09-97-008r �n N O 0 .q rn O 0 N n to ROOFING DEMOLITION NOTES: 1. REMOVE EXISTING ROOF DOWN TO THE WOOD DECK. 2. WHEN ROTTED WOOD DECK EXCEEDS 100 LINEAL FEET (10 PCS OF V -JOINT) OR 96 SQ.FT. (3 PCS PLYWOOD %"). 3. RE -NAIL WOOD DECK WITH 8d(2.5") RING SHANK COIL NAILS. 4. INSTALL ONE PLY OF 75# ASTM FELT PAPER FASTENED WITH 1.25" R/S COIL NAILS & 1%" ROUND TIN CAPS. 5. INSTALL NEW 3X3 26 GA GALVANIZED EAVE DRIP, ALONG ENTIRE ROOF EDGE. 6. INSTALL GAF RUBBEROID 201.5 SQ.FT. SMOOTH SBS/HOTMOP. 7. INSTALL GLASS CAP WHITE. 8. INSTALL NEW 16" GALVANIZED VALLEY FLASHING & NEW 26 GA GALVANIZED COUNTER FLASHING WHENEVER NEEDED. 9. PRIME EAVE DRIP & FLASHING MTL'S WITH ASTM D 41 ASPHALT PRIMER. 10. INSTALL NEW LEAD FLASHING & ROOF VENTS PENETRATIONS & SEAL WITH ASPHALT POLYGLASS 500 MEMBRANE AND ALL WHEATHER FLASHING CEMENT. 11. CLEAN-UP ALL TRASH & DEBRIS AND HAUL AWAY FROM PREMISES. GENERAL DEMOLITION NOTES: 1. ALL CEILING GRID AND TILES TO BE REMOVED. 2. ALL CEILING TILES TO BE REUSED IF POSSIBLE. (RETURN TO OWNER) 3. QUARY TILE TO REMAIN COVER AND LEVEL WITH LEVELROCK ONLY RENOVATED KITCHEN AREA, SEE RENOVATED FLOOR PLAN. 4. ALL OTHER FLOOR FINISHES TO BE REMOVED. (INT. AND EXT.) 5. ALL VINYL BASE TO BE REMOVED. 6. ALL TRIM WORK, PANELING AND MOULDING TO BE REMOVED, TO BE DISCARDED. 7. REMOVE ALL LIGHTING FIXTURES, GRILLS, OUTLET AND SWITCH COVERS AND EQUIPMENT, TO BE RETURNED TO OWNER. 8. ALL FLOORDRAINS TO REMAIN. 9. REMOVE AND CAP -OFF EXISTING PLUMBING FIXTURES. 'REVIEW DEMO SCOPE WITH OWNER PRIOR TO WORK. ol, DEMOLITION ROOF PLAN SCALE: 1/4"= 1'-0" A/C COMPRESOR TO BE RELOCATED EXISTING PLANTING AREA AIC HANDLER TO BE RELOCATED A/C HANDLER TO BE RELOCATED TO BE RE -LANDSCAPED. SEE LANDSCAPE. RELOCATE WH SEE PLUMB. =\1 I I----------------------------�I II EI(ISTING AHU TO BE R IS ED AND RELOCATED JI I II I L------� AGAIIdSTREARwACC----------------------- u Il REMOVE PANEL HATCHED AREA INDICATES AND RELOCATE TO REMOVE/GRIND CONC. I 1 SEE ELEC. (THIS AREA TO BE LEVEL) LEAVE CLEARANCE FOR LJ FINISH MATERIAL, SEE RENOVATION DWGS. FLOOR DRAINS TO REMAIN CLEAN UP & PRESURE I-1 WASH REMAINING FLOOR & PREPARE TO RECEIVE SELF LEVELING CONCRETE I I EXISTING COLUMN TOPPING BY QUICKCRETE I I TO BE REMOVED OR OTHER APPROVED. REMOVE EXISTING I I TILE II r /- FLOOR DRAINS TO REMAIN I I I I EXIST. CMUIBRICK TO BE REMOVED TO BOTTOM OF TIE BEAM F __l SEE STRUCTURAL — — I WALK IN COOLER I IL J REMOVE PL.FIX. --------------- RETURN TO OWNER I I _ — — — — — L — I TO BE REMODELED AND RELOCATED I ° U 1 1 I I i SEE FS DWGS. I i I I I FLOOR DRAINS TO REMAIN I I II II I I I III 1 1 I I I I +TY F SOUTH MIA l L ------------J I L------------ I I I Q 1LDING DEPT M 'T UCTURA TION REMOVE EXISTING SECTION OF EXTERIOR WALL DOORS TO BE REMOVED TO CREATE PASS THRU TO NEW ' - - OVED BY: PICK UP WINDOW - - - _zu - EXIST. DRIVE THRU WINDOW TO BE RELOCATED. SEE ARCH'L DWGS. EXIST. DRIVE THRU STRUCTURE TO BE REMOVED. DEMOLITION SCALE: 1/4"= V-0" PLAN ALL IDEAS, DESIGNS, ARRANGEMENTS, AND PLANS INDICATED OR REPRESENTED BY THIS DRAWING ARE OWNED BY, AND THE PROPERTY OF TECTONICS ASSOCIATES, INC. AND WERE CREATED, EVOLVED AND DEVELOPED FOR USE ON, AND IN CONNECTION WITH THE SPECIFIED PROJECT. NONE OF SUCH IDEAS, DESIGNS, ARRANGEMENTS OR PLANS SHALL BE USED BYOR DISCLOSED TO ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF TECTONICS ASSOCIATES, INC. WRITTEN DIMENSIONS OF THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. CONTRACTORS SHALL VERIFY, AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB AND THIS OFFICE MUST BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. SHOP DETAILS MUST BE SUBMITTED TO THIS OFFICE FOR APPROVAL BEFORE PROCEEDING WITH FABRICATION.