13-749-0151. ALL MATERIALS AND LABOR UNDER THIS PROJECT SHALL BE IN STRICT ACCORDANCE WITH THE REQUIREMENTS OF THE MIAMI-DADE WATER AND SEWER DEPARTMENT AND SHALL CONFORM TO THE STANDARDS AND SPECIFICATIONS AVAILABLE AND ON FILE WITH THE DEPARTMENT. SUBUI SHOP DRAWINGS FOR ALL MATERIALS. 2, COVER OVER WATER OR SEWER FORCE MAINS SHALL BE 4'-0' MIN. 3. ALL MAIN LINE VALVES SHALL BE INSTALLED COMPLETE WITH 10" RISER PIPES AND NO. 3 OR 53 VALVE BOXES FIRE HYDRANTS AND SERVICE VALVES SHALL BE INSTALLED COMPLETE WITH 6" RISER PIPES AND NO. 2 VALVE BOXES. 4. ALL FORCE MAIN SERVICE CONNECTIONS INTO PRESSURE TRANSMISSION MAINS SHALL FIVE A SHUT OFF VALVE AND CHECK VALVE AT THE POINT OF ENTRY. 5. ALL GRAVITY SYSTEMS SHALL BE CONSTRUCTED IN ACCORDANCE WITH DEPARTMENT STANDARDS. 6. ALL WATER METERS WILL BE INSTALLED BY THE MIAMI-DADE WATER AND SEWER DEPARTMENT PROVIDING THE APPROPRIATE CHARGES HAVE BEEN PREPAID. 7. FIRE HYDRANT REQUIREMENTS (NUMBER AND LOCATION) SHALL BE AS REQUIRED BY THE MIAMI-DADE COUNTY FIRE DEPARTMENT OR THE APPROPRIATE FIRE AGENCY WITH INSTALLATION IN ACCORDANCE WITH DEPARTMENT STANDARDS. i. CONTRACTOR MUST CALL M-•DWASD INSPECTION DIVISION TO ARRANGE FOR A PRECONSTRUCT10N MEETING 2 FULL BUSINESS DAYS PRIOR TO PROPOSED START OF CONSTRUCTION. CONTACT ONE CALL CENTT]t 48 HRS PRIOR TO EXCAVATION.' 9. CONTRACT INSPECTOR WILL INSPECT ANY FACILITIES APPROVED BY THE DEPARTMENT. ALL OTHER REQUIREMENTS OF THE PERMITTING AGENCY SHALL BE IN ACCORDANCE WITH THEIR STANDARDS AND REQUIREMENTS. 10. WORK PERFORMED UNDER THIS PROJECT WILL NOT BE CONSIDERED AS COMPLETE UNTIL FINAL ACCEPTANCE OF THE SYSTEM BY THE DEPARTMENT AND UNTIL THE FOLLOWING DOCUMENTS ARE RECEIVED AND APPROVED BY THE DEPARTMENT. a. EASEMENTS, IF REQUIRED. b. CONTRACTOR'S WAIVER AND RELEASE OF LIEN. c. ABSOLUTE BILL OF SALE. d. L. CONTRACTOR'S LETTER OF WARRANTY (I.E., LETTER AGREEMENT). Li. DEVELOPER'S CONTRACT BOND (I.E., CONTRACT AGREEMENT). e. 'AS -BUILT• PRINTS 24706" SHOWING SPECIFIC LOCATIONS, DEPTH, ETC. OF ALL WATER AND SEWER FACILITIES AS LOCATED BY A LICENSED FLORIDA SURVEYOR, ALONG WITH PRINTS OF "AS -BUILT" WHICH HAVE BEEN SIGNED AND SEALED BY A REGISTERED SURVEYOR. (No. OF PRINTS: 3 -FOR WATER, 4 -FOR GRAVITY SEWER AND 5 -FOR FORCE MAIN OR PUMP STATION PROJECTS). THE DEPARTMENT RESERVES THE RIGHT TO REQUIRE SUBMITTAL ON ELECTRONIC MEDIA IN ACCORDANCE WITH SEC. 01775 "MAGNETIC MEDIA SUBMITTAL'. f. H.R.S. LETTER OF RELEASE REQUIRED FOR ALL WATER PROJECTS. g. BILL OF SALE SKETCH (IWx117 FOR WATER AND SEWER, SEPARATELY. 11. ALL NEW CONNECTIONS FROM EXISTING DEPARTMENT MAINS TO BE MADE BY DEPARTMENT FORCES ONLY. THE CONTRACTOR TO EXCAVATE AT REQUIRED LOCATIONS, PROVIDE AND INSTALL MATERIAL WITH FITTINGS, PRIOR TO TAP. 12. AN APPROVED PAVING AND DRAINAGE PLAN MUST BE SUBMITTED TO MDWASD FOR ALL NEW SUBDIVISIONS PRIOR TO APPROVAL OF WATT! AND SEWER PERMIT PLANS, UPON REQUEST. 13. UNLESS OTHERWISE SPECIFIED, ALL TAPS 20 INCHES AND SMALLER FOR CONNECTIONS TO EXISTING MAINS WILL BE DONE BY DEPARTMENT FORCES. UNDER NO CIRCUMSTANCES WILL THE CONTRACTOR BE PERMITTED TO TAP EXISTING MAINS IN THE SIZE RANGE SPECIFIED ABOVE. THE TAPPING SLEEVE AND TAPPING VALVE ARE FURNISHED AND INSTALLED BY THE CONTRACTOR UNDER THE SUPERVISION OF THE INSPECTOR. I T E M CROSS I SPEC. REF. REF. §29 -nu APPRO)EDB'Y STANDARD DETAIL 03/01/2010 v.F.c. GS MIAMI•STANDARD REQUIREMENTS DADE 0 • mm WATER AND SEWER f-yV" CONSTRUCTION SHEET 1 OF 2 1. AT THE COMPLETION OF ANY WATER AND SEWER JOB, EITHER DONATION OR CONTRACT, THE CONTRACTOR SHALL SUBMIT: a. AS -BUILT PRINTS WHICH HAVE BEEN SIGNED AND SEALED BY A FLORIDA LICENSED PROFESSIONAL SURVEYOR AND MAPPER. (QTY. OF PRINTS, AS REQUIRED BY THE DEPARTMENT.) 2. "AS -BUILT" FORMAT: a. 24"06" PRINTS b. LOCATION MAP SCALE SHOULD BE 1"=300' AND SECTION -TOWNSHIP -RANGE SHOULD BE SHOWN. c. THE WORD "AS -BUILT" IN LARGE LETTERS. d. TITLE BLOCK WITH DEPARTMENT DS, DW OR FR NUMBER AND PERTINENT INFORMATION. e. PREFERRED SCALE TO BE 1"= 40' HORIZONTALLY AND I"= 4' VERTICALLY*. f. STREET NOMENCLATURE. g. SEPARATE AS-BUILTS FOR WATER AND SEWER. h. SEPARATE WATER AND SEWER PROFILE. i. STATIONING STARTING WITH 0+00 AT PERMANENT REFERENCE POINT (I.E., ETC.) OR AS SHOWN ON DESIGN PERMIT PLANS, AND TO RUN CONTINUOUSLY TO END OF MAIN. j. EASEMENTS, IF ANY, TIED TO PERMANENT REFERENCE POINT. k. IDENTIFY ALL CONTROL LINES (I.E. BLDG. LINE, PROPERTY LINE, R/W; ETC). I. ALL "PROPOSED" INFORMATION TO BE REMOVED FROM PRINTS, LEAVING ONLY "AS -BUILT" INFORMATION REFLECTED IN DRAWINGS, 3. WATER "AS-DUILTS" MUST INCLUDE: a. PLANS SHOWING PIPE SIZE, MATERIAL AND OFFSET OF MAIN, DEFLECTIONS (IF ANY), STATION OF SERVICES, HYDRANTS AND FITTINGS AT THE MAINLINE: (IF PERPENDICULAR TO IT), AND AT MAIN AND END OF SERVICES IF ANY, OTHER ANGLE, AND DEFLECTION OF PIPE, IF ANY. b. PROFILE SHOWING TOP OF GROUND AND TOP OF PIPE ELEVATIONS AT EVERY 100' STATION AND AT ANY CHANGE IN GRADE (WITH CORRESPONDING STATION), PIPE SIZE AND PIPE MATERIALS REFERENCED TO PUN. 4. SEWER "AS-BUILTS" MUST INCLUDE: a. PLAN SHOWING MANHOLE NUMBER, PIPE SIZE AND PIPE MATERIAL OF PIPE, DEFLECTION, IF ANY (FORCE MAIN ONLY), AND LOCATION OF LATERALS WITH REFERENCE TO MANHOLE. b. PROFILE SHOWING MANHOLE NUMBER AS PER PUN), RIM AND INVERT ELEVATIONS (IF MORE THAN ONE INVERT, LABEL NORTH, SOUTH , ETC), AND STATION STARTING AT EACH 0+00 AT DOWNSTREAM MANHOLE. 5. FORCE MAIN "AS -BUILT" SAME AS WATER MAIN ABOVE. 6, EACH AS-DUILT SHALL SHOW THE FLORIDA STATE PLANE COORDINATES (CURRENT READJUSTMENT) OF ALL THE MANHOLES AND VALVES AND OF AT LEAST TWO HORIZONTAL CONTROL POINTS PROPERLY IDENTIFIED AND LOCATED WITHIN THE PROJECT. * OTHER SCALE MAY BE PERMITTED, LUT MUST BE APPROVED MY THE DEP OF DRAWINGS. ITEM CROSS SPEC. REF. REF. ISSUE DATE APPROVED BY S T A N D A R D D E T A I L GS 03/11/2009 V.F.C. MI®DADS 0.5 "AS -BUILT" REQUIREMENTS v,a-,-rvor SHEET 2 OF 2 WATER 1t SEWER DEPARTMENT -4 Ln Ln STA 2+86.8 lz-- O O + Q N O O O PROPOSED 6" C-900 PVC SANITARY LATERAL DEPARTMENT OF HEALTH (NOT PART OF M-DWASD NOTES OR APPROVAL) WATER MAIN HORIZONTALS P�QN 1. SEPARATIONS SHALL BE MEASURED OUTSIDE EDGE TO OUTSIDE EDGE, 2. BETWEEN WATER MAINS AND STORM SEWERS, STORMWATER, FORCE MAINS, OR RECLAIMED WATER LINES, SHALL BE 3 FT. MINIMUM. 3, BETWEEN WATER MAINS AND VACUUM TYPE SEWER PREFERABLY 10 FT, AND AT LEAST 3 FT. MINIMUM. 4. GRAVITY OR PRESSURE SANITARY SEWERS, WASTEWATER FORCE MAINS OR RECLAIMED WATER PREFERABLY 10 FT, AND AT LEAST 6 FT. MAY BE REDUCED TO 3 FT. WHERE BOTTOM OF WATER MAIN 15 AT LEAST 6 INCHES ABOVE TDP OF SEWER, 5. 10 FT. MINIMUM TO ANY PART OF ON-SITE SEWER TREATMENT OR DISPOSAL SYSTEM. WATER MAIN L/fRTICAL SEPARAT►0N5 1. SEPARATIONS BETWEEN WATER MAINS AND GRAVITY SEWER, VACUUM TYPE SEWER, OR STORM SEWERS TO BE PREFERABLY 12 INCHES OR AT LEAST 6 INCHES ABOVE. OR AT LEAST 12 -INCHES IF BELOW.* 2, PRESSURE SANITARY SEWER, WASTEWATER, OR STORMWATER FORCE MAIN, OR RECLAIMED WATER, ATEL AS -T 12 INCHES ABOVE OR BELOW. *NOTE: CENTER ONE FULL LENGTH OF WATER MAIN PIPE AT CROSSINGS; ALTERNATIVELY ARRANGE PIPES SO JOINTS ARE AT LEAST 3 FEET FROM JOINTS IN VACUUM, STORMWATER, OR STORMWATER FORCE MAINS. AT LEAST 6 FEET FROM JOINTS IN GRAVITY OR PRESSURE SEWERS, WASTEWATER FORCE MAINS, OR RECLAIMED WATER MAINS. ALL WATER MAINS 24 INCHES IN DIAMETER OR LESS, SHALL BE BLUE IN COLOR OR HAVE A 2 INCH WIDE BLUE STRIPE PAINTED ALONG THE CENTERLINE OF THE PIPE. 0 20' 40' HORIZONTAL SCALE: 1"=20'-O' 0 21 4' VERTICAL SCALE: 1 "=2'-0" STA 3+89.1 16 II O I O I O 14 __---�-�_ I 1121= Iv INV 12 197 I FINISHED GRADE r. /-1 /.l 7.0' I PROP. 12" AI.P! WM-I T.O.P. EL=+7.35' 2* MAX l [Al 141 121 UI EXIST (2)-4" COMMUNICATIONS LINES (TO ME FIELD VERIFIED) 10 i• V m EXIST 6" C.L WY " I (TO IE FIELD VERIFIED) I 0/S 7.64' L PROP! i x12" VERTICAL OFFSET 2' MAX. DEFLECTION EXIST d" V.C. SAN, SEWER INV EL=+3.16" I I I I I I I L �I Z�I 16 REVIEWED: 31I vi vi vi CHECKED : e b q O O 07-02-13 W ti a z I 14 -------_-_______ _ _ _.___II _ 14 PROP. 5.0' 20 0'-uW --- -R/W DEDICATION O a FINISHED GRADE -2.5' I _ 12 12 _ _- ---_ 11.5 I =0.9 PROP 6" CLEANOUT 10 _- , ___.__ ____.____�_____ �____.___..___�___-_-------_--____ 10 EXIST (2)-4 COMMUNICATIONS LINES (TO BE FIELD VERIFIED) -- _ EXIST. 6" C.t WY TO BE ABANDONED IN PLACE m _(TO BE FIELD VERIFIED) Q PROP! 12" D.IP. WY LO.P. EL=4,00' I I 6 AMOR. 6-45* CONT. TO NUILD/NG VERTICAL SENDrP". EXIST. d" V.C. SAN. SEWER 1.E=+2.14' /W /W EL I R/W=+4.61' CLEANOUT INV EL=+4.63' OF 6" C_900 PROP. 6" SDR -35+ O #.1,FT SLOpEI CONT. TO BUILDING 2 I I w L� 0 v MDWAISD PRIVATE ('j .. SERY lz-- O O + Q N O O O PROPOSED 6" C-900 PVC SANITARY LATERAL DEPARTMENT OF HEALTH (NOT PART OF M-DWASD NOTES OR APPROVAL) WATER MAIN HORIZONTALS P�QN 1. SEPARATIONS SHALL BE MEASURED OUTSIDE EDGE TO OUTSIDE EDGE, 2. BETWEEN WATER MAINS AND STORM SEWERS, STORMWATER, FORCE MAINS, OR RECLAIMED WATER LINES, SHALL BE 3 FT. MINIMUM. 3, BETWEEN WATER MAINS AND VACUUM TYPE SEWER PREFERABLY 10 FT, AND AT LEAST 3 FT. MINIMUM. 4. GRAVITY OR PRESSURE SANITARY SEWERS, WASTEWATER FORCE MAINS OR RECLAIMED WATER PREFERABLY 10 FT, AND AT LEAST 6 FT. MAY BE REDUCED TO 3 FT. WHERE BOTTOM OF WATER MAIN 15 AT LEAST 6 INCHES ABOVE TDP OF SEWER, 5. 10 FT. MINIMUM TO ANY PART OF ON-SITE SEWER TREATMENT OR DISPOSAL SYSTEM. WATER MAIN L/fRTICAL SEPARAT►0N5 1. SEPARATIONS BETWEEN WATER MAINS AND GRAVITY SEWER, VACUUM TYPE SEWER, OR STORM SEWERS TO BE PREFERABLY 12 INCHES OR AT LEAST 6 INCHES ABOVE. OR AT LEAST 12 -INCHES IF BELOW.* 2, PRESSURE SANITARY SEWER, WASTEWATER, OR STORMWATER FORCE MAIN, OR RECLAIMED WATER, ATEL AS -T 12 INCHES ABOVE OR BELOW. *NOTE: CENTER ONE FULL LENGTH OF WATER MAIN PIPE AT CROSSINGS; ALTERNATIVELY ARRANGE PIPES SO JOINTS ARE AT LEAST 3 FEET FROM JOINTS IN VACUUM, STORMWATER, OR STORMWATER FORCE MAINS. AT LEAST 6 FEET FROM JOINTS IN GRAVITY OR PRESSURE SEWERS, WASTEWATER FORCE MAINS, OR RECLAIMED WATER MAINS. ALL WATER MAINS 24 INCHES IN DIAMETER OR LESS, SHALL BE BLUE IN COLOR OR HAVE A 2 INCH WIDE BLUE STRIPE PAINTED ALONG THE CENTERLINE OF THE PIPE. 0 20' 40' HORIZONTAL SCALE: 1"=20'-O' 0 21 4' VERTICAL SCALE: 1 "=2'-0" STA 3+89.1 16 II O I O I O 14 __---�-�_ I 1121= Iv INV 12 197 I FINISHED GRADE r. /-1 /.l 7.0' I PROP. 12" AI.P! WM-I T.O.P. EL=+7.35' 2* MAX l [Al 141 121 UI EXIST (2)-4" COMMUNICATIONS LINES (TO ME FIELD VERIFIED) 10 i• V m EXIST 6" C.L WY " I (TO IE FIELD VERIFIED) I 0/S 7.64' L PROP! i x12" VERTICAL OFFSET 2' MAX. DEFLECTION EXIST d" V.C. SAN, SEWER INV EL=+3.16" I I I I I I I -------- 1 J.A.O. REVIEWED: H.J.N. CHECKED : e b DATE 07-02-13 W ti 1 � I q O a O o •d o b O N N a N O -I- t (n + + + O O O O PROPOSED 6" D.I.P. WM 3 m 21 a �� i LU O O 1- 1- U3 O D I Y W • t • _ • • J '...R��;�?EATIONAL D ESIGN AND CONSTRUCTION, INC. 3990 North Powerline Road Ft. Lauderdale, FL 33309 Voice: 954.566.38135 Fax: 954.566.3335 WS � 3 F # 3 n 0 M M MI 00 M M U � U M N A NL1C �I� N < 2 cc W zCc Cn Q Q.Wa.jCN *3 U.con cl) Cn 2 . 0 0M 0 CL D n Cl) a c�e�icLr�IsrzE �i2LS,i2CYL 4::-AiS.OG'CQtE11 -q)2 c. LAND SURVEYORS CIVIL ENGINEERS LAND PLANNERS LD#87 CA#87 3240 CORPORATE PrAY MIRAMAR, FL 53025 TEL: (305)652-7010 FAX: (r3.Q5� 52-8284 sew f �N �N ,35 t .. f: ';• AE IF [' � 4 FL -Reg .,No: 60635 PROJECT NUMBER '1320MPCP FILE No. -------- DRAWN : J.A.O. REVIEWED: H.J.N. CHECKED : H.J.N. DATE 07-02-13 ISSUE / REVISIONS THIS Dk^WING IS TIHE INTELLECTUAL PI SHEET TITLE WATER & SEWER NOTES & PROFILES SHEET NUMBER_