Loading...
13-749-041LIFE -SAFETY LEGEND �� -- ILLUMINATED EXIT LIGHT ( > DIRECTION OF TRAVEL) -- FIRE EXTINGUISHER -WALL MOUNTED F.EX FEWC -- FIRE EXTINGUISHER CABINET WALL MOUNTED -- EMERGENCY WALL MOUNTED LIGHT EM.� -- EMERGENCY DISCONNECT - FIRE SIAMESE CONNECTION (WALL OR HYDRANT) -- 2X4 EMERGENCY FLUORESCENT MARK LIGHT FIXTURE -- 1X4 EMERGENCY FLUORESCENT LLJ LIGHT FIXTURE FEC A EMERGENCY FLUORESCENT STRIP H0 LIGHT FIXTURE „� -- EMERGENCY WALL MTD. Q102 FLUORESCENT STRIP LIGHT FIXTURE -- RECESSED EMERGENCY z HIGH HAT LIGHT FIXTURE 1 1- NUMBER OF OCCUPANTS LEAVING 2- REQUIRED WIDTH (inches) 3- PROVIDED WIDTH (inches) I I mem I I m2w 2 -HOUR WALL SEPARATION RATING IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII EXIT PATH ROOM Room Name Top Room NAME Name Bot Room Number RN Program SF/Actual SF SF Life Safety SF Life (#SF/OCCUPANT) Safety SF/Occupants # OCCUPANTS Life Safety Occupants TABLE 602 EXTERIOR NON BEARING WALLS: BUILDING SEPARATION: PROTECTION OF VERTICAL OPENINGS STAIRS PROTECTION OF VERTICAL OPENINGS W MAXIMUM TRAVEL DISTANCE - W UNSPRINKLED cc EGRESS WIDTH PER PERSON: w TABLE 601 0" TO 10'-0" = 1 HOUR RATING 10'-0" > = 0 HOUR RATING N/A N/A 200 FEET TABLE 1015.1) (TABLE 1005.1) 0.2" / PERSON x 340 OCC. = 68" (2) 48" GATES PROVIDED = 96" EIRE FLORIDA BUILDING CODE 2010 MARK Q FLORIDA FIRE PREVENTION CODE GENERAL MULTI- 2A -108C A,B,C LLJ FBC PLUMBING CODE 2010 FEC A 08 .05.13 H0 MAXIMUM TRAVEL DISTANCE TO EXTINGUISHER SHALL NOT EXCEED 75'-0" Q RE: 7-6.3.2.5 (PER F.F.P.C.-'01) Q102 ELECTRICAL CARBON 20 BC B,C BUILDING: ASSEMBLY - GROUP A-5 ROOMS DIOXIDE z SHALL BE REQUIRED WHERE ALL ENERGIZED ELECTRICAL EQUIPMENT CAN BE U Q ENCOUNTERED. RE: 7--6.3.5 (PER F.F.P.C.-'01) MAXIMUM HEIGHT: ACTUAL HEIGHT: 0 55' TOTAL HEIGHT AT UNLIMITED STORIES 13'--9 1/2" ACTUAL HEIGHT AT 1 STORY TOTAL OCCUPANT LOAD - 340 OCC. TYPE OF CONSTRUCTION: TYPE IIB (TABLE 503) z POOL TOTAL AREA: 4,220 SF MALE FEMALE 1 STORY, UNSPRINKLERED: 1,358 SIF SIZE C'3 CMU WALLS WITH STUCCO, PREFABRICATED METAL JOIST WITH METAL DECK ROOF z STRUCTURE 4 2,501 SF - 5,000 SF (REQUIRED) 2 1 OJ BUILDING AREA: 1 D INTERIOR AREA: 1,246 S.F. (ROOMS: 1,111 SF) (WALLS: 204 SF) ❑ EXTERIOR OVERHANGS: 310 SF UNISEX EXTERIOR PATIOS: 6,202 SF FEMALE DETAILED CONSTRUCTION REQUIREMENTS: TABLE 601 W.C. TYPE IIB URINAL W.C. FIRE RESISTANEC RATINGS OF STRUCTURAL MEMBERS: LAVATORY INTERIOR BEARING WALLS: 0 HRS. 1 COLUMNS: 0 HRS. 2 BEAMS: 0 HRS. 3 FLOORS: 0 HRS. U _j ROOF: 0 HRS. EXTERIOR BEARING WALLS: 0 HRS. (NON COMBUSTIBLE) NON BEARING INTERIOR WALLS: 0 HRS. (NON COMBUSTIBLE) TABLE 602 EXTERIOR NON BEARING WALLS: BUILDING SEPARATION: PROTECTION OF VERTICAL OPENINGS STAIRS PROTECTION OF VERTICAL OPENINGS W MAXIMUM TRAVEL DISTANCE - W UNSPRINKLED cc EGRESS WIDTH PER PERSON: w TABLE 601 0" TO 10'-0" = 1 HOUR RATING 10'-0" > = 0 HOUR RATING N/A N/A 200 FEET TABLE 1015.1) (TABLE 1005.1) 0.2" / PERSON x 340 OCC. = 68" (2) 48" GATES PROVIDED = 96" EIRE EXTINGUISHER LEGEND MARK USE TYPE U/L RATING CLASS OF FIRE ❑ GENERAL MULTI- 2A -108C A,B,C Oz PURPOSE PURPOSE FEC A 08 .05.13 H0 MAXIMUM TRAVEL DISTANCE TO EXTINGUISHER SHALL NOT EXCEED 75'-0" RE: 7-6.3.2.5 (PER F.F.P.C.-'01) Q102 ELECTRICAL CARBON 20 BC B,C d.D ROOMS DIOXIDE FFC O SHALL BE REQUIRED WHERE ALL ENERGIZED ELECTRICAL EQUIPMENT CAN BE U Q ENCOUNTERED. RE: 7--6.3.5 (PER F.F.P.C.-'01) NOTE: FIRE EXTINGUISHERS SHALL BE MOUNTED AT MAX HEIGHT OF 48" TO THE TOP OF THE EXTINGUISHER. 1 LIFE SAFETY FLOOR PLAN LS -200 SCALE: 1/41 =1'-0' Cf? 4 2 0 4 8 "�- L�.^I SCALE: 1/4"=l' -O" UNIT OF MEASURE: FEET ZD U LIFE SAFETY NOTES 1. ALL NEW CONSTRUCTION IS CONSIDERED ASSEMBLY OCCUPANCY, TYPE II B CONSTRUCTION 2. ALL NEW CONSTRUCTION, WORK SHALL COMPLY WITH FLORIDA BUILDING CODE 2010 3. MAXIMUM TRAVEL DISTANCE = 20OFT. 4. MAXIMUM DEAD END = 20FT. 5. MAXIMUM CONTINUOUS PATH OF TRAVEL = 75FT. 6. MINIMUM DOOR WIDTH = 32 INCHES 7. ALL EXISTING BUILDING RATINGS SHALL BE MAINTAINED IN CONFORMANCE WITH EXISTING CONDITIONS. ALL AREAS WHERE DISCREPANCIES ARE DISCOVERED DURING CONSTRUCTION SHALL BE REPAIRED. 8. PROVIDE "MAXIMUM OCCUPANCY - XX" SIGN AT ALL LOCATIONS WHERE OCCUPANT LOAD EXCEED 50, SEE LS DRAWINGS, REFER TO LS AND ID DRAWINGS FOR SIGN LOCATIONS. 9. ALL SMOKE DETECTORS IN TOILET ROOMS TO BE TAMPER PROOF. ALL FIRE ALARM DEVICES IN OCCUPIED AREAS AND EXTERIOR TO BE PROVIDED WITH APPROVED PROTECTIVE COVER. 10. NO LOUVERS ARE TO BE PROVIDED IN DOORS AT SMOKE PARTITIONS PER FBC. 11. PROVIDE REQUIRED GASKET AT ALL DOORS IN SMOKE PARTITIONS PER FBC, CH. 7 SECT. 710.5.2. 12, PROVIDE SMOKE DETECTORS IN ALL NON -OCCUPIED SPACES. r RECREATIONAL DESIGN AND CONSTRUCTION, INC. 3990 North Powerline Ror d Ft. Lauderdale, FL 33309 Voice: 954.566.3885 Fax: 954.566.3335 AREA NAME TOTAL S.l S.F. OCC. OCCUPANCY OCC. LOAD EE POOL 4,220 ASSEMBLY 90 ❑ POOL DECK 6,202 30 ASSEMBLY 207 Oz SPLASH DECK 1,062/30 ASSEMBLY 36 X _C V V 08 .05.13 H0 ROOM No. ROOM NAME TOTAL S.F. S.F. OCC. OCCUPANCY OCC. LOAD 101 VENDING AREA 42 100 ASSEMBLY 1 Q102 TICKETS LIFE GUARDS OFFIC 290/100 BUSINESS 3 d.D 103 MALE TOILET 256 ASSEMBLY - ❑ C) 104 UNISEX TOILET 49 ASSEMBLY - U Q 105 FEMALE TOILET 291 ASSEMBLY - (� V 106 POOL EQUIPMENT ROOM 148 100 INDUSTRIAL 1 2 0 107 ELECTRICAL ROOM 40/100 INDUSTRIAL 1 1 c3 TOTAL OCCUPANT LOAD - 340 OCC. PLUMBING FIXTURE CALCULATIONS PER POOL AREA TABLE 424.1.6.1 SWIMMING POOL z POOL TOTAL AREA: 4,220 SF MALE FEMALE 0 SIZE URINAL W.C. LAVATORY W.C. LAVATORY 4 2,501 SF - 5,000 SF (REQUIRED) 2 1 1 5 1 0 J Q 0 AS PER FBC 424.1.6.1.1 FIXTURES SHALL BE PROVIDED AS INDICATED ON TABLE 424.1.6.1. THE FIXTURE COUNT ON THIS CHART IS DEEMED TO BE ADEQUATE FOR THE POOL AND POOL DECK AREA THAT IS UP TO THREE TIMES THE AREA OF THE POOL SURFACE PROVIDED. (POOL DECK IS 7,595 S.F.) 0 z TOTAL PLUMBING FIXTURES PROVIDED Ln UNISEX MALE FEMALE W.C. LAVATORY URINAL W.C. LAVATORY W.C. LAVATORY J a TOTAL PROVIDED 1 1 2 2 3 5 3 SERVICE SINK: 1 PROVIDED (POOL EQUIPMENT ROOM) Cf? 4 2 0 4 8 "�- L�.^I SCALE: 1/4"=l' -O" UNIT OF MEASURE: FEET ZD U LIFE SAFETY NOTES 1. ALL NEW CONSTRUCTION IS CONSIDERED ASSEMBLY OCCUPANCY, TYPE II B CONSTRUCTION 2. ALL NEW CONSTRUCTION, WORK SHALL COMPLY WITH FLORIDA BUILDING CODE 2010 3. MAXIMUM TRAVEL DISTANCE = 20OFT. 4. MAXIMUM DEAD END = 20FT. 5. MAXIMUM CONTINUOUS PATH OF TRAVEL = 75FT. 6. MINIMUM DOOR WIDTH = 32 INCHES 7. ALL EXISTING BUILDING RATINGS SHALL BE MAINTAINED IN CONFORMANCE WITH EXISTING CONDITIONS. ALL AREAS WHERE DISCREPANCIES ARE DISCOVERED DURING CONSTRUCTION SHALL BE REPAIRED. 8. PROVIDE "MAXIMUM OCCUPANCY - XX" SIGN AT ALL LOCATIONS WHERE OCCUPANT LOAD EXCEED 50, SEE LS DRAWINGS, REFER TO LS AND ID DRAWINGS FOR SIGN LOCATIONS. 9. ALL SMOKE DETECTORS IN TOILET ROOMS TO BE TAMPER PROOF. ALL FIRE ALARM DEVICES IN OCCUPIED AREAS AND EXTERIOR TO BE PROVIDED WITH APPROVED PROTECTIVE COVER. 10. NO LOUVERS ARE TO BE PROVIDED IN DOORS AT SMOKE PARTITIONS PER FBC. 11. PROVIDE REQUIRED GASKET AT ALL DOORS IN SMOKE PARTITIONS PER FBC, CH. 7 SECT. 710.5.2. 12, PROVIDE SMOKE DETECTORS IN ALL NON -OCCUPIED SPACES. r RECREATIONAL DESIGN AND CONSTRUCTION, INC. 3990 North Powerline Ror d Ft. Lauderdale, FL 33309 Voice: 954.566.3885 Fax: 954.566.3335 I C) 7—" " (Y) Q 00 LO .E cc,' Q to I r Seal •.*` •� Y G x..2013 Jose M r9uido, RA Re . o. AR -10670 PROJECT NUMBER 1320MPCP FILE No. : EE DRAWN DRAWN REVIEWED: CHECKED X.X.X. X.X.X. X.X.X. i, u u 07-02-13 ISSUE / REVISIONS X _C V V 08 .05.13 FIRE DEPARTM _NT FNTS V V IL H N lL 19 6 3 3 U, �J c3 u 3 U-1 n .- ry N Li 'q M N 0 0 O O I t � I M n V M C M U _j II I C) 7—" " (Y) Q 00 LO .E cc,' Q to I r Seal •.*` •� Y G x..2013 Jose M r9uido, RA Re . o. AR -10670 PROJECT NUMBER 1320MPCP FILE No. : -------- ----_--- DRAWN DRAWN REVIEWED: CHECKED X.X.X. X.X.X. X.X.X. i, D A T E 07-02-13 ISSUE / REVISIONS 08 .05.13 FIRE DEPARTM _NT FNTS SHEET TITLE LIFE SAFFT"" FLOOR PLA;1 I' SHEET NUMBER LS—lulu