING 1 /4" SIEVE. rn ...:-,.:.;,... .•.:�.,�.,�;�. .::-::. :•.<;•:<;:;.,:. 1.5-INCH PVC SCH 40 PIPE OR CONDUIT(TYP.) 13"1 1 1 1 1 1 T ® CONDUIT AND FITTINGS ALUMINUM MOUNTING BRACKET Go 6" FOR PIPE 2"AND SMALLER AND 12" JUNCTION BOX 4' FOR PIPE OR CONDUIT 2" AND FOR PIPE 2 1/2-AND LARGER WHERE LEAD WIRES p SMALLER AND 12 FOR PIPE 2 1/2"AND TOTALLY SEALED& 1-INCH PVC SCH 40 CONDUIT - CONTROL WIRE IS IN SAME TRENCH - IF WEATHERPROOF SWITCH 0 ONLY ONE PIPE IN TRENCH, PROVIDE 5" LARGER, WHERE NO WIRES IN TRENCH. MECHANISM (U.L. LISTED) TO POWER SUPPLY U) WIRES TO REMOTE TO TRENCH WALL. 1 81MW AMATAVMAWW 98RM. CONTROL VALVES i��* <<<< RAIN SENSOR DETAIL WALL MOUNT CONTROLLER DETAIL 0') J U TRENCHING DETAIL N.T.S. N.T.S. co 7) O N.T.S. O 0 Pd C.) o Orlando ComasA.S.L.A. SEAL: r " A�= 'co LANDSCAPE ARCHITECT d sheet no. 7428 SW 48th Street, Miami, Florida, 33155 Phone: (305)264-3841 State Lic. No. LA1565 ` L- 3ol e-mail: ocomas @bellsouth.net