09-97-045REVISIONS THE SENERfi COMPMIES THE GENERAL COMPANIES I REMOTE COMPRESSORS AND CONDENSING UNITS THESE NOTES APPLY TO MULTI -SYSTEM COMPRESSOR RACKS AS WELL AS INDIVIDUAL COMPRESSORS AND CONDENSORS. EXACT LOCATION OF COMPRESSORS ARE TO BE DETERMINED BY ARCHITECT. FREE & EASY ACCESS INTO AREA FOR COMPRESSORS MUST BE PROVIDED BY OTHERS, TO ALLOW PLACEMENT OF RACK AS WELL AS MAINTAIN MINIMUM CLEARANCE REQUIREMENTS. SUFFICIENT AIR CHANGES MUST BE PROVIDED IN THIS AREA TO ALLOW ADEQUATE AIR CIRCULATION FOR WATER COOLED OR AIR COOLED COMPRESSORS. STRUCTURAL SUPPORT FOR COMPRESSORS, ON ROOF OR INSIDE STRUCTURE, TO BE PROVIDED BY OTHERS. RRM COLPRESSOR J SEE MANUFACTURER'S SHOP DRAWINGS FOR DETAILED REQUIREMENTS FOR CLEARANCE, MECHANICAL, PLUMBING & ELECTRICAL REQUIREMENTS. FOR WATER COOLED UNITS, STRICT ADHERENCE TO MANUFACTURERS REQUIREMENTS FOR 208/60/1, 2.0 HP, JB 24' MIN./MAX. WATER TEMP AND PRESSURE MUST BE MAINTAINED. AFF (REFRIGERATION SYSTEM) EXISTING - VERIFY ASHRAE CALCULATIONS AND ANY RESULTING REQUIREMENTS FOR COMPRESSOR AREA, PIPING CHASES AND FREON DETECTION SYSTEMS SHALL BE THE RESPONSIBILITY OF OTHERS. ELECTRICAL NOTE: ALL REFRIGERANT PIPING CHASES AND BUILDING PENETRATIONS SHALL BE THE RESPONSIBILITY OF THE FOR EACH FREEZER COMPRESSOR, ELECTRICIAN TO PROVIDE (1) 3/4' DIAMETER CONDUIT BUILDING TRADES AND TO COMPLY WITH ALL LOCAL CODES. W/(5) #10 WIRES & INTERCONNECT BETWEEN COMPRESSOR, EVAPORATOR COIL & TIME EXACT LINE RUNS OF REFRIGERATION PIPING SHALL BE CLOCK. DETERMINED IN COORDINATION WITH THE REFRIGERATION INSTALLER. VERIFY ALL DETAILS WITH MANUFACTURERS LATEST SHOP DRAWINGS. J/1, 20.0 AMPS, JB, INTERCO INICATION SYSTEM -VERIFY ALL lEMENTS WITH MANUFACTURES DRAWINGS. BY OTHERS. 10'-9" 120/60/1, 20.0 AMPS, I JB ' AFF(DRIVE THRU MEkU) VERIFY ALL REQUIREMENTS WITH MANUFACTURES APPROV SHOR DRAWINGS. I � I / i-208/60/1, 30.0 AMPS, �\ ' JB 86' AFF (ICE MACHINE) \ O / \ / 120/60/1, 10.0`AMF Z) J I DO 72 AFF (SODA VERIFY WITH SUPPLIER � 1 L-J5­911 �120/60/1, 20.0 AMPS JB FROM ABOVE (LIGHTS, HEATER & ALAR 11 -4 J 120/60/1, 10.0 AMPS, k�e JB FROM ABOVE (COIL) n 220/60/1, 4.0 H.P JB 24- AFF (MIXER) 120/60/1, 10.0 AMPS, SR 12- AFF (REFRIGERATOR) 120/60/1, 20.0 AMPS, DO 48' AFF (UTILITY) 0 1 rimmiii I I 120/60/1, 1/4 H.P. SR 48' AFF (SUCER) ROOFTOP EXHAUST FANS & MAKE-UP AIR FANS NOTES: 1. THESE ITEMS ARE TO BE LOCATED BY THE ARCHITECT & IN CONJUNCTION WITH THE EXHAUST HOOD MANUFACTURER'S SHOP DRAWING. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATION. 2. ALL PENERATKONS THRU ROOF OR BUILDING STRUCTURE, INCLUDING JOISTS OR OTHER STRUCTURAL MEMBERS, IS TO BE BY OTHERS. L-120/60/1, 20.0 AMPS, DO 48- AFF(UTIUTY) 120/60/1, 3/4 H.P, INTER 48' AFF (DOUGH ROLLER) 120/60/1, 15.0 AMPS, SWIT( SR 37- AFF (CONVEYOR MANU E�T SUPPLY J J FAN 120/60/1 120/60/1 .75 HP .75 HP NOTE. ELECTRICAL CONTRACTOR SHALL PROVIDE WIRE, CONDUIT AND DISCONNECTS TO EXHAUST & SUPPLY FANS LOCATED ON ROOF (LOCATION TO BE DETERMINDED BY OTHERS) W/INTERCONNECTIONS TO SWITCHES BELOW. SEE MANUFACTURERS SHOP DRAWING FOR COMPLETE ELECTRICAL DETAILS. TO 120/60/1, 20.0 DO STUB UP TO S, (EA), SNB DOWN TO FAN AS REQUIRED INCL fl�sHVERIFY ALL RE o DRAWINGS. 1 1 I raAF,aE�--- I I RVI DO 24-GAFF -(P.O.S) JB 24' AFF, (SODA & IC SPENSER) FROM JB EXTEND OUTLET, (2)120/60/1, 10.0 AMPS EA., SR 24 AFF, EXTEND THRU CABINET TO REFRIGERATOR. FROM JB EXTEND OUTLET, 120/60/1, 20.0 AMPS, DO 24- AFF, EXTEND THRU CABINET TO P.O.S. FROM JB EXTEND OUTLET, (2)120/60/1, 20.0 AMPS EA., SR 24' AFF, EXTEND THRU CABINET TO FUTURE EQUIPMENT. 120/ 1, 1 AMPS, AFF MACHINE) 120/6 15.0 AMPS, JB 48' AFF,(SODA & ICE I PEI �I I I I 11 11 �! I I I \I 11 11 I I I I I I I I i.ilillll/i, j r f• USI () Z Alf I� - - I ELECTRICAL NOTES ' 1. THIS DRAWING SHALL BE USED AS AN INSTRUMENT OF REFERENCE BY ALL OTHER TRADES AND CONTRACTORS. ALL TRADES SHALL VERIFY THE INFORMATION AS SHOWN ON THESE PLANS. FOR SPECIFIC CONNECTION INFORMATION, REFER TO THE ARCHITECT AND/OR CONTRACTOR'S DRAWINGS. 2. DIMENSIONS AND REQUIREMENTS FOR ALL EXISTING EQUIPMENT PROVIDED BY OTHERS MUST BE VERIFIED. 3. ALL NATIONAL, STATE AND LOCAL CODES SHALL APPLY. 4. THESE MECHANICAL REQUIREMENT DRAWINGS INDICATE THE LOCATION OF ALL UTILITIES REQUIRED AND MINIMUM UTILITY OUTLETS BASED ON THE EQUIPMENT SPECIFIED. 5. ALL UTILITY OUTLEIS TO BE G.F.C.I. OUTLETS. 6. ALL ELECTRICAL CONNECTIONS SHALL BE EXTENDED TO AND INTERCONNECTED TO CONNECTION POINTS ON THE EQUIPMENT BY OTHERS. ALL HARDWARE REQUIRED FOR THESE CONNECTIONS SHALL BE SUPPLIED BY THE ELECTRICAL CONTRACTOR. 7. ALL ELECTRICAL LINES SHALL BE EXTENDED THROUGH AND OUT OF BUILDING WALLS WHERE POSSIBLE 8. ALL NECESSARY ELECTRICAL DISCONNECTS, SHUNT TRIP BREAKERS AND STARTERS TO BE FURNISHED AND INSTALLED BY OTHERS, UNLESS PROVIDED AS A STANDARD EQUIPMENT COMPONENT OF THE EQUIPMENT BY THE MANUFACTURER. 9. ALL ELECTRICAL ITEMS SUPPLIED UNDER COOKING LINE EXHAUST HOOD TO SHUT DOWN WITH SHUNT TRIP (BY OTHERS) TIED IN TO HOOD SYSTEM. ELECTRICAL ENGINEER TO CONFIRM COMPLIANCE TO ALL CODES. 10. ALL JUNCTION BOXES, DISCONNECTS, ETC. SHALL BE INSTALLED SO AS NOT TO INTERFERE WITH THE PERFORMANCE, FUNCTION, OR PLACEMENT OF THE EQUIPMENT. 11. ALL EQUIPMENT SHALL BE WIRED IN STRICT CONFORMANCE WITH THE MANUFACTURER'S INSTRUCTIONS AND/OR SHOP DRAWINGS. 12. STARTERS. RELAYS, HEATERS AND SWITCHES REQUIRED FOR EXHAUST AND SUPPLY FANS ARE TO BE PROVIDED AND INSTALLED BY THE ELECTRICAL CONTRACTOR. 13. ELECTRICAL CONTRACTOR SHALL INTERCONNECT DISHMACHINE WITH DISHMACHINE EXHAUST FAN. INTERCONNECTION SHALL LINK OPERATION OF EXHAUST FAN TO OPERATION OF DISHMACHINE SO THAT BOTH UNITS RUN SIMULTANEOUSLY AT ALL TIMES. 14. ELECTRICAL CONTRACTOR SHALL INTERCONNECT TABLE LIMIT SWITCH AT END OF CLEAN DISHTABLE WITH CONVEYOR TYPE DISHMACHINES. INTERCONNECTION SHALL TERMINATE DISHMACHINE OPERATION WHEN DEPRESSED. 15. WALK-IN COOLER/FREEZER COMPRESSORS: a. INTERCONNECT TO BLOWER COIL IN FREEZER. b. INTERCONNECT BETWEEN TIMER & CONTACTOR. c. INTERCONNECT BETWEEN TIMER & PRESSURE CONTROL SOLENOID. d. INTERCONNECT BETWEEN CONTACTOR AND COMPRESSOR FAN. e. INTERCONNECT BETWEEN TERMINAL AND CONTACTOR TO BLOWER COIL IN FREEZER BOX. 16. WALL( -IN COOLER/FREEZER BOX: a. ALL ELECTRICAL CONDUIT TO BE RUN ON TOP (EXTERIOR) OF WALK-IN BOX. 17. WALK-IN FREEZER BOX: a. CONNECT DRAIN LINE HEATER TO TERMINAL STRIP. b. CONNECT PAN HEATER TO TERMINAL STRIP. C. CONNECT DOOR HEATER TO TERMINAL STRIP. 18. UNLESS PROVIDED BY THE MANUFACTURER, ALL LIGHT BULBS FOR FOODSERVICE EQUIPMENT TO BE PROVIDED BY OTHERS. 19. UNLESS OTHERWISE NOTED, ALL DIMENSIONS SHOWN ON THIS PLAN ARE FROM THE FINISHED FLOOR, CEILING OF WALLS TO THE CENTERUNE OF THE ROUGH -INS. ELECTRICAL LEGEND JD JUNCTION BOX (HARD WIRE) d) SINGLE RECEPTACLE (CORD & PLUG) DUPLEX OUTLET (CORD & PLUG) FIELD INTERCONNECTION (CONCEALED) AFF: ABOVE FINISHED FLOOR SO: STUB OUT AMP: AMPERE SR: SINGLE RECEPTACLE DO: DUPLEX OUTLET SU: STUB UP HP: HORSEPOWER W: WATT SD: STUB DOWN ELECTRICAL PLAN TM DRAWING 6 AN IN5I WMW OF SERVICE FOR UM CONTRACTORS. ALL D ENMNS TO BE VERM ON TETE JOB SITE, AND CONTRACTORS WU CHECK WITH EOUIPNEK SUPPLER REGARDING ROUGHING N WORK. ALL DWSONS ARE FROM Fimm FLOORS AND WALLS. ALL SRIBBNG TO BE 3' ABOVE FINI FLOORS UNLESS OTIUMSE SPECFG. ACRIAL LOCATIONS OF FLOOR DRAINS, SIZES AND LOCATION OF VENTILATING EDUIPIENT AND (PEASE TRAPS TO BE DEIFRWIND BY ARCH= OR DOUR. THIS DRAWING AND SPECFICATIONS ARE THE PROPERTY OF GENERAL HOTM AND RESTAURANT SUPPLY CORP., AND ARE NOT TO BE USED ON ANY WORK IN WHOLE OR IN PART EXCEPT BY WRITTEN AGREDW WITH GENERAL HOTEL AND RESTAIIRAK SUPPLY CORP. RLLW G AND ELECTRICAL LOCATIONS AS SHOWN ON PLAN ARE OF OUTLETS AS THEY DOST ON FIXTURES. MECHAWCAL TRADES WILL MAKE ALLOWANCE FOR VARIOUS FITTINGS TO TAIL CARE OF CONNECTFIG UP TO FIXTURE _ ©COPYRIGHT 2008 ALL RIGHTS RESERVED mj d 010 N 00 ci o 49 t N w�� U ?i -U) Q xal Z�L�� LLI 9La rn c � 0 (o Q woo Zj- Q L 'ol W 00 Lu aci c �i cN0 if W0.6 joc30 w w o 0 o a r W i U w z w 0 w W� V D r Z� U wM a U iso }� u- Niv♦C- C:) G N=od O.C.0 2 DRAWN BY JTG CHECKED ENGINEERING DATE 12/21/08 SCALE 1/411=1 1-001 /4"=1'-011 JOB NO. 2008131 SHEET FS -2 OF