Loading...
6835 SW 67 ST EB-09-019-072 N O v ­4 K VV _�t O I� O O m SECURE WIRE � m � a STRUCTURE OF FLOOR ABOVE SCREWS FASTENER ELBOW 4-) L co � AHU CONNECTION n�1`� TRANSITION AS REQUIRED- SU AIR TO S/A PLENUM VJ p CT PER SMACNA & DECK. O -k=) O ' CEILING F.G.PAG#2.14"DETAIL". WOOD JOTS CORNER ANG ,r-I :••. #10"X1 1/4-SHEET DUCT HANGER WIRE �(----II y,.•., METAL SCREWS 12" TURNING VAN r1 � MAX.O.C.MIN.2 12 GAUGE (MIN.-) 10"4 MAX. f PER SIDE. f UNIT WALL F/C UNIT 4" MIN. MECHANICAL m "'"• ALL SHEET METAL CHANNEL FASTENING AT (� 0 i•,,,, AROUN DUCT REFRIGERANT PIPES CONNECTION TO SUSPENDED CEILING FROM COND. UNIT AHU. (SEE ARCH. DRAWINGS) DRAIN DISCONNECTED SWITCH m 0 NEOPRENE PADS FAN SECTION DUCT HANGER DETAIL "'� N.T.S. CHANNEL STRAP & SADDLE HANG ALL DUCT PER SMACNA STANDARDS �•>� METAL SHELVE COIL SECTION TYPICAL OF 2 _ _ AUX.FLOAT HANGING GALVANIZED AUXILIARY DRAIN SWITCH. FLOAT SWITCH SHALL PAN WITH FLOAT SWITCH STOP FAN COIL (WATER LEVEL DETECTION UNIT IF HVAC DUCT DETAILS DEVICE)WIRED TO SHUT INDICATED. DOWN AHU. NOT TO SCALE D PAN SHALL BE MIN.15" -1 INTEGRATED DEEP AND BE AT LEAST 3" NOTE: NO COMBUSTIBLES ALLO WHOLE HOUSE LARGER THAN THE UNIT ON AIR CLEANER p m°m w q°m ro ALL DIRECTIONS. IN A/C CLOSET. p y'o m U *GALV. N DUCT w FLOOR L� I RETURN AIR CLINCH EDGE FLITTER DAMPER ro y pa .�; b... PLENUM �m+,q°a q m•d o v u+m+ o� o mb'•OC a.Cau NOTE. .. .. .. .. BRANCH DUC :4 a o y b y p m 3 0 A m d 1. PROVIDE MINIMUM 4"SERVICE/MAINTENANCE AREA AROUND AIR DIRECTION OF m mm m„q 0 v HANDLING UNIT. \AIRFLOW "m a aE 0 2.PROVIDE FLOAT SWITCH IN DRAINPAN WIRED TO SHUT DOWN AC ro ao A m°o ACER REQ'D ON INSULATED DUCT m o '� UNIT IN CASE OF CONDENSATE STOPPAGE.AS PER FBC 307.2.3. CREW E+ ° EEL ROD a,rj m FAN COIL UNIT MOUNTING DETAIL N.T.S. TYPICAL DUCT TAP—OFF H N.T.S. PERFORATED CAP O SUPPORT FROM CLEAN OUT 1 1/2" X 26 GA. GALV. UNDERSIDE OF o �' DRAIN PAN STEEL L HANGER STRAP STRUCTURE. 18"MIN SUPPORT STRAP(SUPPORT FROM PITCH DOWN STRUCTURE) r—, w ' TOWARD DRAIN AIR DUCT(SEE PLAN VIEW) CLEAN OUT LOW FRICTION LOSS SUPLY OR RETURN AIR PLENUM BRANCH TAKE-OFF FITTING METAL ROUND FITTING SUPPORT BRACE(16"ON CENTER) 2"MIN QUADRANT OPERATOR TO B OUTSIDE INSULATION PROVIDE INSULATION GUARD DRAIN UNE SHALL BE AT LEAST THE WHERE NECESSARY SAME SIZE AS THE NIPPLE ON THE AIR FLOW DRAIN PAN SEAL JOINT W/ DUCT SEALER AND 6•MAX. TAPE DUCT r 3'MIN CLAMP w SPIN-IN TAP TYPICAL CONDENSATE DRAIN TRAP AIR FLOW CEILING N.T.S. INSULATE TOP INSULATED FLEX. DUCT __ CT-480 OF DIFFUSER. BAND OF SAME SIZE AS HANGER STRAP NOTES: 1.REFER TO ARCH.FOR FRAMING (3)#14 SHEET METAL SEAL JOINT WITH DUCT 2.SIDE DISCHARGE UNEAR BAR DIFFUSER SCREWS TO C.U. SEALER AND TAPE MOUNTING PROCEDURE IS THE SAME BUT NTH AIR OUTLET FACING VERTICAL FACE A/C UNITHOUSING 1/2"HILTI SLEEVE OF SORT. f�, C] ANCHORS(3)PER SIDE W 2" X 2" X 3/ " DIFFUSER W/ OPPOSED SECTION LINEAR BAR DIFFUSER c' INSULATED PAD BLADE DAMPER- N.T.S. W �° Q _ 1-1/4"X 12",18 GAUGE GALVN.METAL ADAPTOR ROUND TO SQUARE STRAP.ONE ON EVERY IF REQUIRE CORNER OF W P Og.:: 08:. °b:. CONDENSER. a t=1 u E FLEXIBLE DUCT CONNECTION DETAIL z �AU)) 1/8"SS WRE MOUNTING DETAIL ®BASE W/TURNBUCKLES PROVIDE ANTI THEFT(1) TOILET EXHAUST DUCT ANCHORED TO SLAB W 18 LOS.BOLT WITHIN UNIT CASING N.T.S. (S G (SHEETMETAL/THERMOFlN) GAUGE TFK SCREWS TO SLAB. TYPICAL ROOF CAP c POWER AND CONTROL VIBRATION HANGER SPRING TYPE COND SING CONNECTIONS W/NEOPRENE ISOLATOR n UNIT 6" MIN. GRADE RODS THREADED 6" MIN, `4" MIN. UOIST VIBRATION 3/8"ALL ISOLATOR a a a a CONCRETE BASE THREAD W/ 6" X 6"- % .�`�� LIQUID LINE WITH 12'DIAMETER o VIBRATION 10/10 W.W.F. ii n OUT INSULATION CONCRETE ° ISOLATOR PERFORATED AL O 2" X 2" X 3/4" 1�;;`,` DRAINAGE OR CLAY DUCT PIPE WITHOUT COVER ° INSULATED PAD `�:� DUCT CEILING 'r:' 4'16 SCH. 40 FILLED WITH 3/4" HUNG SUCTION LINE WITH 3/ P.V.C. PIPE CRUSHED ROCK 2" INLINE CE LING 1 •O 6" M CONDENSATE FA GRILLE � NOTE: CONDENSER SHALL BE °° ° DRAIN LINE 2" X 1•• '~j ARMAFLER INSULATION INSTALLED ABOVE FLOOD LEVEL 24" FROM BUILDING UNISTRUT. AND VAPOR BARRIER A/C CLOSET. o°°° SEE PLAN NOTES, 2. PROVIDE L BEAL WALL DAMPER aaaa ° ° CEILING BACKDRAFT— 3.-PROVIDE INTERNAL ISOLATION AND SOUND INSULATION �E: CONCRETE CREWS SHALL BE RATED a.-SUPPORT FAN FROM STRUCTURE FOR 500 LBS. MIN.PULL-OUT CAPACITY. DAMPER O Q CONDENSING UNIT MOUNTING DETAIL DRY WELL DETAIL TOILET INLINE EXHAUST DETAIL CABINET EXHAUST FAN DETAIL 1 N.T.S. N.T.S. N.T.S. a N.T.S. 0 ^C N U "C .m T7 U p JOB# 09-040.3 rp3E3 sheet no. no Amenlia Rodriguez,RE U—s.Numb.,60238 MECHANICAL DETAILS ©engineering inc 0. e Gables Intemedanel Raze / - 2 2655 L.June Road,Suit.902 amp,Vuw,; Signature M fF��1 Corsi Gables,Florida 33134 SCALE:N.T.S Phone>3054449809 >au,ro.a >r..rmm., Dam Fax >3054"9827 vnyy,erpe-eng.com 2 OF 3