Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
09-97-053
REVISIONS THE GENERAL COMPANIES _ - - - - THE GENERAL C'WPANIES- 01/07/09- LAYOUT b MF.P'S - P8 - I BUILDING WORKS NOTES 1 SZ n 0 0 0 M CL CL 66O CA CD N 4 N 3 v LL E �o M ,1 CD O O i 0 in v REMOTE COMPRESSORS AND CONDENSING UNITS THESE NOTES APPLY TO MULTI -SYSTEM COMPRESSOR RACKS AS WELL AS INDIVIDUAL COMPRESSORS AND CONDENSORS. EXACT LOCATION OF COMPRESSORS ARE TO BE DETERMINED REMOTE COMPRESSOR BY ARCHITECT. FREE do EASY ACCESS INTO AREA FOR COMPRESSORS MUST BE PROVIDED BY OTHERS, TO ALLOW PLACEMENT OF RACK AS WELL AS MAINTAIN MINIMUM CLEARANCE REQUIREMENTS. SUFFICIENT AIR CHANGES MUST BE PROVIDED IN THIS AREA TO ALLOW ADEQUATE AIR CIRCULATION FOR WATER COOLED OR AIR COOLED COMPRESSORS. STRUCTURAL SUPPORT FOR COMPRESSORS, ON ROOF OR INSIDE STRUCTURE, TO BE PROVIDED BY OTHERS. SEE MANUFACTURER'S SHOP DRAWINGS FOR DETAILED REQUIREMENTS FOR CLEARANCE, MECHANICAL, PLUMBING do ELECTRICAL REQUIREMENTS. FOR WATER COOLED UNITS, STRICT ADHERENCE TO MANUFACTURERS REQUIREMENTS FOR MIN./MAX. WATER TEMP AND PRESSURE MUST BE MAINTAINED. ASHRAE CALCULATIONS AND ANY RESULTING REQUIREMENTS FOR COMPRESSOR AREA, PIPING CHASES AND FREON DETECTION SYSTEMS SHALL BE THE RESPONSIBILITY OF OTHERS. ALL REFRIGERANT PIPING CHASES AND BUILDING PENETRATIONS SHALL BE THE RESPONSIBILITY OF THE BUILDING TRADES AND TO COMPLY WITH ALL LOCAL CODES. EXACT UNE RUNS OF REFRIGERATION PIPING SHALL BE DETERMINED IN COORDINATION WITH THE REFRIGERATION INSTALLER. NOTE: A. GENERAL CONTRACTOR TO SLOPE QUARRY TILES AND QUARRY TILE COVED UP SIDES SETTING BED FROM INTERIOR OF WALK-IN BOXES AND SEALED TO INTERIOR AND TOWARD EXTERIOR DOOR 1/8- PER UNEAR FOOT EXTERIOR OF PANELS WITH EPDXY (TYPICAL). SEALANT BY G.C. (TYPICAL) B: UNLESS OTHERWISE NOTED, OVERALL HEIGHT OF WALK-IN SHALL BE 8'-6- ABOVE FINISHED FLOOR. WALK-IN PARTITION PANEL---\ WALK-IN DOOR PANEL ANTI -SWEAT HEATER — SWEEP GASKET EXISTING STRUCTURAL SLAB ruc rLm r u. 1-1 SECTION THRU SECTION THRU DOOR PARTITION WALK-IN FLOOR DETAILS (NO SCALE) 4- WALL PANEL (TYPICAL) 1- AIR SPACE (MINIMUM) /_WALK-IN EXTERIOR WALL PANEL WALL UNE I ` WATER PROOF Imo* MEMBRANE BY G.C. SECTION THRU EXTERIOR WALL ------------------------------------ I I I I I ROOFTOP EXHAUST FANS & MAKE—UP AIR FANS NOTES: 1. THESE ITEMS ARE TO BE LOCATED Of THE ARCHITECT & IN CONJUNCTION WITH THE EXHAUST HOOD MANUFACTURER'S SHOP DRAWING. REFER TO ARCHITECTURAL DRAWINGS FOR DIACT LOCATION. 2 ALL PENETRATIONS THRU ROOF OR BUILDING STRUCTURE, INCLUDING JOISTS OR OTHER STRUCTURAL MEMBERS, IS TO BE BY OTHERS. E�T SUPPLY FAN n SOLEA LINES (BY PURVEYOR) TO EXTEND IN WALLS do OVER CEILING TO BEVERAGE COUNTER (VERIFY W/PURNEYOR) --� i I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I LI /I � I i I � I I � I � I �I \I 11 I I I I i I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I ------------------------- 1. THIS DRAWING SHALL BE USED AS AN INSTRUMENT OF REFERENCE BY ALL OTHER TRADES AND CONTRACTORS. ALL TRADES SHALL VERIFY THE INFORMATION AS SHOWN ON THESE PLANS. FOR SPECIFIC CONNECTION INFORMATION, REFER TO THE ARCHITECT AND/OR CONTRACTOR'S DRAWINGS 2. DIMENSIONS AND REQUIREMENTS FOR ALL EXISTING EQUIPMENT PROVIDED BY OTHERS MUST BE VERIFIED. 3. ALL NATKNNAI., STATE AND LOCAL CODES SHALL APPLY. 4. ARCHITECT TO LOCATE, GENERAL. CONTRACTOR TO PROVIDE ALL OPENINGS IN WALLS, FLOORS, CEILINGS, AND ROOFS FOR THE EXTENSION OF REFRIGERATION LINES, BEVERAGE LINES, ELECTRICAL. LINES, PLUMBING LINES, EXHAUST AND SUPPLY VENTILATION DUCTS. CURBS, PITCH POCKETS OR SPECIAL FINISHING FOR THESE OPENINGS SWILL BE SUPPLIED BY OTHERS. 5. SUPPLY FANS TO BE LOCATED A MINIMUM OF 10'-T FROM ANY AIR INLET OR OUTLET ON THE ROOF SUCH AS EXHAUST FANS, VENT STACKS, AIR CONDITIONERS, REFRIGERATION COMPRESSORS, ETC. 6. ALL INFORMATION FRONDED FOR HOOD SYSTEMS PERTAINING TO QUANTITY, SRE AND LOCATION OF EXHAUST AND SUPPLY DUCT COLLARS, CFM RATINGS AND STATIC PRESSURE MUST BE CONFIRMED WITH THE MANUFACTURER'S APPROVED SHOP DRAWINGS. 7. GENERAL. CONTRACTOR TO PROVIDE 3/4' PLYWOOD WAIL BACKING ON ALL WAILS FROM 24' A.F.F. TO 86' A.F.F. FOR ALL WALL MOUNTED EQUIPMENT. LOCATION TO BE COORDINATED MANUFACTURER'S SHOP DRAWINGS AND SPECIFICATION SHEETS. 8. PROVIDE COVED BASES AT ALL VERTICAL INTERSECTIONS OF FLOORS IN KITCHEN AND STORAGE AREAS. 9. PROVIDE THE GENERAL COMPANIES WITH ALL FOUR-WAY REGISTER LOCATIONS IN THE mm AREA FOR COORDINATION WITH THE EXHAUST HOOD. FOUR-WAY REGISTER LOCATIONS MAY AFFECT HOOD PERFORMANCE HVAC REGISTERS MAY AFFECT THE PERFORMANCE OF 0mhUST HOODS, HEAT LAMPS AND OTHER EQUIPMENT. LOCATIONS OF THESE REGISTERS SHOULD BE COORDINATED WITH THE MANUFACTURER. 10. BOTTOM OF HOODS ARE TO MOUNTED AT 6'-6' ABOVE FINISHED FLOOR, UNLESS OTHERWISE SPECIFIED BY LOCAL. CODES. 11. RECOMMENDED CEILING HEIGHTS ARE LISTED BELOW. CONTACT GENERAL COMPANIES IMMEDIATELY IF MINIMUM HEIGHTS ARE LESS THAN THOSE INDICATED: a. KITCHEN AREAS WITH EXHAUST HOODS: 8'6' b. KITCHEN AREAS WITH WALK-IN COOLER/FREEIEtS: 9'-6' c. KITCHEN AREAS WITH ICE MACHINES d%r COMPRESSORS: 9'-T d. GENERAL. KTTCHL4 AREAS: 8'-T 12. ALL CONDENSING UNITS & COMPRESSOR UNITS ARE TO BE LOCATED OUTSIDE WHERE POSSIBLE. FOR INSIDE LOCATIONS, VERIFY PROVISION OF SUFFICIENT VENTILATION WITH MANUFACTURER ARCHITECT TO LOCATE ALL REMOTE COMPRESSORS AND CONDENSERS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. BUILDING CONDITIONS & VENTILATION LEGEND ® SLAB RECESS BEVERAGE UNE STUB IN WALL BACKING ® ON - WALL MATERIAL MUBUSTIBLL BEER/WINE UNE CON SODA UNE CONDUIT EXHAUST DUCT COLLAR LOCATION DUCT LmSUPPLY COLLAR LOCATION i BUILDING WORKS PLAN THIS DRAWING IS AN INSTRUMENT OF SERVICE FOR OTHER CONTRACTORS ALL DIMENSIONS TO BE VERIFIED ON THE JOB SITE, AND COMPACTORS SHOULD CHECK WITH EQUIPMENT SUPPLIER REGARDING ROUGHING IN WORK ALL DIMENSIONS ARE FROM FINISHED FLOORS AND WALLS. ALL STUBBING TO BE 3' ABOVE FINISHED FLOORS UNLESS OTHERWISE SPECIFIED ACTUAL LOCATIONS OF FLOOR DRAINS, SIZES AND LOCATION OF VENTILATING EQUIPMENT AND GREASE TRAPS TO BE DETERMINED BY ARCHITECT OR ENGINEER. THIS DRAWING AND SPECIFICATIONS ARE THE PROPERTY OF GENERAL HOTEL AND RESTAURANT SUPPLY CORP., AND ARE NOT TO BE USED ON ANY WORK IN WHOLE OR IN PART EXCEPT BY WRITTEN AGREEMENT WITH GENERAL HOTEL AND RESTAURANT SUPPLY CORP. PLUMBING AND ELECTRICAL LOCATIONS AS SHOWN ON PIAN ARE OF OUTLETS AS THEY EXIST ON FIXTURES MECHANICAL TRADES WILL MAKE ALLOWANCE FOR VARIOUS FITTINGS TO TARE CARE OF CONNECTING UP TO FUTURE. ©COPYRIGHT 2008 ALL RIGHTS RESERVED 01 /12/09 LAYOUT & M.E.P'S-JAP mj 0. O10 N 0 ciE -) Do o aJQNE 0� O IL � U � 0 LL- o 0 � L N Q x c: zL`v WLLIrn (D ("D Q LZ 00 U ZQ Ln 'o+ W �� N — OpLf ) W o A o ai w W o 0 0 �2 Ti W 8 z 0 i W� :D< r Z M U w c'' u 0 Lo J 3: LL Q CJS N o� N oQ � co � C0 DRAWN BY JTG CHECKED ENGINEERING DATE 12/21/08 SCALE 1/4"=11-011 JOB NO. 2008131 SHEET FS -4 OF c