13-749-101GENERAL NOTES 1. THE CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS AND EQUIPMENT NECESSARY FOR THE INSTALLATION OF HVAC SYSTEM IN ACCORDANCE WITH THESE DRAWINGS. 2. THE WORK INCLUDES PROVIDING THE HVAC SYSTEMS, INCLUDING DUCTWORK, DIFFUSERS AND GRILLES, INSULATION, CONTROLS AND EQUIPMENT NECESSARY FOR A COMPLETE FUNCTIONING SYSTEM. HVAC SYSTEM INCLUDES BUT IS NOT LIMITED TO THE FOLLOWING: EXHAUST DUCTWORK SYSTEM WITH GRILLES AND DAMPERS. 3. TEMPERATURE CONTROL SYSTEM INCLUDING LOW VOLTAGE WIRING AND CONDUIT, TRANSDUCERS, ACTUATORS, CONTROLLER. 4. ALL MATERIAL AND EQUIPMENTS SHALL BE NEW OF U.S. MANUFACTURER AND OF GOOD QUALITY OF RESPECTIVE KIND AND GRADE, AND MUST BE FURNISHED SO AS TO PREVENT ANY DELAY IN THE PROGRESS OF THE WORK. ALL WORK THROUGHOUT SHALL BE PERFORMED IN A WORKMANLIKE MANNER BY SUFFICIENT NUMBER OF SKILLED PERSONNEL. 5. ALL EQUIPMENT AND MATERIALS SHALL BE NEW, FREE FROM DEFECTS AND WITH MANUFACTURER'S WARRANTY. 6. THE CONTRACTOR IS RESPONSIBLE FOR VISITING THE SITE OF THE WORK AND BECOMING FAMILIAR WITH THE CONDITIONS OF THE WORK PRIOR TO SUBMITTING A BID. THE CONTRACTOR IS REQUIRED TO BECOME FAMILIAR WITH ALL THE CONTRACT DOCUMENTS PERTAINING TO THE PROPOSED WORK. THE SUBMISSION OF A BID SHALL BE SUFFICIENT TO ESTABLISH THAT THE CONTRACTOR HAS INVESTIGATED THE SITE OF THE WORK AND IS SATISFIED AS TO ALL REASONABLE CONDITIONS TO BE ENCOUNTERED, THE WORK TO BE PERFORMED AND THE MATERIALS TO BE PROVIDED IN THE COMPLETION OF THE PROJECT. 7. FAILURE OF BIDDERS�ITO MAKE REQUIRED VISITATIONS AND/OR INVESTIGATIONS TO INFORM THEMSELVES FULLY OF EXISTING CONDITIONS, AND TO INCLUDE IN THEIR PROPOSALS A SUM SUFFICIENT TO COVER ALL POSSIBLE FIELD CONDITIONS, WILL NOT IN ANY WAY ENTITLE THEM TO ANY EXTRA CHARGES OVER AND ABOVE THEIR ORIGINAL PROPOSALS. 8. CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO PROTECT PROPERTY IN AREAS WHERE WORK IS BEING CONDUCTED. THE CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGES CAUSED TO BUILDING COMPONENTS DUE TO NEW WORK OPERATIONS. PATCH AND REPAIR EXISTING SURFACES DAMAGED AS REQUIRED TO MATCH ADJACENT SURFACES. 9. CONTRACTOR SHALL PROVIDE DURING CONSTRUCTION ALL SAFETY MEASURES AND FEATURES AS REQUIRED BY THE APPLICABLE CODES, RULES AND REGULATIONS HAVING JURISDICTION OVER THE PROJECT. 10. ALL WORK SHALL BE COORDINATED WITH ALL OTHER TRADES AT JOB SITE PRIOR TO FABRICATION AND INSTALLATION OF EQUIPMENT. ANY DISCREPANCIES BETWEEN THE WORK DEPICTED ON THESE DOCUMENTS AND THE ACTUAL CONDITIONS ENCOUNTERED SHALL BE BROUGHT PROMPTLY TO THE ENGINEER FOR REVIEW AND CLARIFICATION. 11. THE WORK THAT IS TO BE DONE UNDER THIS CONTRACT INCLUDES THE FURNISHING OF ALL LABOR, MATERIALS AND EQUIPMENT, PERMITS, FEES, INSPECTIONS, TESTS, INSURANCE, ETC., REQUIRED FOR THE COMPLETION OF THE HEATING, VENTILATING AND AIR CONDITIONING SYSTEMS SHOWN ON DRAWINGS. 12. THE DRAWINGS ARE GENERALLY DIAGRAMMATIC. THEY DO NOT SHOW EVERY BEND, OFF -SET, ELBOW OR OTHER FITTINGS WHICH MAY BE REQUIRED FOR THE INSTALLATION IN THE SPACE ALLOCATED. 13. DRAWINGS ARE NOT TO BE SCALED. UNLESS SPECIFIC DIMENSIONS ARE SHOWN, THE ARCHITECTURAL AND/OR STRUCTURAL DRAWINGS, AND SITE CONDITIONS SHALL GOVERN EXACT LOCATION OF MECHANICAL EQUIPMENT TO BE INSTALLED. 14. IT IS THE INTENT OF THE PLANS AND GENERAL NOTES TO PROVIDE A COMPLETE AND OPERATING INSTALLATION INCLUDING ALL NECESSARY ITEMS REQUIRED, EVEN THOUGH ITEMS ARE NOT INDICATED ON THE DRAWINGS OR IN THE NOTES. ALL WORK CONSIDERED NECESSARY FOR THE COMPLETION OF THE WORK IN PROPER MANNER NOT SHOWN ON THE PLANS OR NOTES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER IN WRITING PRIOR TO BIDS OTHERWISE WORK SHALL NOT BE ADDITIONALLY CHARGED AFTER BID IS AWARDED. 15. SUBMIT SHOP DRAWINGS OF ALL MATERIALS, DUCTWORK, DUCT LAYOUT AND EQUIPMENT FOR REVIEW BY ENGINEER PRIOR TO FABRICATION AND/OR INSTALLATION. AIR CONDITIONING LEGEND SYMBOL DESCRIPTION AHU AIR HANDLING UNIT BD BACKDRAFT DAMPER COND, CONDENSATE CU CONDENSING UNIT CONC. CONCRETE CFM CUBIC FEET PER MINUTE DG DOOR GRILLE E/A EXHAUST AIR EA EACH FLA FULL LOAD AMPS FPM FEET PER MINUTE FPS FEET PER SECOND HP HORSEPOWER HR HOUR IN. INCH KW KILOWATT LBS. POUNDS MAX. MAXIMUM VD MANUAL VOLUME DAMPER (OPPOSED BLADE TYPE) NO. NUMBER O/A OUTSIDE AIR OAL OUTSIDE AIR LOUVER RPM. REVOLUTIONS PER MINUTE REF. REFRIGERANT LINES R/A RETURN AIR S/A SUPPLY AIR TEMP. TEMPERATURE T THERMOSTAT 16. CONTRACTOR SHALL MAINTAIN DURING CONSTRUCTION A SET OF UPDATED AS -BUILT RED -MARKED PLANS AND ISSUE TO OWNER AT COMPLETION OF PROJECT. 17. ALL DUCT SIZES SHOWN ON DRAWINGS ARE CLEAR INSIDE DIMENSIONS. 18. THE CONTRACTOR SHALL TEST ALL EQUIPMENT, MAKE PRELIMINARY ADJUSTMENTS AND CALIBRATE ALL CONTROLS PRIOR TO REQUESTING TEST AND BALANCE SERVICES. 19. NO PORTION OF THE NEW DUCTWORK OR ITS SUPPORTS SHALL MAKE CONTACT WITH PARTITIONS, CEILING, LIGHTS, ETC. 20. CONTRACTOR SHALL WARRANT ALL WORK TO BE FREE OF DEFECTS IN WORKMANSHIP AND MATERIALS FOR A PERIOD OF ONE YEAR AFTER ACCEPTANCE OF THE INSTALLATION. 21. ALL MATERIALS SHALL BE NEW. ANY DAMAGED EQUIPMENT SHALL BE REPLACED OR RESTORED TO ORIGINAL CONDITION. 22. PROVIDE INSULATION MATERIALS, FLEXIBLE DUCTS, ADHESIVES, COATINGS AND OTHER ACCESSORIES WITH FIRE HAZARD RATING NOT TO EXCEED 25 FOR FLAME SPREAD AND 50 FOR SMOKE DEVELOPED. 23. CUT ALL OPENINGS REQUIRED TO ACCOMMODATE THE WORK UNDER THIS CONTRACT AND REPAIR ALL WALLS, ROOF, ETC. DAMAGED BY SUCH CUTTINGS. 24. PROVIDE CEILING/WALL ACCESS PANELS WHERE INDICATED IN THE DRAWINGS AND WHERE REQUIRED TO ACCESS HVAC EQUIPMENT. PANELS SHALL BE RECESSED TYPE, FIRE RATED IF IN FIRE RATED WALLS OR CEILINGS. LOCATION OF PANELS SHALL BE COORDINATED WITH ALL THE OTHER TRADES. 25, CONTRACTOR SHALL OBTAIN THE SERVICES OF AN INDEPENDENT, CERTIFIED TEST AND BALANCE COMPANY TO BALANCE ALL THE AIR SYSTEMS AFFECTED BY THE NEW WORK TO THE CFM QUANTITIES INDICATED ON THE PLANS. CONTRACTOR SHALL SUBMIT (3) COPIES OF REPORT TO ENGINEER UPON COMPLETION FOR REVIEW. REPORT SHALL INCLUDE EQUIPMENT MANUFACTURER, MODEL NUMBER AND ALL OTHER INFORMATION REQUIRED BY INDUSTRY STANDARDS TO MAKE REPORT COMPLETE, 26. FILTERS FOR CRU'S SHALL BE IN PLACE DURING CONSTRUCTION, AND A NEW SET SHALL BE PROVIDED BY THE CONTRACTOR PRIOR TO TEST AND BALANCE. 27. DURING CONSTRUCTION, ALL EXHAUST DUCTWORK OPENINGS IN THE AREAS AFFECTED SHALL BE FITTED WITH BLANKET TYPE, DISPOSABLE 1" THICK SYNTHETIC MEDIA IN ORDER TO PREVENT CONSTRUCTION DEBRIS FROM ENTERING AND ACCUMULATING INSIDE THE DUCT SURFACES AND THE CEILING CAVITY. 28. ALL NEW EQUIPMENT SHALL BE IDENTIFIED WITH THE SAME DESIGNATION SHOWN ON THE DRAWINGS. IDENTIFICATION SHALL BE WITH ENGRAVED PLASTIC NAMEPLATES USING 1" LETTERS. NAMEPLATES SHALL BE MINIMUM 4"X2" IN SIZE. LETTERS SHALL BE WHITE AND PLATE BACKGROUND SHALL BE BLACK. 29, UPON COMPLETION, CONTRACTOR SHALL CLEAN ALL DUST AND DEBRIS IN AREAS WHERE WORK WAS CONDUCTED. 30. ALL WORK SHALL CONFORM WITH THE 2010 FLORIDA BUILDING CODE AND ALL APPLICABLE CODES AND REGULATIONS, AIR DISTRIBUTION LEGEND DUCT: FIRST FIGURE IS SIDE DUCT SMOKE DETECTOR X FIRE DAMPER(S) X 24X12 SHOWN (SEE NOTE #4) ® X FC n^n^n DUCT SECTION: SUPPLY & FLEXIBLE DUCT; FLEXIBLE RETURN OR EXHAUST SMOKE CONTROL CONNECTION (FC) /VVVV' U.C. " ALL ELBOW MUST BE PROVIDED ALL ALUM. WITH TURNING VANES WHETHER UNDERCUT DOOR ANICAi,, OR SHOWN ON DWGS. SURFACE SURFACE V OT THERMOSTAT (SEE NOTE 3) TYP. 45' TAP -OFF WITH VOLUME DAMPER i VD VOLUME DAMPER TRANSITION RECTANGULAR DOOR VD M TO ROUND SPLITTER DAMPER MOTORIZED DAMPER 1/2" X 1/2" X 1/2" W1 B IRDSCREEN NOTES 1. 45' TAP -OFFS, SPLITTERS AT EACH TAP -OFF AND TEE, AND ACCESS DOORS SHALL BEE USED WHERE REQUIRED, WHETHER OR NOT INDICATED IN THE DRAWINGS. 2. IN AREAS WHERE NON -REMOVABLE CIELINGS ARE USED, PROVIDE 45• TAP -OFFS OF THE FIXED TYPE, WITH WIDTH PROPORTION TO BRANCH CFM. 3. THERMOSTAT MUST BE INSTALLED BETWEEN 48" MAX. HIGH ABOVE FINISHED FLOOR (FBC 2010 CHAPTER 11) COORDINATION NOTES 1. AS PART OF THIS CONTRACT, THE SUB -CONTRACTOR AND THE CONTRACTOR ARE RESPONSIBLE FOR COORDINATION AND VERIFICATION THAT ALL EQUIPMENT, SHOWN IN THE ARCHITECTURAL DRAWINGS PARTICULARLY, BUT NOT LIMITED TO THE ARCHITECTURAL EQUIPMENT PLAN, INCLUDE ALL SERVICE/UTILITY REQUIRED TO OPERATE THE EQUIPMENT SHOWN. ANY DISCREPANCIES ARE TO BE POINTED OUT DURING THE BIDDING PROCESS. 2. CONTRACTOR SHALL COORDINATE FINAL LOCATION OF ALL CEILING MOUNTED FIXTURES, OUTLETS, DEVICES AND/OR EQUIPMENT SHOWN IN THESE ENGINEERING DRAWINGS WITH THE ARCHITECTURAL REFLECTED CEILING PLANS AND/OR APPLICABLE DETAIL DRAWINGS. ANY DISCREPANCY AND/OR CONFLICT MUST BE BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER PRIOR TO PROCEEDING WITH ANY ROUGHING -IN WORK. 3. DISCREPANCIES NOT POINTED OUT DURING THE BIDDING PROCESS WILL BE RESOLVED BY THE CONTRACTOR AS PER THE ARCHITECT DETAILS AT NO ADDITIONAL COST TO THE OWNER. EQUIPMENT SPECIFICATIONS: EXHAUST AIR DUCTWORK: SHALL BE GALVANIZED SHEET STEEL, DESIGNED, CONSTRUCTED AND INSTALLED PER 2" STATIC PRESSURE CLASSIFICATION OF THE SMACNA'S "HVAC DUCT CONSTRUCTION STANDARDS- METAL AND FLEXIBLE" MANUAL, LATEST EDITION. RECTANGULAR MANUAL VOLUME DAMPERS: SHALL BE RUSKIN MODEL MD35 OR EQUAL. MULTIPLE OPPOSED BLADE OR SINGLE BLADE, FURNISHED COMPLETE WITH FACTORY FABRICATED LOCKING HAND QUADRANT. PROVIDE WITH 2" STAND-OFF WHEN INSTALLED ON EXTERNALLY INSULATED DUCT. DUCT SUPPORTS: SHALL BE GALVANIZED SHEET STEEL STRAP. WIDTH, GAGE AND SUPPORT INTERVALS PER SMACNA'S "HVAC DUCT CONSTRUCTION STANDARDS -METAL AND FLEXIBLE" MANUAL, LATEST EDITION. EXHAUST GRILLES: AS SCHEDULED. EXHAUST FANS: AS SCHEDULED. WAC -1: AS SCHEDULED. GENERAL FLOOR PLAN NOTES: 1. ALL MECHANICAL EQUIPMENT INSTALLED OUTDOORS AND THAT IS EXPOSED TO THE WIND SHALL BE BUILT AND ANCHORED TO SUSTAIN HURRICANE FORCE WINDS AS OUTLINED IN SECTION 6 OF ASCE STANDARD 7. WIND VELOCITY (3 -SECOND GUST) USED IN STRUCTURAL CALCULATIONS SHALL BE IN COMPLIANCE WITH FBC REQUIREMENTS. HVAC DESIGN REQUIRES: YES NO DUCT SMOKE DETECTOR X FIRE DAMPER(S) X SMOKE DAMPER(S) X FIRE RATED ENCLOSURE X FIRE RATED ROOF/FLOOR CEILING ASSEMBLY X FIRE STOPPING X SMOKE CONTROL X WTYPE OF DIFFUSER A 1W DIRECTION OF FLOW 6x6 � 5 OSIZE OF DIFFUSER AMOUNT OF CFM AIR OUTLET TAG N.T.S. PROJ, No, 23026 CO24 G . ra • LOUIS J. AGUIRRE & ASSOCIATES P.A. CONSULTING ENGINEERS 9150 SOUTH DADELAND BLVD. 1-011f 900 MIAMI, FLORIDA • y x3156 TELEPHONE: (305) 670-0141 FAX: (305) 670-0144 �.�• www.ljoopo.com :...` AIR DISTRIBUTION SCHEDULE J.B. DESIGNATION A B C DATE MANUFACTURER TITUS RUSKIN TITUS MODEL NO. AND f OR 50 F ELF6375DXD CT 700L CATALOG NO. ALL ALUM. ,ME ANICAi,, SURFACE SURFACE SURFACE FRAME TYPE SE ; B64 EGG CRATE LOUVER DOOR DEVICE TYPE 1/2" X 1/2" X 1/2" W1 B IRDSCREEN GRILLE FUNCTION E/A E/A OR O/A MAKE-UP AIR PATTERN SEE DRAWING SEE DRAWING SEE DRAWING OPPOSED BLADE DAMPERS YES -- -- NOTES: 1. ALTERNATE MANUFACTURERS. SEE SPECIFICATIONS. 2. ALL AIR DEVICES SHALL BE ALLALUMINUM CONSTRUCTION AND FULLY GASKETED. 3. UNLESS OTHERWISE NOTED, ALL AIR DEVICES FINISH SHALL BE BAKED OFF-WHITE. 4. FOR SQUARE NECK OUTLETS CONNECTED TO A ROUND FLEXIBLE OR RIGID DUCT, PROVIDE THE REQUIRED INSULATED SQUARE TO ROUND TRANSITION. 5. PROVIDE MIAMI-DADE COUNTY APPROVED HURRICANE LOUVERS. W r� V O M O r� V LL r� v7J O C) 8 O O O 1 W W 0- I Y •• RE`s EATInNAL DESIGN AND CONSTRUCTION, INC, 3900 North Powerline Road Ft. LaUderdale, FL 33309 Voice: 954.566.3885 Fax: 954.566.3335 r Lon J � r 3 W F- 0a .a Q A� !U j� >md � r z 7 Z 9 couj < z U .7- M Q r CO p J CNI co cn • Q U) u PROJ'EOT� ,NUMBER K I K E No. M0.00 dwg DRAWN : J.B. ti R.M. CHECKED R.M. DATE 07-02-13 ti w� O A- 0 ,ME ANICAi,, MO,.P E " LICE SE ; B64 PROJ'EOT� ,NUMBER K I K E No. M0.00 dwg DRAWN : J.B. REVIP,SED: R.M. CHECKED R.M. DATE 07-02-13 ISSUE / REVISIONS SHEET TITLE SYMBOL LEGEND AND GENERAL NOTES -HVAC SHEET NUMBER M0.00