ROOFING DEMOLITION NOTES:
1. REMOVE EXISTING ROOF DOWN TO THE WOOD DECK.
2. WHEN ROTTED WOOD DECK EXCEEDS 100 LINEAL FEET
(10 PCS OF V -JOINT) OR 96 SQ.FT. (3 PCS PLYWOOD %").
3. RE -NAIL WOOD DECK WITH 8d(2.5") RING SHANK COIL NAILS.
4. INSTALL ONE PLY OF 75# ASTM FELT PAPER FASTENED
WITH 1.25" R/S COIL NAILS & 1%" ROUND TIN CAPS.
5. INSTALL NEW 3X3 26 GA GALVANIZED EAVE DRIP, ALONG
ENTIRE ROOF EDGE.
6. INSTALL GAF RUBBEROID 201.5 SQ.FT. SMOOTH SBS/HOTMOP.
7. INSTALL GLASS CAP WHITE.
8. INSTALL NEW 16" GALVANIZED VALLEY FLASHING & NEW 26 GA
GALVANIZED COUNTER FLASHING WHENEVER NEEDED.
9. PRIME EAVE DRIP & FLASHING MTL'S WITH ASTM D 41 ASPHALT
PRIMER.
10. INSTALL NEW LEAD FLASHING & ROOF VENTS PENETRATIONS & SEAL
WITH ASPHALT POLYGLASS 500 MEMBRANE AND ALL WHEATHER
FLASHING CEMENT.
11. CLEAN-UP ALL TRASH & DEBRIS AND HAUL AWAY FROM PREMISES.
GENERAL DEMOLITION NOTES:
1. ALL CEILING GRID AND TILES TO BE REMOVED.
2. ALL CEILING TILES TO BE REUSED IF POSSIBLE. (RETURN TO OWNER)
3. QUARY TILE TO REMAIN COVER AND LEVEL WITH LEVELROCK ONLY RENOVATED
KITCHEN AREA, SEE RENOVATED FLOOR PLAN.
4. ALL OTHER FLOOR FINISHES TO BE REMOVED. (INT. AND EXT.)
5. ALL VINYL BASE TO BE REMOVED.
6. ALL TRIM WORK, PANELING AND MOULDING TO BE REMOVED, TO BE DISCARDED.
7. REMOVE ALL LIGHTING FIXTURES, GRILLS, OUTLET AND SWITCH COVERS AND
EQUIPMENT, TO BE RETURNED TO OWNER.
8. ALL FLOORDRAINS TO REMAIN.
9. REMOVE AND CAP -OFF EXISTING PLUMBING FIXTURES.
'REVIEW DEMO SCOPE WITH OWNER PRIOR TO WORK.
ol, DEMOLITION ROOF PLAN
SCALE: 1/4"= 1'-0"
A/C COMPRESOR TO BE RELOCATED
EXISTING PLANTING AREA AIC HANDLER TO BE RELOCATED
A/C HANDLER TO BE RELOCATED TO BE RE -LANDSCAPED. SEE LANDSCAPE.
RELOCATE WH
SEE PLUMB.
=\1 I I----------------------------�I
II
EI(ISTING AHU TO BE
R IS ED AND RELOCATED JI I II I
L------� AGAIIdSTREARwACC----------------------- u
Il
REMOVE PANEL HATCHED AREA INDICATES
AND RELOCATE TO REMOVE/GRIND CONC.
I 1 SEE ELEC. (THIS AREA TO BE LEVEL)
LEAVE CLEARANCE FOR
LJ FINISH MATERIAL,
SEE RENOVATION DWGS.
FLOOR DRAINS TO REMAIN
CLEAN UP & PRESURE I-1
WASH REMAINING FLOOR
& PREPARE TO RECEIVE
SELF LEVELING CONCRETE I I EXISTING COLUMN
TOPPING BY QUICKCRETE I I TO BE REMOVED
OR OTHER APPROVED.
REMOVE EXISTING
I I TILE
II
r
/- FLOOR DRAINS TO REMAIN I I I I EXIST. CMUIBRICK
TO BE REMOVED
TO BOTTOM OF TIE BEAM
F __l SEE STRUCTURAL
— — I WALK IN COOLER I IL J REMOVE PL.FIX.
--------------- RETURN TO OWNER I I
_ — — — — — L — I TO BE REMODELED
AND RELOCATED I ° U
1 1 I I i SEE FS DWGS. I i I I I FLOOR DRAINS TO REMAIN
I I II II I I I
III 1 1 I I I I +TY F SOUTH MIA l
L ------------J I L------------ I I I Q 1LDING DEPT M
'T UCTURA TION
REMOVE EXISTING SECTION OF EXTERIOR WALL
DOORS TO BE REMOVED TO CREATE
PASS THRU TO NEW ' - - OVED BY:
PICK UP WINDOW
- - - _zu -
EXIST. DRIVE THRU WINDOW
TO BE RELOCATED. SEE ARCH'L DWGS.
EXIST. DRIVE THRU STRUCTURE TO BE REMOVED.
DEMOLITION
SCALE: 1/4"= V-0"
PLAN
ALL IDEAS, DESIGNS, ARRANGEMENTS, AND PLANS INDICATED OR
REPRESENTED BY THIS DRAWING ARE OWNED BY, AND THE PROPERTY OF
TECTONICS ASSOCIATES, INC. AND WERE CREATED, EVOLVED AND
DEVELOPED FOR USE ON, AND IN CONNECTION WITH THE SPECIFIED
PROJECT. NONE OF SUCH IDEAS, DESIGNS, ARRANGEMENTS OR PLANS
SHALL BE USED BYOR DISCLOSED TO ANY PERSON, FIRM OR CORPORATION
FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF
TECTONICS ASSOCIATES, INC.
WRITTEN DIMENSIONS OF THESE DRAWINGS SHALL HAVE PRECEDENCE
OVER SCALED DIMENSIONS. CONTRACTORS SHALL VERIFY, AND BE
RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB AND THIS
OFFICE MUST BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND
CONDITIONS SHOWN BY THESE DRAWINGS. SHOP DETAILS MUST BE
SUBMITTED TO THIS OFFICE FOR APPROVAL BEFORE PROCEEDING WITH
FABRICATION.