Loading...
6835 SW 67 ST EB-09-019-073 P m r�i r w I O �1 O O DIFFUSER SCHEDULE TYPE SERVICE CFM RANGE SIZE NECK MANUFACTURER MODEL MIN MAX 0 100 6X6 6"0 TITUS 250 AA {!°J 101 200 10x8 8"0 TITUS 250 AA O 201 300 10x10 10'•0 TITUS 250 AA R O SUPPLY 301 400 14x10 10'•0 TITUS 250 AA 401 500 1404 12"0 TITUS 250 AA SPLIT A/C UNIT SCHEDULE m 501 700 16x16 12"0 TITUS 250 AA a �V -,i UNIT DESIGNATION AHU�jt AHU#2 AHU}{3 AHU$4 AHU#5 AHU#6 z` / 70 185 8X6 -- TITUS 350RS Partial 1st Floor Partial 1st Floor Partial 1st Floor Partial 1st Floor Partial 1st Floor Partial 1st Floor / l AREA SERVED Master Area West South South East Famil Ki g 186 225 10X6 -- TITUS 350RS y/Kitchen a SUPPLY, 226 240 8X8 -- TITUS 35ORS LOCATION A/C CLOSET A/C CLOSET A/C CLOSET A/C CLOSET A/C CLOSET A/C CLOSET y °m SIDE DICH. LOUVER 241 270 12X6 -- TITUS 35OR5 DESIGN MANUFACTURER TRANE TRANE TRANE TRANE TRANE TRANE 271 295 14X6 -- TITUS 350RS MODEL NO. 4TEE3D07B1 4TEE3DO5B1 4TEE3D07B1 4TEE3DO5B1 4TEE31)07B1 4TEE3DIOB1 rn 296 340 12X8 -- TITUS 350RS SEER 20.0 20.0 20.0 20.0 20.0 1 20.0 „i TOTAL AIR, CFM 1,600 1.200 1,600 1,200 1,600 1,800 D 100 8x8 TITUS 350__ FL EXT. STATIC PRESS., INCHES OF H2O 0.4 z 0.4 0.4 p,q 0.4 0.4 FAN MOTOR H.P. (NON-OVERLOAD) 3/4 1 2 3/4 1 2 3/4 1 2 101 200 12x10 -- TITUS 350 FL / ELECTRIC HEAT, KW 7.0 4.0 5.5 5.5 7.0 7.0 i 201 300 12x12 -- TITUS 350 FL z TOTAL CAPACITY, BTUH 47,000 35,800 47,000 35,800 47,000 58,500 "s HVAC NOTES 301 40D 14X14 -- TITUS 350 FL s TOTAL SENSIBLE CAPACITY, BTUH 34,800 27,400 34,800 27,400 34,800 40,500 RETURN EXHAVS 401 50D 1BX14 -- ¢ ENTERING AIR TEMP. F DB/WB 80/67 gp g7 80/67 / 80/57 80/67 80/67 of T C I. GENERAL O T1TU5 350 FL --- --- --- --- --- --- v v r.+0 a CEILING COIL MODEL N0. w 0 p,,, OR SIDE WALL 501 600 24x14 __ TITUS 350 FL 00" - A. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE FLORIDA FLA/RLA 6.8 4.3 6.8 4.3 6.8 4,3 '��y'�0'-a v A-a BUILDING CODE AND 1WTH ALL APPLICABLE REGULATIONS. 601 700 32x12 -- TITUS 350 FL ELECTRICAL SERVICE 208-230/1/60 208-230/l/60 208-230 1 60 // 208-230 1 60 208-230/1/60 208-230/1/60 ,a . •.. B. DRAWINGS: REFER TO ALL DRAWINGS FOR COORDINATION OF THE HVAC WORK. b k v°a1 v a C. ARRANGE AND PAY FOR ALL PERMITS LICENSES,INSPECTIONS AND TESTS. 701 1000 36x12 TITUS 350 FL OPERATING WEIGHT, LBS. 176 130 176 130 176 121 v �'�u j q OBTAIN THE REQUIRED CERTIFICATES AND PRESENT TO OWNER. 1001 1800 30x18 UNIT DIMENSIONS H % W % D (IN) 58 X 26 X 27 52 X 26 X 21 58 X 26 X 21 52 X 26 X 21 58 X 26 X 21 63 X 26 X 21 I.f1 v�pp 0 o-b o y a '�✓% D. GUARANTEE: THE COMPLETED INSTALLATION SHALL BE FULLY GUARANTEED -- TITUS 350 FL WW�+•,q d g m. w., v / 1801 2000 36x34 UNIT DESIGNATION F,+ '{m 5 m AGAINST DEFECTIVE MATERIALS AND/OR IMPROPER WORKMANSHIP FOR CU#1 CU#2 CU#3 CU#4 CU#5 CU#6 p u v a d aCC o MINIMUM OF ONE YEAR FOR MATERIAL AND LABOR. COMPRESSORS SHALL BE -- T1TUS 350 FL DESIGN MANUFACTURER TRANE TRANE zy m o a B m GURANTEED FOR A PERIOD OF FIVE YEARS. TRANE TRANE TRANE TRANE MODEL N0. 4TTZ0048A1 (XI-201) 4TTZ0036A7 (XI-201) A v+A •° •q°� E. AS BUILT DRAWINGS SHALL BE SUBMITTED TO OWNER AT THE COMPLETION AREA/DUCT WITH ( ) ( ) 4TTZ0048A1 (%L201) 4TTZ0036A1 (%L201) 4TTZ0048A1 (XI-201) 4TTZOO60A1 (XI-201) u 9 a m Y Ttl o y OF PROJECT. NOMINAL CAPACITY (TONS) 3.0 3.0 ��ma v o d ti 4.0 4.0 4,0 5.0 P1 2. SHOP DRAWINGS: CONTRACTORS SHALL SUBMIT FOR APPROVAL,WITHIN 30 DAYS 25 CFM/LF 0.0485F/2" -- TITUS CT-480 t= TYPE OF FAN PROPELLER PROPELLER M q H 0 SUPPLY LINEAR _ PROPELLER PROPELLER PROPELLER PROPELLER p, AFTER SIGNING CONTRACT,A MINIMUM OF FIVE COPIES OF FULLY DESCRIPTIVE o 50 CFM/LF 0.O66SF/2.5' - TITUS CT-480 bp o .�.o v o O BAR __ cy NO. E FANS AND HP 1-1/3 1-1/3 1-1 3 1-1/3 1-1 3 1-1 3 Al d a ti.v4 v t,v LITERATURE,INCLUDING BUT NOT LIMITED TO:FANS,AIR CONDITIONING UNITS,AIR OUTLETS. 90 CFM/LF 0.121SF/4" TITUS CT-480 F NO WORK SHALL PROCEED WITHOUT APPROVAL OF THESE SUBMITTALS.IF APPLICABLE. z CONDENSING TEMP., F DS 125 CFM/LF 0.157SF/5" -- TITUS CT-480 - 95' 95 95' 95' 95' 95' o N0. OF COMPR S 3. DESIGN PARAMETERS: 150 CFM/LF 0.194SF/6" -- TITUS CT-480 z 1/SCROLL 1 SCROLL 1/SCROLL 1 SCROLL 1/SCROLL 1/SCROLL A. OUTDOOR DESIGN TEMPERATURE SUMMER: 917 D8 AND 777 WE o COMPRESSORS R,L.A. L.R.A. ( ) z 18.6 93.4 73.8 61.5 18.6 93.4 13.8 61.5 18.6 93.4 22.8 728.7 B. OUTDOOR DESIGN TEMPERATURE(WINTER): 46F CAPACITY REDUCTION Q C. INDOOR DESIGN TEMPERATURE(SUMMER): 75F DB AREA/DUCT NTH 0- 007 0-100% p_ ppy, 0-1009; 0- 00% 0-100% ( o MCA MOCP _ D. INDOOR DESIGN TEMPERATURE WINTER): 70F OB __ w 26 40 19 30 26 40 19 30 26 40 31 SD 40 CFM/LF 0.0665F/2.5 TITUS CT-480 o ELECTRICAL SERVICE N I� RETURN LINEAR __ 208-230/l/60 208-230/1 60 208-230/l/60 20B-230/1/60 208-230/l/60 208-230/1 60 O 4. ALL THERMOSTATS SHALL HAVE HEATING MODE MAXIMUM SETTING OF 75 F,AND O BAR 70 CFM/LF 0.1035F/3.5' TITUS CT-480 � COOLING MODE MINIMUM SETTING OF 70 F. THE THERMOSTAT SHALL BE ARRANGED 150 CFM/LF 0.194SF/6" -- TITUS CT-480 OPERATING WEIGHT,LBS. 420 335 420 335 420 480 0 .4 TO PREVENT THE SIMULTANEOUS OPERATION OF HEATING AND COOLING. a UNIT DIMENSIONS H X W X D (IN) 54 X 35 % 38 54 X 35 X 38 54 X 35 X 38 54 X 35 X 38 54 X 35 X 38 54 X 35 X 38 5. ELECTRICAL CONTROLS AND POWER WIRING: UNDER ELECTRICAL CONTRACT. REF.PIPES SIZE; GAS I LIQ. 7/8 1 3/8 3/4 13/8 7/8 1 3/8 3/4 13/8 7/8 1 3/8 7/8 1 3/8 6. EQUIPMENT SPECIFIED BY MANUFACTURER'S NUMBER SHALL INCLUDE ALL REF.TYPE; CHARGE (lb-oz) R-41OA; 15-7 R-41OA; (9-13) R-41OA; 15-7 R-41OA; (9-13) R-41OA; 15-7 R-410A• 13-15 ACCESSORIES,CONTROLS,ETC.,USTED IN THE CATALOG AS STANDARD WITH THE 1 SEE DETAIL SHEET(S)FOR ADDITIONAL INFORMATION EQUIPMENT. OPTIONAL OR ADDITIONAL ACCESSORIES SHALL BE FURNISHED AS r SPECIFIED. 2 PROVIDE ALL UNITS WITH OPPOSED BLADE DAMPERS NOTES: w 7. MATERIALS: 3 DIFFUSER RUNOUT SIZE SHALL BE DIFFUSER NECK SIZE,UNLESS OTHERWISE NOTED 1. ALL AIR HANDLER UNITS SHALL BE PROVIDED WITH FACTORY INSTALLED CIRCUIT BREAKER. A. REFRIGERANT PIPING: SHALL BE TYPE L SOFT DRAWN,COPPER TUBING, ON PLANS 2. ALL THERMOSTATS/HUMIDISTAT SHALL BE PROGRAMABLE TYPE. DEHYDRATED FOR REFRIGERANT USE. SIZED AS SHOWN ON DRAWINGS OR AS 4 ALL SUPPLY AIR DIFFUSER AIR THROW PATTERNS ARE 4-WAY UNLESS OTHERWISE 3. ALL AIR HANDLER UNITS SHALL BE PROVIDED WITH INTEGRATED WHOLE HOUSE AIR CLEANER AND UV-LIGHT PER AIR CONDITIONING EQUIPMENT MANUFACTURER'S RECOMMENDATIONS. INDICATED ON MECHANICAL PLANS 4. STANDARD LINE LENGTHS-80'. STANDARD LIFT-25', SUCTION & LIQUID LINE. B. INSULATION: REFRIGERANT SUCTION PIPING SHALL BE INSULATED WITH 5 PROVIDE SURFACE MOUNT HARDWARE IN ALL INACCESSABLE CEIUNG SYSTEMS 1/2°THICK FOAMED PLASTIC INSULATION,FIRE RETARDANT TYPE. INSULATION SHALL BE INSTALLED IN PIPING BEFORE ASSEMBLY. NO SPLIT 6 PROVIDE LAY-IN MOUNT HARDWARE IN ALL SUSPENDED CEILING SYSTEMS INSULATION WILL BE ACCEPTABLE. SEAL JOINTS WITH MANUFACTURER'S 7 PROVIDE FULL LENGTH PLENUM FOR SIDEWALL AND LINEAR SLOTS APPROVED ADHESIVE AND GREY TAPE. rn C. DUCTWORK: B REFER TO ARCHITECTURAL REFLECTED CEILING PLAN FOR LOCATIONS OF DIFFUSERS ll 1 A. ALL HVAC DUCT WORK SHALL BE FIBERGLASS DUCT BOARD,FABRICATED 9 PROVIDE SELECTION BASED ON A MAXIMUM RADIATED NOISE DF NC-22 W AND INSTALLED AS PER LATEST EDITION OF SMACNA'FIBROUS GLASS 10,FURNISH AND INSTALL APPROPIATE HARDWARE TO CONNECT FLEX WITH DIFFUSER NECK DUCT MANUAL 1-1/2'THICK(R-6.0)IN UNCOND.SPACE ABOVE AND 1'THICK(R-4.2)IN COND.SPACE ABOVE.ALL DUCT WORK TO BE WITH ANTI MICROBIAL COATING. B. ALL EXHAUST DUCTWORK SHALL BE GALVANIZED SHEET METAL DUCT NOT LIGHTER THAN 26 GAGE. FAN SCHEDULE C. ALL DUCT DIMENSIONS ARE CLEAR INSIDE DIMENSIONS. UNIT DESIGNATION EF-1 EF-2 P D. FLEXIBLE INSULATED DUCTWORK WITH 1 1/2'FIBERGLASS MASTER ?-1 INSULATION WITH FRK VAPOR BARRIER,CLASS I AIR DUCT,U.L. AREA SERVED BATHROOM BATHROOM R-6.0 MIN. OPERATING WEIGHT,LBS 12 1s O0 E-; w E. DRYER DUCTWORK: 26 GA.MIN.GALVINIZED STEEL,HAVING A HVAC SYMBOL LEGEND HVAC DESIGN REQUIRES: YES NO SMOOTH INTERIOR SURFACE WITH JOINTS RUNNING IN THE DIRECTION CEIUNG OF AIRFLOW AND WITHOUT SHEET METAL SCREWS OR OTHER FASTNERS LOCATION CEIUNG SPACE U +u IN THE AIR STREAM.MAXIMUM LENGTH SHALL NOT EXCEED 25 FEET. SYMBOL DESCRIPTION WALL CAPS SHALL BE PROVIDED WITH BACKDRAFT DAMPER. REMOTE DUCT SMOKE DETECTOR - x WCa CO FAN TYPE CLG.BLOWER INLINE FAN 8. PROVIDE METAL ROUND FITTINGS WITH SCOOP AT ALL FLEXIBLE DUCT CONNECTION TOTAL AIR,CFM 50 70 SUPPLY DUCT � �• TO SUPPLY DUCT. FIRE DAMPER(S) - x DRIVE TYPE DIRECT DIRECT RETURN/EXHAUST DUCT W GO 9. TEST AND BALANCE: AN INDEPENDENT CONTRACTOR SHALL TEST AND BALANCE ALL x FAN WHEEL TYPE CENTRIFUGAL CENTRIFUGAL �Ny7�rr��Irrl1yy FLEXIBLE DUCT SMOKE DAMPER(S) - }( to E- VENTILATION AND AIR CONDITIONING SYSTEMS. SUBMIT FOUR COPIES OF TEST AND µWµ�V.µyt BALANCE REPORT TO OWNER FOR APPROVAL. FAN TIP SPEED,FPM MAX. --- --- FIRE RATED ENCLOSURE - W CO O 10. CONTROLS: AIR CONDITIONING UNITS SHALL BE STARTED AND STOPPED THRU FAN SPEED,RPM --- 950 ELBOW W/TURNING VALVES X Z 00 0 INDIVIDUAL THERMOSTAT. INDIVIDUAL THERMOSTATS SHALL START/STOP SUPPLY LL TOTAL STATIC REF, S PRESSURE,IN OF W.C. 0.10" 0.375' FIRE RATED ROOF/FLOOR _ FANS AND ACTIVATE COOUNG/HEATING SYSTEMS AS SELECTED. S&L REFRIGERANT SUCTION CEILING ASSEMBLY X FAN MOTOR(AMPS) 0.6 0.62 & LIQUID LINES 11. MECHANICAL PLANS IN GENERAL,ARE DIAGRAMMATIC IN NATURE,AND ARE TO BE READ FAN MOTOR STARTER TYPE WALL S WALL SWITCH FIRE STOPPING IN CONJUCTION WITH ARCH.PLUMBING,ELECTRICAL AND STRUCTURAL PLANS AND SHALL EF WITCH CEILING EXHAUST FAN - X BE CONSIDERED AS ONE SET OF DOCUMENTS.DUCT AND PIPING OFFSETS BENDS STARTER FURNISHED BY MC MC AND TRANSITIONS WILL BE REWIRED TO PROVIDE AND INSTALL A COMPUTE FUNCTIONAL ELECTRICAL SERVICE 120-I-60 120-1-60 EXHAUST REGISTER SMOKE CONTROL _ x SYSTEM AND SHALL BE PROVIDED BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE OPMER. UNIT DIMENSIONS W%LXH(IN) 14 K 70 X 9 14 X 11 X 11 12. CONTRACTOR SHALL VERIFY JOB CONDITIONS PRIOR TO ORDERING,FABRICATION OR SONES 1.0 1.3 OT COOLING THERMOSTAT INSTALLATION OF MATERIALS OR EQUIPMENT.NOTIFY ARCHITECT/ENGINEER OF ANY CONFLICTS BEFORE FABRICATION. DESIGN MANUFACTURER NUTONE CREENHECK K: AIR DEVICE TYPE a a a a MODEL NUMBER QT-50 CSP-A110 A X B O # CFM # AXB: NECK SIZE SERVICE SWITCH YES YES SMOKE DETECTOR (U.L APPROVED) NO NO SA SUPPLY AIR FIRE DAMPER --- --- RA RETURN AIR w CONSTRUCTION ALUM/PLASTIC ALUM/STEEL CU CONDENSING UNIT W N BACKDRAFT DAMPER YES YES CFM CUBIC FEET PER MINUTE w BIRDSCREEN NO O NO AHU AIR HANDLING UNIT •� a SOLID STATE SPEED CONTROL NO NO W THERMOSTAT CONTROL NO NO a a a a FACTORY FABRICATED CURB NO NO FILTER AND FILTER FRAME NO NO 11 t2 Lb 0 ¢ o0 O N O S U aJ all � O -0 .,� -c7 U G1. JOB# 098403 sheet no. Amarilis Rodriguez,PF License Nunhar 60236 MECHANICAL SCHEDULE ®engineering inc TTAA AA Gahle.InremedoneI Rene \/ 3 2955 Le Jeune Road,Suite 902 E.,a;e,,;,o a-,: Signature M �J SCALE:N.T.S Care)Gahlas,P.M.33134 nw a, >esemi Phone'3054449809 >a��n >r..c,nma, On. F.x '3054449827 www..rpe�ng.com 3 OF 3