13-749-113—1.3b61 SO. --
3/4" NOSE
CONNECTION,
0.4888.
m
0
z
n
I/4" I.P.S.
w
DRAIN PORT -,
Q
F- 3/4" OR I" FEMALE
LIPS,
WALL HYDRANT AT POOL DECK ZURN MODEL Z1360 -VB.
BOX HYDRANT -NON FREEZE - FLUSHF WITH SURFACE.
TYPICAL ENCASED GROUND HYDRANT DETAIL
N.T.S.
METER
VAULT
PLAN VIEW
REDUCED RE
BACKFLOW
PREVENTION i
ASSEMBLY
TEST
COCK
I
PRESSURE
AI PREVENTION
ASSEMBLY
TEST COCK
BALL VALVE (TYPJ
MIN. - 30" MAX.
FINISHED
GRADE
METER
VAULT -
I CONC, SLAB WITH
x4 t 12" E,W
ELEVATION VIEW
RAINCAP: 12
GALV. METAL
DOUBLE WALL INSULATED FLUE.
SEE FLOOR PLAN FOR SIZE, REFER
TO SPECIFICATIONS FOR MATERIAL—
DOUBLE WALL INSULATED
FLUE. SEE FLOOR PLAN
FOR SIZE. REFER TO
SPECIFICATIONS FOR
MATERIAL
2" MIN.
SUPPORTS: 12GA.
GALV. METAL
SOLDER JOINT
RAIN HOOD
(GALV. METAL)
FOR FLASHING DETAIL
REFER TO ARCH
DOCUMENTS
COVER SECURED
WITH SCREWS
THREADED C,O. PLUG
--FIN. GRADE
4 X 6" DIA. CONCRETE
PAD FLUSH W/FIN. GRADE
0
FLUE THEU ROOF DETAIL
cn
N.T.S.
NOTES:
1. THE ASSEMBLY SHALL BE INSTALLED WITH MINIMUM HORIZONTAL
CLEARANCES OF 30 INCHES FREE FROM OBSTRUCTIONS IN ALL DIRECTIONS.
2. GUARD POSTS SHALL: BE INSTALLED IF THE ASSEMBLY IS EXPOSED TO
POSSIBLE DAMAGE FROM VEHICULAR TRAFFIC, AS DETERMINED BY THE
DEPARTMENT.
3. THE ASSEMBLY SHALL BE INSTALLED IN AN ACCESSIBLE LOCATION,
APPROVED BY THE DEPARTMENT.
4. ADJUSTABLE PIPE SADDLE SUPPORT (GRINNELL FIG. 264, OR EQUAL) SIZED
TO FIT CURVATURE OF DOUBLE DETECTOR CHECK VALVE ASSEMBLY, WITH
GALVANIZED STEEL PIPE AND FLOOR FLANGE. ATTACH FLOOR FLANGE TO
CONCRETE SLAB WITH GALVANIZED EXPANSION BOLTS.
5. THE DEPARTMENT SHALL HAVE UNRESTRICTED AND CONTINUOUS ACCESS
TO THE BACKFLOW PREVENTION ASSEMBLY.
6. PIPING 2" AND SMALLER SHALL BE SCHEDULE 40 BRASS OR TYPE K COPPER
PIPE WITH FITTINGS. PIPING 21/2" AND LARGER SHALL BE DUCTILE IRON PIPE
WITH FLANGED FITTINGS. ALL PIPING SHALL BE IN ACCORDANCE WITH
WASD CONSTRUCTION SPECIFICATIONS FOR DONATION WATER MAINS, PVC
PIPING IS NOT ACCEPTED BY WASD.
7. ALL OUTLETS SHALL BE PLUGGED WITH BRASS PLUGS.
8. ALL ABOVE GROUND PIPING AND EQUIPMENT, EXCEPT FOR BRASS AND
STAINLESS STEEL PORTIONS, SHALL BE FINISHED WITH BLUE ENAMEL PAINT
(KOP-COAT 0508 LEAD-FREE) IN ACCORDANCE WITH DEPARTMENT
STANDARDS.
WS 4.18
REDUCED PRESSURE ZONE BACKFLOW PREVENTER
N.T'5 WATER SERVICE 3/4" THRU 2"
METAL DOWNSPOUT
TRANSITION FROM
SQUARE SHEET
METAL TO
ROUND PIPE
6"MIN. OR 5'-0"IF
EXPOSED TO TRAFFIC.
CAULK
C.I. HUB
GRADE
TO STORM
DRAIN SYSTEM �!
DOWNSPOUT TRANSITION DETAIL
N.T.S.
SEE FLOC
FOR CON'
AND PIPE
SLIP JOINT
F
.— 11 11— n -1 r ��l i n n
EXTERIOR TYPE FLOOR
TYPICAL CLEANOUT DETAIL
N.T.S.
LOCATION MARKER
a
- -I 2'-0„
REMOVABLE FLANGED
1/4" STEEL COVER
-\iii--1=1 Iiii _iii ii .o
III I
DRAIN PIPE
�-
2'-0"0 PERFORATED
CORRUGATED STEEL
PIPE OR EQUAL
FILL W/COARSE GRAVEL
AS SHOWN.
6"
I/4" STEEL FLANGE
FRENCH DRAIN (DRYWELL) DETAIL
N.T.S.
PROJ. No. 23026 • • •A 924
•• ••• • •
LOUIS J. AGUIRRE & ASSOCIATES P.A.
CONSULTING ENGINEERS, •;
9150 SOUTH DADFLAND BLVD. ; SUITE 9M
MIAMI, FLORIDA ' 33aD
TELEPHONE: (305) 670-0141
FAX: (305) 670-0144 ,•••• •y�.•
w.......... ..... .._
• V • •
www.ljaapa.com
Yv�rY ��... . "•' . RECREATIONAL
D ESIGN AND
CONSTRUCTION, INC.
3990 North Powerline Road
Ft. Lauderdale, FL 33309
Voice: 954.566.3385
FACE OF WALL Fix: 354.566.3335
STAINLESS STEEL COVER Uw
/
SCREWED TO THREADED
s
C.O. PLUG. CK • ;
WALL
2' -TO
2"J
I/4" STEEL COVER
3/16
1 In^ I ICT 1 I/11 C
GAS FIRED WATER HEATER IDLTAIL
N.T.S.
SCK
SHEET NUMBER
........ ....... .... .... ....
..
P7.01