09-97-034a 0 0 4 cyl0 0 N M 3 v N a. LL, 00 nIR CU (U v E c CT M C X 4 p to v- (' .-4 00 CL 0000 O O M tV Y MECHANICAL NOTES: DUCTWORK ONLY. EXISTING RTU'S TO REMAIN. INSTALL SUPPLY AND RETURN DUCTS AND GRILLES AS SHOWN. INSTALL DUCT SMOKE DETECTOR ON RTU #1 IN DINING AREA. PLACE BOTH THERMOSTATS IN OFFICE, PLACE REMOTE SENSORS IN RETURN DUCT. DUCTWORK SHALL HAVE R-6 FIBERGLASS INSULATION AND BE INSTALLED IN ACCORDANCE WITH SMACNA HVAC DUCT CONSTRUCTION STANDARDS, LATEST EDITION. EXCEPTION: DUCT 1N CONDITIONED SPACE (SUCH AS, BETWEEN FLOORS OF CONDITIONED SPACES) MAY BE R-4.2. (FBC TABLE 13-410.1.ABC.2.2) ALL ROOFTOP CONDENSATE DRAINS TO BE SUPPORTED EVERY 4 FEET, MAXIMUM, AND ARE TO DRAIN INTO PERMEABLE SOIL 12 INCHES, MINIMUM, FROM BUILDING STRUTURE. (FMC305.4, 307.2) HVAC DESIGN REQUIRES: YES NO DUCT SMOKE DETECTOR # OF PEOPLE CFM / PERSON FIRE DAMPERS A/C # SUPPLY DUCT SMOKE DAMPERS 70 MANUAL VOLUME DAMPER FIRE RATED ENCLOSURE TAB COLLAR W/ 1120 FIRE RATED ROOF/FLOOR CEILING ASSEMBLY ADJUSTABLE DAMPER LOW PRESSURE R-6 INSULATED FIRE STOPPING DUCT I FLEXIBLE DUCT SMOKE CONTROL FLEXIBLE DUCT: SEE HVAC PLAN FOR SIZE TAPE TAB COLLAR TO DUCT BOARD EXISTING EQUIPMENT SCHEDULE UNIT #1 - TRANE RTU MODEL: TCH092A3 - 7 -1/2 -TON UNIT #2 - TRANE RTU MODEL: TCH060A3 - 5.0 -TON SPLIT SYSTEM - TRANE MODEL: TTA120A3 AND AHU MODEL: TWE120A3, A 10.0 -TON SYSTEM ARE EXISTING BUT NOT USED NEW BATH EXHAUST FAN EF -1 NUTONE (or equiv) MODEL - QT150 160 CFM VOLTS - 120 0.60 AMPS 2.5 SONES 6" DUCT NOTE AREA PEOPLE/ 1,000 S.F. HANG DUCT PER SMACNA STANDARDS # OF PEOPLE CFM / PERSON MIN. CFM REQ. A/C # SUPPLY DUCT DINING AREA 70 MANUAL VOLUME DAMPER 56 TAB COLLAR W/ 1120 RTU #1 ADJUSTABLE DAMPER LOW PRESSURE R-6 INSULATED 20 DUCT I FLEXIBLE DUCT TYPICAL Z -BAR & WIRE FLEXIBLE DUCT: SEE HVAC PLAN FOR SIZE TAPE TAB COLLAR TO DUCT BOARD HANGER DETAIL REMARKS: OPEN O.A. INTAKES OF RTU #1 TO 25%, OPEN RTU #2 TO 25% TO SUPPLY A TOTAL OF 1250 CFM DUCT WITH FOIL TAPE. SECURE INNER Z W SLEEVE TO TAB COLLAR WITH C N "PANDUIT' STRAP AND FOIL TAPE. TAPE 00 a ® OUTER INSULATED SLEEVE TO DUCT O~'w OUR FLOW BOARD WITH FOIL TAPE AND MASTIC. TAPE TAB COLLAR TO DUCT BOARD DUCT WITH FOIL TAPE. SECURE INNER TYPICAL HANGING STRAP SLEEVE TO TAB COLLAR WITH CEILING AND SADDLE DETAIL "PANDUIT' STRAP AND FOIL TAPE. TAPE DIFFUSER OR OUTER INSULATED SLEEVE TO DUCT GRILLE BOARD WITH FOIL TAPE AND MASTIC. INSULATED SQUARE BOX FORSQUARENECK DIFFUSER OR DIFFUSERS TYPICAL CHANNEL AND WIRE ROUND UND N CK WITH REDUCER HANGER DETAIL ED TYPICAL DUCT SUPPORT DETAILS FLEX DUCT DETAILS TYPICAL CONNECTION TO AIR DIFFUSER NOT TO SCALE NOT TO SCALE SCALE: NTS SUPPLY AND RETURN DUCT UP TO A AHU-1 @ ROOF OUTSIDE AIR REQUIREMENTS AREA PEOPLE/ 1,000 S.F. AREA IN S.F. # OF PEOPLE CFM / PERSON MIN. CFM REQ. A/C # OUTSIDE AIR PROVIDED DINING AREA 70 798 56 20 1120 RTU #1 1120 KITCHEN / PREP 20 415 8 15 160 RTU #2 120 REMARKS: OPEN O.A. INTAKES OF RTU #1 TO 25%, OPEN RTU #2 TO 25% TO SUPPLY A TOTAL OF 1250 CFM MECHANICAL PLAN SCALE: 1/4" = 1'-0" ell AIR CONDITIONING KEY ® SUPPLY DIFFUSER RETURN DIFFUSER sn SMOKE DUCT DETECTOR ® THERMOSTAT ® REMOTE SENSOR REMOTE TEST STATION U 02 W O VOLUME DAMPER P FIRE DAMPER F.D. 0 T— RADIATION DAMPER R.D. REFRIGERANT LINE CONDENSATE LINE RCS CONTRACTOR SERVICES, INC. 1798 NW 39TH COURT M r" OAKLAND PARK, FLORIDA 33309 BROWARD: 954-295-2182 ALL IDEAS, DESIGNS, ARRANGEMENTS, AND PLANS INDICATED OR REPRESENTED BY THIS DRAWING ARE OWNED BY, AND THE PROPERTY OF TECTONICS ASSOCIATES, INC. AND WERE CREATED, EVOLVED AND DEVELOPED FOR USE ON, AND IN CONNECTION WITH THE SPECIFIED PROJECT. NONE OF SUCH IDEAS, DESIGNS, ARRANGEMENTS OR PLANS SHALL BE USED BYOR DISCLOSED TO ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF TECTONICS ASSOCIATES, INC. WRITTEN DIMENSIONS OF THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. CONTRACTORS SHALL VERIFY, AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB AND THIS OFFICE MUST BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. SHOP DETAILS MUST BE SUBMITTED TO THIS OFFICE FOR APPROVAL BEFORE PROCEEDING WITH FABRICATION. N M ch J L 20 a� V J J � O N o m aLL o J + �n Z awm =mZ W m "� �zm coo W (0 N Z.+z Q ch a o 705020 i– Q U LO i-- y: QI W U 02 W O .� W U 0 Ogg F><- 0 U- Z W d Q O C N 0 0 J LL date 12-10-08 REVISED BY: ONE D+B 4 03/23/09 FIRE project number 08146 sheet M-1 or Q (n 0 LL 0 F><- 0 Z W d Q O C N o 00 a N � O~'w (I oCo date 12-10-08 REVISED BY: ONE D+B 4 03/23/09 FIRE project number 08146 sheet M-1 or