VENTING MUST
COMPLY WCffi---
NATIONAL
CODES, LOCAL
CODES AND
MANUFACTURER'S
INSTRUCTIONS
RELIEF
VALVE
HOT
•
6" THICK BY 18" SQUARE
CONCRETE PAD
GRADE OR PAVING
SEE
PLANS
CAST IRON OR PVC
CLEANOUT
WITH COVER FOR
DUTY REQUIRED
CAST IRON OR PVC
EXTENSION -SAME
SIZE AS SEWER
UP TO 4" DIA.
CAST IRON OR PVC SINGLE
TWO-WAY CLEANOUT
FLOW
-W BUILDING DRAIN OR
EXTERIOR CLEANOUT SEWER MATERIAL AND
(LIGHT TRAFFIC AREA) SIZE AS SPECIFIED
CEMENT BED TILE FLOOR
CONCRETE FILL —71
STRUCTURAL SLAB
TFGiU OUISIDE WAIF
TANKLESS
WATER
HEATER
:2w
OF g
FLOOR DRAIN
UL APPROVED
-VENT PIPE
TY -SEAL
ATTACHMENT
D E'-
PLATE
GAS GAS SUPPLY UNE
SHUTOFF (CHECK RATING PLATE FOR
VALVE CORRECT GAS TYPE AND
PRESSURE)
NOTES:
-WATER HEATER MUST BE INSTALLED TO CONFORM WITH CURRENT
NATIONAL ELECTRIC CODE, NATIONAL FUEL GAS CODE, AND ANY
APPUCABLE LOCAL PLUMBING, ELECTRICAL. HEATING AND AIR
CONDITIONING CODES, AND MANUFACTURER INSTALLATION
INSTRUCTIONS
-PROTECT HEATER FROM FREEZING
-SPECIFY NATURAL GAS OR PROPANE
TANKLE55 GA5 NATER HEATER
NTS
CHROME WALLCOVER
& SCREW
WATERPROOF
MEMBRANE
FINISHED FLOOR
CAST IRON OR PVC
EXTENSION -SAME
SIZE AS SEWER
UP TO 4" DIA.
CAST IRON OR PVC
LONG SWEEP
1/4 BEND OR CAST IRON
COMB, "Y" & 1/8 BEND.
(USE REDUCING TYPE
-flfl--DWHERE REQUIRED)
INTERIOR FLOOR CLEANOUT
L OF CLEQNOU I
MAY EXTEND AS A
WASTE OR VENT
— WALL
PLUGGED TEE W/
CLEANOUT
FLOOR LINE
1/8"C.I. BEND
BALANCE OF PIPING SAME
AS CLEANOUT TO GRADE.
CLEANOUT
PLUMBING LEGEND
CO
CLEAN OUT
C.O.T.G.
CLEAN OUT TO GRADE
CW
DOMESTIC COLD WATER
HW
DOMESTIC HOT WATER
VTR
VENT THRU ROOF
DN
DOWN
WHA
WATER HAMMER ARRESTER- PDI #
SOV
SHUT-OFF VALVE
Q US
CHECK VALVE
>4
GATE VALVE OR BALL VALVE
—4+
HOSE BIBB WITH VACUUM BREAKER
u,
T o
DOMESTIC COLD WATER PIPING
— — — —
DOMESTIC HOT WATER PIPING (110°F)
140
DOMESTIC HOT WATER PIPING (140°F)
GAS
DOMESTIC L.P/N.G.. GAS PIPING
COND
CONDENSATE WATER PIPING
— — — — — —
VENT PIPING
lz= Li + J
SANITARY WASTE WATER PIPING
t'
IW
IN -DIRECT SANITARY WASTE WATER PIPING
GW
GREASE WASTE WATER PIPING
PIPE DROP DOWN
^
PIPE RISER UP
El
CAPPED END OF PIPE
DO
P -TRAP
Wo c�
CLEAN OUT
FLOOR DRAIN®
�FD
FLOOR SINK W/ 1/2 GRATE
FS
FUNNEL FLOOR DRAIN
FFD
ROOF DRAIN
RD
rrrctZibUrct UKUt : U.a vvc.
SPECIFIC GRAV.: 0.60
FLOOR PLAN - WATER/GAS
SCALE: 1/4"= V-0"
-,FLOOR PLAN - SANITARY
SCALE: 1/4"= 1'-0"
001
1
Y�Ry.
ALL IDEAS, DESIGNS, ARRANGEMENTS, AND PLANS INDICATED OR
REPRESENTED BY THIS DRAWING ARE OWNED BY, AND THE PROPERTY OF
TECTONICS ASSOCIATES, INC. AND WERE CREATED, EVOLVED AND
DEVELOPED FOR USE ON, AND IN CONNECTION WITH THE SPECIFIED
PROJECT. NONE OF SUCH IDEAS, DESIGNS, ARRANGEMENTS OR PLANS
SHALL BE USED BYOR DISCLOSED TO ANY PERSON, FIRM OR CORPORATION
FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF
TECTONICS ASSOCIATES, INC.
WRITTEN DIMENSIONS OF THESE DRAWINGS SHALL HAVE PRECEDENCE
OVER SCALED DIMENSIONS. CONTRACTORS SHALL VERIFY, AND BE
RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB AND THIS
OFFICE MUST BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND
CONDITIONS SHOWN BY THESE DRAWINGS. SHOP DETAILS MUST BE
SUBMITTED TO THIS OFFICE FOR APPROVAL BEFORE PROCEEDING WITH
FABRICATION.
i
705020
i—
U Ln
W T
U��rn
Q< <"L0
0:U
~WW�
w0�}
73 -3
O
LL':
�Q
�O
{ J
Q
N w
N
O
CSO
date :12-10-08
0
E
2
E
J,
v
C1
C
O
REVISED BY: ONE D+B
project number
08146
sheet
P-1
of
6
JU)
D
_
A
Ul N
Cl)
J
Q US
u,
T o
IC J LL,
I
�J=�
C, �
i
Z J C0 V
t
lz= Li + J
t'
Co Q LL C
U
1
v)
W+-2LOD
�i 'j Q m m
FW-
�a+
XCOZ
Wo c�
Z =
�C, Zco 00c
o O
=Q co a0
705020
i—
U Ln
W T
U��rn
Q< <"L0
0:U
~WW�
w0�}
73 -3
O
LL':
�Q
�O
{ J
Q
N w
N
O
CSO
date :12-10-08
0
E
2
E
J,
v
C1
C
O
REVISED BY: ONE D+B
project number
08146
sheet
P-1