09-97-049THE GENERAL COMPANIES THS GENEPOL COM^ANTES _ ■ REMOTE COMPRESSORS AND CONDENSING UNITS THESE NOTES APPLY TO MULTI -SYSTEM COMPRESSOR RACKS AS WELL AS INDIVIDUAL I I I COMPRESSORS AND CONDENSORS. EXACT LOCATION OF COMPRESSORS ARE TO BE DETERMINED ABOVE FINISHED FLOOR BY ARCHITECT. FREE & EASY ACCESS INTO AREA FOR COLD WATER SUPPLY COMPRESSORS MUST BE PROVIDED BY OTHERS, TO ALLOW BELOW FINISHED FLOOR PLACEMENT OF RACK AS WELL AS MAINTAIN MINIMUM DIRECT WASTE CLEARANCE REQUIREMENTS. COLD WATER SUFFICIENT AIR CHANGES MUST BE PROVIDED IN THIS AREA INDIRECT WASTE TO ALLOW ADEQUATE AIR CIRCULATION FOR WATER COOLED FLOOR DRAIN OR AIR COOLED COMPRESSORS. GAS SUPPLY STRUCTURAL SUPPORT FOR COMPRESSORS, ON ROOF OR REMDrE INSIDE STRUCTURE, TO BE PROVIDED BY OTHERS. COMPRESSOR SEE MANUFACTURER'S SHOP DRAWINGS FOR DETAILED STUB OUT REQUIREMENTS FOR CLEARANCE, MECHANICAL, PLUMBING & FLOOR SINK ELECTRICAL REQUIREMENTS. FOR WATER COOLED UNITS, STRICT ADHERENCE TO MANUFACTURERS REQUIREMENTS FOR MIN./MAX. WATER TEMP AND PRESSURE MUST BE MAINTAINED. STUB UP ASHRAE CALCULATIONS AND ANY RESULTING REQUIREMENTS FLOOR DRAIN FOR COMPRESSOR AREA, PIPING CHASES AND FREON STUB DOWN DETECTION SYSTEMS SHALL BE THE RESPONSIBILITY OF OTHERS. ALL REFRIGERANT PIPING CHASES AND BUILDING PENETRATIONS SHALL BE THE RESPONSIBILTIY OF THE BUILDING TRADES AND TO COMPLY WITH ALL LOCAL CODES. EXACT LINE RUNS OF REFRIGERATION PIPING SHALL BE PLUMBING NOTE: DETERMINED IN COORDINATION WITH THE REFRIGERATION VERIFY ALL DETAILS ATH MANUFACTURERS LATEST SHOP D INGS. INSTALLER. 1/2' CW & HW, 24' AFF, (JANITOR FAU( 3' WASTE. STUB UP TO (JANITOR SINK) 0 FLOOR SINK, EXTM__1J 7T-1 DRAIN FROM THREE COMPARTMENT SINK & ICE 4/2' CW, 72' AFF,(WATER FILTER) INTERCONNECT FILTERS TO (ICE MACHINES& SODA SYSTEM) 3/4' CW & HW, 24- AFF, (FAUCETS) 1-1/2' DIRECT WASTE `- T__ - - 18- AFF, (HAND SINK) 1/2' CW & HW, 24- AFF, (FAUCET) 1/2' CW & HW, 24' AFF, (FAUCET)— FLOOR SINK, EXTEND DRAIN FROM COIL & SINK — 3/4- GAS (45,000 BTU 24' AFF(PIZZA OVEN) - ml ------ = ROOFTOP EXHAUST FANS & MAKE-UP AIR FANS NOTES: 1. THESE ITEMS ARE TO BE LOCATED BY THE ARCHITECT & IN CONJUNCTION WITH THE EXHAUST HOOD MANUFACTURER'S SHOP DRAWING. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATION. 2. ALL PENETRATIONS THRU ROOF OR BUILDING STRUCTURE, INCLUDING JOISTS OR OTHER STRUCTURAL MEMBERS, IS TO BE BY OTHERS. E�T SUPPLY FAN FD FD —e12 -C' AFF,(WATERCONNECT CHINE & SE' \THRU WALLS \. \\ 1,L/�L'' DIRECT WASTE 18' AFF, (HAND SINK 1/2- CW & HW. 18' AFF, (FAUCET) I r� I I I I I I PLUMBING LEGEND I I I iC-- A v _ __3/4' GAS_(t35,000 BTU _ '44 AprpTZZA-b� I ❑� 1 /I 1/2' CW, 18" AFF, v I (SODA DISPENSER) Al k1l, FLOOR SINK, EXTEND DRAIN FROM Iftll II I\ (SODA DISPENSER & ICE BIN) r ------------------------------- I I I I I III I I I 1 I I II 111 I I 1 FLOOR SINK, EXTEND DRAIN FROM I (SODA DISPENSER & ICE MACHINE) I L ------------------------------ I % I I \\ I 1 11 11 I I I I I I I I �I /I I I I I I I —J L 0 PLUMBING NOTES =-- —� i 1. THIS DRAWING SHALL BE USED AS AN INSTRUMENT OF REFERENCE BY ALL OTHER TRADES AND CONTRACTORS. ALL TRADES SHALL VERIFY THE INFORMATION AS SHOWN ON THESE PLANS. FOR SPECIFIC CONNECTION INFORMATION, REFER TO THE ARCHITECT AND/OR CONTRACTOR'S DRAWINGS. 2. DIMENSIONS AND REQUIREMENTS FOR ALL EXISTING EQUIPMENT PROVIDED BY OTHERS MUST BE VERIFIED. 3. ALL NATIONAL, STATE AND LOCAL CODES SHALL APPLY. 4. THESE MECHANICAL REQUIREMENT DRAWINGS INDICATE THE LOCATION OF ALL UTILITIES REQUIRED AND RECOMMENDED FLOOR DRAINS BASED ON THE LAYOUT AND EQUIPMENT SPECIFIED. 5. ALL PLUMBING CONNECTIONS SHALL BE EXTENDED TO AND INTERCONNECTED TO ALL CONNECTION POINTS ON THE EQUIPMENT BY OTHERS. ALL HARDWARE REQUIRED FOR THESE CONNECTIONS SHALL BE SUPPLIED BY THE PLUMBING CONTRACTOR. 6. ONLY COMPONENTS SUPPLIED STANDARD BY THE MANUFACTURER ARE INCLUDED. ALL HARDWARE REQUIRED FOR CONNECTIONS SHALL BE SUPPLIED BY THE PLUMBING CONTRACTOR. SUCH COMPONENTS INCLUDE, BUT ARE NOT LIMITED TO, SHUT -OFFS, PRESSURE REGULATORS, VACUUM BREAKERS, P -TRAPS, BACKFLOW PREVENTERS, ETC. 7. ALL PLUMBING LINES SHALL BE EXTENDED THROUGH & OUT OF BUILDING WALLS WHERE POSSIBLE 8. PLUMBING CONTRACTOR TO VERIFY THAT ALL APPLIANCES ARE SUPPLIED WITH APPROPRIATE GAS PRESSURE AND THAT ANY VARIANCES IN GAS PRESSURE BE CLEARLY IDENTIFIED AND BROUGHT TO THE IMMEDIATE ATTENTION OF THE GENERAL COMPANIES. 9. PLUMBING CONTRACTOR TO VERIFY GAS PRESSURE REGULATOR REQUIREMENTS FOR ALL EQUIPMENT SHOWN ON THESE PLANS. 10. ALL INDIRECT WASTE AND CONDENSATE DRAIN LINES SHALL BE EXTENDED FROM EQUIPMENT FITTINGS TO APPROPRIATE DRAINS BY OTHERS. 11. HOT WATER SUPPLIED TO BOOSTER HEATER SHALL BE A MINIMUM TEMPERATURE OF 140' F. 12. PLUMBING CONTRACTOR TO VERIFY WATER TEMPERATURE REQUIREMENTS FOR EACH PIECE OF EQUIPMENT. ANY DISCREPANCY BETWEEN MANUFACTURER'S REQUIREMENTS AND TEMPERATURES PROVIDED SHALL BE CLEARLY IDENTIFIED AND BROUGHT TO THE IMMEDIATE ATTENTION OF THE GENERAL COMPANIES. 13. PLUMBING CONTRACTOR TO PROVIDE INSULATED CONNECTION BETWEEN BOOSTER HEATER AND DISHMACHINE. 14. UNLESS OTHERWISE NOTED, ALL DIMENSIONS SHOWN ON THIS PLAN ARE FROM THE FINISHED FLOOR, CEILING OR WALLS TO THE CENTERUNE OF THE ROUGH -IN. 15. UNLESS OTHERWISE SPECIFIED BY CODE, ALL DRAIN LINES FOR DISPOSERS SHALL BY-PASS GREASE INTERCEPTORS. PLUMBING PLAN THIS DRAWING IS AN NSTRI ENT OF SERVICE FDR OTHER CONTRACTORS. ALL DIMENSIONS TO BE VMFED ON THE JOB S E, AND CONTRACTORS SHOULD CHECK WITH EO MENT SUFPLER REGARDING ROIIGHNG N WORK. ALL DIMENSIONS ARE FROM FNISED FIAORS AND WADS. All. STUEIBNG TO BE 3• AEKHE FINISHED FIAORS Lum OT umm SPECFTED. xTuAL LOCATIONS OF BOOR DRAM SIBS AND LOCATION OF MWTNG EQUIPMENT AND GRFASE TRAPS TO BE DETERMNID W ARCWTECT OR ENGINEER. THS DRAWING AND SPECF0MNS ARE THE PROPERTY OF GENERAL HOTEL AND RESTAURANT RIPPLY ODRP, AND ARE NOT TO BE USED ON ANY WORK IN WHOLE OR IN PART EXCEPT BY WRITTEN AGREDIENT WITH GEHM HIOTEL AND RESTAURANT SUPPLY CORP. PLDLBNG AND ELECTRICAL LOCATIONS AS SHOWN ON PLAN ARE OF OUTLETS AS THEY EXIST ON TIMES. LECHNN A TRADES WLL MAKE ALLOWANCE FOR VARIOUS RITNGS TO TAKE CARE OF CGNNECRNG UP TO FIXTURE. ©COPYRIGHT 2008 ALL RIGHTS RESERVED REVISIONS - PLUMBING LEGEND 0 HOT WATER SUPPLY AFF: ABOVE FINISHED FLOOR • COLD WATER SUPPLY BFF: BELOW FINISHED FLOOR • DIRECT WASTE CW: COLD WATER C INDIRECT WASTE FD: FLOOR DRAIN ® GAS SUPPLY FS: FLOOR SINK SO: STUB OUT FLOOR SINK SU: STUB UP FLOOR DRAIN SD: STUB DOWN �— FIELD INTERCONNECTION PLUMBING PLAN THIS DRAWING IS AN NSTRI ENT OF SERVICE FDR OTHER CONTRACTORS. ALL DIMENSIONS TO BE VMFED ON THE JOB S E, AND CONTRACTORS SHOULD CHECK WITH EO MENT SUFPLER REGARDING ROIIGHNG N WORK. ALL DIMENSIONS ARE FROM FNISED FIAORS AND WADS. All. STUEIBNG TO BE 3• AEKHE FINISHED FIAORS Lum OT umm SPECFTED. xTuAL LOCATIONS OF BOOR DRAM SIBS AND LOCATION OF MWTNG EQUIPMENT AND GRFASE TRAPS TO BE DETERMNID W ARCWTECT OR ENGINEER. THS DRAWING AND SPECF0MNS ARE THE PROPERTY OF GENERAL HOTEL AND RESTAURANT RIPPLY ODRP, AND ARE NOT TO BE USED ON ANY WORK IN WHOLE OR IN PART EXCEPT BY WRITTEN AGREDIENT WITH GEHM HIOTEL AND RESTAURANT SUPPLY CORP. PLDLBNG AND ELECTRICAL LOCATIONS AS SHOWN ON PLAN ARE OF OUTLETS AS THEY EXIST ON TIMES. LECHNN A TRADES WLL MAKE ALLOWANCE FOR VARIOUS RITNGS TO TAKE CARE OF CGNNECRNG UP TO FIXTURE. ©COPYRIGHT 2008 ALL RIGHTS RESERVED REVISIONS - OA /07/09 LA'ZOUT 8 M EP S - PB Q 03/23/09FIRE Q ..112 O o00 V 8 a� i N i Lo :) 19 LL o 0 t7 L N o Luz Cd w- crn 7ZZ� a Ld Z�• Q L 'rn W 00 a _0� � c 19 00 L Lu ca z: w ..10� W C) C 0 '2 a v, w s 8 Z a Lu W �M}. V Q D c— Zcy) V WM LL ry Lo O < �: LL N U- o� N oQ 00 . DRAWN BY JTG CHECKED ENGINEERING DATE 12/21/08 SCALE 1/4"=1'-0" JOB NO. 2008131 SHEET FS -3 OF