13-749-099
1, ELECTRIC RUNS SHOWN ARE DIAGRAMMATIC, ACTUAL ROUTING SHALL BE COORDINATED WITH FIELD CONDITIONS y COND. WIRE AND OTHER TRADES. DO NOT SCALE ELECTRICAL DRAWINGS. _ .. CKT # 2. ALL CONDUITS SHALL BE 1/2" MINIMUM ABOVE GRADE (3/4" UNDERGROUND) UNLESS OTHERWISE NOTED (UON). REMARKS J. ALL WIRE SHALL BE THHN/THWN COPPER, MINIMUM SIZE 112 (UON). ALUMINUM CONDUCTORS ARE NOT PERMITTED. 1200 �- -----� ( CKT: L-6) A NAMEPLATES 20/1* (CON ) TROL 4. SHALL BE PROVIDED AT ALL MAINS AND SWITCHES AND OTHER CONTROL DEVICES WHERE THE LOAD 1 1600 18515 38000 CONTROLLED IS NOT READILY 0 READ L APPARENT. LIGHTING 912 1/2" 20/1 5. CONTRACTOR SHALL BALANCE LOADS ACROSS ALL SYSTEM PHASE LEGS AND ON SINGLE PHASE, 3 -WIRE SYSTEMS. 112 PE PE CELL 6. ALL MATERIALS, EQUIPMENT AND INSTALLATIONS SHALL COMPLY WITH THE LATEST EDITION OF THE FLORIDA 4 LIGHTING 112 1/2" 20/1 BUILDING CODE (FBC) AND THE 2011 NATIONAL ELECTRICAL CODE (NEC). 1/2" 112 BOOSTER PUMP (3/4 HP) PE 1920 7. ELECTRICAL WORK SHALL BE PERFORMED BY A LICENSED AND INSURED ELECTRICAL CONTRACTOR: CONTRACTOR EXT LIGHTING *** 912 1/2" 2011* 3/4" SHALL PROVIDE EVIDENCE OF PROPERTY DAMAGE AND PUBLIC LIABILITY INSURANCES. r 8, ' CONDUITS SHALL BE RUN CONCEALED IN ALL FINISHED AREAS. EXPOSED CONDUITS SHALL BE RUN NEAT AND ELEC. HELD LTG. CONTACTORS (SIZE 8 EITHER PARALLEL OR PERPENDICULAR TO WALLS k CEILINGS. 110 9. EMT MAY BE USED ABOVE GRADE AND OUT OF WEATHER WHEN PERMITTED BY CODE. SCH 40 PVC MAY BE do POLES PER SCHEDULE) 112 USED UNDERGROUND (UG), WHERE NOT SUBJECT TO PHYSICAL DAMAGE, HEAT OR SUNLIGHT 9 Cl 10. EXPOSED EXTERIOR CONDUIT SHALL BE RIGID METAL (RMC) OR INTERMEDIATE METAL CONDUIT (IMC). SCH 80 RECEPTS 912 1/2" PVC MAY BE USED WHERE NOT SUBJECT TO PHYSICAL DAMAGE 20/1 11. ALL EXPOSED TRANSITIONS FROM UNDERGROUND PVC SHALL BE RMC OR IMC CONDUIT FROM 1a" BELOW GRADE LIGHTING CON'T'ROL DIAGRAM 11 INCLUDING NINETY. WHERE A RACEWAY ENTERS A BUILDING FROM UNDERGROUND, IT SHALL BE SEALED PER NEC 2300 360 12 INCLUDING SPARES. (N. T. S.) 12. ALL ELECTRIC EQUIPMENT ENCLOSURES SHALL BE ACCESSIBLE ONLY TO AUTHORIZED PERSONNEL. 20/1 13. OBTAIN ENGINEERS' APPROVAL PRIOR TO PENETRATING STRUCTURAL MEMBERS, 1 HAND DRYER 14. IN THE EVENT FIELD CONDITIONS DIFFER FROM CONTRACT DOCUMENTS, FIELD CONDITIONS SHALL GOVERN. 15. THE CONTRACTOR SHALL IMMEDIATELY REPAIR ANY DAMAGE CAUSED TO EXISTING FACILITIES. LTG CONTACTOR SCHEDULE 16, MISC. ITEMS OBVIOUSLY REQUIRED FOR A COMPLETE AND OPERATING SYSTEM BUT NOT SPECIFICALLY CALLED FOR 20/1 1/2" ON THE DRAWINGS OR IN THE SPECIFICATIONS SHALL BE PROVIDED BY THE CONTRACTOR AT NO EXTRA COST TO HAND DRYER Sw. LC/ AME'/ROLE LOAD T. 2 40 50, THE OWNER. (NUTS, BOLTS, MASONRY ANCHORS, CONDUIT AND EQUIP. SUPPORTS, DRILLING, WELDING, RECEPTS PE1 SECURITY LTG. L-6 k d 1/2" ` SCAFFOLDING, CRANE SERVIC+_, ETC.) 3/4" �_� WP DECK RECEPTS. l r GROUND ALL SYSTEMS AND EQUIPMENT PER NEC 9250. 18 DRINKING FOUNT. 112 18. ANY EXTERIOR RECEPTACLES SHOWN ON THESE PLANS SHALL BE 20 AMP, WEATHER RESISTANT, SIDE WIRED WITH ALL CONTACTORS SHALL BE EQUAL TO SqD CUSS 8903, 3/4" WP ENCLOSURES WITH "EXTRA DUTY" SAFETY COVER PER NEC J406.9(B). TYPE L, ELECT. HELD WITH 120V COIL, MOUNT IN N-1 19, ALL DISCONNECT SWITCHES .;HALL BE SIZED FOR THE LOAD SERVED AND SHALL BE HP RATED, HEAVY DUTY ENCLOSURE( LCE) . 20 (LION). PIE CELL SHALL BE EQUAL TO INTERMATIC IK4200 SERIES 20. PANELS, PANELBOARDS, SWIT,-HBOARDS, MOTOR CONTROL CENTERS, ETC. SHALL HAVE COPPER BUS AND SHALL. AND SHALL FACE NORTH AND BE LOCATED AWAY FROM (OR 1/2" BE MARKED AS REQUIRED BV NEC 110-16, 110,24 ANQ 408,4(8). SHIELDED) FROM ARTIFICIAL LIGHT SOURCES. 21, ALL FUSES SHALL BE CURRENT LIMITING (LION). USE TIME DELAY FOR MOTOR CIRCUITS AND NON -TD FOR 22 MAINS. 112 22. VERIFY EQUIPMENT CURRENT INTERRUPTING RATINGS FOR ALL EQUIPMENT PRIOR TO CONSTRUCTION. 2011 23. CLOSELY COORDINATE ALL SERVICE ENTRANCE WORK WITH ELECTRIC UTILITY COMPANY. TELEPHONE 24. CLOSELY COORDINATE TELEPHONE SERVICE WORK WITH TELEPHONE UTILITY COMPANY. 360 1600 25. UPON COMPLETION OF WORK CONTRACTOR SHALL FULLY INSTRUCT OWNER'S REPRESENTATIVE IN COMPLETE 912 1/2" OPERATION OF ALL ELECTRlC1L SYSTEMS. 2011 26. CONTRACTOR SHALL GUARAN7EE ALL MATERIALS AND WORKMANSHIP FOR A MINIMUM OF ONE YEAR FROM DATE OF EX FAN 11 25 ACCEPTANCE 1050 1300 27. PROVIDE A FUSE HOLDER AND FUSE IN THE PRIMARY SIDE OF EACH UNGROUNDED CONDUCTOR OF ALL BALLASTS 912 112" OR TRANSFORMERS. HOLDEPS IN POLES SHALL BE BUSSMAN "HEB" SERIES, OR EQ. 2011 28. ALL UNDERGROUND CONDUIT:, SHALL BE BURIED WITH A MINIMUM OF 1a" COVER, FPL SERVICES SHALL BE 24" EX FANS 2 k 3 27 MINIMUM. FPL PRIMARY COA DUITS SHALL BE INSTALLED ACCORDING TO FPL SPECIFICATIONS. 112" 29. DISTANCE BETWEEN PULL BO.(ES SHALL NOT EXCEED 400' AND MAY BE INSTALLED WHERE REQUIRED BY 29 500 300 CONTRACTOR FOR EASE OF I VSTALLATION. 30 TYPE SqD 'NQ' (OR EQ.) MAIN BUS 225 AMP SERVICE 120 PANEL L - 2400 / 1 ,3W NEUTRAL FULL MOUNTING SURF MAIN 225A MCB POLE 42 AIC 22,000 * * BKR COND. WIRE REMARKS CKT # VA CKT # REMARKS WIRE COND. BKR A C 20/1* 1/2" 912 BECS CONTROLS 1 1600 18515 38000 2 LIGHTING 912 1/2" 20/1 20/1* 1/2" 112 CL FEEDER 3 ,a S�A� 1900 880- 4 LIGHTING 112 1/2" 20/1 30/1 1/2" 112 BOOSTER PUMP (3/4 HP) 5 1920 6 EXT LIGHTING *** 912 1/2" 20/1 2011* 3/4" 912 HEATER CONTROLS 7 500 8 POOL LT Tx. (LED) *** 110 314" 2011* 20/1* 112 HEATER PUMP 9 165U— 360 10 RECEPTS 912 1/2" 20/1 20/1 1/2" 110 HAND DRYER 11 2300 360 12 1 RECEPTS 112 1/2" 1 20/1 20/1 1/2" 110 1 HAND DRYER 13 2300 540 14 RECEPTS 912 1/2" 20/1 20/1 1/2" 910 HAND DRYER 15 2 40 50, 16 RECEPTS 112 1/2" 20/1 20/1 3/4" 910 WP DECK RECEPTS. 17 360 102 18 DRINKING FOUNT. 112 112" 20/1 20/1 3/4" 910 WP DECK RECEPTS. 19 1360 20 RECEPT, VENDING 112 1/2" 20/1 20/1 1/2" 912 RECEPTS. 21 540 1600 22 RECEPTT, VENDING 112 1/2" 20/1 2011 1/2" 112 TELEPHONE 23 360 1600 24 RECEPT, VENDING 912 1/2" 20/1 2011 112" 912 EX FAN 11 25 700 1300 1050 1300 26 28 AC RECEPT 912 112" 20/2 2011 112" 112 EX FANS 2 k 3 27 2011 112" 912 GAS WATER HTR. 29 500 300 30 INVERTER (SITE EM LIS) 12 112 2011 2011 112" 112 IRRIG. CTLS. 31 300 50 32 SITE EXIT LTS 1 912 314-'\2011 2011 SPARE 33 1250 1000 34 SPARE – - 2011 2011 – – SPARE 35 125 15Q 36 PARE – – 2011 - - - SPACE 37 .1 38 SPACE 39 - - 40 42 SURGE PROTECTION (INCL) (INCL) 20/2 41 TOTAL CONNECTED LOAD: 36200 VA 18100118100 25X LARGEST MOTOR: 480 CONTINUOUS AT 25%: 590 * GFCI BREAKER TOTAL COMPUTED LOAD: 37270 VA (155 AMPS, 120/24OV) ** HANDLE TIE (NEC 210.4(B)) FEEDER: 3– #4/0, #2(G) IN 2" NIP. *** THRU LTG. CONTROLS CONSULTANTS . OF FLORIDA INC. EN 5351 RECREATIONAL D ESIGN AND CONSULTING ENGINEERS CONSTRUCTION, INC. 1445 S.W. 21st Avenue 3990 North Powerline Road Fort Lauderdale, Florida Ft. Lauderdale, FL 33309 (954) 584-7904 Voice: 954.566.3585 THESE DEMONS ! DRAMANOS ANE THE INTBU ECTUAL Fax: 954.566.3335 PROPERTY OF CONSTRUCTION CONSULTANTS AND MAY NOT BE RErRODUCM. IN PART OR IN MNHOU Urr OUT WRfTTEN PERMISSION. LJ cr_T D 3: -z i U w rx J • It ►- LU Uj f� 1- E w 0 O T C 1. 01 U w I^ M Q�NLI tr � o:2 a w w O LU C FM Ch a r <p r z T- 0 � M T 30. ALL METAL JUNCTION BOXES AND PULL BOXES SHALL BE GROUNDED, QfUj Q. C)31. ALL ABOVE GROUND WP JUN TION BOXES SHALL BE GALVANIZED NEMA 3R, L` CV 32. IT IS THE CONTRACTOR'S RE!, TO VERIFY AND LOCATE ALL EXISTING UG FACILITIES INCLUDING ELECTRIC © .i """� POWER, TELEPHONE, CAN, V ITER, SEWER, GAS, FLOOD/STORM DRAINAGE, IRRIGATION OR ANY EXISTING UG _ n4-0 SYSTEM PRIOR TO ANY EXCA IATIONS. 0 00 " a • - w > � 33. TRENCHES SHALL BE BACKFILLED AND TAMPED TO ORIGINAL DENSITY a N 34. RESTORE ALL EXCAVATED k TRENCHED AREAS TO ORIGINAL CONDITIONS, INCLUDING SOD, PAVING, PLANTINGS, ETC. 35. BEFORE FINAL PAYMENT THE CONTRACTOR SHALL PROVIDE TO THE OWNER A COMPLETE SET OF AS -BUILT DRAWINGS. THESE DRAWINGS' SHALL INCLUDE MEASUREMENTS OF UG CONDUITS AND PULL BOXES MEASURED TO mE PERMANENT STRUCTURES OR LANDMARKS. 36. ALL H.I.D. LAMPS SHALL INCi.UDE MINIMUM 1 YEAR WARRANTY. J= 37. CL2, CHEMICAL CONTROLLERS AND BOOSTER PUMPS SHALL BE ELECTRICALLY INTERLOCKED WITH THE FILTER • © Q z • -PUMP MOTOR CIRCUIT TO OFERATE ONLY WHEN FILTER PUMP OPERATES. EQUIPMENT ROOM EXH. FAN SHALL BE' r. CONNECTED TO OPERATE CO/ITINUALLY OR WHEN FILTER PUMP OPERATES. Cp 0 a 38. ALL METAL POOL STRUCTURES, FITTINGS, EQUIPMENT, LIGHTING, PUMPS, HEATERS AND ENCLOSURES SHALL BE ❑ V' 0 39. UNDERGROUND WIRING SHALL NOT BE RUN UNDER OR WITHIN 5 OF INSIDE WALL OF POOL (NEC 680.10), BONDED WITH A 18 SOLID CJ CONDUCTOR PER NEC 1680.26 k FBC. X 0 40. PUMP MOTOR STARTERS SHA, .L BE EQUIPPED WITH HA ND- OFF-AUTOMATIC SWITCHES. 41. ALL 15 AND 20 AMP, 120V DUMP CIRCUITS SHALL BE PROTECTED WITH GFCI (NEC 680.22.B). w a w M AY LaAD SUMMARY: z see,, GRAY, BOTTOM AT 12 AFF, SERVICE: M A/ k CO: 400 kcml DISC. vEn►�Ora SAY FRANKE. P.E 80 (HI–LEG): 11/0 3012P =J i RIDA RECD. #4l7 0 J6 CU TO GRD. J wQ FOR TKE FIM COORDINATE SERVICE WORK WITH PE CELL (ON WALL OUTSIDE ELEC. RM INTERLOC CHEMICAL N3R HEATER: < PROJECT NUMBER FPL CUSTOMER PROJECT ENGINEER. USE POLARIS JIPL SERIES ) (f� .1 3- 112 IN 1/2" C. CONTROLS, ETC. TO RUN O k PUMP. ►T- 113-0401 MS. SHINA RANA, 305-387-6653 INSULATED TAPS (OR EQ). ONLY w/CIRC. PUMP RUN CONDUI " TO ALL PROVIDE EA. w1 1 SPARE PORT (TO PNL 'L' o OUTLETS k I VSTALL 2" PVC w/PULL STRING ) SD VAC -PACK PULL STRING TO PROP LINE METER `=/aFILE N0, ( / ) N LPREWIRE� - �- WIREWAY,• 6 Sq (min), LENGTH AS REQ'D 3- jf l Z J12(G) w 0�- ATTACH TO A/, C/, SR CIRC, IN 3/4" I UV I DRAWN : N. J. F. NEUT. do TELEPHONE RISER D D E C NEUT. GEC ONLY LI�dL' VAKPAK SANIT'Z O O SR ROOSTER I REVIEWED: V. J. F. TO FPL HANDHOLE 400A PANEL 1RUMr CHECKED: ` V. J . F AT BASE OF POLE SURGE MAIN 1 MAIN 2 LTG. CTL REMOTE VF0 DISC. 1 (3) 1 (COORD, ALL WORK w/ ATT) 120/24OV, 30 A !'AL EL ENCL, EM-BALLAS CONT L I a 0 - (OPEN DELTA) s4w 60 100 (LCE) 100W �3r DISC. INTERLOC TO 20 —3F4w 3F4W 120V NF I _ a , I 0 DATE 5-22-13 OG 50 100 (MAIN S) C JOAl2P RUN ONLY, I - , 2 w/CIRC. PUMP (CL FUSES) (CL FUSES ISSUE/REVISIONS EXTEND GEC TO EACH F N-1 N-1 ) L-30 D 1 D2 D2 N3R I E 1 w BROOKS 936 MAIN, per NEC 250.24(C) 112's O O 10 O i _ pa 1 8/9 FIRE COMMENTS CONC. HANDHOLE k $Q�_DOWN LID WIRES MUST NOT BEAR [A " MAIN 11 INTERSYSTEM GRD. BUS D1 E1 IN 1/2 TO POLE 'Y' / MAIN J2 1 I 0 i N N (FURN w/ POOL TO PNL 'L' 1 i •5 1 Q C9 (OR APPROVED EQ.) ON BOX LID OR SIDES. 1/4 x2 x12" (NEC 250.94) ' _ 8 SOL CU ( ) ,�, z �A 1 X10 s "IN EQUIP, INSTALL D r�POOL BND G ( I � \\\ GRADE AVAILABLE FAULT CURRENT AT THE SECONDARY OF FPL S AERIAL SP CIRC PUMP VAC PACK 3/4 BY EC), ( _rya �.._ N 16 CU (MIN) ) ' //12(G) I RESIN–CAST WATERPROOF 3M — _ _ _ � TRANSF. IS 30, (y) (DATA FURNISHED BY FPL.) ) TYR 2- 112, 684 AMPS s m . IN 112 ❑ SPLICES OR POLARIS BLUE SPLICES CALC'D, AFC AT METER IS <11,000 AMPS(sym). CW INSTALL SURGE PROTECTOR, INSTALL SURGE PROTECTOR NOTE: / (SUITABLE FOR WET t OC). I BASED ON DISTANCES k WIRE SIZE SHOWN. " P i EQ. TO SqD ISDSA3650 AT PANEL, EQ. TO SqD SEE POOL EQUIPMENT AND MECHANICAL _ i�R * AND MAINS SHALL BE RATED A MINIMUM OF 50K AMPS WITH o ?• COMPONENTS SDSA 1175 DRAWINGS FOR LOCATIONS OF ALL • I I 18 MIN. REJECTION CLIPS k CURRENT LIMITING (FLISETRON) FUSES. EQUIPMENT, PUMPS, ETC. WITHIN PANEL 'L' SHALL BE RATED FOR 22,000A s m . z BURIED FOUNDATION 1— EQUIP. GROUNDING CONDUCTO,2 - - - - (Y) �� METAL** STEEL o a "� CWP ( ) A 2- 400 kcml, J1/O (B/), J4/0(N) IN 3" C. MSR CALCS. (PER NEC 430) CRUSHED ROCK AT BOTTOM 9 �' , o 6' B 2- 400 kcml, j1/0, J4/0 IN 2" NIP. 10 HP, 24OV, 30, FLC =,28A (TBL 430.250) OF JUNCTION BOX. '� MIN. 28A x 1,25 = 35A (18 THWN) ' C (SEE PANEL SCHEDULE) 28A x 1.75 = 49 -> 50A DE FUSE (430.52.C) GROUND SERVICE TO FOUND N. STEEL, 5/8 xi0' CU -CLAD GRD. ROD AND METAL D 4-`6,8(G) IN 1" NIP. SPLASH DECK (VAK PACK): Z5 HP, 24OV, 30, FLC = 22A SHEET TITLE C.W.P. (** IF AVAILABLE) ELECTRICAL RISER' 22A x 1.25 28A (10 THWN) CONCRETE HANDHOLE TYP. ( ) N.T.S. D2 3- J8, 11O(G) IN 1" C. 22A x 2.5 2 = 55 –> 60A C.B. 0 ELECTRIC NOTES, O HP, 240V, 10, FLC = 12A (TBL 430.248) (N.T,S,) _ E 4– J2, 16(G) IN 1-1/4" NIP. 12A x 1.25 = 15A 14 THWN SCHEDULES and ENCLOSURES PER NECJ314.30. CONDUCTORS k SPLICES El 4- J21 18(G) IN 1-1/2" C. 12A x 2.5 = 30A C. B. RISERS r---- SHALL BE SUITABLE FOR WET LOCATIONS (314.30(C)) F 4– X12, 112(G) IN 1/2" C. SHEET NUMBER • G 11/0 CU E-1.02 r r 10 LOA.W LOA TOTAL _LOADS MAIN jf1 – 11640 11640 ` `. 314" C. (NP) MAIN /2 PANEL 'L' 6380 38000 12135 – 18515 38000 N D Li l CONTINUOUS: (INCL) - - _ � ,a S�A� 7• " 25% LRGST MTR. 480. 2910 2910 M � 4 x4 x3/4 BACKBOARD, TOTAL 43900 26685 71065 VA GAS MARINE PLYWOOD PAINTED N AT 240V 1 a3 64 247 AMPS ❑ If , hUj GRAY, BOTTOM AT 12 AFF, SERVICE: M A/ k CO: 400 kcml DISC. vEn►�Ora SAY FRANKE. P.E 80 (HI–LEG): 11/0 3012P =J i RIDA RECD. #4l7 0 J6 CU TO GRD. J wQ FOR TKE FIM COORDINATE SERVICE WORK WITH PE CELL (ON WALL OUTSIDE ELEC. RM INTERLOC CHEMICAL N3R HEATER: < PROJECT NUMBER FPL CUSTOMER PROJECT ENGINEER. USE POLARIS JIPL SERIES ) (f� .1 3- 112 IN 1/2" C. CONTROLS, ETC. TO RUN O k PUMP. ►T- 113-0401 MS. SHINA RANA, 305-387-6653 INSULATED TAPS (OR EQ). ONLY w/CIRC. PUMP RUN CONDUI " TO ALL PROVIDE EA. w1 1 SPARE PORT (TO PNL 'L' o OUTLETS k I VSTALL 2" PVC w/PULL STRING ) SD VAC -PACK PULL STRING TO PROP LINE METER `=/aFILE N0, ( / ) N LPREWIRE� - �- WIREWAY,• 6 Sq (min), LENGTH AS REQ'D 3- jf l Z J12(G) w 0�- ATTACH TO A/, C/, SR CIRC, IN 3/4" I UV I DRAWN : N. J. F. NEUT. do TELEPHONE RISER D D E C NEUT. GEC ONLY LI�dL' VAKPAK SANIT'Z O O SR ROOSTER I REVIEWED: V. J. F. TO FPL HANDHOLE 400A PANEL 1RUMr CHECKED: ` V. J . F AT BASE OF POLE SURGE MAIN 1 MAIN 2 LTG. CTL REMOTE VF0 DISC. 1 (3) 1 (COORD, ALL WORK w/ ATT) 120/24OV, 30 A !'AL EL ENCL, EM-BALLAS CONT L I a 0 - (OPEN DELTA) s4w 60 100 (LCE) 100W �3r DISC. INTERLOC TO 20 —3F4w 3F4W 120V NF I _ a , I 0 DATE 5-22-13 OG 50 100 (MAIN S) C JOAl2P RUN ONLY, I - , 2 w/CIRC. PUMP (CL FUSES) (CL FUSES ISSUE/REVISIONS EXTEND GEC TO EACH F N-1 N-1 ) L-30 D 1 D2 D2 N3R I E 1 w BROOKS 936 MAIN, per NEC 250.24(C) 112's O O 10 O i _ pa 1 8/9 FIRE COMMENTS CONC. HANDHOLE k $Q�_DOWN LID WIRES MUST NOT BEAR [A " MAIN 11 INTERSYSTEM GRD. BUS D1 E1 IN 1/2 TO POLE 'Y' / MAIN J2 1 I 0 i N N (FURN w/ POOL TO PNL 'L' 1 i •5 1 Q C9 (OR APPROVED EQ.) ON BOX LID OR SIDES. 1/4 x2 x12" (NEC 250.94) ' _ 8 SOL CU ( ) ,�, z �A 1 X10 s "IN EQUIP, INSTALL D r�POOL BND G ( I � \\\ GRADE AVAILABLE FAULT CURRENT AT THE SECONDARY OF FPL S AERIAL SP CIRC PUMP VAC PACK 3/4 BY EC), ( _rya �.._ N 16 CU (MIN) ) ' //12(G) I RESIN–CAST WATERPROOF 3M — _ _ _ � TRANSF. IS 30, (y) (DATA FURNISHED BY FPL.) ) TYR 2- 112, 684 AMPS s m . IN 112 ❑ SPLICES OR POLARIS BLUE SPLICES CALC'D, AFC AT METER IS <11,000 AMPS(sym). CW INSTALL SURGE PROTECTOR, INSTALL SURGE PROTECTOR NOTE: / (SUITABLE FOR WET t OC). I BASED ON DISTANCES k WIRE SIZE SHOWN. " P i EQ. TO SqD ISDSA3650 AT PANEL, EQ. TO SqD SEE POOL EQUIPMENT AND MECHANICAL _ i�R * AND MAINS SHALL BE RATED A MINIMUM OF 50K AMPS WITH o ?• COMPONENTS SDSA 1175 DRAWINGS FOR LOCATIONS OF ALL • I I 18 MIN. REJECTION CLIPS k CURRENT LIMITING (FLISETRON) FUSES. EQUIPMENT, PUMPS, ETC. WITHIN PANEL 'L' SHALL BE RATED FOR 22,000A s m . z BURIED FOUNDATION 1— EQUIP. GROUNDING CONDUCTO,2 - - - - (Y) �� METAL** STEEL o a "� CWP ( ) A 2- 400 kcml, J1/O (B/), J4/0(N) IN 3" C. MSR CALCS. (PER NEC 430) CRUSHED ROCK AT BOTTOM 9 �' , o 6' B 2- 400 kcml, j1/0, J4/0 IN 2" NIP. 10 HP, 24OV, 30, FLC =,28A (TBL 430.250) OF JUNCTION BOX. '� MIN. 28A x 1,25 = 35A (18 THWN) ' C (SEE PANEL SCHEDULE) 28A x 1.75 = 49 -> 50A DE FUSE (430.52.C) GROUND SERVICE TO FOUND N. STEEL, 5/8 xi0' CU -CLAD GRD. ROD AND METAL D 4-`6,8(G) IN 1" NIP. SPLASH DECK (VAK PACK): Z5 HP, 24OV, 30, FLC = 22A SHEET TITLE C.W.P. (** IF AVAILABLE) ELECTRICAL RISER' 22A x 1.25 28A (10 THWN) CONCRETE HANDHOLE TYP. ( ) N.T.S. D2 3- J8, 11O(G) IN 1" C. 22A x 2.5 2 = 55 –> 60A C.B. 0 ELECTRIC NOTES, O HP, 240V, 10, FLC = 12A (TBL 430.248) (N.T,S,) _ E 4– J2, 16(G) IN 1-1/4" NIP. 12A x 1.25 = 15A 14 THWN SCHEDULES and ENCLOSURES PER NECJ314.30. CONDUCTORS k SPLICES El 4- J21 18(G) IN 1-1/2" C. 12A x 2.5 = 30A C. B. RISERS r---- SHALL BE SUITABLE FOR WET LOCATIONS (314.30(C)) F 4– X12, 112(G) IN 1/2" C. SHEET NUMBER • G 11/0 CU E-1.02 r r