13-749-038"77CRT1 AUTOMATIC IRRIGATION SYSTEMS WATER DEMAND REFER TO PLAN WATER SOURCE 2" CITY WATER METER PRESSURE REQUIRED 60 PSI GENERA1 IRRIGATION SHALL BE INSTALLED IN ACCORDANCE WITH LOCAL CODES, CONTRACT DRAWINGS, AND CONTRACT SPECIFICATIONS. ALL IRRIGATION SHALL COMPLY WITH APPENDIX "F" OF THE FLORIDA BUILDING CODE. IRRIGATION DESIGN BASED ON PLANTING PLAN DATED MAY 22, 2013. CONTRACTOR SHALL REFER TO THIS PLAN TO COORDINATE SPRINKLER LOCATIONS AND PIPE ROUTING WITH NEW AND EXISTING PLANT LOCATIONS. THIS IRRIGATION PLAN SHALL BE USED AS A GUIDE ONLY. CONTRACTOR SHALL INSTALL IRRIGATION TO MATCH LANDSCAPING, SIDEWALKS, BUILDINGS, ETC., AND TO OVERCOME THE INHERENT INACCURACIES THAT RESULT WHEN DESIGNING FROM BASE PLANS SCALED AT 1" = 20'. THIS IRRIGATION HAS BEEN DESIGNED AS A TYPICAL BLOCK VALVE TYPE USING RAINBIRD SPRAY AND ROTOR SPRINKLERS, SOLENOID VALVES AND CONTROL SYSTEM. A RAIN SENSOR SHALL BE INSTALLED TO CONSERVE WATER. THE WATER SOURCE SHALL BE A 2" CITY WATER METER. CONTRACTOR IS ADVISED TO STUDY THE PLANS FOR ADDITIONAL INFORMATION AND TO VISIT THE SITE TO BECOME FAMILIAR WITH EXISTING CONDITIONS. TO ENSURE PROPER OPERATION, VALVE SIZES, ZONE CAPACITIES, SPRINKLER SPACING, PIPE AND WIRE SIZES, INSTALLATION NOTES AND DETAILS, AND TECHNICAL SPECIFICATIONS SHALL BE FOLLOWED AS SHOWN. PIPING PIPE ROUTING IS SCHEMATIC ONLY AND SHALL BE ADJUSTED FOR ON SITE CONDITIONS. PIPE SHALL BE INSTALLED IN ACCORDANCE WITH LOCAL CODES AND PIPE MANUFACTURER'S INSTRUCTIONS. PIPE ROUTED UNDER HARDSCAPED AREAS SHALL BE SLEEVED IN SCH 40 PVC. EACH SLEEVE SHALL: (1) BE BURIED TO A MINIMUM DEPTH OF 24", (2) BE TWO PIPE SIZES LARGER THAN THE CARRIER PIPE, AND (3) EXTEND 3 BEYOND HARDSCAPED AREA ON EACH END. CONTRACTOR SHALL VERIFY THE SIZE, DEPTH AND LOCATION OF ALL EXISTING SLEEVES. ALL PIPE INSTALLED ABOVE GRADE AT THE BACKFLOW PREVENTER SHALL BE SCH 40 GALVANIZED STEEL. ALL OTHER PIPE AND FITTINGS SHALL BE SCH 40 PVC. METALIC TAPE SHALL BE INSTALLED ON MAIN LINE AT STRATEGIC POINTS FOR EASY LOCATION. PIPE SIZED TO LIMIT FLOW VELOCITIES TO 5 FEET/SECOND AND TO LIMIT FRICTION LOSS IN THE PIPING NETWORK. PIPE SHALL BE INSTALLED SO BACKFILL DEPTHS ARE MAINTAINED AT 24" FOR MAIN LINE AND LATERALS ROUTED UNDER PAVEMENT, AT 18" FOR MAIN LINE ROUTED IN LANDSCAPED AREAS, AND AT 12" FOR ALL OTHER LATERALS. BACKFILL SHALL BE OF SUITABLE MATERIAL, FREE OF ROCKS, STONES, AND OTHER DEBRIS THAT WOULD DAMAGE IRRIGATION SYSTEM COMPONENTS. A GATE VALVE SHALL BE INSTALLED AT THE SOURCE FOR ISOLATION. EACH GATE VALVE SHALL BE TO LINE SIZE AND INSTALLED IN A VALVE BOX. POROUS MATERIAL SHALL BE INSTALLED PER BOX TO PROMOTE DRAINAGE. FLUSH IRRIGATION SYSTEM WITH WATER TO CLEAR LINES OF FOREIGN MATERIALS AFTER SYSTEM ASSEMBLY IS COMPLETE AND PRIOR TO INSTALLATION OF SPRINKLER HEADS. SEE TECHNICAL SPECIFICATIONS 02810 FOR CLEANING AND PRESSURE TESTING. 5PI31LIKLERS - SPRINKLER LOCATIONS ARE SCHEMATIC ONLY AND SHALL BE ADJUSTED FOR LANDSCAPING, SITE LIGHTING, PREVAILING WIND, MOUNDING, UTILITIES, ETC., TO ENSURE PROPER COVERAGE WITH MINIMAL UNDESIRABLE OVERTHROW. SPRAY HEADS SHALL BE RAINBIRD 1800 SERIES. SIX INCH POP—UP TYPE SHALL BE INSTALLED IN AREAS LANDSCAPED WITH SOD AND MULCH, TWELVE INCH POP—UP TYPE SHALL BE INSTALLED IN AREAS LANDSCAPED WITH GROUNDCOVER AND LOW SHRUBS, AND SHRUB HEADS SHALL BE INSTALLED IN AREAS LANDSCAPED WITH TALL SHRUBS. ALL SPRAY HEADS SHALL BE INSTALLED ON PVC SWING JOINTS CONSISTING OF MARLEX STREET ELBOWS AND SCH 80 NIPPLES. THE RISER FOR EACH SHRUB HEAD AND 12" POP --UP SPRAY LOCATED IN A SHRUB MASS SHALL BE 1/2" SCH 40 PVC WHICH SHALL BE PAINTED FLAT BLACK TO BE LESS VISIBLE. RISERS FOR SHRUB HEADS SHALL BE INSTALLED A STANDARD HEIGHT OF 6" ABOVE PLANTS. TWELVE INCH POP—UP SPRINKLERS LOCATED IN SHRUB MASSES SHALL BE INSTALLED TO THE HEIGHT REQUIRED SO EACH SPRINKLER IS CONCEALED FROM VIEW EXCEPT DURING OPERATION. EACH SPRAY HEAD SHALL BE EQUIPPED WITH THE APPROPRIATE MPR NOZZLE. POP—UP ROTARY HEADS SHALL BE RAINBIRD 5000 PLUS SERIES WHICH SHALL BE INSTALLED ON PRE—FABRICATED 0—RING TYPE PVC SWING JOINTS MANUFACTURED BY LASCO OR APPROVED EQUAL. SPRINKLERS SHALL BE INSTALLED TO AND MAINTAINED AT THE PROPER HEIGHT TO ELIMINATE THE CHANCE OF INJURY TO THE PUBLIC. ADJUSTMENT FEATURES OF SPRINKLERS SPECIFIED SHALL BE UTILIZED TO ENSURE PROPER COVERAGE WITH MINIMAL UNDESIRABLE OVERTHROW LOW ANGLE, FLAT SPRAY, AND ADJUSTABLE ARC NOZZLES SHALL BE USED TO MINIMIZE OVERTHROW. SPRINKLERS LOCATED ADJACENT TO HARDSCAPED AREAS SHALL BE INSTALLED AWAY FROM HARDSCAPED AREAS TO MINIMIZE OVERTHROW AND THE CHANCE OF DAMAGE BY VEHICLES, PEDESTRIANS, AND LAWN MAINTENANCE PERSONNEL. AS A GENERAL RULE, 6" POP—UP SPRAY HEADS SHALL BE INSTALLED IN 4", SHRUB HEADS AND 12" POP—UP SPRAY HEADS SHALL BE INSTALLED IN 12", AND ROTOR HEADS SHALL BE INSTALLED IN 6". CONTROL SYSTEM CONTROL SYSTEM SHALL BE A RAIN BIRD ESP SERIES ELECTRIC TYPE. ONE VALVE SHALL BE CONTROLLED PER STATION EXCEPT AS NOTED. A RAIN SENSOR SHALL BE INSTALLED IN THE SYSTEM TO CONSERVE WATER. CONTROLLER SHALL BE INSTALLED IN ACCORDANCE WITH LOCAL CODES AND MANUFACTURER'S INSTRUCTIONS. PROPER GROUNDING EQUIPMENT SHALL BE PROVIDED. CONTROLLER LOCATION SHALL BE APPROVED BY THE OWNER'S REPRESENTATIVE. A 110 VAC ELECTRIC SOURCE IS REQUIRED PER LOCATION. CONTROL LINES FROM AUTOMATIC CONTROLLER TO IN—LINE AUTOMATIC VALVES SHALL BE #14 AWG DIRECT BURIAL UNDERGROUND FEED TYPE WHICH SHALL BE: (1) INSTALLED IN ACCORDANCE WITH LOCAL CODES, (2) BURIED TO THE DEPTH OF THE MAIN LINE, (3) COLOR CODED TO FACILITATE TROUBLESHOOTING, AND (4) SPLICED MOSTLY AT VALVE LOCATIONS. SPLICES SHALL BE MADE WATERPROOF USING APPROVED METHODS. SPARE WIRES SHALL BE ROUTED FROM THE CONTROLLER IN ALL DIRECTIONS TO THE FARTHEST VALVES CONTROLLED. AN INDIVIDUAL CONTROL WIRE SHALL BE ROUTED TO EACH VALVE AND VALVES WHICH OPERATE SIMULTANEOUSLY SHALL BE TEED TOGETHER AT THE CONTROLLER. AUTOMATIC VALVE LOCATIONS ARE SCHEMATIC ONLY AND SHALL BE ADJUSTED FOR ON SITE CONDITIONS. EACH VALVE SHALL BE INSTALLED IN A VALVE BOX. A MINIMUM OF ONE CUBIC FOOT OF GRAVEL SHALL BE PROVIDED PER BOX TO PROMOTE DRAINAGE. THOSE VALVES WITH PRESSURE REGULATING FEATURE SHALL BE SET AT THE PRESSURE REQUIRED TO ENSURE PROPER OPERATION OF THE SPRINKLERS BEING CONTROLLED. WATER CONSERVATION EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. A RAIN SENSOR SHALL BE PLACED ON A STATIONARY STRUCTURE, MINIMUM OF 5' CLEARANCE FROM OTHER OUTDOOR EQUIPMENT, FREE AND CLEAR OF ANY TREE CANOPY OR OTHER OVERHEAD OBSTRUCTION, AND ABOVE THE HEIGHT OF SPRINKLER COVERAGE. JIMING�AND PRECIPITATION TIMING OF EACH STATION SHALL BE SET IN THE FIELD TO MATCH LOCAL REQUIREMENTS. REFER TO ZONE SUMMARY CHART FOR RECOMMENDED RUN TIMES TO APPLY 1.5 IN/WK. MR PLUS N11= (SIZE PER PUVA NBIE: liMI SPR INWER AT FNMHD /RAGE APPROVED WAKFLL 9•RAY SmomER 9NING ,w LATERAL PIPE LATERAL TEE POP—UP SPRINKLER ON PVC SWING JOINT NOT TO SCALE MPR PLUS NOZZLES (SIZE PER PLAN) NOTE: INSTALL SPRINKLER AT FINISHED GRADE APPROVED BACKFILL NOTE: CONTRACTOR MAY INSTALL PIPE TO SIDE INLET SPRAY SPRINKLER SWING JOINT LAMM PPE LATERAL TEE 12" POP—UP SPRINKLER ON PVC SWING JOINT NOT TO SCALE POP—UP ROTOR INSTALLATION NOT TO SCALE CLEAN BACKFILL SPRINKLER LOCATION DETAIL NOT TO SCALE — — — CLEAN OACKFILL — — — — DEPTH: 12• (2' t SMALLER) r — 19- (2 1/2- & 3-) — — 24- (4- & LARGER) — PVC MAIN UNE — — — -� • CONTROL WIRES �� /J — TRENCHING DETAIL NON—VEHICLE TRAFFIC AREA NOT TO SCALE 4" MAX. PLASTIC VALVE BOX WITH COVER MARKED *IRRIGATION" 112- IN TURF AND 2 IN GROUND COVER AREAS FINISH GRADE —� '' SOLENOID ACTUATED REMOTE CONTROL VALVE 4' x 2-1/4" x i" SOUR BRICK AT EACH CORNER COMMON AND CONTROL WIRES (PROVIDE 24" OF WIRE IN A COIL, EA.) MAINLINE IEA (LE AS NOTEDNOTE: USE 45 ELLS IMMEDIATELY OUTSIDE OF VALVE BOX, AS NECESSARY, FOR TRANSITION TO REQUIRED LATERAL UNE DEPTH. PVC MAIN UNE LLED CONNECTORS LATERAL LINE (COVER AS NOTED IN LEGEND) COMMON WIRE (PROVIDE 24- QF WIRE I A COIL) IN 2 PVC CONDUIT. MAINLINE (COVER AS NOTED IN LEGEND SCH tO PVC NIPPLE REMOTE CONTROL VALVE DETAIL NOT TO SCALE CONCRETE VALVE Box tvmi COVER MARKED GATE VALVE- G�OUMD COVE'.R2" IN FINISH GRADE NOMINAL 4' x 2 1/4' x 4' SOLID BRICK AT EACH CORNER NOTE- USE OTE USE 45 ELLS IMMEDIATELY OUTSIDE OF VALVE BOX, AS NECESSARY, FOR TRANSITION TO REQUIRED MAINLI NE DEPTH. GATE VALVE DETAIL NOT TO SCALE GATE vuvE MVC MALE ADAPTER PVC MAINLINE AS NOTED IN LEGEND) 1 CU. FT. PEA GRAVEL (4" LAYER MINIMUM) 1II11i—CLII{ HOUSING MADE FROM U.V. STABILIZED VALa7{, THEItI[OrLASTIC cLlcx sTor sETxlrrGs— >uEAsvl�E �IeAn�TFALL IN QUANTITIES OF 1/0' To i' �- -ADJUSTABLE DEPTH: tti' (2 1/2" ! SMALLER) 24" (3- 1: 4) 30- (K' & LARGER) CONTROL wmEs TRENCHING DETAIL VEHICLE TRAFFIC AREA NOT TO SCALE EPDXY FI VENTn.ATION HOLES ALUI[III�TTUI[ MOUNTING 1ItACKET `/' O TOTALLY SEALER) k LEAD 1rIItES--- 11EATHEIStIt00F SWITCH O uECFZArTIau (U.L. LISTED) MINI—CLIK II RAIN SENSOR NOT TO SCALE WIRE COLOR CODING CHART STATION � WIRE COLOR 1.11 BLACK 2.12 RED 3 , 13 GREEN 4. 14 YELLOW 5. 15 ORANGE • , 1c BLUE 7 , 17 BROWN i , 1B PURPLE 9 1s POP-UP ROTOR ••• • V Y SHRUB HEAD. • '- SHRU■ MASS V GREY COMMON SHRUB RISER. SPARE PINK • V Y� Y SHRUB MASS. ER • ., ' • MANUFACTURER. GROUNDING ROD INSTALLATION NOT TO SCALE \ / BAR WITH • % POP-UPOF / • 1 • U ELECTRICAL TAPE KS WALK OR ROAD HEAD. • • i u • your• Y Y V • PIPE •• • 'SYVING RISER 3/4' SCH 40 PVC SHRUB RISER LATERAL , it PAINTED MT BLACK ABOVE GRADE SCH 40 PVT: FITTING (TYP) POP—UP ROTOR INSTALLATION NOT TO SCALE CLEAN BACKFILL SPRINKLER LOCATION DETAIL NOT TO SCALE — — — CLEAN OACKFILL — — — — DEPTH: 12• (2' t SMALLER) r — 19- (2 1/2- & 3-) — — 24- (4- & LARGER) — PVC MAIN UNE — — — -� • CONTROL WIRES �� /J — TRENCHING DETAIL NON—VEHICLE TRAFFIC AREA NOT TO SCALE 4" MAX. PLASTIC VALVE BOX WITH COVER MARKED *IRRIGATION" 112- IN TURF AND 2 IN GROUND COVER AREAS FINISH GRADE —� '' SOLENOID ACTUATED REMOTE CONTROL VALVE 4' x 2-1/4" x i" SOUR BRICK AT EACH CORNER COMMON AND CONTROL WIRES (PROVIDE 24" OF WIRE IN A COIL, EA.) MAINLINE IEA (LE AS NOTEDNOTE: USE 45 ELLS IMMEDIATELY OUTSIDE OF VALVE BOX, AS NECESSARY, FOR TRANSITION TO REQUIRED LATERAL UNE DEPTH. PVC MAIN UNE LLED CONNECTORS LATERAL LINE (COVER AS NOTED IN LEGEND) COMMON WIRE (PROVIDE 24- QF WIRE I A COIL) IN 2 PVC CONDUIT. MAINLINE (COVER AS NOTED IN LEGEND SCH tO PVC NIPPLE REMOTE CONTROL VALVE DETAIL NOT TO SCALE CONCRETE VALVE Box tvmi COVER MARKED GATE VALVE- G�OUMD COVE'.R2" IN FINISH GRADE NOMINAL 4' x 2 1/4' x 4' SOLID BRICK AT EACH CORNER NOTE- USE OTE USE 45 ELLS IMMEDIATELY OUTSIDE OF VALVE BOX, AS NECESSARY, FOR TRANSITION TO REQUIRED MAINLI NE DEPTH. GATE VALVE DETAIL NOT TO SCALE GATE vuvE MVC MALE ADAPTER PVC MAINLINE AS NOTED IN LEGEND) 1 CU. FT. PEA GRAVEL (4" LAYER MINIMUM) 1II11i—CLII{ HOUSING MADE FROM U.V. STABILIZED VALa7{, THEItI[OrLASTIC cLlcx sTor sETxlrrGs— >uEAsvl�E �IeAn�TFALL IN QUANTITIES OF 1/0' To i' �- -ADJUSTABLE DEPTH: tti' (2 1/2" ! SMALLER) 24" (3- 1: 4) 30- (K' & LARGER) CONTROL wmEs TRENCHING DETAIL VEHICLE TRAFFIC AREA NOT TO SCALE EPDXY FI VENTn.ATION HOLES ALUI[III�TTUI[ MOUNTING 1ItACKET `/' O TOTALLY SEALER) k LEAD 1rIItES--- 11EATHEIStIt00F SWITCH O uECFZArTIau (U.L. LISTED) MINI—CLIK II RAIN SENSOR NOT TO SCALE WIRE COLOR CODING CHART STATION � WIRE COLOR 1.11 BLACK 2.12 RED 3 , 13 GREEN 4. 14 YELLOW 5. 15 ORANGE • , 1c BLUE 7 , 17 BROWN i , 1B PURPLE 9 1s INSTALL SPRINKLER 1/2' BELOW GRADE CLEAN FILL POP-UP ROTOR Pvc s'anNc JOINT LATERAL PIPE uiarAl. TEE ROTOR ON PVC SWING JOINT NOT TO SCALE POP—UP SPRAY SCH 40 PVC RISER \ l SHRUB MASS POP—UP SPRAY IN SHRUB MASS NOT TO SCALE ri W,,.H •IY.wAL «N.RMN . BBVER S/B' DIAMETER •• COPPER CLAD ROD. RESISTANCE TO EARTH ''" � -• SHALL BE WITHIN LIMITS SET BY CONTROLL A ••• • V Y • Y • • 4 TAN 10.20 GREY COMMON WHITE SPARE PINK INSTALL SPRINKLER 1/2' BELOW GRADE CLEAN FILL POP-UP ROTOR Pvc s'anNc JOINT LATERAL PIPE uiarAl. TEE ROTOR ON PVC SWING JOINT NOT TO SCALE POP—UP SPRAY SCH 40 PVC RISER \ l SHRUB MASS POP—UP SPRAY IN SHRUB MASS NOT TO SCALE ri W,,.H •IY.wAL «N.RMN . BBVER S/B' DIAMETER •• COPPER CLAD ROD. RESISTANCE TO EARTH ''" � -• SHALL BE WITHIN LIMITS SET BY CONTROLL A FOX CPOCURTIS * ROGERS DE SIGN STUDIO INC Landscape Architecture 3250 MARY STREET, SUITE 301 COCONUT GROVE, FLORIDA 33133 305.442.1774 / 305.445 489 FAX www.curtisrogers.com LIC. LC C 0 0 0 2 41 U ••• • V Y • Y • • 4 • Y • Y Y • V Y� Y ER • ., ' • MANUFACTURER. GROUNDING ROD INSTALLATION NOT TO SCALE CPOCURTIS * ROGERS DE SIGN STUDIO INC Landscape Architecture 3250 MARY STREET, SUITE 301 COCONUT GROVE, FLORIDA 33133 305.442.1774 / 305.445 489 FAX www.curtisrogers.com LIC. LC C 0 0 0 2 41 U fn Ono V Z r O U v U B wla f% C KCi'11 1UIVAL. D ESIGN AND CONSTRUCTION, INC. 3990 North Powerline Road Ft. Lauderdale, FL 33309 Voice: 954.566.38155 Fax: 954.566.3335It s s u v V V N LLi O w W i N N J F 0 m: U to _ M tail F_ - � o0 J _— M M 11. LU = � r � •o LL � N L4 ..N T M J N � W � IRA L2 N of Cr 0 LL 0 co z 0 C4) 4— m < LU M 0 III LL do CL L0 I L RD Q LL W x. r LL. 0 i a U z a W � M O a CG r � •� co r � coV. Ld C O CL w m z J s d z U ZF Ci LU LL K Seal , Z ° PROJECT � NUMBER � 1320MPCP U W FILE No. -------- 0 � DRAWN J.P. REVIEWED: A.C. D°c CHECKED A.C. a Z) DATE 07-02-13 r ISSUE /REVISIONS J W W d 2 r SHEET TITLE IRRIGATION NOTES AND DETAILS SHEET NUMBER Rm2 ••• • V Y • Y • • 4 • Y • Y Y • V Y� Y • • Y• 4 • •C • 1 • U J G • • • i u • your• Y Y V • V Z r O U v U B wla f% C KCi'11 1UIVAL. D ESIGN AND CONSTRUCTION, INC. 3990 North Powerline Road Ft. Lauderdale, FL 33309 Voice: 954.566.38155 Fax: 954.566.3335It s s u v V V N LLi O w W i N N J F 0 m: U to _ M tail F_ - � o0 J _— M M 11. LU = � r � •o LL � N L4 ..N T M J N � W � IRA L2 N of Cr 0 LL 0 co z 0 C4) 4— m < LU M 0 III LL do CL L0 I L RD Q LL W x. r LL. 0 i a U z a W � M O a CG r � •� co r � coV. Ld C O CL w m z J s d z U ZF Ci LU LL K Seal , Z ° PROJECT � NUMBER � 1320MPCP U W FILE No. -------- 0 � DRAWN J.P. REVIEWED: A.C. D°c CHECKED A.C. a Z) DATE 07-02-13 r ISSUE /REVISIONS J W W d 2 r SHEET TITLE IRRIGATION NOTES AND DETAILS SHEET NUMBER Rm2