Loading...
09-97-042'THE GENERAL COMPANIES - - - THE GENER Al- CJMPANIES REMOTE COMPRESSORS AND CONDENSING UNITS THESE NOTES APPLY TO MULTI -SYSTEM COMPRESSOR RACKS AS WELL AS INDIVIDUAL COMPRESSORS AND CONDENSORS. EXACT LOCATION OF COMPRESSORS ARE TO BE DETERMINED BY ARCHITECT. FREE do EASY ACCESS INTO AREA FOR COMPRESSORS MUST BE PROVIDED BY OTHERS, TO ALLOW PLACEMENT OF RACK AS WELL AS MAINTAIN MINIMUM CLEARANCE REQUIREMENTS. c � N c t v C M X � N y L � L tD Q 00 a C) c; 00 0 00 O M i d N Y 22 RELm COW'RESSOR 1 DISPLAY PANEL SUFFICIENT AIR CHANGES MUST BE PROVIDED IN THIS AREA TO ALLOW ADEQUATE AIR CIRCULATION FOR WATER COOLED OR AIR COOLED COMPRESSORS. STRUCTURAL SUPPORT FOR COMPRESSORS, ON ROOF OR INSIDE STRUCTURE, TO BE PROVIDED BY OTHERS. SEE MANUFACTURERS SHOP DRAWINGS FOR DETAILED REQUIREMENTS FOR CLEARANCE, MECHANICAL, PLUMBING & ELECTRICAL REQUIREMENTS. FOR WATER COOLED UNITS, STRICT ADHERENCE TO MANUFACTURERS REQUIREMENTS FOR MIN./MAX. WATER TEMP AND PRESSURE MUST BE MAINTAINED. ASHRAE CALCULATIONS AND ANY RESULTING REQUIREMENTS FOR COMPRESSOR AREA, PIPING CHASES AND FREON DETECTION SYSTEMS SHALL BE THE RESPONSIBILITY OF OTHERS. ALL REFRIGERANT PIPING CHASES AND BUILDING PENETRATIONS SHALL BE THE RESPONSIBILITY OF THE BUILDING TRADES AND TO COMPLY WITH ALL LOCAL CODES. EXACT UNE RUNS OF REFRIGERATION PIPING SWILL BE DETERMINED IN COORDINATION WITH THE REFRIGERATION INSTALLER. EQUIPMENT SCHEDULE 01/07/09 J.YoU 3 J:: , 3 - PB - 0 03/12/09 WASA & FIRE 0 03/23/09 FIRE Q ITEM QTY DESCRIPTION ITEM QTY DESCRIPTION ITEM QTY IDESCRIPTION 1 1 EA DRIVE THRU MENU BOARD 24 6 EA MOBILE PAN RACK 47 1 EA POS STATION FOR DRIVE THRU (BY OTHERS) 2 1 EA MENU BOARD COMMUNICATIONS SYSTEM (BY OTHERS) 25 1 LT STORAGE SHELVING UNIT - 5 TIER, EPDXY 48 1 EA CASH DRAWER--, 3 1 EA CO2 TANK (BY OTHERS) 26 1 EA SLICER 49 1 EA WALL MOUNfEQr(XEAStjELF 4 1 EA ICE MACHINE W/BIN 27 1 EA WORKTABLE W/ WALL MOUNTED DOUBLE OVERSHELF 50 OPEN NUMB4R 5 1 EA WATER FILTER FOR ITEM #4 28 1 EA CAN OPENER 51 1 EA TRASH REC T CLE 6 1 EA JANITOR'S SINK 29 1 EA 60 CIT MIXER 52 1 EA HAND SINK (O P & TOVVELNPtkSER BY OTHERS) 7 1 EA JANITOR'S FAUCET 30 OPEN NUMBER 53 1 EA EXHAUST HO DE 8 1 EA MOP HANGER 31 1 EA PIZZA TOP REFRIGERATOR 54 1 EA DOUBLE DEC< F IZZA OVEN 9 OPEN NUMBER 32 1 EA CUSTOM 19' CUTTING BOARD 55 2 EA UNDERCOUN FEk REFRIGERATOR 10 OPEN NUMBER 33 OPEN NUMBER 56 1 EA CUTTING BOR TOP 11 1 EA HAND SINK SOAP & TOWEL DISPENSER BY OTHERS 34 1 EA DOUGH ROLLER 57 1 EA PIZZA BAR DI 3PLAY COUNTER (BY OTHERS 12 1 EA THREE COMPARTMENT SINK 35 1 EA IWORKTABLE W/ SINK & WALL MOUNTED DOUBLE OVERSHELF 58 1 EA POS AND PR N ER STATION BY OTHERS 13 1 EA SPLASH MOUNTED FAUCET 36 1 EA SPLASH MOUNTED FAUCET 59 1 LT UNDERCOUN TEl I CUP AND LID DISPENSER 14 1 EA DOUBLE WALL SHELF 37 1 EA CONVEYOR PIZZA OVEN 60 OPEN NUMB R 15 OPEN NUMBER 38 1 EA EXHAUST HOOD 61 2 EA UNDERBAR F EF RIGERATOR W/ GLASS DOORS 16 1 EA SAFE (BY OTHERS) 39 1 EA WORKTABLE W/ TABLE MOUNTED OVERSHELF 62 1 EA CONDIMENT O NTER (BY OTHERS) 17 1 LT STORAGE SHELVING UNIT - 5 TIER, EPDXY 40 IOPEN NUMBER 63 1 EA BEVERAGE CIOL NTER (BY OTHERS) 18 1 LT STORAGE SHELVING UNIT - 2 TIER EPDXY - ABOVE ITEM #19 41 OPEN NUMBER 64 1 EA ICE MACHIN F R ITEM #65 19 1 EA SODA SYSTEM (BY OTHERS) 42 1 EA EXHAUST FAN FOR ITEM # 38 & ITEM # 53 65 1 1 EA SODA & ICE I IS ENSER 20 OPEN NUMBER 43 1 EA SUPPLY AIR FAN FOR ITEM # 38 & ITEM # 53 66 1 EA WATER FILT R OR ITEM #64 AND #65 21 1 EA WALK-IN COOLER 44 1 EA ICE BIN AND SODA DISPENSER 67 OPEN NUMB R 22 1 EA MED TEMP REFRIGERATION SYSTEM EXISTING -VERIFY 45 1 EA WALL MOUNTED OVERSHELF 68 1 EA SEATING PA GE (BY OTHERS) 23 1 LT STORAGE SHELVING UNIT - 4 TIER, EPDXY 46 1 1 1 EA ICOUNTER 69 OPEN NUMB R STORAGE SHELVING - 5 TIER, EPDXY LANDSCAPE ROOFTOP EXHAUST FANS & MAKE-UP AIR FANS NOTES: 1. THESE ITEMS ARE TO BE LOCATED BY THE ARCHITECT & IN CONJUNCTION WITH THE EXHAUST HOOD MANUFACTURER'S SHOP DRAWING. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATION. 2. ALL PENETRATIONS THRU ROOF OR BUILDING STRUCTURE, INCLUDING JOISTS OR OTHER STRUCTURAL MEMBERS, IS TO BE BY OTHERS. E�T SUPPLY FAN 42 43 DRIVE-THRU PICK UP WINDOW L- — — — — ————— —— —————— — — — — —— I GENERAL NOTES 1. THIS DRAWING SHALL BE USED AS AN INSTRUMENT OF REFERENCE BY ALL OTHER TRADES AND CONTRACTORS. ALL TRADES SHALL VERIFY THE INFORMATION AS SHOWN ON THESE PLANS. FOR SPECIFIC CONNECTION INFORMATION, REFER TO THE ARCHITECT AND/OR CONTRACTOR'S DRAWINGS. 2. DIMENSIONS AND REQUIREMENTS FOR ALL EXISTING EQUIPMENT PROVIDED BY OTHERS MUST BE VERIFIED. 3. ALL NATIONAL, STATE AND LOCAL CODES SHALL APPLY. 4. ALL DIMENSIONS AND SYMBOLS ON THESE PLANS ARE BASED ON FINISHED WALL AND FLOOR DIMENSIONS. ANY DISCREPANCIES BETWEEN THESE DRAWINGS AND ACTUAL OR INTENDED CONDITIONS IN THE FIELD SHOULD BE REPORTED TO THE GENERAL COMPANIES IMMEDIATELY. 5. ARCHITECT TO LOCATE, GENERAL CONTRACTOR TO PROVIDE ALL ROOF/BUILDING PENETRATIONS AND CURBS FOR DXHAUST/SUPPLY AIR SYSTEMS AND REMOTE COMPRESSORS. 6. ARCHITECT TO LOCATE All. REMOTE COMPRESSORS AND CONDENSERS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. 7. UNLESS OTHERWISE NOTED ALL DIMENSIONS SHOWN ON THIS PLAN ARE FROM THE FINISHED FLOOR, CEILING OR WALLS TO THE CENTERLINE OF THE ROUGH -INS. EQUIPMENT LAYOUT PLAN THIS DRAPING 5 AN NSIRUIEM OF SERVICE FOR OTHER CONTRACTORS. ALL OIMDWIS TO BE VEMFED ON THE JOB SITE, AND CMACTORS SHOULD CHECK WITH EQUIPMENT SUPPLER REGARDING ROUGHING N WORK ALL DWISM ARE FROM MOO FLOORS AND WALLS. ALL SRIBBNG TO BE 3' ABODE Mme FLOORS MEM OTHERWISE SPECIFIED. ACIUAL LOCATIONS OF FLOOR MARC, SIZES AND LOCATION OF VWWTNG EOUIPMEWT AND GREASE TRAPS TO BE DETFRWIM BY ARCHITECT OR DI EER. THIS DRAWNG AND SPECFICATIOIS ARE THE PROPERTY OF GENERAL HOTEL AND RESTAURANT SLA'PLY CORP. AW ARE NOT TO BE USED ON ANY WORK N WHALE OR N PART EXCEPT BY WRITTEN AGR DENT WITH GENERAL HOTEL AND RESTAURANT SUPPLY CORP. PLLAA3NG AND ELECTRICAL. LOCATIONS AS SHO" ON PLAN ARE OF OUTLETS AS THEY EXIST ON FOOURES. LECHAHAX TRAM WILL HALO: ALLOWANCE FOR VARKIUS RTINGS TO TAKE CARE OF CONNECTNG LLP TO FIXTURE ©COPYRIGHT 2008 ALL RIGHTS RESERVED REVISIONS 01/07/09 J.YoU 3 J:: , 3 - PB - 0 03/12/09 WASA & FIRE 0 03/23/09 FIRE Q mj a 0 00 `V O O 1 /' Q N E 19 iL Ly o 0 ,w 0 L_ Y/ v O Q x ZMLL. � ujrn �� a wZ oo °' ZH ¢ Lo 'o+ W �o 0 c CV 00 u LLIw .j C) ci W o C 0 O �2 W W Z w W r W M d' Q :� Z cy) (� W M U) Qo �O U-) _J �LL Q � N O:E N OQ CL co75 DRAWN BY JTG CHECKED ENGINEERING DATE 12/21/08 SCALE 114'.',. 1'-0" JOB NO. 2008131 SHEET FS - 1 OF