09-97-052
I a M 00 0 0 N c al E CL Ln c N •C Ln l71 � X m d- Ln cu kQ a; ►h w CL 00 0 OCD O M i � N Y THE GENERAL COMPANIES ' - - THE r•ENERAI COMPANIES REMOTE COMPRESSORS AND CONDENSING UNITS THESE NOTES APPLY TO MULTI -SYSTEM COMPRESSOR RACKS AS WELL AS INDIVIDUAL COMPRESSORS AND CONDENSORS. EXACT LOCATION OF COMPRESSORS ARE TO BE DETERMINED BY ARCHITECT. FREE & EASY ACCESS INTO AREA FOR COMPRESSORS MUST BE PROVIDED BY OTHERS, TO ALLOW PLACEMENT OF RACK AS WELL AS MAINTAIN MINIMUM CLEARANCE REQUIREMENTS. REMOTE COMPRESSOR SUFFICIENT AIR CHANGES MUST BE PROVIDED IN THIS AREA TO ALLOW ADEQUATE AIR CIRCULATION FOR WATER COOLED OR AIR COOLED COMPRESSORS. STRUCTURAL SUPPORT FOR COMPRESSORS, ON ROOF OR INSIDE STRUCTURE, TO BE PROVIDED BY OTHERS. SEE MANUFACTURER'S SHOP DRAWINGS FOR DETAILED REQUIREMENTS FOR CLEARANCE, MECHANICAL, PLUMBING & ELECTRICAL REQUIREMENTS. FOR WATER COOLED UNITS, STRICT ADHERENCE TO MANUFACTURERS REQUIREMENTS FOR MIN. MAX. WATER P AN MIN./ M. D PRESSURE MUST BE MAINTAINED. ASHRAE CALCULATIONS AND ANY RESULTING REQUIREMENTS FOR COMPRESSOR AREA, PIPING CHASES AND FREON DETECTION SYSTEMS SHALL BE THE RESPONSIBILITY OF OTHERS. ALL REFRIGERANT PIPING CHASES AND BUILDING PENETRATIONS SHALL BE THE RESPONSIBILITY OF THE BUILDING TRADES AND TO COMPLY WITH ALL LOCAL CODES. EXACT LINE RUNS OF REFRIGERATION PIPING SHALL BE DETERMINED IN COORDINATION WITH THE REFRIGERATION INSTALLER. NOTE: A: GENERAL CONTRACTOR TO SLOPE QUARRY TILES AND QUARRY TILE COVED UP SIDES SETTING BED FROM INTERIOR OF WALK-IN BOXES AND SEALED TO INTERIOR AND TOWARD EXTERIOR DOOR 1/8" PER LINEAR FOOT EXTERIOR OF PANELS WITH EPDXY (TYPICAL). SEALANT BY G.C. (TYPICAL) B: UNLESS OTHERWISE NOTED, OVERALL HEIGHT OF WALK-IN SHALL BE 8'-6" ABOVE FINISHED FLOOR. WALK-IN PARTITION PANEL—\ 1/2" WALK-IN DOOR PANEL -----,,,,,,QUARRY TILE AND SETTING ANTI -SWEAT w BED BY G.C.— HEATER ADJUSTABLE -'- SWEEP GASKET A. EXISTING STRUCTURAL CENTERLINE DIMENSIONS CENTERUI SLAB PER PLAN PE SECTION THRU SECTION THRU DOOR PARTITION WALK-IN FLOOR DETAILS (NO SCALE) 4" WALL PANEL (TYPICAL) 1" AIR SPACE (MINIMUM) /_WALK-IN EXTERIOR WALL PANEL WALL LINE WATER PROOF JS MEMBRANE BY G.C. SECTION THRU EXTERIOR WALL ROOFTOP EXHAUST FANS & MAKE-UP AIR FANS NOTES: 1. THESE ITEMS ARE TO BE LOCATED BY THE ARCHITECT & IN CONJUNCTION WITH THE EXHAUST HOOD MANUFACTURER'S SHOP DRAWING. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATION. 2. ALL PENETRATIONS THRU ROOF OR BUILDING STRUCTURE, INCLUDING JOISTS OR OTHER STRUCTURAL. MEMBERS, IS TO BE BY OTHERS. E1 T 1`Jka�/ SUPPLY FAN I L ------ F L OR/ ikAhips'• , c� . 7 � BUILDING WORKS NOTES - -=--- - ---- 1. THIS DRAWING SHALL BE USED AS AN INSTRUMENT OF REFERENCE BY ALL OTHER TRADES AND CONTRACTORS. ALL TRADES SHAM. VERIFY THE INFORMATION AS SHOWN ON THESE PLANS. FOR SPECIFIC CONNECTION INFORMATION, REFER TO THE ARCHITECT AND/OR CONTRACTOR'S DRAWINGS. 2. DIMENSIONS AND REQUIREMENTS FOR ALL EXISTING EQUIPMENT PROVIDED BY OTHERS MUST BE VERIFIED. 3. ALL NATIONAL, STATE AND LOCAL CODES SHALL APPLY. 4. ARCHITECT TO LOCATE, GENERAL CONTRACTOR TO PROVIDE ALL OPENINGS IN WALLS, FLOORS, CEILINGS, AND ROOFS FOR THE EXTENSION OF REFRIGERATION LINES, BEVERAGE LINES, ELECTRICAL LINES, PLUMBING LINES, EXHAUST AND SUPPLY VENTILATION DUCTS. CURBS, PITCH POCKETS OR SPECIAL FINISHING FOR THESE OPENINGS SHALL BE SUPPLIED BY OTHERS. 5. SUPPLY FANS TO BE LOCATED A MINIMUM OF 10'-0' FROM ANY AIR INLET OR OUTLET ON THE ROOF SUCH AS EXHAUST FANS, VENT STACKS, AIR CONDITIONERS, REFRIGERATION COMPRESSORS, ETC. 6. ALL INFORMATION PROVIDED FOR HOOD SYSTEMS PERTAINING TO QUANTITY, SIZE AND LOCATION OF EXHAUST AND SUPPLY DUCT COLLARS, CFM RATINGS AND STATIC PRESSURE MUST BE CONFIRMED WITH THE MANUFACTURER'S APPROVED SHOP DRAWINGS. 7. GENERAL CONTRACTOR TO PROVIDE 3/4' PLYWOOD WALL BACKING ON ALL WALLS FROM 24' A.F.F. TO 86' A.F.F. FOR ALL WALL MOUNTED EQUIPMENT. LOCATION TO BE COORDINATED MANUFACTURER'S SHOP DRAWINGS AND SPECIFICATION SHEETS. 8. PROVIDE COVED BASES AT ALL VERTICAL INTERSECTIONS OF FLOORS IN KITCHEN AND STORAGE AREAS. 9. PROVIDE THE GENERAL COMPANIES WITH ALL FOUR-WAY REGISTER LOCATIONS IN THE KITCHEN AREA FOR COORDINATION WITH THE EXHAUST HOOD. FOUR-WAY REGISTER LOCATIONS MAY AFFECT HOOD PERFORMANCE. HVAC REGISTERS MAY AFFECT THE PERFORMANCE OF EXHAUST HOODS HEAT LAMPS AND OTHER EQUIPMENT. Q LOCATIONS OF THESEREGISTERS EG STERS SHOULD BE COORDINATED WITH THE MANUFACTURER. 10. BOTTOM OF HOODS ARE TO MOUNTED AT 6'-6' ABOVE FINISHED FLOOR, UNLESS OTHERWISE SPECIFIED BY LOCAL CODES. 11. RECOMMENDED CEILING HEIGHTS ARE LISTED BELOW. CONTACT GENERAL COMPANIES IMMEDIATELY IF MINIMUM HEIGHTS ARE LESS THAN THOSE INDICATED: o. KITCHEN AREAS WITH EXHAUST HOODS: 8'6' b. KITCHEN AREAS WITH WALK-IN COOLER/FREEZERS: 9'-6' c. KITCHEN AREAS WITH ICE MACHINES &/or COMPRESSORS: 9'-0' d. GENERAL KITCHEN AREAS: 8'-0' 12. ALL CONDENSING UNITS & COMPRESSOR UNITS ARE TO BE LOCATED OUTSIDE WHERE POSSIBLE. FOR INSIDE LOCATIONS, VERIFY PROVISION OF SUFFICIENT VENTILATION WITH MANUFACTURER. ARCHITECT TO LOCATE ALL REMOTE COMPRESSORS AND CONDENSERS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. BUILDING CONDITIONS & VENTILATION LEGEND BEVERAGE LINE STUB i IN WALL BACKING BEER/WINE LINE COND SODA LINE CONDUIT i' y I t BUILDING WORKS PLAN THS DRAWING 6 AN INSTRUMENT OF SERVICE FOR OTHER CONTRACTORS. ALL DILENSDFS M BE VERFFD ON THE JOB SITE AND CONTRACTORS SHOULD CHECK WITH EQUIPMENT SUPPLIER REGARDING ROUGHING N WORK ALL DME NSIOFS ARE FROM DAM FLOORS AND WAILS. All. STUBBING TO BE Y ABOVE FIW40 RM UNLESS OUERWISE SPECFIED. ACIUAL LOCATKMIS OF FLOOR DRAINS, SIZES AND LOCATION OF MTLATNG EQUIPMENT AND GREASE TRAPS M BE MIFRMNED BY ARCHITECT OR DOAUL THIS DRAWING AND TMFICATIONS ARE THE PROPERTY OF GENERAL HOTEL AND RESTAURANT SUPPLY ODRP., AND ARE NOT M BE USED ON ANY WORK IN WHOLE OR IN PART EXCEPT BY WRITTEN AGREEMENT WTiH GENERAL HOTEL AFD RESTAURANT SUPPLY CORP. PLULBNG AND ELECTRIC& LOCATIONS AS %IONTN ON PLAN ARE OF DAM AS M DW ON FIXTURES. MECHANICAL TRADES WILL MAKE ALLOWANCE FOR VARDUS FTRNGS M TAKE CARE OF CONNECTNG UP M FWURE. ©COPYRIGHT 2008 ALL RIGHTS RESERVED REVISIONS 01/07/09 0 LAYOUT& MEPS-PB 03/23/09FIRE 0 m ON au o a `_I /- N d. Of of L'" p O � s N v Qx u`> z m LL N W f.ol \® rn zZo Q) a w Ib °' ZQ Ln 'm W -0 1100 o c (V . 00L- WZ v LE A o 0 W o 0 0 M2 w 8 z w U X W M d' Q :D T— Z cy) V WM f-= > Q U) Qo �o J LL Q � N -' NO c:) 00 - cot DRAWN BY JTG CHECKED ENGINEERING DATE 12/21/08 SCALE 1/4"= 1 1-011 JOB NO. 2008131 SHEET FS -4 - OF NON USTIBLE ® MATERIAL WALL MATERIAL EXHAUST DUCT COLLAR LOCATION SUPPLY DUCT COLLAR LOCATION BEVERAGE LINE STUB i IN WALL BACKING BEER/WINE LINE COND SODA LINE CONDUIT i' y I t BUILDING WORKS PLAN THS DRAWING 6 AN INSTRUMENT OF SERVICE FOR OTHER CONTRACTORS. ALL DILENSDFS M BE VERFFD ON THE JOB SITE AND CONTRACTORS SHOULD CHECK WITH EQUIPMENT SUPPLIER REGARDING ROUGHING N WORK ALL DME NSIOFS ARE FROM DAM FLOORS AND WAILS. All. STUBBING TO BE Y ABOVE FIW40 RM UNLESS OUERWISE SPECFIED. ACIUAL LOCATKMIS OF FLOOR DRAINS, SIZES AND LOCATION OF MTLATNG EQUIPMENT AND GREASE TRAPS M BE MIFRMNED BY ARCHITECT OR DOAUL THIS DRAWING AND TMFICATIONS ARE THE PROPERTY OF GENERAL HOTEL AND RESTAURANT SUPPLY ODRP., AND ARE NOT M BE USED ON ANY WORK IN WHOLE OR IN PART EXCEPT BY WRITTEN AGREEMENT WTiH GENERAL HOTEL AFD RESTAURANT SUPPLY CORP. PLULBNG AND ELECTRIC& LOCATIONS AS %IONTN ON PLAN ARE OF DAM AS M DW ON FIXTURES. MECHANICAL TRADES WILL MAKE ALLOWANCE FOR VARDUS FTRNGS M TAKE CARE OF CONNECTNG UP M FWURE. ©COPYRIGHT 2008 ALL RIGHTS RESERVED REVISIONS 01/07/09 0 LAYOUT& MEPS-PB 03/23/09FIRE 0 m ON au o a `_I /- N d. Of of L'" p O � s N v Qx u`> z m LL N W f.ol \® rn zZo Q) a w Ib °' ZQ Ln 'm W -0 1100 o c (V . 00L- WZ v LE A o 0 W o 0 0 M2 w 8 z w U X W M d' Q :D T— Z cy) V WM f-= > Q U) Qo �o J LL Q � N -' NO c:) 00 - cot DRAWN BY JTG CHECKED ENGINEERING DATE 12/21/08 SCALE 1/4"= 1 1-011 JOB NO. 2008131 SHEET FS -4 - OF