13-749-073
LOUVER SCHEDULE HARDWARE SETS 2: EXTERIOR DOUBLE DOORS @ POOL EQUIPMENT ROOM HARDWARE SET 1: EXTERIOR SINGLE DOOR @ TOILET ROOMS. -OPEN DOOR CLOSERS (QUANTITY DESCRIPTION MODEL NUMBER FINISH DESCRIPTION MODEL NUMBER 4041 EDA X TBMS FINISH 3 EACH HINGES FBB199 4-1/2 X 4--1/2 NRP US26D 1 EACH LOCKSET L9486R X L583-375 06A X EVEREST D 626 1 EACH CLOSER 4041 EDAX TBMS ALUM 1 EACH KICKPLATE 10" X 2" LDW US32D 1 EACH THRESHOLD 2005AT ALUM 1 SET WEATHERSTRIP 290AS LAR ALUM A EACH WALL STOP 1270CVPV US26D DOOR TYPES WINDOW SCHEDULE HARDWARE SET 2: EXTERIOR DOUBLE DOORS @ POOL EQUIPMENT ROOM HINGES (PROVIDE HOLD -OPEN DOOR CLOSERS ON ALL NON—RATED DOORS). L908OR (8)06A X EVEREST D QUANTITY DESCRIPTION MODEL NUMBER 4041 EDA X TBMS FINISH 1 EACH KICKPLATE 10" X 2" LDW US32D 1 EACH 6 EACH HINGES FBB199 4-1/2 X 4-1/2 NRP US32D 2 EACH FLUSHBOLTS 3917 WEATHERSTRIP US26D 1 EACH DUSTPROOF STRIKE 3915 X 3910 346C US26D 1 EACH LOCKSET L908OR (8)06A X EVEREST D 630 2 EACH CLOSER 4041 EDA X TBMS THRESHOLD DETAILS ALUM. 2 EACH KICKPLATE 10" X 2" LDW ALUM US32D 1 EACH THRESHOLD 2005AT ALUM. 2 EACH DOOR SWEEP 315CN 290AS LAR ALUM. 1 SET WEATHERSTRIP 290AS ALUM. 1 EACH DRIP CAP 346C DRIP CAP ALUM. 1 EACH WALL STOP 1270CVPV US26D 3'-0v 3'-0' 9'-0" HARDWARE SET QUANTITY 3: EXTERIOR SINGLE DOOR @ FIRE RATED—ELECTRICAL ROOM. DESCRIPTION MODEL NUMBER FINISH 3 EACH HINGES FBB199 4-1/2 X 4-1/2 NRP US32D 1 EACH LOCKSET L908OR (8)06A X EVEREST D 630 1 EACH CLOSER 4041 EDA X TBMS ALUM 1 EACH KICKPLATE 10" X 2" LDW US32D 1 EACH THRESHOLD 2005AT ALUM 1 EACH DOOR SWEEP 315CN ALUM 1 SET WEATHERSTRIP 290AS ALUM 1 EACH DRIP CAP 346C ALUM 1 EACH WALL STOP 1270CVPV US26D PROVIDE EXIT DEVICE 98L—F FOR ELECTRICAL ROOMS WITH 1200 AMPS OR GREATER. FRAME TYPES .,,..,.t 6'-4" A B C D 0 EXTERIOR DOOR TICKETS / LIFE GUARD'S EXTERIOR DOOR EXTERIOR, IMPACT RESISTANT, MANUAL EXTERIOR M.M. SINGLE TOILETS It ELECTRICAL OFFICE POOL EQUIPMENT ROOM OVERHEAD ROLLING GRILLE CURTAIN DOOR DOOR ROOM A VENDING AREA WINDOW TYPES 0 rt 6'-0" 0 CV 4'-0" LOUVER TYPES ® ( L1 EXTERIOR FIXED ALUM. EXTERIOR SLIDING ALUM. IMPACT RESISTANT WINDOW W/ IMPACT WINDOW W/ IMPACT METAL LOUVER GLAZING GLAZING U EXTERIOR H.M. SINGLE DOOR NOTES :... I... SET 4: EXTERIOR SINGLE DOOR @ LIFE GUARD'S OFFICE. DESCRIPTION MODEL NUMBER _ FINISH www J m 0 B. FLOOR WHERE NO r��w u i • 3 EACH HINGES FBB199 4-1/2 X 4-1/2 NRP US32D 1 EACH LOCKSET L9071 R 06A X EVEREST D 630 MINUTE w 1. REFER TO SHEET A-800 FOR DOOR 45 MINUTE 1—HOUR 1 EACH CLOSER ELEVATION AND FRAME STYLE. ... EXTERIOR — SEVERE EXPOSURE TO FIRE E 45 w • r 1 EACH KICKPLATE 10" X 2" 2. REFER TO SHEET A-810 FOR JAMB AND ww SMOKE �• -45 MINUTE 1—HOUR SMOKE COMPARTMENT THRESHOLD DETAILS 1 EACH THRESHOLD 2005AT ALUM rii• ww a 3. UNDERCUT FOR NON—RATED DOORS 1"CREATIONAL 1 SET WEATHERSTRIP 290AS LAR ALUM iru� MAX. rr D ESIGN AND 4. UNDERCUT NOT PERMITTED AT SMOKE DRIP CAP 346C LAR CONSTRUCTION, INC. IL 3990 North Powerline Road PARTITION OPENINGS. Ft_ Lauderdale, FL 33309 � Voice: 954.566.3885 5. ALL FIRED RATED DOORS AND FRAMES Fax: 954.566.3335 Cr. SHALL BEAR THE LEGIBLE U.L. LABEL. r C7 _ V) E E 6. PROVIDE CLOSER WITH LATCHING DEVICE r d u u V AT ALL TOILET ROOMS AND RATED w ®. ~ u CONDITIONS. C u N w Lu U d 7. CONTRACTOR TO COORDINATE WITH • 3 r ELECTRICAL DRAWINGS FOR ALL SECURITY 0 ".- AND FINAL HARDWARE REQUIREMENTS AND � w > ry N INSTALLATION. J C4 LLI �n M Li J F- Ln �n M0 M w J J LL CC Lu F - N O 0 r , V �N _-. LL J u M M HARDWARE QUANTITY SET 4: EXTERIOR SINGLE DOOR @ LIFE GUARD'S OFFICE. DESCRIPTION MODEL NUMBER _ FINISH A J m 0 B. FLOOR WHERE NO 4—HOUR LSC Q LL Q 2—HOUR 3 EACH HINGES FBB199 4-1/2 X 4-1/2 NRP US32D 1 EACH LOCKSET L9071 R 06A X EVEREST D 630 MINUTE w WALL SEPARATION RATING C 45 MINUTE 1—HOUR 1 EACH CLOSER 4041 EDA X TBMS ALUM EXTERIOR — SEVERE EXPOSURE TO FIRE E 45 MINUTE EXTERIOR — MODERATE EXPOSURE 1 EACH KICKPLATE 10" X 2" LDW US32D SMOKE 0 -45 MINUTE 1—HOUR SMOKE COMPARTMENT IN. 1 EACH THRESHOLD 2005AT ALUM U 1 SET WEATHERSTRIP 290AS LAR ALUM w 1 EACH DRIP CAP 346C LAR ALUM IL � O Z Cr. V r C7 _ w (ts a CV) M r d w ®. 04 w ��a r LO ".- FIRE DOOR AND WINDOW TABLEo —�- •— C Cn • REFER: NEPA 80'— Z W RATINGS w O 0 1. APPENDIX (E) FOR DOOR AND WINDO Q ti O CL LABEL RATING WALL TYPE & RATING A 3—HOUR B. FLOOR WHERE NO 4—HOUR WALL SEPARATION RATING B 2—HOUR 5/8" FOR BUILDERS HARDWARE ONLY 3—HOUR WALL SEPARATION RATING B 90 MINUTE 2—HOUR WALL SEPARATION RATING C 45 MINUTE 1—HOUR WALL SEPARATION RATING D 90 MINUTE EXTERIOR — SEVERE EXPOSURE TO FIRE E 45 MINUTE EXTERIOR — MODERATE EXPOSURE SMOKE SM -20 MINUTE SMOKE WALL SEPARATION SMOKE SM -45 MINUTE 1—HOUR SMOKE COMPARTMENT 0 wwo �O U) LL w ma Cr. CLLu Lu m4:t 0 z J J Q z Z Seal F: s C' D z O r, '� ) 2. TABLE 1-11.4 CLEARANCES (UNDERCUT) TO BOTTOM OF FIRE RATED DOORS .f Atio (ABBREVIATED VERSION BELOW) CLEARANCE BETWEEN w SWINGING DOORS W/ FIRE DOOR OR BUILDERS HARDWARE A. BOTTOM OF DOOR AND RAISED NONCOMBUSTIBLE SILLS 3/8" MAX. B. FLOOR WHERE NO SILL EXISTS 3/4" MAX. C. RIGID FLOOR TILE (NON ---COMBUSTIBLE) 5/8" FOR BUILDERS HARDWARE ONLY D. FLOOR COVERINGS (COMBUSTIBLE) 1 /2" MAX. 3 1-11.2.2 IN BUILDINGS WITH COMBUSTIBLE FLOORS OR COMBUSTIBLE FLOOR w J e Murguido, RA COVERINGS, SPECIAL SILL (THRESHOLD) CONSTRUCTION SHALL BE REQUIRED IF Q g. No- AR -10670 C/) © PROJECT NUMBER COMBUSTIBLE FLOOR CONSTRUCTION SHALL NOT BE PERMITTED TO EXTEND U- 1320MPCP Z w Z L --U u.' F I L E No. :------- MIN RATED FIRE PROTECTION DOOR ASSEMBLIES. F� 1296 TABLE 1-7.4 MAXIMUM AREA OF GLAZING (PER DOOR LEAF) FOR FIRE RATED C DRAWN : X.X_X- GLAZING. CONTRACTOR TO PROVIDE TESTED ASSEMBLIES FOR ALL RATED w REVIEWED : XXX. C 0 w CHECKED : X.X.X. 1-11.2.2 IN BUILDINGS WITH COMBUSTIBLE FLOORS OR COMBUSTIBLE FLOOR d °- COVERINGS, SPECIAL SILL (THRESHOLD) CONSTRUCTION SHALL BE REQUIRED IF Q DATE 07-02-13 THE FLOOR STRUCTURE IS EXTENDED THROUGH THE DOOR OPENING, AS ui ISSUE / REVISIONS COMBUSTIBLE FLOOR CONSTRUCTION SHALL NOT BE PERMITTED TO EXTEND U- - THROUGH THE DOOR OPENING. B Z EXCEPTION: DOOR OPENINGS REQUIRED TO BE PROTECTED BY 20 MIN. OR 30 SQ. IN. MIN RATED FIRE PROTECTION DOOR ASSEMBLIES. F� 1296 TABLE 1-7.4 MAXIMUM AREA OF GLAZING (PER DOOR LEAF) FOR FIRE RATED C D GLAZING. CONTRACTOR TO PROVIDE TESTED ASSEMBLIES FOR ALL RATED Q SQ. CONDITIONS. U 45 MINUTE LABEL RATING MAX. AREA OF GLAZING A 3—HOUR N/A B 2 -HOUR N/A B 90 MINUTE 100 SQ. IN. C 45 MINUTE 1296 SQ. IN. D 90 MINUTE 100 SQ. IN. E 45 MINUTE 1296 SQ. IN. SMOKE SM -20 MINUTE 1296 SQ. IN. SMOKE SM -45 MINUTE 1296 SQ. IN. SHEET TITLE DOOR & WINDOW SCHEDULE Q SHEET NUMBER