13-749-00441
i Y
CITY OF SOUTH MIAMI
.77
t,�, •, y ��, }y � 3 : Fry � .��h'
APPLICATION FOR APPROVAL OF SWIMMING POOL PLANS
This form is to be completed and submitted with plans and specifications in six copies along with the appropriate fee.
New Construction ❑_ Revision ❑_ Modification ❑�
1. Name of Agent or Applicant: MURRAY PARKA UATIC CENTER INTERACTIVE WATER FEATURE
Address of Pool 6701 SW 58'" PLACE City CITY OF SOUTH MIAMI FLORIDA 33143 County MIAMI-DADE
2. Name of Owner CITY OF SOUTH MIAMI Phone Number (305) 403-2072
Mailing Address 6130 SUNSET DRIVE City SOUTH MIAMI State FL Zip 33143
3. Pool Type: Conventional ❑ Spa ❑ Wading ❑ Special Purpose ❑ Water Recreation Attraction®
Indoor ❑ Outdoor ®_Transient ® Non -transient❑
4. No. of Units Served: NIA No. of Stories Distance of Farthest Unit from Pool: Elevator: Yes❑ No❑_
5. Number of Sanitary Facilities:
Distance From
Pool: 115 LF
6. Method of Waste Water Disposal: STORM DRAINAGE SYSTEM
7. Collector Tank Volume in Gallons: 1,500 Bathing Load: 22 Water Source: MDWASA
8. Dimensions: Width: 39'-5" Length: 44'-8" Area: 1,063 SF Perimeter: 138 LF Depth: Max. 0'-0" Min. 0'-0" Shape: GEOMETRIC
9, Type Construction Material: Shell CONCRETE Finish SMOOTH FINISH Color: LIGHT IN COLOR
10. Equipment Make and Model:
(A) Recirculation Pump: PENTAIR WHISPERFLO WFE-8 Flow: 112.00 GPM At: 60 TDH 2 HP
(B) Filter: NATIONAL 36" FRP SAND FILTER UNIT Area 7.2 Sq. Ft. Flow Capacity 144.00
(C) Filter System Disinfection Equipment: PULSAR I CALCIUM HYPOCHLORITE FEE
(PPD) RDER Capacity 120
(D) Filter System PH Adjustment Feeder: STENNER 85M5 ACID FEEDER Capacity 15 (GPD)
(E) Feature Pump: PENTAIR EQK750 Flow: 380 GPM At: 25 TDH 7.5 HP
(G) System UV Sanitation System: MODEL GH SP -25-6 (LAMP POWER 1 x 2.5 Kw. FLOW 365 GPM)
(H) Test Kit: TAYLOR # 2000-5 DUPLEX