6835 SW 67 ST EB-09-019-078 m ti I AIR � CO 2 �/ O 3 Ii// 7 " CAP FOR FUIURE OORNHEAT RECD�Y rHEAT TRAP ) \ O / GATE VALVE PLUMBING FIXTURE SCHEDULE ^wJ( © 6 GATE VALVE i l � CW INLET HEAT TRAP y rQ 7 Q nW� E%PAN'RON TANK MARK DESCRIPTION FIXTURE HOT COLD �--� co :i•i / OUTLET \\\\ rUNION �A,O.SMITH V-SEC Y PRESSURE UP TO 60 PSIG UNITS WATER WATER TRAP REMARKS LC) ^H/ A.O,SMITH V-12�(CITY PRESSURE ABOVE 60 PSI C) / PRESSURE&TEMPERATURE 1) FIXTURES TO COMPLY WITH REFERENCE STANDARDS AS PER FBC 2007 ��•7I\\ O p / - �REUEF VALVE(ASME APPRVD.) WC WATER CLOSET 3 --- 1/2" 3" PLUMBING SEC. 406 THROUGH 421. W O •y.% 6 O T 1 UNION-� O '. L LAVATORY 1 1/2" 1/2" 1 1/4" 2) RESIDENCIAL FIXTURES SHALL COMPLY WITH 2OD7 FBC Section P2707. 5 4 �•AIR OAP 3) ANTI-SCALD VALVE:ALL SHOWERS & BATH/SHOWER COMBINATIONS SHALL BE O 3 /4' 3" W/ANTI-SCALD VALVE v� SH SHOW 4 PROTECTED WITH A CONTROL VALVE OF THE PRESSURE BALANCE,THERMOSTSTIC DRAIN VALVE COMPLY 3/4DISCHARGE - �„-•, 1 ER 2 3/ '� 3 � •.�/ -RELIEF 2 ASSE 1005 UNETERMINATE 6•AeOVE , MIXING OR COMBINATION TYPE SET. HANDLE POSITION STOPS PER MANUFACTURERS �{ �•` m FIN.GRADE OUTSIDE THE T BATHTUB 2 INSTRUCTIONS AT TIME OF INSTALLATION TO A MAXIMUM MIXED WATER OUTLET 3/4' 3/4' 2' W/ANTI-SCALD VALVE �I 5 Q eunnlNC,SEE PLAN P-z TEMPERATURE OF 110' F. •e 4 O SK KITCHEN SINK 2 1/2" 1/2" 1 1/2" 4) ALL DRAINS 3"0 OR ABOVE SHOULD HAVE 1/8" SLOPE & BELOW 3"0 SHOULD HAVE 1/4" SLOPE. L� �FINISH FLOOR WM WASHING MACHINE 2 1/2" 1/2" 3" PROVIDE WM BOX W/(2) 5) ICE MAKERS, REFRIGERATORS & DRINKING FOUNTAINS TO BE IN LINE 6ACKFLOW DEVICE & FILTER. 1/2" HB & 2" DRAIN 6) DISHWASHING MACHINES SHALL CONFORM TO ASSE 1004 AND NSF3. WATER SUPPLY SHALL BE ELECTRIC WATER HEATER (TYPICAL) FD FLOOR DRAIN 2 - - 3" SEE PLAN PROTECTED WITH AN BACKFLOW DEVICE AND PROVIDE INDIRECT WASTE W/AN AIR BREAK. Nrs PROVIDE RESEALER 0 REF REFRIGERATOR 1/2" PROVIDE BACKFLOW DEVICE PLUMBING GENERAL NOTES AND SPECIFICATIONS: WATER HEATER-1 WATER HEATER-2 & FILTER IN LINE 1. A. SCOPE OF WORK: CD MANUFACTURER_LOCHINVAR MANUFACTURER_LOCHINVAR BD BIDET 1 � "'. MODEL_LTA066KK MODEL_LTA066KK i/2 1/2 2" THE WORK SHALL INCLUDE ALL PLUMBING NECESSARY SHOWN ON THE CAPACITY _65 GALLONS CAPACITY _65 GALLONS PROVIDE SOV& VAC. BREAKER DRAWINGS, SPECIFIED HEREIN AND/OR AS NEEDED FOR A COMPLETE DIMENSION-59-1/4% 22" DIMENSION_59-1/4% 22" HB HOSE BIBB 3/4" RECESSED IN WALL SYSTEM, INCLUDING BUT NOT NECESSARILY LIMITED TO: WEIGHT-156 POUND WEIGHT-156 POUND 4500 W, 240 VOLT, 16 PROVIDE INDIRECT WASTE 1.DOMESTIC COLD AND HOT WATER PIPING SYSTEMS EFFICIENCY-92%W, 240 VOLT, '� EFFICIENCY-92% DW DISHWASHER 2 1/2" 1 7/2' W AN AIR BREAK 2.SANITARY DRAIN AND VENT SYSTEMS (DREU CY_9C% ECIRCULATION PUMP SCHEDULE (2) 1 RELIEF VACUUM (D RELIEF VACUUM 3.PLUMBING FIXTURES AND TRIM 4.PRESSURE & TEMPERATURE RELIEF AND PAN DRAIN 2 RELIEF VALVE 2 RELIEF VALVE FROM WATER HEATER. 3 HWR PUMP 3 HWR PUMP MODEL: GRUNFOS UP-15-42F RECIRCULATOR PUMP (59896155) 5.PIPING INSULATION mom'"GO.- 04 3/4"HW U4- 3 4"HW 1/25 HP RECIRCULATOR PUMP 6.SUPPORTS AND HANGERS '� m'a a�m, FLOW RANGE: U.S.GPM p B. ALL PLUMBING WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE LATEST I,C m 5 3/4"MIX WATER 5 3/4"MIX WATER HEAD RANGE:O-15.5 FEET °•. 1 g EDITION OF THE "FLORIDA BUILDING CODE" AND LOCAL ORDINANCES AND IN "m¢ "o ° VCW M 6 3/4"CW COMPLIANCE WITH THE "FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING m b eon °;C 01 m O7 1'CW MAIN LINE 7 1-1 4'CW MAIN LINE MOTOR 2 POLE, SINGLE PHASE, 115 VOLT ,d m 9 w.d°°A„ •�'` TO WEST HOUSE AREA O TO EAST HOUSE AREA MAX. FLUID TEMPERATURE_230°F PLUMBING LEGEND CONSTRUCTION", AND "HRS" REGULATIONS. IN THE EVENT OF CONFLICT BETWEEN H "4 m'> CC,m m 8 EXPANSION TANK g EXPANSION TANK MIN. FLUID TEMPERATURE_36°F 2. CONTRACTORRTOEVERFY AT,SITEETHOERLOCATIONENELEVAQTIION ANOTSIZELOF ALL "m o°m��r,3N o g CHECK VALVE g CHECK VALVE 01' �A a r"n (D SHUT-OFF VALVE MAX. WORKING PRESSURE-145 PSI EXISTING LINES FOR CONNECTION BEFORE INSTALLATION OF ANY PIPING. m..+ mA�•y"m°¢ p SHUT-OFF VALVE 2 GASKET INCLUDED SANITARY SEWER LINE 3. UNDERGROUND METAL PIPING SHALL BE PROTECTED WITH A COAT OF BITUMINOUS ��mm o,„ o v 1 POWER SUPPLY TO 1 POWER SUPPLY TO VENT LINE COMPOUND BEFORE COVERING °a s°/°q s,as CON fjOL CLOC IL F R� CONTROL CLOCK(TIMER)FROM OPTIONAL DRINKABLE COLD WATER C.W. LINE 4. WATER-HAMMER ARRESTOS SHALL BE INSTALLED WHERE QUICK-CLOSING VALVES ""d o o� A v o O2 7-114'CW SUPPLY FR M MAIN LINE 2 7"CW SUPPLY FROM MAIN LINE GRUNDFOS 599388 24 HR PROGAMMABLE TIMER CLOCK, ( ) 3D,°RESSURE BALANCING VALVE 3 RESSURE BALANCING VALVE INDOOR WORK COLD WATER (C.W.) LINE ARE UTILIZED, UNLESS OTHERWISE APPROVED. WATER-HAMMER ARRESTORS SHALL H m°m u °a m CONFORM TO ASSE 1010. ACCESS SHALL BE PROVIDED TO WATER-HAMMER ARRESTORS. HOT WATER SUPPLY(H.W.S) LINE 5. ALL FLOOR DRAINS TO HAVE TRAP PRIMERS 1/2" LINE FROM THE NEAREST c GAS LINE PLUMBING FIXTURE. P&T-- WATER HEATER PAN DRAIN LINE 6. PLUMBING FIXTURES SHALL BE CONSTRUCTED WITH THE APPROVED MATERIALS, SHALL HAVE SMOOTH IMPERVIOUS SURFACES AND SHALL BE FREE FROM DEFECTS Q AND CONCEALED FOULING SURFACES, ALL FIXTURE TRIM TO BE CHROME PLATED. N 1.1 BALL VALVE FIXTURES SHALL BE PROVIDED WITH SUPPORTS, HANGERS, ETC. O x GATE VALVE 7. WASTE LINES 3" OR MORE, SLOPE ®1/8"/ FT. AND 2" AND UNDER, SLOPE® 1/4"/FT. 0 COLUMN OR PARTITION AS SHOWN ON FLOOR PLAN CORE BORE OPENING IN WALL VI CHECK VALVE 8. PROVIDE FULLY ACCESSIBLE CLEAN OUTS ON SANITARY AND ANY WASTE CLEANOUT FACE SHALL INTERIOR WALL. SIZED TO TIGHTLY FIT THE PIPING AT EVERY CHANGE OF DIRECTION, AND AT BOTTOM OF STACKS. PROVIDE TEST TEE BE WITHIN 4' OF WALL PIPE SLEEVE. PRESS. & TEMP. RELIEF VALVE CLEAN OUT LOCATIONS AND SIZES ON HORIZONTAL LINES SHALL BE WITH SCREWED COUNTER- SURFACE. PROVIDE ACCORDING TO CODE. WALL CLEAN OUT SUNK ABS PLASTIC PLUG: PIPE EXTENSION IF REQUIRED 20 GAUGE SHEET HB C--j-- HOSE BIBS SHALL NOT BE SEEN FROM ANY LIVING SPACE ROOMS, THEY MUST BE TAPERED-THREAD WITH METAL SLEEVE. IRE RATED CAULK OR EQUAL r TFE JOINT COMPOUND. TO DOW CORNING CP-25 FCO ® FLOOR CLEAN OUT LOCATED UNDER SINKS, LAVATORIES & CABINETS. I-1--I 2" THICK (EACH SIDE). 9. VENT LINES TO EXTEND 9" MIN. ABOVE ROOF AND FLASH WITH LEAD. WHERE CLEANOUT TEE PIPING WCO WALL CLEANOUT IS CONCEALED IN A 7-"-FILL 10. THE MAXIMUM WATER CONSUMPTION FLOW RATES AND QUANTITIES FOR ALL PLUMBING CHASE OR PARTITION, FILL AROUND SLEEVE FIXTURES FITTINGS SHALL BE IN ACCORDANCE WITH TABLE 604.4 F.B.C. PROVIDE A ROUND 18 FIBERGLASS INSULATION WITH CAULK. FD ® FLOOR DRAIN GAUGE STAINLESS STEEL OR MINERAL WOOL 11, CONTRACTOR SHALL COORDINATE WITH OWNER AMOUNT & LOCATION OF HOSE COVER WITH BEVELED EDGES AND FLATHEAD POINT OF CONNECTION. PRIOR TO INSTALLATION. MACHINE SCREW. /ti TRAP PRIMER (RESEAL) ZURN 12.PIPING CONCRETE • OR APPROVED EQUAL A. SUPPORT ALL PIPE FROM SOUND PORTIONS OF STRUCTURE AND AT PROPER FLOOR INTERVALS ACCORDING WITH CODE. V) SLAB T/l I TRAP (PVC SCHEDULE 40 WITH BOTTOM r V THREADED PLUG ZURN OR APPROVED B. PROVIDE SLEEVES FOR ALL PIPING PASSING THROUGH FOUNDATION SLABS OR w EQUAL MASONRY WALLS, CAULK OPENINGS BETWEEN PIPE AND SLEEVES. T ` INTERIOR WALL PENETRATION DETAIL C. WHERE EXPOSED PIPES PASS THROUGH FLOORS, WALLS, OR CEILINGS, PROVIDE v NOTE, NOT TO SCALE ESCUTCHEONS FIRMLY SECURED TO THE PIPES AND OF SUFFICIENT OUTSIDE PROVIDE WCO WHERE SHOWN ON PLAN, AND ON SANITARY WASTE BRANCHES DIAMETER TO COVER THE SLEEVED OPENINGS FOR THE PIPES. PROVIDE NOT SERVED WITH A FLOOR CLEANOUT: LOCATE ABOVE FIXTURE FLOOD RIM CHROMIUM PLATED ESCUTCHEONS IN BATHROOMS. WITHIN 4' OF FLOOR. CONSULT LOCAL CODES FOR OTHER WCO REQUIREMENTS. D. LOCATION OF FULL-OPEN VALVES. AS PER FPC 606.1 F. LOCATION OF SHUTOFF VALVES. AS PER FPC 606.2 P . WALL CLEANOUT DETAIL G. SANITARY WASTE, VENTS & STORM DRAIN SHALL BE STANDARD WEIGHT CAST a �- N.T.S. PROVIDE NICKEL BRONZE FLOOR EXTRA DEEP IRON NO-HUB PER CISPI STANDARDS 301 , WITH STAINLESS STEEL ONE-PIECE O C~ FLOOR PLATE TO BE COMPATIBLE ACCESS FRAME HEAVY-DUCTY NEOPRENE GASKETS. UNDER SLAB PIPING SHALL BE CAST IRON BELL AND 4. SURFACt \ W/TYPE FLOOR INSTALLED SECURED COVER SPIGOT PIPING WITH NEOPRENE GASKETS, OR A.B.I. "BEST" COUPLING. WHERE \ PERMITTED BY LOCAL AUTHORITY, APPROVED PVC OR ABS PLASTIC PIPE FLOOR H.�\ AND FITTINGS, PER ASTM D2661-89 OR D2665-89, MAY BE USED. Z CONDENSATE a SURFAC \ GASKETED ABS SCHEDULE 40 PIPE FROM FITTINGS. CONDITIONING UNITS: "PVC" P 1 Cfl CLEANOUT PLUG e ,.n I. DOMESTIC WATER ABOVE GROUND: TYPE L COPPER PIPE WITH WROUGHT W .. ­-4 � ..a: COPPER SOLDERED JOINT FITTINGS. TYPE K COPPER BELOW GROUND PIPE ACCORDING TO ASTM B-42. TUBE ACCORDING TO ASTM B-88. ALTERNATE FOR a" x UNDERGROUND PIPE: CAST IRON WATER PIPE ACCORDING TO ANSI A 21.5. co� STEEL PIPE (SCHEDULE 40, GALVANIZED) ACCORDING TO ASTM A120-68. W WOOD J. ALL CONTROL VALVES FOR DOMESTIC WATER SHALL BE CAST BRASS OR O DECK., B-88 BRONZE GATE VALVES. TURN LEAD DOWN INTO TOP BEAM ALL-THREAD ROD. STACK ANCHOR K PROVIDE DIELECTRIC FITTINGS FOR JOINING DISSIMILAR METALS. C-CLAMP LENGTH AS REQ'D L. ALL DOMESTIC WATER LINES HOT AND COLD, SHALL BE INSULATED AS PER FBC B STEEL FOR PIPE SLOP FLANGES SECTION 607.2. PLUMBING INSULATION SHALL BE AP/ARMAFLEX BAR JOIST. SHEET LEAD FLASHING. a F OR APPROVED EQUAL PROVIDE COPPER MAKE WATERTIGHT = OR NON-METALLIC � ADJUSTABLE COATING WHERE CLEVIS HANGER FOR a w EXTENSION TO BAND HINGE HANGERS CONTACT PIPE OVER FOUR INCH. = EXTERIOR 13.INSPECTIONS AND TESTS FOURPINICH BARE COPPER PIP O o LINIE OR WASTE A. CONTRACTOR SHALL BE RESPONSIBLE TO ASK FOR INSPECTIONS TO THE AUTHORITIES OR LESS. , HAVING JURISDICTION, AS THE WORK PROGRESSES. ALL SYSTEMS SHALL BE TESTED BY aaaa � CODE AND/OR LOCAL REGULATIONS, B. DRAINAGE PIPING: BEFORE INSTALLATION OF ANY DRAINS, THE ENDS OF SYSTEMS DO NOT HANG PIPE PROVIDE GALVANIZED STEEL SADDLE FOR ALL SHALL BE CAPPED AND ALL LINES FILLED WITH THE WATER TO THE HIGHEST LARGER THAN 3" FROM INSULATED PIPE LARGER THAN 3/4". VERIFY FLOOR HORIZONTAL LINE CHROME PLATED POINT AND ALLOWED TO STAND UNTIL INSPECTION IS MADE BY AN OWNER BOTTOM OF JOISTS. INSULATION THICKNESS WHEN SIZING HANGERS. SLEEVE ROOF CONSTRUCTION OR CLEANOUT BRONZE WALL REPRESENTATIVE. AS REQUIRED CLEANOUT DETAILS TEE PLATE C LIMEITO EACH WATER 1..000 GALLONS WATER MIXTURE(50OPM TWO OF(AVAILLABLE CHLORINE). PROVIDE UPPER ATTACHMENT AS REQUIRED FOR CASES NOT SHOWN HERE. INCREASER WHEN REQUIRED RETAIN MIXTURE IN PIPES 48 HOURS AND FLUSH THOROUGHLY WITH POTABLE WATER DO NOT INSTALL HANGER INSIDE INSULATION OR OTHERWISE PENETRATE N.T.S. CLEANOUT BEFORE PLACING IN SERVICE. f~- i VAPOR BARRIER. DO NOT HANG ONE PIPE FROM ANOTHER EXCEPT IN FINISH GRADE D. COMPLETE SYSTEM, FIXTURES AND EQUIPMENT SHALL BE GIVEN AN IN-SERVICE TEST 0 U) CHASES. TRAPEZE HANGERS MAY BE USED FOR MULTIPLE PARALLEL PIPES. � VENT STACK AFTER COMPLETION OF THE INSTALLATION. � HANGER SPACING FOR PIPE SIZE: COPPER: 4'=12'; 3"=11'; 2-1/2"=10'; -_ 2"-g'; 1-1/2"-8'; 1-1/4"=7'; 1"-6'; 3(4"=6; 1/2"=5'. CAST IRON: NOTES: r_I� aaaa 10' & ONE NEAR ALL JOINTS. STEEL: 4'-14'- 3"=12'; 2-1/2"=11'; 2"=10'; -I�I-I IIIII-IIII-II II-IIIII-I --III- 1-1/2"=9'; 7"=7'; 3/4"=6'; 1/2"=5'. LOCATE HANGERS AS CLOSE AS 1,) SIZE OF OPENING IN ROOF DECK TO BE AS SMALL AS POSIBLE. -�ItIi,I�1=�( �=�I III S•I POSSIBLE TO TURNS & TEES OF PIPE. PROVIDE SUPPLEMENTARY STEEL STRUTS CO-ORD. WITH STRUCTURAL DWGS. -i = I=III=I SOIL OR WASTE BETWEEN JOISTS IF REO'D. LOCATE HANGERS TO TAKE LOAD OFF OF EQUIPMEN EXTENSION SAME CONNECTIONS. ANCHOR WATER PIPE AGAINST SWAYING DUE TO CHANGES IN 2•) FOR ROOF CONSTRUCTION TYPE REFER TO ARCH. DWGS. SIZE AS SEWER Q L2 - WATER VELOCITY. PROVIDE SEISMIC BRACING IF/AS REQUIRED BY LOCAL �� 1-WAY LL Q o AUTHORITIES. CHAINS OR PERFORATED STRAP IRON OR STEEL IS NOT 3.) VENT STACK THRU ROOF SHALL BE LOCATED AT A MINIMUM 1-WAY CLEANOUT ACCEPTABLE. REFER TO CODES FOR FURTHER INFORMATION. OF 10'-0" AWAY FROM ANY OUTSIDE AIR OPENINGS. CONTRACTOR CLEANOUT NOTE: WALL SHALL COORDINATE WITH OTHER TRADES PRIOR TO CONSTRUCTION. INDOOR CLEAN OUT SHALL BE HIDDEN UNDER CABINETS AND INSIDE CLOSETS, COORIDATE WITH PIPE HANGERS DETAIL VENT STACK DETAIL ARCHITECT G N.T.S. NOT TO SCALE NOTE' -,--, 33137-080295 NOT AND FITTING SHALL BE OF THE SAME -«-� 4 d MATERIAL AS SEWER IT SERVES. '. U -0 EXTERIOR TWO-WAY CLEANOUT JOEI 090403 N.T.S. � sheet no. n1jr7p Amenlie Rodriguez,PE Dcense Number BD23B PLUMBING NOTES AND DETAILS ®engineering inc T� r G6hlee.Jourdonel,Sui F-/ 2855 Is le,RRaad,Suits 902 ba+amu u.wn: Signeuire 1 Coral Gables,ROride 33134 >MedeNd>e:u:I Phene>31)544498D9 >wmc:v >F..Pm ua, pare F. >304449827 w:A.v.erp-g.Gom 5 OF 5