09-97-025c
6 PIZZA BAR ELEVATION
'7'5) SCALE: 3/8"=1'-0"
BLACK PORCELAIN TILE
LAVAGNA NERO BY ROCA
12X48 OVER DUROCK
OPEN SPACE FOR STORAGE
PRODUCT DISPLAY AND WINES
NOTE: LAMINATE ALL EXPOSED FACES
OF CABINETRY -SPECIFICALLY
UNDERSIDE OF COUNTER EDGE AND
ALL SHELVING.
DRYWALL SOFFIT WITH
LED LIGHT REFLECTORS
W
D'
IV
zI�
Q�
FRAMELESS TEMPERED
GLASS DISPLAY
BY OTHERS ---'-`-----
I
" I I
. I
5
A-5
PIZZA BAR DETAIL
TOP 6" MTL. STUD
SECURED TO BOTTOM OF
EXISTING TRUSSES WITH 0.177"
POWER DRIVEN FASTENERS
x 3�4" LONG AT 48" O.0
R-19 FG. INSULATION
�o
SCALE: 3/4"=1'-0"
2'X4' ACCOUSTICAL CEILING
25 GA 6" MTL
STUD @ 24" O.C.
Y2" GYP. BD ON
EA. SIDE OF 25 GA
6" MTL .STUDS .
6" METAL BASE SECURED
TO FLOOR SLAB W/0.145"
POWER DRIVEN
FASTENERS @24" O.C.
EXISTING CONCRETE SLAB
('3'TYP. 6" PARTITION
A-5 SCALE: 1/2"=V-011
STAINLESS STEEL TOP
SEE FOOD SERVICE DWGS.
PROVIDE 1 ADJUSTABLE
SHELF AT LOWER
CABINET
TOP 3%- MTL. STUD
SECURED TO BOTTOM OF
EXISTING TRUSSES WITH 0.177"
POWER DRIVEN FASTENERS
x3y4"LONG AT 48' O.0
R-19 FG. INSULATION
2'X4' ACCOUSTICAL CEILING
25 GA 3%- MTL
STUD @ 24" O.C.
Y2" GYP. BD ON
EA. SIDE OF 25 GA
35/8" MTL .STUDS .
358" METAL BASE SECURED
TO FLOOR SLAB W/0.145"
POWER DRIVEN
FASTENERS @24" O.C.
NOTE: ILLUSTRATIONS ARE INTENDED TO INDICATE
MOUNTING HEIGHTS AND REQUIRED CLEARANCES ONLY.
ALL HOT WATER AND DRAIN PIPES
SHALL BE INSULATED OR OTHERWISE
CONFIGURED TO PROTECT AGAINST
CONTACT. THERE SHALL BE NO SHARP
EDGES UNDER LAVATORIES.
MOUNTING NOTES:
MOUNT ALL RESTROOM EQUIPMENT AS RECOMMENED
z BY THE MANUFACTURER FOR BARRIER FREE DESIGN
z AND TO COMPLY WITH THE FLORIDA ACCESSIBILITY
in b CODE FOR BUILDING CONSTRUCTION.
N N ALL ACCESSORIES ARE TO BE MOUNTED WITH THEIR DISPENSING
MECHANISMS, START BUTTONS, COIN SLOTS, OR DISPENSER
8" MAX 8' MIN. OPENINGS LOCATED 38" TO 54" A.F.F.; AND TO ENSURE FORWARD
REACH ALSO, THEY MUST BE LOCATED NO MORE THAN 48" A.F.F.
1
N. WHERE ELEMENTS ARE OVER OBSTRUCTIONS, SUCH AS COUNTERS,
THEY MUST BE LOCATED NO MORE THAN 44' A.F.F.
2X6 PT. WD.
JOISTS @ 16" O.C.
USP USP TAPL16 TRUSS
ANCHORS w/ (11)10d NAILS
TO TRUSS AND (6)10d x 1-1/2"
NAILS TO SEAT. STRAP
CAPACITY: 1350 LBS.
DADE COUNTY NOA # 02-0102.03
8X12 CONC TIE BEAM
W/(4)#5 CONT. &
#3 STIRRUPS @ 12" O.C.
TYP. WALL SECTION
EXISTING CONCRETE SLAB41 —1
C ^
2 TYP. 4" PARTITION
-5 SCALE: 1/2"=V-011
54" MIN.
171, 42" MIN. 8" MAX.
36" MA' TOILET P
Z.
SCALE: 1/2"=V-011
STUCCO BY OTHERS
BUILDING PAPER BY OTHERS
FASTENER BY OTHERS
FRY REGLET "ST"
STUCCO REGLET
FRY REGLET
"SPRINGLOK" FLASHING
SUBSTRATE
BY OTHERS
B.U.R. BY OTHERS
2X6 PT. WD.
JOISTS @ 16" O.C.
(2) 2X8 PT. WD. LEDGER
W/ %-0 X 8" LG. EXPANSION
BOLTS @ 12" O.C. STAGGERED
8x8"x16" CONC. MASONRY
UNIT W/ 9 GAUGE LADDER
TYPE HORIZONTAL REINFORC.
EVERY OTHER COURSE
PICK UP/DRIVE THRU
WINDOW TO BE RELOCATED
1 #5 IN 3000 PSI GROUT
FILLED CELL @ 36" o.c.
#5 STARTER BARS ALL
SPLICES SHALL BE A MIN. 48
BAR DIAMETERS
EXISTING CMU WALL
NEW CONC. SLAB
EXISTING CONC. SLAB
1
-5
%4"
5/8" GYP. BD.
3/4" FURRING @ 24" O.C.
1 Trv-
R-5 INSULATION
8" CONC. BLOCK WALL
EXIST. STUCCO AND PAINT FINISH
TYPICAL EXTERIOR CONC. BLOCK WALL
3-5/8" 25 GAUGE MTL. STUDS
AT 24" O.C.
<I> 2 1
5/8" G.W.B. ON EACH SIDE.
TYPICAL NEW INTERIOR
WALL LEGEND
N.T.S.
MEANS OF EGRESS
THE MAXIMUM TRAVEL DISTANCE AS PER N.F.P.A. 101, TABLE A.7.6
MERCANTILE (SPRINKLERED) IS 250 FT.
1x4 WOOD
BUCK
CAULK —
SEALANT
HOT MOPPED TO #30 ANCHOR vv
SHEET TIN-TAGGEDTO %' PLYWOOD
(APA 33 6)SHEATHING NAILED TO
SUPPORTS W/10d CORROSIVE NAILS
@ 6" O.C. AT PANELS EDGES & FIELD.
2X6 PT. WD.
JOISTS @ 16" O.C.
USP USP TAPL16 TRUSS
ANCHORS w/ (11)1 Od NAILS
TO TRUSS AND (6)10d x 1-1/2"
NAILS TO SEAT. STRAP
CAPACITY: 1350 LBS.
DADE COUNTY NOA # 02-0102.03
8X12 CONC TIE BEAM
W/(4)#5 CONT. &
#3 STIRRUPS @ 12" O.C.
8178-1 B PRE -FAB LINTEL
8x8 CONC. CAP W/
(2)#5
%2' EXPANSION JOINT
TYP. WALL SECTION
SCALE: 1/2"=V-011
BATHROOM ACCESSORIES SCHEDULE
MARK
MANLIF.
MODEL #
DESCRIPTION
SIZE
TYP. LOCf{
BLACK PORCELAIN TILE
BOBRICK
B4262 CONTURA SERIES
PAPER TOWEL DISPENSER
FOR OUTLE -
LAVAGNA NERO BY ROCA
2O
BOBRICK
B-165 2430
: MOUNT HO Z
12X48 OVER DUROCK
1 PER SINK
O
BOBRICK
B-27460
MULTI -ROLL TOILET TISSUE DISPENSER
61/16" w x 11" h x 6"d
1 PER TOILET
4O
BOBRICK
CM
SANITARY NAPKIN DISPOSAL
71/2 w x 10"h x 4'd
1 PER WOMENS TOILET
5O
SPECIALTY LED LIGHTING
B-6806 SERIES
1-1/2" DIA GRAB BAR
36' STRAIGHT
1 PER TOILET
BY COLOR KINETICS
BOBRICK
B-6806 SERIES
1-112" DIA GRAB BAR
42' STRAIGHT
1 PER TOILET
N,
cr)
a
c
PROVIDE POWER(TYP)
2
----
J
o
:jj
3
5
A-5
PIZZA BAR DETAIL
TOP 6" MTL. STUD
SECURED TO BOTTOM OF
EXISTING TRUSSES WITH 0.177"
POWER DRIVEN FASTENERS
x 3�4" LONG AT 48" O.0
R-19 FG. INSULATION
�o
SCALE: 3/4"=1'-0"
2'X4' ACCOUSTICAL CEILING
25 GA 6" MTL
STUD @ 24" O.C.
Y2" GYP. BD ON
EA. SIDE OF 25 GA
6" MTL .STUDS .
6" METAL BASE SECURED
TO FLOOR SLAB W/0.145"
POWER DRIVEN
FASTENERS @24" O.C.
EXISTING CONCRETE SLAB
('3'TYP. 6" PARTITION
A-5 SCALE: 1/2"=V-011
STAINLESS STEEL TOP
SEE FOOD SERVICE DWGS.
PROVIDE 1 ADJUSTABLE
SHELF AT LOWER
CABINET
TOP 3%- MTL. STUD
SECURED TO BOTTOM OF
EXISTING TRUSSES WITH 0.177"
POWER DRIVEN FASTENERS
x3y4"LONG AT 48' O.0
R-19 FG. INSULATION
2'X4' ACCOUSTICAL CEILING
25 GA 3%- MTL
STUD @ 24" O.C.
Y2" GYP. BD ON
EA. SIDE OF 25 GA
35/8" MTL .STUDS .
358" METAL BASE SECURED
TO FLOOR SLAB W/0.145"
POWER DRIVEN
FASTENERS @24" O.C.
NOTE: ILLUSTRATIONS ARE INTENDED TO INDICATE
MOUNTING HEIGHTS AND REQUIRED CLEARANCES ONLY.
ALL HOT WATER AND DRAIN PIPES
SHALL BE INSULATED OR OTHERWISE
CONFIGURED TO PROTECT AGAINST
CONTACT. THERE SHALL BE NO SHARP
EDGES UNDER LAVATORIES.
MOUNTING NOTES:
MOUNT ALL RESTROOM EQUIPMENT AS RECOMMENED
z BY THE MANUFACTURER FOR BARRIER FREE DESIGN
z AND TO COMPLY WITH THE FLORIDA ACCESSIBILITY
in b CODE FOR BUILDING CONSTRUCTION.
N N ALL ACCESSORIES ARE TO BE MOUNTED WITH THEIR DISPENSING
MECHANISMS, START BUTTONS, COIN SLOTS, OR DISPENSER
8" MAX 8' MIN. OPENINGS LOCATED 38" TO 54" A.F.F.; AND TO ENSURE FORWARD
REACH ALSO, THEY MUST BE LOCATED NO MORE THAN 48" A.F.F.
1
N. WHERE ELEMENTS ARE OVER OBSTRUCTIONS, SUCH AS COUNTERS,
THEY MUST BE LOCATED NO MORE THAN 44' A.F.F.
2X6 PT. WD.
JOISTS @ 16" O.C.
USP USP TAPL16 TRUSS
ANCHORS w/ (11)10d NAILS
TO TRUSS AND (6)10d x 1-1/2"
NAILS TO SEAT. STRAP
CAPACITY: 1350 LBS.
DADE COUNTY NOA # 02-0102.03
8X12 CONC TIE BEAM
W/(4)#5 CONT. &
#3 STIRRUPS @ 12" O.C.
TYP. WALL SECTION
EXISTING CONCRETE SLAB41 —1
C ^
2 TYP. 4" PARTITION
-5 SCALE: 1/2"=V-011
54" MIN.
171, 42" MIN. 8" MAX.
36" MA' TOILET P
Z.
SCALE: 1/2"=V-011
STUCCO BY OTHERS
BUILDING PAPER BY OTHERS
FASTENER BY OTHERS
FRY REGLET "ST"
STUCCO REGLET
FRY REGLET
"SPRINGLOK" FLASHING
SUBSTRATE
BY OTHERS
B.U.R. BY OTHERS
2X6 PT. WD.
JOISTS @ 16" O.C.
(2) 2X8 PT. WD. LEDGER
W/ %-0 X 8" LG. EXPANSION
BOLTS @ 12" O.C. STAGGERED
8x8"x16" CONC. MASONRY
UNIT W/ 9 GAUGE LADDER
TYPE HORIZONTAL REINFORC.
EVERY OTHER COURSE
PICK UP/DRIVE THRU
WINDOW TO BE RELOCATED
1 #5 IN 3000 PSI GROUT
FILLED CELL @ 36" o.c.
#5 STARTER BARS ALL
SPLICES SHALL BE A MIN. 48
BAR DIAMETERS
EXISTING CMU WALL
NEW CONC. SLAB
EXISTING CONC. SLAB
1
-5
%4"
5/8" GYP. BD.
3/4" FURRING @ 24" O.C.
1 Trv-
R-5 INSULATION
8" CONC. BLOCK WALL
EXIST. STUCCO AND PAINT FINISH
TYPICAL EXTERIOR CONC. BLOCK WALL
3-5/8" 25 GAUGE MTL. STUDS
AT 24" O.C.
<I> 2 1
5/8" G.W.B. ON EACH SIDE.
TYPICAL NEW INTERIOR
WALL LEGEND
N.T.S.
MEANS OF EGRESS
THE MAXIMUM TRAVEL DISTANCE AS PER N.F.P.A. 101, TABLE A.7.6
MERCANTILE (SPRINKLERED) IS 250 FT.
1x4 WOOD
BUCK
CAULK —
SEALANT
HOT MOPPED TO #30 ANCHOR vv
SHEET TIN-TAGGEDTO %' PLYWOOD
(APA 33 6)SHEATHING NAILED TO
SUPPORTS W/10d CORROSIVE NAILS
@ 6" O.C. AT PANELS EDGES & FIELD.
2X6 PT. WD.
JOISTS @ 16" O.C.
USP USP TAPL16 TRUSS
ANCHORS w/ (11)1 Od NAILS
TO TRUSS AND (6)10d x 1-1/2"
NAILS TO SEAT. STRAP
CAPACITY: 1350 LBS.
DADE COUNTY NOA # 02-0102.03
8X12 CONC TIE BEAM
W/(4)#5 CONT. &
#3 STIRRUPS @ 12" O.C.
8178-1 B PRE -FAB LINTEL
8x8 CONC. CAP W/
(2)#5
%2' EXPANSION JOINT
TYP. WALL SECTION
SCALE: 1/2"=V-011
BATHROOM ACCESSORIES SCHEDULE
MARK
MANLIF.
MODEL #
DESCRIPTION
SIZE
NOTES
1O
BOBRICK
B4262 CONTURA SERIES
PAPER TOWEL DISPENSER
11 "w x 13114" h x 5" d
1 PER RESTROOM
2O
BOBRICK
B-165 2430
CHANNEL FRAME MIRROR
24" x 30"
1 PER SINK
O
BOBRICK
B-27460
MULTI -ROLL TOILET TISSUE DISPENSER
61/16" w x 11" h x 6"d
1 PER TOILET
4O
BOBRICK
B-270 CONTURA SERIES
SANITARY NAPKIN DISPOSAL
71/2 w x 10"h x 4'd
1 PER WOMENS TOILET
5O
BOBRICK
B-6806 SERIES
1-1/2" DIA GRAB BAR
36' STRAIGHT
1 PER TOILET
O
BOBRICK
B-6806 SERIES
1-112" DIA GRAB BAR
42' STRAIGHT
1 PER TOILET
N,
cr)
a
c
5
2
----
J
WOMEN
RESTROOM DETAILS
° #12 PANHEAD
o
\'7
v a
. . ° ° - ° 1.250 MIN. 3/16" TAPCON —
° @ 12" O.C. 6"
AT EDGE
0.250 MIN.
3/16" TAPCON
@ 12" O.C.
6" AT EDGE
TYP HEAD ANCHORAGE
USING A 1x4 WOOD BUCK
N.T.S.
TYP. RESTROOM ELEVATION = COW
W
O �
SCALE: 1/2"=V-011 Z e +z
Q ch n. O �
! g
705020
SCALE: 1/2"=V-011
0.250 MIN. 1.250 MIN.
a •
da
3/16"X 3 1/4"
TAPCON @ 12"
O.C. 6" AT EDGE
a. n
CAULK
. � SEALANT
T \i
CAULK 1x4 WOOD
SEALANT BUCK
TYP JAMB ANCHORAGE
USING A 1x4 WOOD BUCK
DRILL 3/4" DIA. X 8"
DEEP EMBEDDED DOWEL
W/ HILTI DOWELLING EPDXY
MIX (TYP. OF 4)
EXISTING TIE BEAM.
EXISTING 8" C.M.U.
WALL.
NEW 8" C.M.U.
WALL.
NEW FILLED CELL
W/1#5 BARS VERTICALS
HEAD
1/2" GYPSUM BOARD
BOTH SIDE$
co
v
DRILL 3/4" DIA. X 8"
DEEP EMBEDDED DOWEL
W/ HILTI DOWELLING EPDXY
MIX (TYP. OF 4) 3 5/8" MTL. TUDS
@ 24" O.C.
EXISTING CONC. SLAB. JAMB
TYP BLOCK UP/REINF. DTL.
N.T.S.
INT. WO
1/2" GYPSUM BOARD
BOTH SIDES
15/8" MTL. STUDS
D_ 24" O.C.
1/2"x 2" CASING
x JAMB
/2'x 1" DOORSTOP
I.C. DOOR
;EE DOOR SCHEDULE
1/2" x 2" CASING
1 x JAMB
I/ 1/2" x 1" DOOR STOP
H.C. DOOR I
SEE DOOR SCHEDULE
2
Q
3M SCOTCHGARD
H
W
r'
SUPERPRINT - - - _ - - - _
O
Li.
H
U2
Q
W
fn
o
U)
E
OVER GYPBD.
OOg
0
CERAMIC TILE BAND AROUND _
Z
w
w
LL
ow
E
EACH MIRROR
o
°
a
N
_^_
E
~
n
o
- -
w
�
N,
cr)
a
c
5
2
----
J
o
:jj
: ---
E
o
3
,-
S
i
wj
W
F_
�
a
N
d
7
Ld -j
m
aLLo
4X4 CERAMIC TILE
+
2 Lo
a
TO 4'-0"AFF i
co m
Z
+
U)
co
I- co z
CD
Wcc
co
TYP. RESTROOM ELEVATION = COW
W
O �
SCALE: 1/2"=V-011 Z e +z
Q ch n. O �
! g
705020
SCALE: 1/2"=V-011
0.250 MIN. 1.250 MIN.
a •
da
3/16"X 3 1/4"
TAPCON @ 12"
O.C. 6" AT EDGE
a. n
CAULK
. � SEALANT
T \i
CAULK 1x4 WOOD
SEALANT BUCK
TYP JAMB ANCHORAGE
USING A 1x4 WOOD BUCK
DRILL 3/4" DIA. X 8"
DEEP EMBEDDED DOWEL
W/ HILTI DOWELLING EPDXY
MIX (TYP. OF 4)
EXISTING TIE BEAM.
EXISTING 8" C.M.U.
WALL.
NEW 8" C.M.U.
WALL.
NEW FILLED CELL
W/1#5 BARS VERTICALS
HEAD
1/2" GYPSUM BOARD
BOTH SIDE$
co
v
DRILL 3/4" DIA. X 8"
DEEP EMBEDDED DOWEL
W/ HILTI DOWELLING EPDXY
MIX (TYP. OF 4) 3 5/8" MTL. TUDS
@ 24" O.C.
EXISTING CONC. SLAB. JAMB
TYP BLOCK UP/REINF. DTL.
N.T.S.
INT. WO
1/2" GYPSUM BOARD
BOTH SIDES
15/8" MTL. STUDS
D_ 24" O.C.
1/2"x 2" CASING
x JAMB
/2'x 1" DOORSTOP
I.C. DOOR
;EE DOOR SCHEDULE
1/2" x 2" CASING
1 x JAMB
I/ 1/2" x 1" DOOR STOP
H.C. DOOR I
SEE DOOR SCHEDULE
t
MEN;
RESTROOM DETAILS'
SCALE: 1/2"=l' -Off
(� 1 "X6" WOOD BUCK
I
0.250 MIN.
a
a•
TYP SILL ANCHORAGE
USING A 1x4 WOOD BUCK
N.T.S.
FLO
.t ,a .•tea U ,
Cfj
OD DDO,ORS,-.
M.T.S.
ALL IDEAS, DESIGNS, ARRANGEMENTS, AND PLANS INDICATED OR
REPRESENTED BY THIS DRAWING ARE OWNED BY, AND THE PROPERTY OF
TECTONICS ASSOCIATES, INC. AND WERE CREATED, EVOLVED AND
DEVELOPED FOR USE ON, AND IN CONNECTION WITH THE SPECIFIED
PROJECT. NONE OF SUCH IDEAS, DESIGNS, ARRANGEMENTS OR PLANS
SHALL BE USED BYOR DISCLOSED TO ANY PERSON, FIRM OR CORPORATION
FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF
TECTONICS ASSOCIATES, INC.
WRITTEN DIMENSIONS OF THESE DRAWINGS SHALL HAVE PRECEDENCE
OVER SCALED DIMENSIONS. CONTRACTORS SHALL VERIFY, AND BE
RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB AND THIS
OFFICE MUST BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND
CONDITIONS SHOWN BY THESE DRAWINGS. SHOP DETAILS MUST BE
SUBMITTED TO THIS OFFICE FOR APPROVAL BEFORE PROCEEDING WITH
FABRICATION.
2
Q
H
W
r'
O
Li.
H
U2
Q
W
fn
o
U)
a
0
c
Lo
M
r
U
OOg
O
Z
w
w
LL
ow
0
w
N
o
°
a
N
t
MEN;
RESTROOM DETAILS'
SCALE: 1/2"=l' -Off
(� 1 "X6" WOOD BUCK
I
0.250 MIN.
a
a•
TYP SILL ANCHORAGE
USING A 1x4 WOOD BUCK
N.T.S.
FLO
.t ,a .•tea U ,
Cfj
OD DDO,ORS,-.
M.T.S.
ALL IDEAS, DESIGNS, ARRANGEMENTS, AND PLANS INDICATED OR
REPRESENTED BY THIS DRAWING ARE OWNED BY, AND THE PROPERTY OF
TECTONICS ASSOCIATES, INC. AND WERE CREATED, EVOLVED AND
DEVELOPED FOR USE ON, AND IN CONNECTION WITH THE SPECIFIED
PROJECT. NONE OF SUCH IDEAS, DESIGNS, ARRANGEMENTS OR PLANS
SHALL BE USED BYOR DISCLOSED TO ANY PERSON, FIRM OR CORPORATION
FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF
TECTONICS ASSOCIATES, INC.
WRITTEN DIMENSIONS OF THESE DRAWINGS SHALL HAVE PRECEDENCE
OVER SCALED DIMENSIONS. CONTRACTORS SHALL VERIFY, AND BE
RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB AND THIS
OFFICE MUST BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND
CONDITIONS SHOWN BY THESE DRAWINGS. SHOP DETAILS MUST BE
SUBMITTED TO THIS OFFICE FOR APPROVAL BEFORE PROCEEDING WITH
FABRICATION.
date 12-10-08
REVISED BY: ONE D+B
project number
08146
sheet
A-5
of
2
Q
H
U)
O
Li.
O
U�
Q
O
Z
w
w
<:�
ow
0
w
N
o
°
a
N
of
O
~
n
o
a
w
�
date 12-10-08
REVISED BY: ONE D+B
project number
08146
sheet
A-5
of