09-97-051THE GENERAL COMPANIES IN Q 1. N ri 0 rn 0 CD N w r -i 3 N J E 9- 4 M .-a 00 O CD .-H Y 0 E v C v c 0 CL E cu,F— Ln v O �u � c M U1 x C N ink -0 •c i Q •� rh v n. Eo � � 0 0 0 M / a U Y REMOTE COMPRESSORS AND CONDENSING UNITS THESE NOTES APPLY TO MULTI -SYSTEM COMPRESSOR RACKS AS WELL AS INDIVIDUAL COMPRESSORS AND CONDENSORS. EXACT LOCATION OF COMPRESSORS ARE TO BE DETERMINED BY ARCHITECT. FREE & EASY ACCESS INTO AREA FOR COMPRESSORS MUST BE PROVIDED BY OTHERS, TO ALLOW PLACEMENT OF RACK AS WELL AS MAINTAIN MINIMUM CLEARANCE REQUIREMENTS. SUFFICIENT AIR CHANGES MUST BE PROVIDED IN THIS AREA TO ALLOW ADEQUATE AIR CIRCULATION FOR WATER COOLED OR AIR COOLED COMPRESSORS. STRUCTURAL SUPPORT FOR COMPRESSORS, ON ROOF OR RnAo7E INSIDE STRUCTURE, TO BE PROVIDED BY OTHERS. COMPRESSOR SEE MANUFACTURER'S SHOP DRAWINGS FOR DETAILED REQUIREMENTS FOR CLEARANCE:, MECHANICAL, PLUMBING & ELECTRICAL REQUIREMENTS. FOR WATER COOLED UNITS, STRICT ADHERENCE TO MANUFACTURERS REQUIREMENTS FOR R M MIN./MAX. WATER TEMP AND PRESSURE UST BE MAINTAINED. ASHRAE CALCULATIONS AND ANY RESULTING REQUIREMENTS FOR COMPRESSOR AREA, PIPING CHASES AND FREON DETECTION SYSTEMS SHALL BE THE RESPONSIBILITY OF OTHERS. ALL REFRIGERANT PIPING CHASES AND BUILDING PENETRATIONS SHALL BE THE RESPONSIBILITY OF THE BUILDING TRADES AND TO COMPLY WITH ALL LOCAL CODES. EXACT LINE RUNS OF REFRIGERATION PIPING SHALL BE DETERMINED IN COORDINATION WITH THE REFRIGERATION INSTALLER. 0 WALL lI BACKING SEE NOTE i oil WALL BACKING I.LjI SEE NOTE 7 z N I co 11, WALL BACKING SEE NOTE 7 WALL BACKING SEE NOTE 7 ee 0 NOTE: SLAB RECESS A: GENERAL CONTRACTOR TO SLOPE QUARRY TILES AND QUARRY TILE COVED UP SIDES SETTING BED FROM INTERIOR OF WALK-IN BOXES AND SEALED TO INTERIOR AND 4- WALL PANEL (TYPICAL) TOWARD EXTERIOR DOOR 1/8- PER LINEAR FOOT EXTERIOR OF PANELS WITH EPDXY 1- AIR SPACE (MINIMUM) (TYPICAL). SEALANT BY G.C. (TYPICAL) B: UNLESS OTHERWISE NOTED, OVERALL HEIGHT OF WALK-IN EXTERIOR WALK-IN SHALL BE 8'-6- ABOVE FINISHED FLOOR. WALK-IN WALL PANEL PARTITION PANEL WALK-IN ®EXHAUST WALL LINE DOOR PANEL QUARRY TILE SUPPLY DUCT AND SETTING COLLAR LOCATION ANTI -SWEAT BED BY G.C. HEATER DJUSTABLE SWEEP GASKET 1/2- 777 EXISTING WATER PROOF STRUCTURALCENTERUNE DIMENSIONSN IM I N MEMBRANE SLAB PER PURI PER PLAN BY G.C. SECTION THRU SECTION THRU SECTION THRU DOOR PARTITION EXTERIOR WALL WALK-IN FLOOR DETAILS (NO SCALE) (I SEE NOTE 7 4'-10' EXHAUST HOOD SEE MANUFACTURER SHOP D INGS FOR HOOD REQUIREM WALL BACKIN( Fmc SEE NOTE 7 C3, I I - I I •I I I / ROOFTOP EXHAUST FANS & MAKE-UP AIR FANS NOTES: 1. THESE ITEMS ARE TO BE LOCATED BY THE ARCHITECT & IN CONJUNCTION WITH THE EXHAUST HOOD MANUFACTURER'S SHOP DRAWING. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATION. 2. ALL PENEMATKNIS THRU ROOF OR BUILDING STRUCTURE, INCLUDING JOISTS OR OTHER STRUCTURAL MEMBERS, IS TO BE BY OTHERS. �T SUPPLY r ------�r---------- r� II I I I TILL I I I I�--�I / \ i� �� / \ i 3ru" v v v SODA LINES (BY PURVEYOR) TO EXTEND IN WALLS & OVER CEILING TO BEVERAGE COUNTER (VERIFY W/PURVEYOR) I I I I I I I WALZ/ CKIN 7'-8' EXHAUST HOOD SEE N SEE MANUFACTURER SHOP DRAWINGS FOR HOOD REQUIREIAE I I n 11! / �/ V I ALL BACKIN SEE NOTEAl it/I I O r ---------------- I I I FAA SODA LINES URVEYOR) TO EXTEN IN WALLS R CEILING TO BEVERAGE CO (VERIFY W/PURVEYOR) I I FAN I' --------------------------I NOR I L ---------------------------- BUILDING WORKS NOTES ^ 1 1. THIS DRAWING SHALL BE USED AS AN INSTRUMENT OF REFERENCE BY ALL OTHER TRADES AND CONTRACTORS. ALL TRADES SHALL VERIFY THE INFORMATION AS SHOWN ON THESE PLANS. FOR SPECIFIC CONNECTION INFORMATION, REFER TO THE ARCHITECT AND/OR CONTRACTOR'S DRAWINGS. 2. DIMENSIONS AND REQUIREMENTS FOR ALL EXISTING EQUIPMENT PROVIDED BY OTHERS MUST BE VERIFIED. 3. ALL NATIONAL, STATE AND LOCAL CODES SHAH APPLY. 4. ARCHITECT TO LOCATE, GENERAL CONTRACTOR TO PROVIDE ALL OPENINGS IN WALLS, FLOORS, CEILINGS, AND ROOFS FOR THE EXTENSION OF REFRIGERATION LINES, BEVERAGE LINES, ELECTRICAL LINES, PLUMBING LINES, EXHAUST AND SUPPLY VENTILATION DUCTS. CURBS, PITCH POCKETS OR SPECIAL FINISHING FOR THESE OPENINGS SHALL BE SUPPLIED BY OTHERS. 5. SUPPLY FANS TO BE LOCATED A MINIMUM OF 10'-0' FROM ANY AIR INLET OR OUTLET ON THE ROOF SUCH AS EXHAUST FANS, VENT STACKS, AIR CONDITIONERS, REFRIGERATION COMPRESSORS, ETC. 6• ALL INFORMATION PROVIDED FOR HOOD SYSTEMS PERTAINING TO QUANTITY, SIZE AND LOCATION OF EXHAUST AND SUPPLY DUCT COLLARS, CFM RATINGS AND STATIC PRESSURE MUST BE CONFIRMED WITH THE MANUFACTURER'S APPROVED SHOP DRAWINGS. 7. GENERAL CONTRACTOR TO PROVIDE 3/4' PLYWOOD WALL BACKING ON ALL WALLS FROM 24' A.F.F. TO 86' A.F.F. FOR ALL WALL MOUNTED EQUIPMENT. LOCATION TO BE COORDINATED MANUFACTURER'S SHOP DRAWINGS AND SPECIFICATION SHEETS. 8. PROVIDE COVED BASES AT ALL VERTICAL INTERSECTIONS OF FLOORS IN KITCHEN AND STORAGE AREAS. 9. PROVIDE THE GENERAL COMPANIES WITH ALL FOUR-WAY REGISTER LOCATIONS IN THE KITCHEN AREA FOR COORDINATION WITH THE EXHAUST HOOD. FOUR-WAY REGISTER LOCATIONS MAY AFFECT HOOD PERFORMANCE HVAC REGISTERS MAY AFFECT THE PERFORMANCE OF EXHAUST HOODS, HEAT LAMPS AND OTHER EQUIPMENT. LOCATIONS OF THESE REGISTERS SHOULD BE COORDINATED WITH THE MANUFACTURER. 10. BOTTOM OF HOODS ARE TO MOUNTED AT 6'-6' ABOVE FINISHED FLOOR, UNLESS OTHERWISE SPECIFIED BY LOCAL CODES. 11. RECOMMENDED CEILING HEIGHTS ARE LISTED BELOW. CONTACT GENERAL COMPANIES IMMEDIATELY IF MINIMUM HEIGHTS ARE LESS THAN THOSE INDICATED: a. KITCHEN AREAS WITH EXHAUST HOODS: 8'6' b. KITCHEN AREAS WITH WALK-IN COOLER/FREEZERS: 9'-6' c. KITCHEN AREAS WITH ICE MACHINES &/or COMPRESSORS: 9'-0' d. GENERAL KITCHEN AREAS: 8'-0' 12. ALL CONDENSING UNITS & COMPRESSOR UNITS ARE TO BE LOCATED OUTSIDE WHERE POSSIBLE. FOR INSIDE LOCATIONS, VERIFY PROVISION OF SUFFICIENT VENTILATION WITH MANUFACTURER. ARCHITECT TO LOCATE ALL REMOTE COMPRESSORS AND CONDENSERS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. BUILDING CONDITIONS & VENTILATION LEGEND ® SLAB RECESS BEVERAGE LINE STUB UP IN WALL BACKING A NON MATERIAL WALL MATERI �� BEER WINE UNE CONDUI BEER/WINE SODA LINE CONDUIT DUCT ®EXHAUST COLLAR LOCATION SUPPLY DUCT COLLAR LOCATION BUILDING WORKS PLAN THS DRAWING S AN INSTRUMENT OF SERVICE FDR OTHER CONTRACTORS. ALL DIMEHSCINS TO BE VERM ON THE JOB SITE, AND CONTRACTORS SHOIM CHECK WITH EQUIPMENT SUPPLER REGARDING ROUGHING N WORK ALL DIIE BIONS ARE FROM FWG FLOORS AND WALLS. ALL STUBBING TO BE 3' ABOVE RNSHIII FLOORS UNLESS OTHERWISE SPECFG. ACTUAL LOCKMNS OF FLOOR DRARS. SSS AND LOCATION OF VENTILATING EQUIPMENT AND GREASE TRAPS TO BE DETERIfta BY ARCHITECT OR ENGPfFR THIS DRAWING AND SPECIFICATIONS ARE THE PROPERTY OF GENERAL H01M AND RESTAURANT SUPPLY CORP. AHL) ARE NOT TO BE USED ON ANY WORK IN WHOLE OR IN PART EXCEPT BY WRITTEN AGRET]NENT WITH GE EIK HOTEL AND RESTAURANT SUPPLY CORP. PUABNG AND ELECTRICAL LOCATIONS AS SHOWN ON PLAN ARE OF OUTLETS AS THEY EXIST ON FIXTURES MECHANICAL TRADES WILL MIO: ALLOK*a FOR VARIOUS FlflNGS TO TAKE CURE OF CONNECTING UP TO FIXTURE. ©COPYRIGHT 2008 ALL RIGHTS RESERVED REVISIONS THE GENERAL CO•APANIES - - Ja: 1% '0 0 000 V o N0 J o� � ld. � IL M 0 � •v o x `Q) Z:2LL_ °' Lurn w Ln Q w 00 a) Z�•. c � 'rn WTO � � c IOC 0 i Lu o 0 A C) uiw W o 0 0 M EL- W i O U z 0 s W M d' Dr Z M V W cM Q U) _c —N 4-a1. K r-4%.0 LO I Q3: u— ' ) N �J J — O N oQ DRAWN BY JTG CHECKED ENGINEERING DATE 12/21/08 SCALE 1/411=11-011 JOB NO. 2008131 SHEET FS -4 OF