09-97-03171 d - In M Ln ON 0 0 N In N w 3 v CL UJ d- 00 aai � E uc CA C M X 4u M i lD Q M 00 CL 00o C:) M i N Y PANELBOARD "A" NEW BUS KVA LOAD A I BTC WIRE GND COND AMPS BUS ABC AMPS COND GND WIRE LOAD BUS KVA A I B C 3.1 RTU -1 _ 3_.1 3.1 #8 #10 3/4" 3P-40 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33--W--34 35 37 39 41 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 36 38 40 42 3P-35 3/4" #10 #8 RTU -2 3.1 3.1 3.1- 0.8 -- SODA & ICE DISPENSER #12 1 #12 1/2" 1 1 P-20 1 P-20 1/2" 1 #12 #12 1 REF. @ COUNTER 1.0 0.8 ICE MACHINE #12 #12 1/2" 1 P-20 1 P-20 1/2" #12 #12 EQUIPMENT @ COUNTER 0.8 0.8 SODA & ICE DISPENSER #12 #12 1/2" 1 P-20 1 P-20 1/2" #12 #12 P.O.S. @ COUNTER 0.8 0.8 REFRIGERATOR #12 #12 1/2" 1 P-20 1 P-20 1/2" #12 #12 CONVEYOR OVEN 1.0 1.0 POS @ PICK UP WINDOW #12 #12 1/2" 1 P-20 1 P-20 1/2" #12 #12 DOUGH ROLLER 1.0 1.2 MIXER 1.2 #10 #10 3/4" 2P-30 1 P-20 1/2" #12 #12 LIGHT LOGO @ PARAPET 1.0 1P-20 1/2" #12 #12 SLICER 1.0 0.8 COOLER COIL #12 #12 1/2" 1P-20 1P-20 1/2" #12 #12 SODA SYSTEM 0.8 1.2 ICE MACHINE @ KITCHEN 1.2 #10 #10 3/4" 2P-30 1P-20 1/2", #12 #12 MENU SIGN GFI 0.8 1 P-20 1/2" #12 #12 MENU SIGN GFI 0.8 1.0 REFRIGERATOR #12 #12 11 /2" 1 P-20 - - - - - - - - - - - - - - - - - - 1.0 SIGN OUTSIDE GFI #12 - - - - - - - - - - - - - - - - - - - - _ #12 KITCHEN EXHAUST FAN 1.5 - - - - - - - - - - - - - - - - - - - - - - - -- - -- - - - - _ - - - - - - - - - - - - - - - - - - TOTAL KVA- BUS A 14.0 BUS B 12.4 BUS C 12 CONNECTED Kva: 38.4 AMPERES: BUS A- BUS B - BUS C - TOTAL - RATED VOLTAGE: N 120/208 ❑ 120/240 ❑ 277/480 3 PHASE, 4 WIRE I BRANCH POLES ❑ 12 ❑ 18 ❑ 20 ❑ 24 ❑ 30 ❑ 36 E 42 RATED AMPS: 0 150 ❑ 225 ❑ 400 ❑ CABINET: ❑ SURFACE N FLUSH FULL NEUTRAL BUS GROUND BUS HINGED DOOR KEYED DOOR LATCH ENCLOSURE TYPE NEMA 1 BRANCH DEVICES ❑ FUSED E CIRCUIT BREAKER (BOLT -IN) NEW E MAIN LUGS ONLY MAIN AMPS ❑ BREAKER ❑ FUSED SWITCH ❑ TO BE GFI BREAKERS ALL BREAKERS MUST BE RATED TO INTERRUPT A SHORT CIRCUIT CURRENT OF 22,000 AMPS SYMMETRICAL. ACCEPTABLE MANUFACTURERS: SQUARE D, GE, ITE, WESTINGHOUSE I A PANEL -A DEMAND LOAD CALCULATIONS TOTAL RECEP. LOAD 13,000 VA RECEP. 1st 10,000 VA @ 100% 10,000 @100% 10,000 VA REST @ 50% 3,000 @50% 1,500 VA LIGHTING LOAD @ 125% 1,000@125% 1,250 VA LARGEST MOTOR @125% 0@125% 0 VA AIR CONDITIONERS & COOLERS @ 100% 18,600@100% 18,600 VA REST OF ALL OTHER LOADS @ 100% 5,800@100% 5,800 VA TOTAL LOAD 37,150 VA CURRENT PER PHASE = TOTAL LOAD (VA) / (240) = 103.12 104 AMPS 4#1/0 & 1#6 GND IN 2"C. 4#1/0 & 1#6 GND IN 2"C. t PANEL GRADE MAIN NO.1 400 AMP M.C.B. #6 GND. EXISTING O.H. SERVICE EXISTING ' " ' FP&L POLE MOUNTED, AERIAL TRANSFORMER. EXISTING METER CONTRACTOR TO VERIFY EXISTING SERVICE ON SITE E L E C TF5a)�CALI �SEG-1 D�AQ'ro-laA Ml SEE ELECTRICAL SPECIFICATIONS RISER -01 PANELBOARD "B" NEW A BUS KVA I B PANEL "A" WIRE "B' 150 AMP AMPS 150 AMP NEW AMPS NEW MAIN NO.1 400 AMP M.C.B. #6 GND. EXISTING O.H. SERVICE EXISTING ' " ' FP&L POLE MOUNTED, AERIAL TRANSFORMER. EXISTING METER CONTRACTOR TO VERIFY EXISTING SERVICE ON SITE E L E C TF5a)�CALI �SEG-1 D�AQ'ro-laA Ml SEE ELECTRICAL SPECIFICATIONS RISER -01 PANELBOARD "B" NEW A BUS KVA I B C LOAD WIRE GND COND AMPS ENCLOSURE TYPE NEMA 1 BUS ABC i AMPS COND I GND WIRE LOAD I A BUS KVA I B C 0.2 20 AMP QUADRUPLEX RECEPTACLE MOUNTED AT 16" ABOVE FINISHED FLOOR TO BOTTOM OF LIGHT @ HOOD #12 #12 1/2" 1 P-20 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 37-411---38 39 41-142 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 40 1 P-20 1/2' #12 #12 GENERAL LIGHTING 1.2 0.2 REC. PHONEBOARD #12 #12 1/2" 1P-20 1P-20 1/2' #12 #12 GENERAL LIGHTING 1.0 1.2 OUTSIDE LIGHTING #12 #12 1/2" 1P-20 1P-20 1/2' #12 #12 GENERAL LIGHTING 0.6- 0.4 REC. GFI(UTILITY) #12 #12 1 1 /2" 1P-20 1P-20 1/2' #12 #12 GENERAL LIGHTING 0.2 0.4 REC. GFI (UTILITY) #12 #12 1/2" 1 P-20 1 P-20 1/2" #12 #12 GENERAL LIGHTING 0.8 0.8 GENERAL LIGHTING #12 #12 1/2" 1 P-20 1 P-20 1/2" #12 #12 GENRAL LIGHTING 0.8 0.8 GENERAL LIGHTING #12 #12 1/2" 1 P-20 1 P-20 1/2" #12 #12 GENERAL RECEPTACLES 1.0 1.0 GENERAL LIGHTING #12 #12 1/2" 1 P-20 1 P-20 1/2" #12 1 #12 GENERAL RECEPTACLES 1.0 0.4 REC. SERVICE (GFI) #12 #12 1/2" 1 P-20 1 P-20 1/2" #12 #12 REC. SERVICE (GFI) 0.4 0.2 LIGHT @ HOOD #12 #12 1/2" 1 P-20 1 P-20 1/2" #12 #12 GENERAL RECEPTACLES 0.4 1.0 SIGN OUTSIDE GFI #12 #12 1 1 /2" 1P-20 1P-20 1/2" #12 #12 KITCHEN SUPPLY FAN 1.5 _ - - - 1 P-20 1/2" #12 #12 KITCHEN EXHAUST FAN 1.5 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - _- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - TOTAL KVA: BUS A 4.4 BUS B 5.9 BUS C 5.7 CONNECTED Kva: 16.0 AMPERES: BUS A- BUS B - BUS C - TOTAL - RATED VOLTAGE: 0 120/208 ❑ 120/240 ❑ 277/480 3 PHASE, 4 WIRE BRANCH POLES ❑ 12 ❑ 18 ❑ 20 ❑ 24 ❑ 30 ❑ 36 0 42 RATED AMPS: N 150 ❑ 225 ❑ 400 ❑ I CABINET: ❑ SURFACE 0 FLUSH FULL NEUTRAL BUS I E GROUND BUS HINGED DOOR KEYED DOOR LATCH ENCLOSURE TYPE NEMA 1 BRANCH DEVICES ❑ FUSED 0 CIRCUIT BREAKER (BOLT -IN) $3 E MAIN LUGS ONLY MAIN AMPS ❑ BREAKER ❑ FUSED SWITCH ❑ TO BE GFI BREAKERS ALL BREAKERS MUST BE RATED TO INTERRUPT A SHORT CIRCUIT CURRENT OF 22,000 AMPS SYMMETRICAL. ACCEPTABLE MANUFACTURERS: SQUARE D, GE, ITE, WESTINGHOUSE (n MAIN SERVICE DEMAND LOAD CALCULATIONS TOTAL RECEP. LOAD 17,200 VA RECEP. 1st 10,000 VA @ 100% 10,000 @100% 10,000 VA REST @ 50% 7,200 @50% 3,400 VA LIGHTING LOAD @ 125% 10,800@125% 13,500 VA LARGEST MOTOR @125% 0@125% 0 VA AIR CONDITIONERS & COOLERS @ 100% 18,600@100% 18,600 VA REST OF ALL OTHER LOADS @ 100% 8,800@100% 8,800 VA TOTAL LOAD 54,300 VA CURRENT PER PHASE = TOTAL LOAD (VA) / (240) = 150.72 151 AMPS ELECTRICAL LEGEND PANEL -B DEMAND LOAD CALCULATIONS TOTAL RECEP. LOAD 4,200 VA RECEP. 1St 10,000 VA @ 100% 4,200 @100% 4,200 VA REST @ 50% 0 @50% 0 VA LIGHTING LOAD @ 125% 9,800@125% 12,250 VA LARGEST MOTOR @125% 0@125% 0 VA AIR CONDITIONERS & COOLERS @ 100% 0@100% 0 VA REST OF ALL OTHER LOADS @ 100% 3,000@100% 3,000 VA TOTAL LOAD 19,450 VA CURRENT PER PHASE = TOTAL LOAD (VA) / (240) = 53.98 54 AMPS TYPICAL CONDUIT CONCEALED ABOVE SUSPENDED CEILING TO NEXT JUNCTION BOX OR HOMERUN. �r CEILING HANGER WIRE. REFER TOr ARCHITECTURAL SUSPENDED CEILING GRID BY OTHERS LIGHT FIXTURE JUNCTION BOX INSTALLED ABOVE SUSPENDED CEILING. - AVOID CABLE HOLES, A/C DUCT, ETC. �-EXISTING CEILING SLAB FLEXIBLE CONDUIT ALLOW SUFFICIENT SLACK SO THAT FIXTURE CAN BE SHIFTED ONE COMPLETE TILE IN ANY DIRECTION MAX LENGTH 6' NOTES: O PROVIDE #12 GREEN GROUND WIRE IN FLEXIBLE CONDUIT WITH BRANCH CIRCUIT WIRING AND BOND TO OUTLET BOX AND FIXTURE HOUSING. O SECURELY FASTEN FIXTURE TO CEILING FRAMING MEMBERS WITH FOUR (4) T -BAR CLIPS PER FIXTURE. SUPPORT FROM SUSPENDED CEILING ONLY AS APPROVED BY ARCHITECT. LIGHTING FIXTURE MOUNTING DETAIL NOT TO SCALE - - - ! ■� N E p � s W � m ■� J CO o - � 3 ELECTRICAL SPECIFICATIONS - = a LL:. C � " U A. GENERAL PROVISIONS w 1. THE WORK SHALL CONSIST OF FURNISHING LABOR, EQUIPMENT, V ca AND MATERIALS TO PROVIDE THE COMPLETE INTEGRATED AND Z J I• U PROPER FUNCTIONING SYSTEMS AS SHOWN ON THE DRAWINGS. 2. ALL WORK SHALL BE DONE IN CONFORMANCE WITH THE LATEST ' > > LL JOR EDITION OF THE NATIONAL ELECTRICAL CODE, AND ALL CODES AND m Q c T ORDINANCES OF THE AUTHORITY HAVING JURISDICTION. V W + g an 5 1 3. ALL EQUIPMENT AND MATERIALS PROVIDED SHALL BE NEW AND IN FW- cc Z Q (1-0 m CONFORMANCE WITH APPLICABLE PROVISIONS OF NEMA, ANSI, U.L., Q 2 v+ ETC. AND SHALL BEAR AN UNDERWRITERS LABEL WHERE APPLICABLE U -� _ CO 4. THE ELECTRICAL CONTRACTOR SHALL COORDINATE HIS WORK oC N C0 (Z9 WITH THAT OF OTHER TRADES SO AS TO AVOID INTERFERENCE. a W cc p 0 to 5. THE DRAWINGS ARE DIAGRAMMATIC AND INDICATE GENERAL ZC 00 Z ao UJ p '3 LAYOUT OF ELECTRICAL SYSTEMS. THE CONTRACTOR SHALL a W m � W FIELD VERIFY EXISTING CONDITIONS PRIOR TO BIDDING THE PROJECT. cO = z � a O 6. THE CONTRACTOR SHALL PAY FOR ALL PERMITS AND INSPECTIONS REQUIRED BY STATE AND LOCAL LAWS AND ORDINANCES. 7. UPON COMPLETION OF THE WORK, FURNISH TO THE OWNER g CERTIFICATES OF FINAL INSPECTIONS AND APPROVALS FROM AUTHORITIES HAVING JURISDICTION. 705020 8. ALL WORK SHALL BE GUARANTEED FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF FINAL ACCEPTANCE BY THE OWNER. 9. ALL WORK SHALL BE PERFORMED BY A LICENSED ELECTRICAL CONTRACTOR. 10. ANY DEFECTS FOUND DURING OR AT THE COMPLETION OF WORK SHALL BE CORRECTED BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER. 11. THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS OR CUT SHEETS U Lf) OF DEVICES, PANELBOARDS, DISCONNECT SWITCHES, STARTERS, LIGHTING W FIXTURES AND OTHER ELECTRICAL EQUIPMENT FOR APPROVAL TO THE I-- 1 ARCHITECT/ENGINEER.O 12. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CUTTING AND U Q PATCHING OF HIS WORK. 13. THE TERM'PROVIDE' USED IN THE CONSTRUCTION DOCUMENTS AND < r - SPECIFICATIONS DENOTES THE CONTRACTOR SHALL FURNISH AND Q (� INSTALL. I- w LLI 14. THE CONTRACTOR SHALL COORDINATE WITH FPL ALL REQUIREMENTS FOR CONDUIT ENTRY AND CABLE TERMINATIONS IN THE UTILITYLV O W TRANSFORMER. ANY CONFLICTS SHALL BE BROUGHT TO THE ATTENTION -) ---i Q OF THE ARCHITECT/ENGINEER PRIOR TO COMMENCEMENT OF WORK. L 15. THE CONTRACTOR SHALL COORDINATE WITH THE TELEPHONE UTILITY cr- LL FOR PROVIDING THE REQUIRED CONDUIT SIZE AND NUMBER TO THE TENANT SPACE. THE CONTACTOR SHALL PROVIDE ALL CONDUITS WITH - PULL CORDS AND SHALL INSTALL FROM THE LOCAL TELEPHONE BOARD TO THE MAIN POINT OF SERVICE. 16. WIRING CIRCUITS TO OPEN OFFICE WORKSTATIONS SHALL HAVE A DEDICATED NEUTRAL FOR EACH CIRCUIT. SHARED NEUTRALS ARE Q NOT ALLOWED. COMPUTER CIRCUITS SHALL HAVE A DEDICATED NEUTRAL. A GREEN GROUND WIRE SHALL BE PROVIDE FOR EACH CIRCUIT. THE GROUND CAN BE SHARED FOR MULTIPLE CIRCUITS (EXCEPT FOR IG CIRCUITS) O B. RACEWAYS LL 1. ALL WIRING SHALL BE INSTALLED IN CONDUIT. CONDUIT SHALL BE r E.M.T. (ELECTRICAL METALLIC TUBING) INSIDE THE BUILDING AND RIGID STEEL ON THE EXTERIOR EXPOSED FROM V ABOVE GRADE. CONDUIT BELOW GRADE SHALL BE RIGID STEEL CONDUIT WITH TWO COATS OF BITUMINOUS COATING, OR BE SCHEDULE 40 PVC. 2. MINIMUM CONDUIT SIZE SHALL BE 1/2" TRADE SIZE. 3. USE FLEXIBLE CONDUIT FOR SHORT FINAL CONNECTIONS TO VIBRATING EQUIPMENT SUCH AS MOTORS AND TRANSFORMERS. LIQUID -TIGHT FLEXIBLE CONDUIT SHALL BE USED IN DAMP AND WET LOCATIONS. 4. EXPOSED CONDUITS SHALL BE RUN PARALLEL TO BUILDING LINES. _ 5. DO NOT INSTALL CONDUITS LARGER THAN 1/3 THE SLAB THICKNESS IN CONCRETE SLABS. 6. PROVIDE APPROVED FIRE STOPPING MATERIALS AT ALL PENETRATIONS THROUGH FIRE RATED FLOORS AND WALLS TO PREVENT THE PASSAGE OF SMOKE, FIRE, TOXIC GAS OR WATER THROUGH THE PENETRATION EITHER BEFORE, DURING, OR AFTER A FIRE, AS REQUIRED BY ARTICLE 300-21 OF THE N.E.C. Q - 7. PROVIDE CABLE SUPPORTS IN ACCORDANCE WITH ARTICLE 300 OF THE N.E.0 = - 8. PROVIDE EXPANSION FITTINGS IN CONDUIT RUNS CROSSING STRUCTURAL EXPANSION JOINTS. C. CONDUCTORS _ 1. ALL WIRING SHALL BE COPPER. H� 2. METAL CLAD WIRING INSIDE WALLS IS PERMITTED. O 3. MINIMUM CONDUCTOR SIZE SHALL BE #12 AWG. CONTROL WIRING MAY BE #14 AWG. Z 0 V� 1 D. DEVICES Q 1. ALL ELECTRICAL AND COMMUNICATIONS OUTLETS TO BEAT 16" AFF Q A.F.F UNLESS OTHERWISE NOTED, ALL LIGHT SWITCHES SHALL BE Z @42" A.F.F. wQ E. PANELBOARDS OW 1. PROVIDE LIGHTING AND RECEPTACLE PANELS AS INDICATED ON �W N 0 THE PLANS AND AS SPECIFIED HEREIN. ALL PANELS SHALL BEw DEAD FRONT, CIRCUIT BREAKER TYPE, AND SHALL BEAR THE F� O U.L. LABEL AS WELL AS MEET ALL APPLICABLE NEMA REQUIREMENTS a (1 00 2. UNLESS OTHERWISE NOTED, TOP OF PANELS SHALL BE MOUNTED co 6'-0" A.F.F. 3. ALL PANELS SHALL HAVE TYPEWRITTEN CIRCUIT DIRECTORIES MOUNTED INSIDE OF DOOR. 4. PANELS SHALL BE SUITABLE FOR THE SERVICE RATING AND THE A.I.C. RATING INDICATED ON THE PANEL SCHEDULES. 5. ALL BREAKERS SHALL BE FULL SPACE, INDIVIDUAL FRAME TYPE. NO "PIGGY -BACK" OR TANDEM BREAKERS WILL BE PERMITTED. 6. CONTRACTOR SHALL PROVIDE ON ALL FLUSH (RECESSED) MOUNTED PANELS TWO (2), SPARE 2" CONDUITS STUBBED INTO THE CEILING SPACE 7. ALL CURRENT CARRYING BUSBARS SHALL BE COPPER. F. SAFETY SWITCHES 1. SAFETY SWITCHES SHALL BE HEAVY DUTY TYPE, FUSIBLE OR NON -FUSIBLE WITH POLES, AMPERE AND SERVICE RATINGS AS INDICATED ON THE PLANS. LUGS SHALL BE U.L. LISTED FOR CU. -AL. 2. ENCLOSURES FOR SAFETY SWITCHES SHALL BE NEMA 1, EXCEPT FOR SWITCHES MARKED "WP" (WEATHERPROOF) SHALL BE NEMA 3R. G. FUSES date 12-10-08 1. ALL FUSES SHALL HAVE A 200,000 AMP RMS SYMMETRICAL REVISED BY: ONE D+B INTERRUPTING RATING UNLESS OTHERWISE NOTED. 2. FUSES RATED 0 TO 600 AMPS SHALL BE AS FOLLOWS: a) CIRCUIT BREAKER PANEL PROTECTION - U.L. CLASS RK -1, DUAL ELEMENT (BUSSMANN "LOW -PEAK" OR EQUAL). b) MOTOR CIRCUIT PROTECTION - U.L. CLASS RK -5, DUAL ELEMENT (BUSSMANN "FUSETRON" OR EQUAL). 3. FUSES RATED 601 AMPS OR LARGER SHALL BE U.L. CLASS L. TIME DELAY (BUSSMANN "HI -CAP" OR EQUAL). C ro ALL IDEAS, DESIGNS, ARRANGEMENTS, AND PLANS INDICATED OR REPRESENTED BY THIS DRAWING ARE OWNED BY, AND THE PROPERTY OF TECTONICS ASSOCIATES, INC. AND WERE CREATED, EVOLVED AND DEVELOPED FOR USE ON, AND IN CONNECTION WITH THE SPECIFIED PROJECT. NONE OF SUCH IDEAS, DESIGNS, ARRANGEMENTS OR PLANS SHALL BE USED BYOR DISCLOSED TO ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF TECTONICS ASSOCIATES, INC. WRITTEN DIMENSIONS OF THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. CONTRACTORS SHALL VERIFY, AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB AND THIS OFFICE MUST BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. SHOP DETAILS MUST BE SUBMITTED TO THIS OFFICE FOR APPROVAL BEFORE PROCEEDING WITH FABRICATION. project number 08146 sheet E-2 of 2X4 FLUORESCENT LAY -IN LIGHT FIXTURE, 120V, 3-T8 LAMPS, ELECTRONIC BALLAST. 2X2 FLUORESCENT LAY -IN LIGHT FIXTURE, 120V, 3-T8 LAMPS, ELECTRONIC BALLAST. 2) LED EXIT SIGN/LIGHT. WITH 90 MIN BATT. BACKUP EMERGENCY LIGHT, WITH 90 MIN BATT BACKUP, UNIVERSAL MOUNTING. 1 POLE, 20 AMP, SWITCH WALL $3 3 -WAY, 20 AMP, SWITCH WALL $4 4 -WAY, 20 AMP, SWITCH WALL 20 AMP DUPLEX RECEPTACLE (n 20 AMP DUPLEX RECEPTACLE WITH GROUND FAULT CIRCUIT INTERRUPTER 20 AMP QUADRUPLEX RECEPTACLE MOUNTED AT 16" ABOVE FINISHED FLOOR TO BOTTOM OF RECEPTACLE UNLESS NOTED OTHERWISE. TELEPHONE/DATA OUTLET WITH 3/4" CONDUIT STUBBED 6" ABOVE CEILING W/ PULL STRING. Q JUNCTION BOX EF EXHAUST FAN. SEE MECHANICAL DRAWINGS FOR SPECIFICATIONS. ELECTRICAL PANELBOARD WP DENOTES WEATHERPROOF ®CM CEILING MOUNTED PANEL -B DEMAND LOAD CALCULATIONS TOTAL RECEP. LOAD 4,200 VA RECEP. 1St 10,000 VA @ 100% 4,200 @100% 4,200 VA REST @ 50% 0 @50% 0 VA LIGHTING LOAD @ 125% 9,800@125% 12,250 VA LARGEST MOTOR @125% 0@125% 0 VA AIR CONDITIONERS & COOLERS @ 100% 0@100% 0 VA REST OF ALL OTHER LOADS @ 100% 3,000@100% 3,000 VA TOTAL LOAD 19,450 VA CURRENT PER PHASE = TOTAL LOAD (VA) / (240) = 53.98 54 AMPS TYPICAL CONDUIT CONCEALED ABOVE SUSPENDED CEILING TO NEXT JUNCTION BOX OR HOMERUN. �r CEILING HANGER WIRE. REFER TOr ARCHITECTURAL SUSPENDED CEILING GRID BY OTHERS LIGHT FIXTURE JUNCTION BOX INSTALLED ABOVE SUSPENDED CEILING. - AVOID CABLE HOLES, A/C DUCT, ETC. �-EXISTING CEILING SLAB FLEXIBLE CONDUIT ALLOW SUFFICIENT SLACK SO THAT FIXTURE CAN BE SHIFTED ONE COMPLETE TILE IN ANY DIRECTION MAX LENGTH 6' NOTES: O PROVIDE #12 GREEN GROUND WIRE IN FLEXIBLE CONDUIT WITH BRANCH CIRCUIT WIRING AND BOND TO OUTLET BOX AND FIXTURE HOUSING. O SECURELY FASTEN FIXTURE TO CEILING FRAMING MEMBERS WITH FOUR (4) T -BAR CLIPS PER FIXTURE. SUPPORT FROM SUSPENDED CEILING ONLY AS APPROVED BY ARCHITECT. LIGHTING FIXTURE MOUNTING DETAIL NOT TO SCALE - - - ! ■� N E p � s W � m ■� J CO o - � 3 ELECTRICAL SPECIFICATIONS - = a LL:. C � " U A. GENERAL PROVISIONS w 1. THE WORK SHALL CONSIST OF FURNISHING LABOR, EQUIPMENT, V ca AND MATERIALS TO PROVIDE THE COMPLETE INTEGRATED AND Z J I• U PROPER FUNCTIONING SYSTEMS AS SHOWN ON THE DRAWINGS. 2. ALL WORK SHALL BE DONE IN CONFORMANCE WITH THE LATEST ' > > LL JOR EDITION OF THE NATIONAL ELECTRICAL CODE, AND ALL CODES AND m Q c T ORDINANCES OF THE AUTHORITY HAVING JURISDICTION. V W + g an 5 1 3. ALL EQUIPMENT AND MATERIALS PROVIDED SHALL BE NEW AND IN FW- cc Z Q (1-0 m CONFORMANCE WITH APPLICABLE PROVISIONS OF NEMA, ANSI, U.L., Q 2 v+ ETC. AND SHALL BEAR AN UNDERWRITERS LABEL WHERE APPLICABLE U -� _ CO 4. THE ELECTRICAL CONTRACTOR SHALL COORDINATE HIS WORK oC N C0 (Z9 WITH THAT OF OTHER TRADES SO AS TO AVOID INTERFERENCE. a W cc p 0 to 5. THE DRAWINGS ARE DIAGRAMMATIC AND INDICATE GENERAL ZC 00 Z ao UJ p '3 LAYOUT OF ELECTRICAL SYSTEMS. THE CONTRACTOR SHALL a W m � W FIELD VERIFY EXISTING CONDITIONS PRIOR TO BIDDING THE PROJECT. cO = z � a O 6. THE CONTRACTOR SHALL PAY FOR ALL PERMITS AND INSPECTIONS REQUIRED BY STATE AND LOCAL LAWS AND ORDINANCES. 7. UPON COMPLETION OF THE WORK, FURNISH TO THE OWNER g CERTIFICATES OF FINAL INSPECTIONS AND APPROVALS FROM AUTHORITIES HAVING JURISDICTION. 705020 8. ALL WORK SHALL BE GUARANTEED FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF FINAL ACCEPTANCE BY THE OWNER. 9. ALL WORK SHALL BE PERFORMED BY A LICENSED ELECTRICAL CONTRACTOR. 10. ANY DEFECTS FOUND DURING OR AT THE COMPLETION OF WORK SHALL BE CORRECTED BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER. 11. THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS OR CUT SHEETS U Lf) OF DEVICES, PANELBOARDS, DISCONNECT SWITCHES, STARTERS, LIGHTING W FIXTURES AND OTHER ELECTRICAL EQUIPMENT FOR APPROVAL TO THE I-- 1 ARCHITECT/ENGINEER.O 12. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CUTTING AND U Q PATCHING OF HIS WORK. 13. THE TERM'PROVIDE' USED IN THE CONSTRUCTION DOCUMENTS AND < r - SPECIFICATIONS DENOTES THE CONTRACTOR SHALL FURNISH AND Q (� INSTALL. I- w LLI 14. THE CONTRACTOR SHALL COORDINATE WITH FPL ALL REQUIREMENTS FOR CONDUIT ENTRY AND CABLE TERMINATIONS IN THE UTILITYLV O W TRANSFORMER. ANY CONFLICTS SHALL BE BROUGHT TO THE ATTENTION -) ---i Q OF THE ARCHITECT/ENGINEER PRIOR TO COMMENCEMENT OF WORK. L 15. THE CONTRACTOR SHALL COORDINATE WITH THE TELEPHONE UTILITY cr- LL FOR PROVIDING THE REQUIRED CONDUIT SIZE AND NUMBER TO THE TENANT SPACE. THE CONTACTOR SHALL PROVIDE ALL CONDUITS WITH - PULL CORDS AND SHALL INSTALL FROM THE LOCAL TELEPHONE BOARD TO THE MAIN POINT OF SERVICE. 16. WIRING CIRCUITS TO OPEN OFFICE WORKSTATIONS SHALL HAVE A DEDICATED NEUTRAL FOR EACH CIRCUIT. SHARED NEUTRALS ARE Q NOT ALLOWED. COMPUTER CIRCUITS SHALL HAVE A DEDICATED NEUTRAL. A GREEN GROUND WIRE SHALL BE PROVIDE FOR EACH CIRCUIT. THE GROUND CAN BE SHARED FOR MULTIPLE CIRCUITS (EXCEPT FOR IG CIRCUITS) O B. RACEWAYS LL 1. ALL WIRING SHALL BE INSTALLED IN CONDUIT. CONDUIT SHALL BE r E.M.T. (ELECTRICAL METALLIC TUBING) INSIDE THE BUILDING AND RIGID STEEL ON THE EXTERIOR EXPOSED FROM V ABOVE GRADE. CONDUIT BELOW GRADE SHALL BE RIGID STEEL CONDUIT WITH TWO COATS OF BITUMINOUS COATING, OR BE SCHEDULE 40 PVC. 2. MINIMUM CONDUIT SIZE SHALL BE 1/2" TRADE SIZE. 3. USE FLEXIBLE CONDUIT FOR SHORT FINAL CONNECTIONS TO VIBRATING EQUIPMENT SUCH AS MOTORS AND TRANSFORMERS. LIQUID -TIGHT FLEXIBLE CONDUIT SHALL BE USED IN DAMP AND WET LOCATIONS. 4. EXPOSED CONDUITS SHALL BE RUN PARALLEL TO BUILDING LINES. _ 5. DO NOT INSTALL CONDUITS LARGER THAN 1/3 THE SLAB THICKNESS IN CONCRETE SLABS. 6. PROVIDE APPROVED FIRE STOPPING MATERIALS AT ALL PENETRATIONS THROUGH FIRE RATED FLOORS AND WALLS TO PREVENT THE PASSAGE OF SMOKE, FIRE, TOXIC GAS OR WATER THROUGH THE PENETRATION EITHER BEFORE, DURING, OR AFTER A FIRE, AS REQUIRED BY ARTICLE 300-21 OF THE N.E.C. Q - 7. PROVIDE CABLE SUPPORTS IN ACCORDANCE WITH ARTICLE 300 OF THE N.E.0 = - 8. PROVIDE EXPANSION FITTINGS IN CONDUIT RUNS CROSSING STRUCTURAL EXPANSION JOINTS. C. CONDUCTORS _ 1. ALL WIRING SHALL BE COPPER. H� 2. METAL CLAD WIRING INSIDE WALLS IS PERMITTED. O 3. MINIMUM CONDUCTOR SIZE SHALL BE #12 AWG. CONTROL WIRING MAY BE #14 AWG. Z 0 V� 1 D. DEVICES Q 1. ALL ELECTRICAL AND COMMUNICATIONS OUTLETS TO BEAT 16" AFF Q A.F.F UNLESS OTHERWISE NOTED, ALL LIGHT SWITCHES SHALL BE Z @42" A.F.F. wQ E. PANELBOARDS OW 1. PROVIDE LIGHTING AND RECEPTACLE PANELS AS INDICATED ON �W N 0 THE PLANS AND AS SPECIFIED HEREIN. ALL PANELS SHALL BEw DEAD FRONT, CIRCUIT BREAKER TYPE, AND SHALL BEAR THE F� O U.L. LABEL AS WELL AS MEET ALL APPLICABLE NEMA REQUIREMENTS a (1 00 2. UNLESS OTHERWISE NOTED, TOP OF PANELS SHALL BE MOUNTED co 6'-0" A.F.F. 3. ALL PANELS SHALL HAVE TYPEWRITTEN CIRCUIT DIRECTORIES MOUNTED INSIDE OF DOOR. 4. PANELS SHALL BE SUITABLE FOR THE SERVICE RATING AND THE A.I.C. RATING INDICATED ON THE PANEL SCHEDULES. 5. ALL BREAKERS SHALL BE FULL SPACE, INDIVIDUAL FRAME TYPE. NO "PIGGY -BACK" OR TANDEM BREAKERS WILL BE PERMITTED. 6. CONTRACTOR SHALL PROVIDE ON ALL FLUSH (RECESSED) MOUNTED PANELS TWO (2), SPARE 2" CONDUITS STUBBED INTO THE CEILING SPACE 7. ALL CURRENT CARRYING BUSBARS SHALL BE COPPER. F. SAFETY SWITCHES 1. SAFETY SWITCHES SHALL BE HEAVY DUTY TYPE, FUSIBLE OR NON -FUSIBLE WITH POLES, AMPERE AND SERVICE RATINGS AS INDICATED ON THE PLANS. LUGS SHALL BE U.L. LISTED FOR CU. -AL. 2. ENCLOSURES FOR SAFETY SWITCHES SHALL BE NEMA 1, EXCEPT FOR SWITCHES MARKED "WP" (WEATHERPROOF) SHALL BE NEMA 3R. G. FUSES date 12-10-08 1. ALL FUSES SHALL HAVE A 200,000 AMP RMS SYMMETRICAL REVISED BY: ONE D+B INTERRUPTING RATING UNLESS OTHERWISE NOTED. 2. FUSES RATED 0 TO 600 AMPS SHALL BE AS FOLLOWS: a) CIRCUIT BREAKER PANEL PROTECTION - U.L. CLASS RK -1, DUAL ELEMENT (BUSSMANN "LOW -PEAK" OR EQUAL). b) MOTOR CIRCUIT PROTECTION - U.L. CLASS RK -5, DUAL ELEMENT (BUSSMANN "FUSETRON" OR EQUAL). 3. FUSES RATED 601 AMPS OR LARGER SHALL BE U.L. CLASS L. TIME DELAY (BUSSMANN "HI -CAP" OR EQUAL). C ro ALL IDEAS, DESIGNS, ARRANGEMENTS, AND PLANS INDICATED OR REPRESENTED BY THIS DRAWING ARE OWNED BY, AND THE PROPERTY OF TECTONICS ASSOCIATES, INC. AND WERE CREATED, EVOLVED AND DEVELOPED FOR USE ON, AND IN CONNECTION WITH THE SPECIFIED PROJECT. NONE OF SUCH IDEAS, DESIGNS, ARRANGEMENTS OR PLANS SHALL BE USED BYOR DISCLOSED TO ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF TECTONICS ASSOCIATES, INC. WRITTEN DIMENSIONS OF THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. CONTRACTORS SHALL VERIFY, AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB AND THIS OFFICE MUST BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. SHOP DETAILS MUST BE SUBMITTED TO THIS OFFICE FOR APPROVAL BEFORE PROCEEDING WITH FABRICATION. project number 08146 sheet E-2 of