Loading...
13-749-10511 PLUMBING GENERAL NOTES II 1. ALL WORK PERFORMED UNDER THIS CONTRACT SHALL COMPLY WITH THE FLORIDA BUILDING CODE 2010 AND ALL APPLICABLE STATE, COUNTY AND LOCAL ORDINANCES. 2. THE CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS AND EQUIPMENT NECESSARY FOR THE COMPLETE INSTALLATION OF THE PLUMBING SYSTEMS, ALL IN ACCORDANCE WITH THESE CONSTRUCTION DOCUMENTS. 3. THE CONTRACTOR IS RESPONSIBLE FOR VISITING THE SITE OF THE WORK AND BECOMING FAMILIAR WITH THE CONDITIONS OF THE WORK PRIOR TO SUBMITTING A BID. THE CONTRACTOR IS REQUIRED TO BECOME FAMILIAR WITH ALL THE CONTRACT DOCUMENTS PERTAINING TO THE PROPOSED WORK. THE SUBMISSION OF A BID SHALL BE SUFFICIENT TO ESTABLISH THAT THE CONTRACTOR HAS INVESTIGATED THE SITE OF THE WORK AND IS SATISFIED AS TO ALL REASONABLE CONDITIONS TO BE ENCOUNTERED, THE WORK TO BE PERFORMED AND THE MATERIALS TO BE PROVIDED IN THE COMPLETION OF THE PROJECT. 4. FAILURE OF BIDDERS TO MAKE REQUIRED VISITATIONS AND/OR INVESTIGATIONS TO INFORM THEMSELVES FULLY OF EXISTING CONDITIONS, AND TO INCLUDE IN THEIR PROPOSALS A SUM SUFFICIENT TO COVER ALL POSSIBLE FIELD CONDITIONS, WILL NOT IN ANY WAY ENTITLE THEM TO ANY EXTRA CHARGES OVER AND ABOVE THEIR ORIGINAL PROPOSALS. 5. IT IS THE INTENT OF THE PLANS AND GENERAL NOTES TO PROVIDE A COMPLETE AND OPERATING INSTALLATION INCLUDING ALL NECESSARY ITEMS REQUIRED, EVEN THOUGH ITEMS ARE NOT INDICATED ON THE DRAWINGS OR IN THE NOTES. ALL WORK CONSIDERED NECESSARY FOR THE COMPLETION OF THE WORK IN PROPER MANNER NOT SHOWN ON THE PLANS OR NOTES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER IN WRITING PRIOR TO BIDS OTHERWISE WORK SHALL NOT BE ADDITIONALLY CHARGED AFTER BID IS AWARDED. 6. UPON COMPLETION, CONTRACTOR SHALL CLEAN ALL DUST AND DEBRIS IN AREAS WHERE WORK WAS CONDUCTED. 7. ALL WORK SHALL BE COORDINATED WITH ALL OTHER TRADES AT JOB SITE PRIOR TO FABRICATION AND INSTALLATION OF EQUIPMENT. 8. THE WORK THAT IS TO BE DONE UNDER THIS CONTRACT INCLUDES THE FURNISHING OF ALL LABOR, MATERIALS AND EQUIPMENT REQUIRED FOR THE COMPLETION OF THE SYSTEMS SHOWN ON DRAWINGS. 9. THE DRAWINGS ARE GENERALLY DIAGRAMMATIC. THEY DO NOT SHOW EVERY BEND, OFFSET, ELBOW OR OTHER FITTINGS WHICH MAY BE REQUIRED FOR THE INSTALLATION IN THE SPACE ALLOCATED. 10. DRAWINGS ARE NOT TO BE SCALED. UNLESS SPECIFIC DIMENSIONS ARE SHOWN, THE ARCHITECTURAL AND/OR SITE CONDITIONS SHALL GOVERN EXACT LOCATION OF PIPING AND EQUIPMENT TO BE INSTALLED. 11. ALL MATERIALS AND EQUIPMENTS SHALL BE NEW AND OF GOOD QUALITY OF RESPECTIVE KIND AND GRADE AND MUST BE FURNISHED SO AS TO PREVENT ANY DELAY IN THE PROGRESS OF THE WORK. ALL WORK THROUGHOUT SHALL BE PERFORMED IN A WORKMANLIKE MANNER BY SUFFICIENT NUMBER OF SKILLED WORKMEN. 12, FOR EXACT LOCATION OF ALL PLUMBING FIXTURES, SEE ARCHITECTURAL DRAWINGS, DO NOT ROUGH -IN ANY PLUMBING FIXTURE AND/OR EQUIPMENT WITHOUT AN APPROVED COPY OF THE CORRESPONDING SHOP DRAWINGS. 13. FURNISH AND INSTALL CONNECTIONS TO EQUIPMENT PROVIDED BY THE OWNER UNDER THIS CONTRACT, COORDINATE INSTALLATION WITH MANUFACTURER'S RECOMMENDATION. 14. PLUMBING CONTRACTOR SHALL GURANTEE ALL WORK FREE OF DEFECTS IN MATERIALS AND WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM DATE OF ACCEPTANCES. 15. CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE ALL ROUGH INS WITH EQUIPMENT AND FIXTURES MANUFACTURER BEFORE MAKING ANY INSTALLATION. 16. ALL EXPOSED TRIM SHALL BE CHROME PLATED FINISH FOR ALL WATER SUPPLY AND WASTE ASSEMBLIES. 17. CONTRACTOR SHALL PROTECT AND FIRE SEAL ALL OPENINGS AND PIPE PENETRATIONS THROUGH FIRE RATED WALLS AND CEILINGS WITH ADEQUATE FIRESTOPPING MATERIALS TO MAINTAIN THE INDICATED FIRE RATINGS OF THE ASSEMBLIES BEING PENETRATED. 18. PROVIDE CEILING / WALL ACCESS PANELS WHERE INDICATED IN THE DRAWINGS AND WHERE REQUIRED TO ACCESS PLUMBING EQUIPMENT. PANELS SHALL BE RECESSED TYPE, FIRE RATED IF IN FIRE RATED WALLS OR CEILINGS. LOCATIONS OF PANELS SHALL BE COORDINATED WITH ALL THE OTHER TRADES. WATER HAMMER ARRESTER SCHEDULE MARK *P.D.I. SIZE CONN. SIZE A A (1 - 11 F.U.) 1/2" B B (12 - 32 F.U.) 3/4" C C (33 - 60 F.U.) 1" D D (61 - 113 F.U.) 1" E E (114 - 154 F.U.) 1" F F (155 - 330 F.U.) 1" * PLUMBING AND DRAINAGE INSTITUTE STANDARD WH -201 DRAINAGE SLOPE PER FOOT SCHEDULE DIAMETER OF PIPE PITCH UP TO 2 1/2" MIN. 1/4" / FT 3" TO 6" MIN. 1/8" / FT 8" AND ABOVE MIN. 1/16" / FT 11 PLUMBING SPECIFICATIONS 11 HANGERS AND SUPPORTS A. PROVIDE ADJUSTABLE HANGERS, INSERTS, BRACKETS, ROLLS, TRAPEZE, CLAMPS AND SUPPLEMENTARY STEEL AS REQUIRED FOR PROPER SUPPORT OF PIPE LINES. B. HANGERS SHALL ALLOW FOR EXPANSION AND CONTRACTION OF PIPE LINES AND OF ADEQUATE SIZE TO PERMIT COVERING TO RUN CONTINUOUSLY THROUGH HANGERS. C. COORDINATE LOCATION OF HANGERS WITH OTHER TRADES. D. HANGERS SHALL BE PLACED WITHIN 18 INCHES OF HUB OR JOINT FOR HORIZONTAL CAST IRON PIPE. HUBLESS JOINTS MUST BE SUPPORTED AT EVERY OTHER JOINT EXCEPT THAT WHEN THE LENGTH BETWEEN SUPPORTS EXCEEDS FOUR FEET THEY SHALL BE PROVIDED AT EACH JOINT. E. HANGERS SHALL BE PLACED AT EACH CHANGE OF DIRECTION, WITHIN ONE FOOT OF VALVES AND OTHER APPURTENANCES INSTALLED IN HORIZONTAL PIPING AND NOT MORE THAN THREE FEET FROM END OF EACH BRANCH RUNOUT. F. HANGERS SHALL BE ADJUSTABLE CLEVIS TYPE WITH CONTINUOUS THREADED RODS. SANITARY. GREASE, WASTE AND VENT PIPING A. ALL HORIZONTAL BRANCHES, SEWER AND DRAIN LINES SHALL BE SLOPED A MINIMUM OF 1/8 INCH PER FOOT UNLESS OTHERWISE INDICATED ON PLANS. B. EVERY FIXTURE CONNECTED TO THE DRAINAGE SYSTEM SHALL BE EQUIPPED WITH A WATER SEAL TRAP. C. VENT STACKS SHALL NOT PASS THROUGH ROOF AT VALLEYS, ROOF CRICKETS, IN FRONT OF WINDOWS OR WITHIN 6-0" OF ROOF EDGE. D. MATERIALS SHALL BE AS FOLLOWS: 1) DRAINAGE AND VENT PIPING (BELOW GRADE): SHALL BE HUB AND SPIGOT SERVICE WEIGHT CAST IRON WITH GASKETED PUSH -ON JOINTS. 2) DRAINAGE AND VENT PIPING (ABOVE GRADE): SHALL BE HUBLESS SERVICE WEIGHT CAST IRON WITH NEOPRENE GASKETS AND STAINLESS STEEL BAND JOINTS. DOMESTIC COLD AND HOT WATER PIPING A. PROVIDE WATER HAMMER ARRESTORS ON PIPING AS INDICATED FOR QUICK CLOSING FIXTURES. B. PROVIDE DIELECTRIC UNIONS WHERE DISSIMILAR METALS ARE JOINED. C. ESCUTCHEONS SHALL BE CHROME PLATED BRASS WITH LOCKING SCREWS WHERE PIPES PASS THROUGH FINISHED WALLS. D. EACH HOSE BIBB SHALL BE FURNISHED WITH A VACUUM BREAKER AND SHUT-OFF VALVE. E. PROVIDE PIPING AS FOLLOWS: 1) WATER PIPING (BELOW GRADE): SHALL BE COPPER TYPE "K" ASTM B-88 WITH WROUGHT COPPER FITTINGS AND 95-5 SOLDERED JOINTS. PAINT WITH BITUMASTIC WHEN INSTALLED IN GRADE. 2) WATER PIPING (ABOVE GRADE): SHALL BE COPPER TYPE "L" ASTM B-88 WITH WROUGHT COPPER FITTINGS AND 95-5 SOLDERED JOINTS. COPPER TYPE "K" ASTM B-88 UNDER GROUND. 3) PRESSURE AND TEMPERATURE RELIEF LINES: SHALL BE TYPE "M" COPPER WITH WROUGHT COPPER FITTINGS AND 50-50 SOLDERED JOINTS. F. ALL EXPOSED PIPING WITHIN TOILET ROOMS SHALL BE CHROME PLATED. %IAI \/rr+ A. PROVIDE CONTROL VALVES WHERE NOTED ON PLANS, AND AS REQUIRED FOR COMPLETE REGULATION OR CONTROL OF ALL SYSTEM MAINS, BRANCHES TO GROUP OF FIXTURES, AND TO EACH PIECE OF EQUIPMENT, B. PROVIDE ACCESS PANELS AS REQUIRED TO VALVES, OR GROUP OF VALVES, WHERE CONCEALED AND FOR PROPER MAINTENANCE AND OPERATION OF SYSTEM. C. GATE VALVES: 1) 2-1/2 INCHES AND SMALLER SHALL BE BRONZE BODY, SCREWED BONNET, NON -RISING STEM, SOLID WEDGE, CLASS 125, 200 PSI NON -SHOCK WATER; THREADED END WATTS WGV-SERIES, SOLDERED END WATTS WGVS-SERIES. rrt-r1AIf' A. COMPLETE WATER PIPING SYSTEM SHALL BE PRESSURE TESTED BY CAPPING OR PLUGGING OPENINGS, FILLING SYSTEM WITH WATER AND APPLYING HYDROSTATIC PRESSURE OF 125 PSI FOR PERIOD OF NOT LESS THAN 2 HOURS. B. SOIL, WASTE AND VENT PIPING SHALL BE TESTED BY CAPPING THE ENDS OF THE SYSTEM AND ALL LINES FILLED WITH WATER TO HIGHEST POINT AND ALLOW TO STAND UNTIL INSPECTION IS MADE AND WATER LEVEL REMAINS CONSTANT. INSULATION A. INSULATION SHALL RUN CONTINUOUS THROUGH WALLS, FLOORS AND CEILINGS. B. WHERE INSULATION PASSES THROUGH HANGERS IT SHALL BE PROVIDED WITH A PROTECTION SHIELD, 180 DEGREE ARC GALVANIZED SHEET METAL COVERING 12 INCHES LONG. C. ALL A/C CONDENSATE DRAIN LINES ABOVE GRADE SHALL BE INSULATED WITH 1/2" ARMAFLEX PIPE INSULATION. SEAL ALL SEAMS WITH INSULATION MANUFACTURER'S SOLVENT. NO TAPES ARE ALLOWED. D. GLASS CLOTH JACKET: FACTORY SIZED WHITE, STANDARD WEIGHT, WITH 1-1/2 INCH MINIMUM LONGITUDINAL PRESSURE SEALING LAP, AND SEAL STRIPS FOR BUTT JOINTS. E. VAPOR BARRIER JACKET: FLAME RESISTANT GLASS FIBER ADHERED TO OUTSIDE OF A 1 -MIL ALUMINUM FOIL SHEET WITH LONGITUDINAL PRESSURE SEALING LAP AND SEAL STRIPS FOR BUTT JOINTS. END JOINT CEMENT PERM RATING NOT TO EXCEED .05. F. DOMESTIC HOT WATER SUPPLY PIPING: 1/2 INCH THICK GLASS FIBER MOLDED INSULATION WITH PRE -SIZED FACTORY APPLIED FIRE RATED JACKET OF GLASS CLOTH WITH LONGITUDINAL LAP AND BUTT JOINT STRIPS WITH SELF-SEALING ADHESIVE, G. CONDENSATE DRAINING, DRINKING FOUNTAIN AND ELECTRIC WATER COOLER DRAINS: ELASTOMERIC (FOAM PLASTIC) THERMAL INSULATION 1/2 INCH THICK WITH BUILT-IN VAPOR BARRIER RATED SELF- EXTINGUISHING. INSULATION SHALL HAVE A MAXIMUM THERMAL CONDUCTIVITY OF 0.26K FACTOR AT 70 DEGREES F. MEAN TEMPERATURE, DENSITY OF 5-6 POUNDS PER CUBIC FOOT AND A WATER VAPOR TRANSMISSION OF 0.1 PERMS. STERILIZATION A. AFTER WATER PIPING HAS BEEN THOROUGHLY FLUSHED OUT, STERILIZE THE LINES BY INTRODUCING INTO THEM A SOLUTION OF CALCIUM HYPOCHLORITE OR CHLORIDE OF LIME. OPEN AND CLOSE ALL VALVES WHILE SYSTEM IS BEING CHLORINATED, AFTER THE STERILIZING AGENT HAS BEEN APPLIED FOR 24 HOURS, TEST FOR RESIDUAL CHLORINE AT THE ENDS OF THE LINES. IF LESS THAN 5 PARTS PER MILLION IS INDICATED, REPEAT THE PROCESS. WHEN THE TESTS SHOW AT LEAST 5 PARTS PER MILLION OF RESIDUAL CHLORINE, FLUSH OUT THE SYSTEM UNTIL ALL TRACES OF THE CHEMICAL USED ARE REMOVED. MAKE NECESSARY CONNECTIONS TO STERILIZE PIPING. PLUMBING SYMBOL LEGEND SYMBOL DESCRIPTION POOL 4,220 SANITARY PIPE --------- VENT PIPE ❑® FLOOR DRAIN, AREA DRAIN OR ROOF SPLASH DECK 1,062/30 DRAIN WITH FULL GRATE u0 � FLOOR DRAIN WITH TRAP RESEAL _11LVTR VENT THRU ROOF RWL RAIN WATER LEADER SD STORM DRAIN CD CONDENSATE DRAIN PIPE CO CLEANOUT WCO WALL CLEANOUT J FLOOR CLEANOUT - DOMESTIC COLD WATER PIPE -- DOMESTIC HOT WATER PIPE CD CONDENSATE DRAIN PIPE ASSEMBLY 1 DIRECTION OF FLOW 107 ELECTRICAL ROOM 40/300 GATE VALVE CC VALVE IN VERTICAL ch BALL VALVE Cf) Z CHECK VALVE MALE COUPLING OR UNION __C+ HOSE BIBB E�-C---•- WATER HAMMER ARRESTOR ABV. ABOVE AFF ABOVE FINISHED FLOOR LEVEL BLW. BELOW CEIL., CLG. CEILING DN DOWN EXIST. EXISTING FA FROM ABOVE FB FROM BELOW VTR VENT THRU ROOF VB VACUUM BREAKER WS WASTE STACK Y.. PROJ. No. 23026 i • , • Y CA 924. • � • G i i O ii V • • • G !, G . V F • '101S J. AGUIRRE & ASSOCIATESORA CONSULTING ENGINEERS 9150 SOUTH DADELAND BLVD. GO �ITE 91"M MIAMI, FLORIDA 3315 TELEPHONE: (305) 670-0141 FAX: (305) 670-0144 www.ljaapc.com •••• ••••• • PLUMBING FIXTURE CONNECTION SCHEDULE AREA NAME TOTAL S.F. S.F. OCC, OCCUPANCY OCC. LOAD DESCRIPTION POOL 4,220 ASSEMBLY 90 („] POOL DECK 6,202/30 ASSEMBLY 207 Q Z SPLASH DECK 1,062/30 ASSEMBLY 36 O0 AMERICAN STANDARD MODEL 0356.421 "LUCERNE" T0 (WALL HUNG) ROOM No. ROOM NAME TOTAL S.F. S.F. OCC. OCCUPANCY OCC, LOAD 101 VENDING AREA 42/100 ASSEMBLY 1 Z 102 TICKETS LIFE GUARD'S OFFICE 290 100 ASSEMBLY 3 d103 MALE TOILET 256 ASSEMBLY - J 104 UNISEX TOILET 49 ASSEMBLY - (j 105 FEMALE TOILET 291 ASSEMBLY - O 106 POOL EQUIPMENT ROOM 148 300 ASSEMBLY 1 V O 107 ELECTRICAL ROOM 40/300 ASSEMBLY 1 CC TOTAL OCCUPANT LOAD = 338 OCC. ch PLUMBING FIXTURE CALCULATIONS PER POOL AREA TABLE 424.1.6.1 SWIMMING POOL Cf) Z POOL TOTAL AREA: 4,220 SF MALE FEMALE _O SIZE URINAL W.C. LAVATORY W.C. LAVATORY ~ 2,501 SF - 5,000 SF (REQUIRED) 2 1 1 5 1 O J UPROVIDED. AS PER FBC 424.1.5.1.1 FIXTURES SHALL BE PROVIDED AS INDICATED ON TABLE 424.1.6.1. TIME FIXTURE COUNT ON THIS CHART IS DEEMED TO BE ADEQUATE FOR THE POOL AND POOL DECK AREA THAT IS UP TO THREE TIMES THE AREA OF THE POOL SURFACE (POOL DECK IS 7,595 S.F.) 0 Z TOTAL PLUMBING FIXTURES PROVIDED m UNISEX MALE FEMALE W.C. LAVATORY URINAL W.C. LAVATORY W.C. LAVATORY J a TOTAL PROVIDED 1 1 2 2 3 5 3 SERVICE SINK: 1 PROVIDED (POOL EQUIPMENT ROOM) Y.. PROJ. No. 23026 i • , • Y CA 924. • � • G i i O ii V • • • G !, G . V F • '101S J. AGUIRRE & ASSOCIATESORA CONSULTING ENGINEERS 9150 SOUTH DADELAND BLVD. GO �ITE 91"M MIAMI, FLORIDA 3315 TELEPHONE: (305) 670-0141 FAX: (305) 670-0144 www.ljaapc.com •••• ••••• • PLUMBING FIXTURE CONNECTION SCHEDULE MARK DESCRIPTION WASTE CW HW REMARKS L-1 LAVATORY 1 1/4" 1/2" - AMERICAN STANDARD MODEL 0356.421 "LUCERNE" T0 (WALL HUNG) (20-1/2X18-1/4"): WHITE VITREOUS CHINA (HANDICAPPED). � X11 o Lo FAUCET FOR COLD WATER ONLY: METERING FAUCET FILLER TAP AMERICAN STANDARD MODEL 1340.105 CAST SPOUT, 1.5 GPM. c .� cn PRESSURE COMPENSATING VANDAL RESISTANT AERATOR. CC To- UD ch Z u- 20 FACTORY SET FOR A MAXIMUM OF 0.25 GALLON FLOW PER cc ACTIVATION, ADJUSTABLE FLOW CYCLE. AUTOMATIC SHUT-OFF WITH REPLACEABLE VALVE CARTRIDGE. PUSH BOTTOM ACTIVATOR. DRAIN: 2412.013 1-1/2" TAILPIECE, INTEGRAL PERFORATED GRID CHROME FINISH 1-1/2" INLET- 1-1/2" OUTLET LAVATORY SUPPLY: 3/8" ANGLE VALVE WITH LOOSE KEY HANDLE, CHROME FINISH, FIXTURE CARRIER: BY JOSAM AMERICAN STANDARD MODEL 0356.421 "LUCERNE" L-2 LAVATORY -ADA 1 1/4" 1/2" (20-1/2X18-1/4"): WHITE VITREOUS. (WALL HUNG) FAUCET FOR COLD WATER ONLY: METERING FAUCET PILFER TAP AMERICAN STANDARD MODEL 1340.105 CAST SPOUT, 1.5 GPM. PRESSURE COMPENSATING VANDAL RESISTANT AERATOR. FACTORY SET FOR A MAXIMUM OF 0.25 GALLON FLOW PER ACTIVATION. ADJUSTABLE FLOW CYCLE. AUTOMATIC SHUT-OFF WITH REPLACEABLE VALVE CARTRIDGE. PUSH BOTTOM ACTIVATOR. DRAIN: 2412.013 1-1/2" TAILPIECE, INTEGRAL PERFORATED GRID CHROME FINISH 1-1/2" INLET - 1-1/2" OUTLET LAVATORY SUPPLY: 3/8" ANGLE VALVE WITH LOOSE KEY HANDLE, CHROME FINISH. FIXTURE CARRIER: BY JOSAM WC WATER CLOSET 4" 1" _ SENSOR OPERATOR, BATTERY POWER, FLUSH VALVE, 1.28 (FLOOR MOUNTED) GPF., FLOOR MOUNTED, ELONGATED, COLOR WHITE, AMERICAN STANDARD MADERA FLOWISE, 15" HEIGHT, 1.28 GPF., FLUSHMETER TOILET SYSTEM, MODEL 2234.001, TOP SPUD WITH SELECTRONIC FLOWISE, NO TOUCH, MODEL 6065.121,002 BY AMERICAN STANDAD. BEMIS COMMERCIAL PLASTIC SEAT MODEL 1055, HEAVY DUTY. OPEN FRONT LESS COVER FOR ELONGATED BOWL AND FEATURE LARGE MOLDED -IN BUMPERS. COLOT WHITE. WC -1 WATER CLOSET -ADA 4" 1" - SENSOR OPERATOR, BATTERY POWER, FLUSH VALVE, 1.28 (WALL MOUNTED) GPF., FLOOR MOUNTED, ELONGATED, COLOR WHITE, AMERICAN STANDARD MADERA FLOWISE, 16-1/2" HEIGHT, 1.28 GPF., FLUSHMETER TOILET SYSTEM, MODEL 3043.001, TOP SPUD ' ITH SELECTRONIC FLOWISE, NO TOUCH, MODEL 6065.1121.002 BY AMERICAN STANDAD. BEMIS COMMERCIAL PLASTIC SEAT MODEL 1055, HEAVY DUTY. OPEN FRONT LESS COVER FOR ELONGATED BOWL AND FEATURE LARGE MOLDED -IN BUMPERS. COLOT WHITE. FLOOR DRAIN: JR SMITH (*) NO. 2005 -NB, 6" ADJUSTABLE FD -1 FLOOR DRAIN W/ TRAP PRIMER 4" - - SQUARE TOP NICKEL BRONZE FINISH WITH 1/2" TRAP PRIMER CONNECTION. WH -1 WALL HYDRANT - 3/4" - ZURN #1350 -VB WALL HYRDRANT WITH ALL BRONZE BODY AND PARTS WITH ADJUSTABLE STAINLESS STEEL BOX WITH VACUUM BREAKER. MOUNTING HEIGHT: 18" A.F.F. MS -1 MOP SINK 3" 1/2 1/2 FIAT MODEL NO.TSBC1610 FLOOR MOUNTED 24" X 24" X 12" PRECAST TERRAZO ONE PIECE PRODUCTS BLACK AND WHITE MARBLE -CHIPS CAST IN GRAY PORLAND CEMENT. TSBC 1610 SERIES NEO -CORNER MODEL 12" HIGH WITH 6" DROP FRONT AND STAINLESS STEEL THRESHOLD ONLY, SHOULDERS SHALL NOT BE LESS THAN 2" WIDE WITH 1/2" PITCH TOWARD INSIDE. FAUCET FIAT MODEL 830 -AA, CHROME PLATED WITH VACUUM BREAKER, INTEGRAL STOPS, ADJUSTABLE WALL BRACE, PAIL HOOK AND 3/4"HOSE THREAD ON SPOUT. AMERICAN STANDARD (*) MODEL NO. 6590.525 WASHBROOK UR URINAL 2" 3/4" - FLOWISE 0.125 GPF ULTRA HIGH EFFICIENT URINAL SYSTEM, 3/4" (WALL HUNG) TOP SPUD WALL HUNG WITH SELECTRONIC FLOWISE, BATTERY OPERATION, NO TOUCH. FIXTURE CARRIER: JOSAM(*) SERIES 17560 UR: UR -1 URINAL -ADA 2" 3/4" AMERICAN STANDARD (') MODEL NO, 6590.525 WASHBROOK (WALL MOUNTED) - FLOWISE 0.125 GPF ULTRA HIGH EFFICIENT URINAL SYSTEM, 3/4" TOP SPUD WALL HUNG WITH SELECTRONIC FLOWISE, BATTERY OPERATION, NO TOUCH MOUNTED AT HANDICAPPED HEIGHT EWC-1 ELECTRICAL WATER 1-1/4" 1/2" - WALL MOUNTED BY -LEVEL HAWS MODEL 1119 HI -LO FOUNTAINS. COOLER SH SHOWER 2" 1/2" 1/2"- FLOWISE COMMERCIAL SHOWER SYSTEM 1.5 GPF. SHOWER SYSTEM KIT WITH HAND SHOWER WITH R120SS PRESSURE BALANCE VALVE AND TRIM. A WALL SUPPLY WITH 1/2" NPT FEMALE INLET AND 1/2" MALE OUTLET. 59" METAL SHOWER HOSE, VACUUM BREAKER. 3 FUNCTION WATER SAVING PERSONAL SHOWER, 36" SLIDE BAR, 1,5GPM. FLOW RESTRICTOR AMERICAN STANDARD FLOWISE COMMERCIAL SHOWER SYSTEM, 1.5 GPF SHOWER SYSTEM KID MODEL 1662.211 HB HOSE BIB (GROUND HYDRANT) -- 3/4" -- ZURN Z1360 -VB GROUND HYDRANT ENCASED FLUSH TYPE WITH USED AT POOL AREA. FIVE.(5) GRADE OR FINISH (NON -TRAFFIC) COMPLETE WITH GALVANIZED GROUND HYDRANT TOTAL AT POOL STEEL CASING, ALL BRONZE INTERIOR PARTS. BRONZE SEAT AND AREA. SEE DETAIL ON PLUMBING REPLACEABLE SEAT WASHER, NON TURNING OPERATING ROD DWG. P-7.01. FOR LOCATION SEE WITH FREE-FLOATING COMPRESSION CLOSURE VALVE WITH 3/4" CIVIL DWG. C-3 AND PLUMBING CONNECTION, PLAIN BRONZE BOX AND HINGEDSCORIATED PARTIAL SITE PLAN P1.00 COVER WITH OPERATING KEY LOCK AND "WATER" CAST COVER. WATER HEATER SCHEDULE WATER MARK HEATING SOURCE BTUH MANUFACTURER MODEL NO. COLD HOT WH -1 GAS 3/4" 3/4" 180,000 LOCHINVAR CNR180-080-DF9 Y • G G G GU u •� R ECEATIONAL iwui• • ,• • �v�4 DESIGN AND CONSTRUCTION, INC. 3990 North Powerline Roars Ft, Lauderdale, FL, 33309 Voice: 954.566.3865 Fax: 954.566.3335 3 LLi It w W 0 F- an LLt u,. Q LLQ Q U w >= �d LIJ N< o o� 0 t� V O m O U ZD L1� U) O U C� O CD CD r W Cn Dz 0- 1 c.� 0 �> � 3 ,' ,•� MEC A`1C91 -4L; C'1 (0 I�_ GIO Eek Qb P.E. Lu ' C Ei> 7864 PROJECT NUMBER FILL No. : PO.00.dwg DRAWN : J_B_ REVIEWED; R.M. CHECKED : R.M. DATE : 07-02-13 ISSUE / REVISIONS M uj 0 V T0 Q IL � X11 o Lo -a ._ c .� cn Ci D CC To- UD ch Z u- 20 cc 1 c.� 0 �> � 3 ,' ,•� MEC A`1C91 -4L; C'1 (0 I�_ GIO Eek Qb P.E. Lu ' C Ei> 7864 PROJECT NUMBER FILL No. : PO.00.dwg DRAWN : J_B_ REVIEWED; R.M. CHECKED : R.M. DATE : 07-02-13 ISSUE / REVISIONS