13-749-129
DRAINAGE/ LIGHTING/ VENTILATION INFORMATION SHOWN FOR REFERENCE ONLY. SEE MEP DRAWING FOR COORDINATION 40'-0" EXISTING 10'-0" HIGH 16'-9" 12'-11" B' 6" a" 4'-4" 8" 6-0" CHAIN LINK FENCE -x x x x x x x x x x x x x 8'-6" x 4'-6" x 6" CONCRETE SLAB REINFORCED WITH *3 @ 12" EACH WAY. 3" CLEAR BOTTOM (SLOPES NEW 6'-0" HIGH -�-X X TOWARD GRAVEL AREA) CHAIN LINK FENCE NEW 6'-0" HIGH 0 ID# DESCRIPTION 64' x 2'-6" x 6" CONCRETE SLAB REINFORCED WITH GPM PIPE SIZE DA MAIN DRAIN LINE TO POOL COLLECTOR TANK 3 FPS 322.00 a" © GUTTER LINE TO POOL COLLECTOR TANK 3 FPS 322.00 CHAIN LINK FENCE © EQUALIZER LINE TO POOL COLLECTOR TANK C0 UJ c' Z1320MPCP #3 @ 12" EACH WAY, 3" CLEAR BOTTOM (SLOPES 2" 0 X 6 FPS 322.00 6" �E POOL FILTER PUMP RETURN LINE 10 FPS 322.00 TO MATCH EXISTING E1 XTOWARD 10 FPS GRAVEL AREA) 3" E2 RETURN LINE TO FLOOR RETURN FITTINGS 10 FPS 167.00 3„ 0 MAKE UP WATER LINE (MDWASA), REFER TO CIVIL DRAWINGS FOR CONTINUATION OF PIPE Z 1" Q POOL BACKWASH LINE 10 FPS 4 4" WASTE LINE TO STORM DRAINAGE SYSTEM- VIA AIR GAP (REFER TO CIVIL DRAWINGS FOR CONTINUATION OF PIPE) 3 FPS 337.50 8" ❑I POOL DRAIN LINE 10 FPS 100.00 2" �J WORK LIGHT TO EMIT 30 FC OF ILLUMINATION AT 3 FPS 100.00 4„ x x x 100.00 2-112" Q FROM GAS HEATER 8 FPS 100.00 2-112" FLOOR LEVEL. SEE ELECTRICAL DRAWINGS . O O� O o W CO POOL EQUIPMENT Z PIPING PLAN GAS X ' POOL EQUIPMENT YARD ,. ELECTRICAL . / ROOM X INTERACTIVE WATER FEATURE 2' 6 „ PRE-PACKAGE WATER TREATMENT SYSTEM . low (2) 3'-011 x 61_8 ' FULLY LOUVERED:..... DOOR \ GRAVEL DRAINAGE AREA AROUND o \ POOL EQUIPMENT GRAUEL'DRAINAGI= CONCRETE'PADS ., ROOM N _ AREA ...b. ti •,� X VAK PAK 1,500 GALS INTERACTIVE WATER FEATURE s I SURGE TANK R c f SLOPE FLOOR TO 17 zn bo RECREATIONAL BOOL COLLECTOR TANK FLOOR DRAIN logX MINIMUM HEADROOM SHALL 6' N \ BE T-0" FLOOR TO CEILING `'. NEW 6'-0" HIGH CHAIN LINK FENC€ N �. x .. x x x x:, wb x x fix, x`. �( x �x'4. x a� o 4" HOSE BIBB VAC WITH I 4'-0" WIDE x 6'-0" HIGH CHAIN LINK BREAKER ENCLOSURE WITH SELF-CLOSING & 5'-8" ON POOL EQUIPMENT YARD PLAN SCALE: 1/4" = V-0" N P I T-6" 4'-6" V-6" 1, 51-8" 1'-0" 5'_0" 8'-6" x 4'-6" x 6" CONCRETE SLAB REINFORCED WITH #3 @ 12" EACH WAY. 3" CLEAR BOTTOM, SLOPES TOWARD GRAVEL AREA 4" WASTE LINE TO STORM DRAINAGE SYSTEM- VIA AIR GAP (REFER TO CIVIL DRAWINGS FOR CONTINUATION OF PIPE) 8" WASTE LINE TO STORM DRAINAGE SYSTEM (WITH P -TRAP)- VIA AIR GAP, (REFER TO CIVIL DRAWINGS FOR CONTINUATION OF PIPE) X INTERACTIVE WATER FEATURE PRE-PACKAGE WATER TREATMENT SYSTEM (SEE DETAILS ON SP -2.05) X X ALL EQUIPMENT SHALL RE GFCI PROTECTED SELF -LATCHING GATE WITH LOCKING DEVICE 10'-0" I x x x. I x x X z x x, x,' >c _L_ 1„ -J I RECREATIONAL POOL -- ---1� -_ - -------•M--12 ------------ -a �PULSAR E \ I STENNERI45M5ACID FEEDER+ ❑2 0 1❑ � 0 � © I 1-1/2" MAKE UP WATER LINE (MDWASA), REFER TO CIVIL © '�, BECSYSTEM 5 DRAWINGS FOR CONTINUATION OF PIPE ,~`�---- DUPLEXOUTLET tPOOL EQUIPMENT PIPING PLAN SCALE: 1/4 = 1'-0" PROVIDE WALL VENTS ON THIS WALL (EXHAUST FAN IS OPTIONAL) 0 OD C 30 F.C. AT FLOOR LEVEL REQ'D. 4" POOL BACKWASH- DRAIN 4110 LINE �-F _3" AIR GAP V-12" COLLAR (BY POOL CONTRACTOR) m FINISHED FLOOR @ POOL EQUIPMENT ROOM ' •, ! HUB TO BE INSTALLED BY GENERAL CONTRACTOR B" WASTE LINE TO STORM DRAINAGE SYSTEM (REFER TO CIVIL DRAWINGS FOR CONTINUATION OF PIPE) POOL BACKWASH TO STORM DRAINAGE SYSTEM DETAIL SCALE: N.T.S. --2" POOL DRAIN LINE J-_3" AIR GAP z -�- 12" COLLAR (BY POOL CONTRACTOR) N CONCRETE SLAB ' -- HUB TO BE INSTALLED BY GENERAL CONTRACTOR 4" WASTE LINE TO STORM DRAINAGE SYSTEM- VIA AIR GAP (REFER TO CIVIL DRAWINGS FOR CONTINUATION OF PIPE) POOL DRAIN LINE TO STORM DRAINAGE SYSTEM DETAIL SCALE: N.T.S. •O-fO ••bl r C Offs• Or + r u V V W v • • U • U y y • y f r • • • r y u r V• Vv G fOr •r•• r, • • • a *we* . t EQUIPMENT ROOM REQUIREMENTS: •v• yv • O f, r e v 1, THE FLOOR IN THE ROOM SHALL BE CONSTRUCTED OF CONCRETE HAVING A • y SMOOTHLIKE NON -SLIP SURFACE FINISH, 2. THE FLOOR SHALL BE POSITIVELY DRAINED TOA FLOOR DRAIN. :..a' • r • r . . 3. A j INCH HOSE BIBB WITH VACUUM BREAKER SHALL BE LOCATED INSIbE THE ROOM, 4. THE OVERHEAD LIGHT SHALL EMIT AT LEAST 30 FOOT CANDLES OF ILLUMINATION AT THE FLOOR LEVEL. 5. CLEARANCES TO PUMPS AND FILTERS FROM WALLS SHALL BE AS SPECIFIED BY THE MANUFACTURER. FILTER & PIPING REQUIREMENTS: 6. TAG ALLVALVES, LABELALL PIPEAND POST OPERATING INSTRUCTION INSIDE THE ROOM. 7. ALL FACE PIPING SHALL BE PVC SCHEDULE 40 NSF -PW. ALL JOINTS SHALL BE NON -THREADED SOLVENT WELD TYPE. 8. GATE VALVES SHALL NOT BE USED AS A MEANS FOR CONTROLLING THE FLOW OF WATER. ALL PROPORTIONAL FLOW TYPE VALVES ARE INDICATED ON THE DRAWING. 9. ELECTRICALLY OPERATED CHEMICAL FEEDERS SHALL BE INTERLOCKED WITH THE FILTER PUMP MOTOR. 10. THE CHEMICAL SOLUTION TANK SHALL BE LABELED ACCORDING TO THE SOLUTION OF WHICH IT CONTAINS, 11, ALL VALVES 3" & SMALLER SHALL BE SPEARS TRUE UNION VALVES OR EQUAL. 12. ALL VALVES 4" & LARGER SHALL BE ASAHI EPDM BUTTERFLY VALVES OR EQUAL. 13. SUPPORT ALL PIPING ON FLOOR OF EQUIPMENT ROOM WITH UNISTRUT FRAME OR EQUAL. 14. SECURE ALL CHEMICAL FEEDER TUBING TO WALL. NO LOOSE TUBING. NOTES: 15. ALL EXPOSED PVC PIPE SHALL BE TREATED AGAINST U, V. LIGHT. 16. ALL POOL EQUIPMENT INDICATED IS APPROVED BY MANUFACTURER FOR OUTDOOR USE. 17. ALL VALVES ARE PROPORTIONAL FLOW TYPE VALVES (BALL OR WAFER) GATE VALVES ARE NOT ACCEPTABLE. 18. INTERNAL HEATER PARTS ARE NON-TOXIC TO BATHERS WHEN USED IN CONJUNCTION WITH POTABLE WATER, RECREATIONAL POOL LEGEND 0 ID# DESCRIPTION VELOCITY GPM PIPE SIZE DA MAIN DRAIN LINE TO POOL COLLECTOR TANK 3 FPS 322.00 a" © GUTTER LINE TO POOL COLLECTOR TANK 3 FPS 322.00 8" © EQUALIZER LINE TO POOL COLLECTOR TANK C0 UJ c' Z1320MPCP PROJECT NUMBER 2" 0 POOL FILTER PUMP SUCTION LINE 6 FPS 322.00 6" �E POOL FILTER PUMP RETURN LINE 10 FPS 322.00 4" E1 RETURN LINE TO WALL RETURN FITTINGS 10 FPS 155.00 3" E2 RETURN LINE TO FLOOR RETURN FITTINGS 10 FPS 167.00 3„ 0 MAKE UP WATER LINE (MDWASA), REFER TO CIVIL DRAWINGS FOR CONTINUATION OF PIPE Z 1" Q POOL BACKWASH LINE 10 FPS 337.50 4" WASTE LINE TO STORM DRAINAGE SYSTEM- VIA AIR GAP (REFER TO CIVIL DRAWINGS FOR CONTINUATION OF PIPE) 3 FPS 337.50 8" ❑I POOL DRAIN LINE 10 FPS 100.00 2" �J WASTE LINE TO STORM DRAINAGE SYSTEM- VIA AIR GAP (REFER TO CIVIL DRAWINGS FOR CONTINUATION OF PIPE) 3 FPS 100.00 4„ �, TO GAS HEATER a FPS 100.00 2-112" Q FROM GAS HEATER 8 FPS 100.00 2-112" D ESIGN AND CONSTRUCTION, INC. 3990 North Powerline Road Ft. Lauderdale, FL 33309 Voice: 954.566.3885 Fax: 954.566.3335 u5 0 Z Z w� o� LL � VJr� J N g O F- w Z d w u Z O u3 n O w 0m_ ` � J �0 �m z� �E o Z _© o- oCk CLU w� w D ww o O z _Fn w me 0: O t CD W N � � c :: Lu _� o Z 01 LLE Z w `- CD 0 n - Z wo o" Wz> W' '^ (A wx U O W U w� ~ D} ww Q a< i D > Z s. J C � 0 w Q wm m .40 o �< w> �w _k OF OFE§A NBOApA, P.E. • KGFESIONAL RE55IL 6N I 3� O a ujw oFmM Q 0 cc z L i4 C") 7 -- CL Lu CL Lu a 04 0 U Ln ..= '° T E Q Z rn Z..' `n - f T 'i7 SHEET NUMBER SP -3.01 0 LL 4:::L 0 '40-, cl: Q a LL 0 z O U z cD C/� C0 UJ c' Z1320MPCP PROJECT NUMBER I- o w uj FILE No. w m DRAWN M.F. ° REVIEWED: J.W. C CHECKED J.W. Lu Z DATE 07-02-2013 C) J TISSUE/REVISIONS C..� w J w Z co �, Z c� C-3 rr O O� O SHEET TITLE W CO POOL EQUIPMENT Z PIPING PLAN 'i7 SHEET NUMBER SP -3.01