Loading...
09-97-055rrnnn r.rrnn n2ia MTnllf uvvu HOOD NO. aa.r va•a.arr++v•- MODEL LENGTH MAX, COOKING TEMP, EXHAUST PLENUM SUPPLY PLENUM HOOD CONSTRUCTION HOD CON IG. TOTAL EXH. CFM RISER(S) TOTAL RISERS) END ENDO ROW I H NG. DIA. CFS.P. SUP, CFM W DTH G, DIA. CFM S.P. 1 6624 VHB-PSP-F 7' 6,00'Non. 7' 6.00'OD 700 Deg, 1125 14' 1125 -0,112' 900 NO. 2 Incandescent Light Fix 430 SS 100% ALONE N/A NO 2 5424 VHB-PSP-F 6' 0,00'Nom. 6' 0.00'OD 700 Deg, 900 12' 900 -0,105' 720 C AREA OF EXHAUST FAN (ASSUME FLAT SURFACE AS WORST CASE) - 11.66 SQ. FT. 430 SS 100% ALONE N/A NSAU1-G10 nuuu jvr urcna j vry FILTER(S) LIGHT(S) UTILITY CAHINET<S> FIRE HOOD HOOD N0. TYPE QTY HEIGHT LENGTH WIRE QTY TYPE GUARD L L LOCATION T P SIZ MOD L # QUANTITY LOCAT ON SYSTEM PIPING WEIGHT I NONE WIDTH LENG. DIA. CFM S.P. 1 Front 3 Incandescent Light Fix NO 8' 16' 450 0,074' H.P. NO 328 LBS. 2 NONE FAN UNIT MODEL # NO. 2 Incandescent Light Fix NO NO 253 LBS, i'Jaiaarfl f/YaU�V //JJA-JRaLYp.!(/.YJ 12 1 Front 1 72' 1 12' 1 6' 1 6' I 24' I I /du i u,uy,- i rtu� tauvuiunaava� EXHAUST FAN SUPPLY FAN FAN HOODRISER(S) POS. LENGTH WIDTH HEIGHT NO, H.P. # VOLT WIDTH LENG. DIA. CFM S.P. 1 Front 90' 12' 6' 8' 1 16' 1450 0,074' 8' 16' 450 0,074' 12 1 Front 1 72' 1 12' 1 6' 1 6' I 24' I I /du i u,uy,- i rtu� tauvuiunaava� EXHAUST FAN SUPPLY FAN FAN E MODEL TAG CFM S,P, RPM H.P. # VOLT FLA BLOWER HOUSING TAG CFM S.P. RPM H.P. 0 VOLT FLA UNIT FAN UNIT MODEL # NO. _Tf FOR SCREWS HOLDING FAN TO �WRIB EXHAUST FAN DIMENSIONS - 46 DIA. x 36.5" HIGH - 190 LBS A CENTROID OF EXHAUST FAN ABOVE CURB - 21" B AS PER ASCE 7-02 AND FBC 33 LBS./SQ.FT. C AREA OF EXHAUST FAN (ASSUME FLAT SURFACE AS WORST CASE) - 11.66 SQ. FT. D MOMENT ON FAN APPLIED BY WIND I NSAU1-G10 A x B x C x 1.5 (SAFETY FACTOR) = 1.5 x 33 x 11.66 x 1.75 = 1010 LB -FT E) SUM MOMENTS TO FIND SHEAR FORCE ON SCREW GIO NSAU.1 1620 0.400' 733 0,750 1 115 12.0 2 DU85HFA DU85HFA 2025 - 0.700 1278 0,750 1 115 13.0 G MOMENT ON CURB APPLIED BY WIND E x F X B x 1.5 = 0.833 x 4.125 x 33 x 1.5= 170 LB -FT UNISTRUT HANGING ANGLE DETAIL 1/2' DIA. ALL THREAD ROD CONNECTED TO ROOF JOIST THROUGH ANOTHER UNISTRUT STEEL HANGING ANGLE 1-5/8' 12 GA, UNISTRUT DIA, HEAVY DUTY NUT AND WASHER - ONE ABOVE AND ONE BELOW HANGING ANGLE ROD, NUTS, AND WASHERS TO BE SUPPLIED BY INSTALLING CONTRACTOR UNISTRUT IS PRE -PUNCHED AT FACTORY �a mm i000a 101, wk rr I/ii% �ir1O1 5.00' '5100' 2,00' 1 45.00' 1-x3,00' 7' 6,00'NoM./7' 6.00.0 PLAN VIEW - Hood #1 - 7' 6,00' LONG 6624VHB-PSP-F HANGING ANGLE )F ;HT iPER 23.5% OPEN 'AINLESS STEEL RFORATED PANEL elel:l►1� 1/2' DIA, ALL THREAD ROD CONNECTED TO ROOF JOIST THROUGH ANOTHER HANGING ANGLE ANULL STEEL HANGING ANGLE PLYWOOD ROOF D ',-1/2' DIA. HEAVY DUTY NUT AND WASHER - ONE ABOVE AND ONE BELOW HANGING ANGLE ROD, NUTS, AND WASHERS TO BE SUPPLIED BY INSTALLING CONTRACTOR HANGING ANGLE IS PRE -PUNCHED AT FACTORY 54J HANGING ANGLE 27 Hood #2 12-E4,, 2. o• , U,L. Listed Incondescent Light nx 6' 0,00'Nom./6' 0.00'0 PLAN VIEW - Hood #2 - 6' 0 00' LONG 5424VHB-PSP-F �► / i u�l :: /• i/ 1 �► /I wjmUsi Di omit. ri• iI F �T OPER TYPICAL ROOF MOUNTING DETAIL 23.5% OPEN 'AINLESS STEEL RFORATED PANEL HOOD HANGING DETAIL (SEE PLAN VIEW OF HOOD FOR LOCATION) (TYP. OF 4) 'L' BRACKET OR 1-5/8' 12 GA. UNISTRUT THROUGH BOLTED WOOD J❑IST 1/2' ALL THREAD RODS. HOOD i OUBLE NUT AND WASHER ASSEMBLY O❑D J❑IST MUA DUCT STRAP DETAIL PLYWOOD ROOF DECK #10 WOOD SCREW WOOD JOIST (TYP. OF 2) 11 IWIDE 22 GA. STRAP L - LIGHT GAUGE SHEET METAL SUPPLY DUCT NOTE: MIN, ONE STRAP PER 6' OF DUCT CAPTIVE-AIRE HOODS ARE BUILT IN COMPLIANCE WITH BUILT NSF �� VITDHANCE H NFPA No. 96 4@0 NFPA #96 NSF UL 710 & ULC710 STANDARDS E,T.L, LISTED 3054804-001 STANDARD SERIES DOWN DISCHARGE SUPPLY FANS SUPPLY AIR UNIT DIMENSIONAL DATA BLOWER A I H I CD C E F FILTER QTY. FILTER SIZE WEIGHT 10' 26 1 32 1 28 3.37 21.75 k5A71 2 1 16' X 20' 210 LBS EXTERNAL SERVICE DISCONNECT A B F GALVANIZED SUPPLY FAN C SUPPLY FAN ELECTRICAL DROP H G e `FILTER AIR INTAKE THROUGH FILTER D E CURB WITH 20 GA. CONSTRUCTION 3' CONTINUOUS FLASHING G �-BLOWER OUTLET SIZE �- ROOF OPENING OPTIONS: GREASE BOX HINGED FAN PITCHED CURB INSULATED CURB i r 1 j DUCTWORK BETWEEN EXHAUST RISER ON HOOD AND FAN (BY OTHERS) DUH DIRECT DRIVE CENTRIFUGAL UP -BLAST EXHAUST FANS DIMENSIONAL DATA FAN MODEL HT W B C F R RO WEIGHT LH DU85HFA 30 1/2 31 7/8 2 24 3/4 23 14 7/8 21 1 60 GENERAL NOTES, 1. ELECTRICAL HOOK-UP TO MOTOR CONTROLS (MOTOR STARTERS, FAN SWITCHES, FAN DISCONNECTS, RELAYS, ETC. > BY OTHERS, 2. FIRE CHASE BY OTHERS, IF REQUIRED, 3. ALL PHASES OF INSTALLATION SHALL COMPLY WITH 2004 VERSION OF NEPA 96. 4. WRITTEN MEASUREMENTS HAVE PRECEDENCE OVER SCALE. 5. EXHAUST FAN TO HAVE A MINIMUM OF 10 FT. OF CLEARANCE FROM AIR INTAKES 6. HOOD TO OVERHANG COOKING EQUIPMENT 6' ON ALL OPEN SIDES. 7. BUILDING PRESSURE SHALL NOT EXCEED 0.02' WATER COLUMN AT EXTERIOR DOORS, 8. KITCHEN SHALL BE BALANCED TO BE NEGATIVE WITH RESPECT TO THE DINING ROOM. 9. MUA DUCT SHALL BE 24 GA. GALV, STEEL WITH PITTSBURG SEAM OR 26 GA. SNAPLOCK 10.EXHAUST DUCT SHALL BE 24 GA, GALV. STEEL WITH PITTSBURG SEAM OR 26 GA. SNAPLOCK CURB/ROOFTOP DIMENSIONAL DATA BLOWER G H J K 10' 23 14 11-1/2 13-1/4 PITCHED CURBS ARE AVAILABLE FOR PITCHED ROOFS, 7 SPECIFY PITCHi 30• EXAMPLEt 7/12 PITCH = 301 SLOPE 1 VENTED CURB '0 GAUGE TEEL ;ONSTRUCTION -•,,.GE / RO ROOF OPENING RO �/ DIMENSIONS PITCHED CURBS ARE AVAILABLE 7 FOR PITCHED ROOFS, 30' SPECIFY PITCH, 12 EXAMPLE, 7/12 PITCH = 30' SLOPE CURB DIMENSIONAL DATA FAN MODEL D E DU85HFA 23 '20 BUCHANAN P.E CONSULTING INC. ELECTRICAL " MECHANICAL " PLUMBING .,,0' ENGINEERING 6191 W, ATLANTIC BLVD, SUITE# 11`� MARGATE, FL 33064 Phi 954-590-3300 Faxi 954-590-223 U 4•. - Emalli mepenglneers@aolzom RAJA BUCHANAN FL P.E # 48916 CERTIFICATE OF AUTHORIZATION # 8842 :j 4 �. JOB PIZZA RUSTICA �,t '•.,.-..a'_ �' ♦, _ ��� i� _ _ _, _ LOCATION MIAMI, FL '�,. --:� '� • Y r�r � - _- DWG 1 OF 3 DR.4AN BY rnnrn REV. SCALE NTS O WIND LOAD CALCULATIONS BASED ON 146 MPH Xe6 d' - � _Tf FOR SCREWS HOLDING FAN TO �WRIB EXHAUST FAN DIMENSIONS - 46 DIA. x 36.5" HIGH - 190 LBS A CENTROID OF EXHAUST FAN ABOVE CURB - 21" B AS PER ASCE 7-02 AND FBC 33 LBS./SQ.FT. C AREA OF EXHAUST FAN (ASSUME FLAT SURFACE AS WORST CASE) - 11.66 SQ. FT. D MOMENT ON FAN APPLIED BY WIND A x B x C x 1.5 (SAFETY FACTOR) = 1.5 x 33 x 11.66 x 1.75 = 1010 LB -FT E) SUM MOMENTS TO FIND SHEAR FORCE ON SCREW 1010 = (190 LBS x 1.375') + (SHEAR FORCE x 2.75') SHEAR FORCE = 272.3 LBS, FIVE SCREWS PER SIDE, 54.45 LBS PER SCREW MAXIMUM ALLOWABLE SHEAR STRESS IS APRROXIMATELY 123 LBS BOLTS HOLDING CURB TO ROOF CENTROID OF FAN FROM ROOF - 3.25 FT A E CENTROID OF CURB ABOVE ROOF - 0.833 FT F AREA OF CURB = 4.125 SQ.FT., WEIGHT = 50 LBS G MOMENT ON CURB APPLIED BY WIND E x F X B x 1.5 = 0.833 x 4.125 x 33 x 1.5= 170 LB -FT H) MOMENT ON FAN APPLIED BY WIND A x B x C x 1.5 (SAFETY FACTOR) = 3.25 x 33 x 11.66 x 1.5 = 1876 LB -FT E) SUM MOMENTS TO FIND TENSILE FORCE ON BOLTS 1876 + 170 = (240 LBS x 1.375') + (TENSILE FORCE x 2.75') TENSILE FORCE = 624 LBS, THREE BOLTS PER SIDE, 208 LBS PER BOLT MAXIMUM ALLOWABLE TENSILE STRESS IS APRROXIMATELY 315 LBS BUCHANAN P.E CONSULTING INC. ELECTRICAL " MECHANICAL " PLUMBING .,,0' ENGINEERING 6191 W, ATLANTIC BLVD, SUITE# 11`� MARGATE, FL 33064 Phi 954-590-3300 Faxi 954-590-223 U 4•. - Emalli mepenglneers@aolzom RAJA BUCHANAN FL P.E # 48916 CERTIFICATE OF AUTHORIZATION # 8842 :j 4 �. JOB PIZZA RUSTICA �,t '•.,.-..a'_ �' ♦, _ ��� i� _ _ _, _ LOCATION MIAMI, FL '�,. --:� '� • Y r�r � - _- DWG 1 OF 3 DR.4AN BY rnnrn REV. SCALE NTS