09-97-033R. N r� 0 rn 0 0 N ip tn 3 v v a w 00 (us E Cto C: M c X � N Ln u �a c'i 00a O O O O O M MECHANICAL NOTES: DUCTWORK ONLY. EXISTING RTU'S TO REMAIN. INSTALL SUPPLY AND RETURN DUCTS AND GRILLES AS SHOWN. INSTALL DUCT SMOKE DETECTOR ON RTU #1 IN DINING AREA. PLACE BOTH THERMOSTATS IN OFFICE, PLACE REMOTE SENSORS IN RETURN DUCT. DUCTWORK SHALL HAVE R-6 FIBERGLASS INSULATION AND BE INSTALLED IN ACCORDANCE WITH SMACNA HVAC DUCT CONSTRUCTION STANDARDS, LATEST EDITION. EXCEPTION: DUCT IN CONDITIONED SPACE (SUCH AS, BETWEEN FLOORS OF CONDITIONED SPACES) MAY BE R-4.2. (FBC TABLE 13-410.1.ABC.2.2) ALL ROOFTOP CONDENSATE DRAINS TO BE SUPPORTED EVERY 4 FEET, MAXIMUM, AND ARE TO DRAIN INTO PERMEABLE SOIL 12 INCHES, MINIMUM, FROM BUILDING STRUTURE. (FMC305.4, 307.2) HVAC DESIGN REQUIRES: YES NO DUCT SMOKE DETECTOR HANG DUCT PER SMACNA STANDARDS sn FIRE DAMPERS ® THERMOSTAT SMOKE DAMPERS REMOTE SENSOR TAB COLLAR W/ FIRE RATED ENCLOSURE - ADJUSTABLE DAMPER LOW PRESSURE FIRE RATED ROOF/FLOOR CEILING ASSEMBLY FIRE DAMPER DUCT _ FIRE STOPPING v— FLEXIBLE DUCT: ~' SMOKE CONTROL YPICAL Z -BAR & WIRE SEE HVAC PLAN FOR SIZE ;" EXISTING EQUIPMENT SCHEDULE UNIT #1 - TRANE RTU MODEL: TCH092A3 - 7 -1/2 -TON UNIT #2 - TRANE RTU MODEL: TCH060A3 - 5.0 -TON SPLIT SYSTEM - TRANE MODEL: TTA120A3 AND AHU MODEL: TWE I20A3, A 10.0 -TON SYSTEM ARE EXISTING BUT NOT USED NEW BATH EXHAUST FAN EF -1 NUTONE (or equiv) MODEL - QT 150 160 CFM VOLTS - 120 0.60 AMPS 2.5 SONES 6" DUCT JIl.�i MECHANICAL PLAN SCALE: 1/4" = 1'-0" i • Nil'�al� • r ti' AIR CONDITIONING KEY ® SUPPLY DIFFUSER NOTE HANG DUCT PER SMACNA STANDARDS sn SUPPLY DUCT ® THERMOSTAT MANUAL VOLUME DAMPER REMOTE SENSOR TAB COLLAR W/ REMOTE TEST STATION - ADJUSTABLE DAMPER LOW PRESSURE R-6 INSULATED FIRE DAMPER DUCT I FLEXIBLE DUCT v— FLEXIBLE DUCT: ~' I TAPE TAB COLLAR TO DUCT BOARD YPICAL Z -BAR & WIRE SEE HVAC PLAN FOR SIZE ;" DUCT WITH FOIL TAPE. SECURE INNER HANGER DETAIL CONDENSATE LINE SLEEVE TO TAB COLLAR WITH "PANDUIT' STRAP AND FOIL TAPE. TAPE ® AIRFLOW OUTER INSULATED SLEEVE TO DUCT BOARD WITH FOIL TAPE AND MASTIC. TAPE TAB COLLAR TO DUCT BOARD DUCT WITH FOIL TAPE. SECURE INNER CEILING TYPICAL HANGING STRAP SLEEVE TO TAB COLLAR WITH DIFFUSER OR AND SADDLE DETAIL "PANDUIT STRAP AND FOIL TAPE. TAPE GRILLE OUTER INSULATED SLEEVE TO DUCT BOARD WITH FOIL TAPE AND MASTIC. INSULATED SQUARE BOX FOR SQUARE NECK DIFFUSER OR DIFFUSERS ROUND NECK WITH REDUCER TYPICAL CHANNEL AND WIRE IF REQUIRED HANGER DETAIL FLEX DUCT DETAILS TYPICAL CONNECTION TO AIR DIFFUSER TYPICAL DUCT SUPPORT DETAILS NOT TO SCALE NOT TO SCALE SCALE:NTS SPLIT SYSTEM - TRANE MODEL: TTA120A3 AND AHU MODEL: TWE I20A3, A 10.0 -TON SYSTEM ARE EXISTING BUT NOT USED NEW BATH EXHAUST FAN EF -1 NUTONE (or equiv) MODEL - QT 150 160 CFM VOLTS - 120 0.60 AMPS 2.5 SONES 6" DUCT JIl.�i MECHANICAL PLAN SCALE: 1/4" = 1'-0" i • Nil'�al� • r ti' AIR CONDITIONING KEY ® SUPPLY DIFFUSER RETURN DIFFUSER sn SMOKE DUCT DETECTOR ® THERMOSTAT ® REMOTE SENSOR REMOTE TEST STATION - VOLUME DAMPER FIRE DAMPER F.D. v— RADIATION DAMPER R.D. REFRIGERANT LINE CONDENSATE LINE RCS CONTRACTOR SERVICES, INC. 1798 NW 39TH COURT OAKLAND PARK, FLORIDA 33309 BROWARD: 954-295-2182 ALL IDEAS, DESIGNS, ARRANGEMENTS, AND PLANS INDICATED OR REPRESENTED BY THIS DRAWING ARE OWNED BY, AND THE PROPERTY OF TECTONICS ASSOCIATES, INC. AND WERE CREATED, EVOLVED AND DEVELOPED FOR USE ON, AND IN CONNECTION WITH THE SPECIFIED PROJECT. NONE OF SUCH IDEAS, DESIGNS, ARRANGEMENTS OR PLANS SHALL BE USED BYOR DISCLOSED TO ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF TECTONICS ASSOCIATES, INC. WRITTEN DIMENSIONS OF THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. CONTRACTORS SHALL VERIFY, AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB AND THIS OFFICE MUST BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. SHOP DETAILS MUST BE SUBMITTED TO THIS OFFICE FOR APPROVAL BEFORE PROCEEDING WITH FABRICATION. N O L a Cl W N W co co a_Q so LL a a� my �co Qa ►W -r` 005,00 Z U'"(3 >>+� 7m aLLc W+to rcZ aim a��a+ '7 = co Z :EW �c ��� ' c w z00 :7 W w ' zZa+z =0 0 CLO O LL Z O '§-i- 0 Z W W O CL O w IL 705020 Q O LL N N 0 E �v .E -o d c 0 3 3 3 date :12-10-08 REVISED BY: ONE D+B I ■ project Number 41. 46 sheet -1 of