13-749-113—1.3b61 SO. -- 3/4" NOSE CONNECTION, 0.4888. m 0 z n I/4" I.P.S. w DRAIN PORT -, Q F- 3/4" OR I" FEMALE LIPS, WALL HYDRANT AT POOL DECK ZURN MODEL Z1360 -VB. BOX HYDRANT -NON FREEZE - FLUSHF WITH SURFACE. TYPICAL ENCASED GROUND HYDRANT DETAIL N.T.S. METER VAULT PLAN VIEW REDUCED RE BACKFLOW PREVENTION i ASSEMBLY TEST COCK I PRESSURE AI PREVENTION ASSEMBLY TEST COCK BALL VALVE (TYPJ MIN. - 30" MAX. FINISHED GRADE METER VAULT - I CONC, SLAB WITH x4 t 12" E,W ELEVATION VIEW RAINCAP: 12 GALV. METAL DOUBLE WALL INSULATED FLUE. SEE FLOOR PLAN FOR SIZE, REFER TO SPECIFICATIONS FOR MATERIAL— DOUBLE WALL INSULATED FLUE. SEE FLOOR PLAN FOR SIZE. REFER TO SPECIFICATIONS FOR MATERIAL 2" MIN. SUPPORTS: 12GA. GALV. METAL SOLDER JOINT RAIN HOOD (GALV. METAL) FOR FLASHING DETAIL REFER TO ARCH DOCUMENTS COVER SECURED WITH SCREWS THREADED C,O. PLUG --FIN. GRADE 4 X 6" DIA. CONCRETE PAD FLUSH W/FIN. GRADE 0 FLUE THEU ROOF DETAIL cn N.T.S. NOTES: 1. THE ASSEMBLY SHALL BE INSTALLED WITH MINIMUM HORIZONTAL CLEARANCES OF 30 INCHES FREE FROM OBSTRUCTIONS IN ALL DIRECTIONS. 2. GUARD POSTS SHALL: BE INSTALLED IF THE ASSEMBLY IS EXPOSED TO POSSIBLE DAMAGE FROM VEHICULAR TRAFFIC, AS DETERMINED BY THE DEPARTMENT. 3. THE ASSEMBLY SHALL BE INSTALLED IN AN ACCESSIBLE LOCATION, APPROVED BY THE DEPARTMENT. 4. ADJUSTABLE PIPE SADDLE SUPPORT (GRINNELL FIG. 264, OR EQUAL) SIZED TO FIT CURVATURE OF DOUBLE DETECTOR CHECK VALVE ASSEMBLY, WITH GALVANIZED STEEL PIPE AND FLOOR FLANGE. ATTACH FLOOR FLANGE TO CONCRETE SLAB WITH GALVANIZED EXPANSION BOLTS. 5. THE DEPARTMENT SHALL HAVE UNRESTRICTED AND CONTINUOUS ACCESS TO THE BACKFLOW PREVENTION ASSEMBLY. 6. PIPING 2" AND SMALLER SHALL BE SCHEDULE 40 BRASS OR TYPE K COPPER PIPE WITH FITTINGS. PIPING 21/2" AND LARGER SHALL BE DUCTILE IRON PIPE WITH FLANGED FITTINGS. ALL PIPING SHALL BE IN ACCORDANCE WITH WASD CONSTRUCTION SPECIFICATIONS FOR DONATION WATER MAINS, PVC PIPING IS NOT ACCEPTED BY WASD. 7. ALL OUTLETS SHALL BE PLUGGED WITH BRASS PLUGS. 8. ALL ABOVE GROUND PIPING AND EQUIPMENT, EXCEPT FOR BRASS AND STAINLESS STEEL PORTIONS, SHALL BE FINISHED WITH BLUE ENAMEL PAINT (KOP-COAT 0508 LEAD-FREE) IN ACCORDANCE WITH DEPARTMENT STANDARDS. WS 4.18 REDUCED PRESSURE ZONE BACKFLOW PREVENTER N.T'5 WATER SERVICE 3/4" THRU 2" METAL DOWNSPOUT TRANSITION FROM SQUARE SHEET METAL TO ROUND PIPE 6"MIN. OR 5'-0"IF EXPOSED TO TRAFFIC. CAULK C.I. HUB GRADE TO STORM DRAIN SYSTEM �! DOWNSPOUT TRANSITION DETAIL N.T.S. SEE FLOC FOR CON' AND PIPE SLIP JOINT F .— 11 11— n -1 r ��l i n n EXTERIOR TYPE FLOOR TYPICAL CLEANOUT DETAIL N.T.S. LOCATION MARKER a - -I 2'-0„ REMOVABLE FLANGED 1/4" STEEL COVER -\iii--1=1 Iiii _iii ii .o III I DRAIN PIPE �- 2'-0"0 PERFORATED CORRUGATED STEEL PIPE OR EQUAL FILL W/COARSE GRAVEL AS SHOWN. 6" I/4" STEEL FLANGE FRENCH DRAIN (DRYWELL) DETAIL N.T.S. PROJ. No. 23026 • • •A 924 •• ••• • • LOUIS J. AGUIRRE & ASSOCIATES P.A. CONSULTING ENGINEERS, •; 9150 SOUTH DADFLAND BLVD. ; SUITE 9M MIAMI, FLORIDA ' 33aD TELEPHONE: (305) 670-0141 FAX: (305) 670-0144 ,•••• •y�.• w.......... ..... .._ • V • • www.ljaapa.com Yv�rY ��... . "•' . RECREATIONAL D ESIGN AND CONSTRUCTION, INC. 3990 North Powerline Road Ft. Lauderdale, FL 33309 Voice: 954.566.3385 FACE OF WALL Fix: 354.566.3335 STAINLESS STEEL COVER Uw / SCREWED TO THREADED s C.O. PLUG. CK • ; WALL 2' -TO 2"J I/4" STEEL COVER 3/16 1 In^ I ICT 1 I/11 C GAS FIRED WATER HEATER IDLTAIL N.T.S. SCK SHEET NUMBER ........ ....... .... .... .... .. P7.01