09-97-004Index of Drawings, Architecture M.E.P. 1. C-1 Cover Sheet 1. E-1 Power & Lighting plan 2. SPA Site plan and calculations 2. E-2 Panel schedules & Riser 3. D-1 Demolition plan 3. M-1 Mechanical plan & Schedules 4. A-1 Floor plan 4. P-1 Plumbing plan 5. A-2 Safety & Reflected ceiling plan 5. P-2 Plumbing risers 6. A-3 Roof plan & Elevations % hr. 7. A-4 Elevations 8. A-5 General details I a O O O M I Y a N O co Ln a, 0 O N N 3 W 0 RENOVATION FOR: Owner- Petrus Food, LLC. Design Team:_ Architectural Design: ONE D+B Construction Documents: Tectonics Associates, Inc. HVAC Consultant: Bob Sulton RCS Contract Services, Inc. (954) 295-2182 Structural Consultant: DAR Projects 18382 SW 135 Ave. Miami, FI 33177 (305) 378-0856 A. Applicable Codes: (Revised 12/12/08) H. 2006 Land Development Code, City of South Miami 2007 Florida Building Code 2000 NFPA 101 Life Safety Code B. Zoning: TODD ( Transit Oriented Development District) LI -4 (Light Industrial 4) C. Permited Use: Small Restaurant (Permitted as Special Use) D. Construction Type: FBC Type III, B I. Unsprinkled E. Occupancy: Mercantile - Group M F. Allowable height and building area (FBC Table 500): Allowable Building Height: 2 stories Allowable Building Area: 13,700 s.f. G. Actual Height and Area of Building: Building Height: Existing 1 stories (19'-1") Building Area: lower floor 1,750 s.f. (Area of Renovation) total 1,750 gross s.f. Code Analysis:_ Fire Resistant Ratings (FBC Table 600): TYPE V Unprotected Fire and Party Walls: 4 -hours Interior Bearing Walls: 0 Interior Nonbearing Walls: 0 Columns: 0 Beams, Girders, Trusses & Arches: 0 Floors & Floor/Ceiling Assemblies: 0 Roofs & Roof/Ceiling Assemblies: 0 Minimum Fire Resistance of Walls, Partitions, and Opening Protectives: SBC Table 705.1.2 walls & partitions opening protectives SHAFT ENCLOSURES less than 4 stories 1 hr. 1 hr. Stair 1 hr. % hr. WALLS AND PARTITIONS exit access corridors 1 (SBC Table 704.2.4) 20 min. Tenant Separation 1 hr. 3/a hr. J. Means of Egress Occupant Load (Table 1004.1.1): Mercantile: 30 gross s.f. per occupant First Floor gross area: 1,750/ 30 = 58 Total Occupants = 58 Total seating provided = 58 b LOCATION PLAN N.T.S. K. Travel Distance, Dead End Length, Exit and Means of Eqress Width (FBC Table 1004 Group B: Maximum Travel Distance: Sprinklered: 300 ft. Maximum Dead End Corridor: 20 ft. Minimum Corridor Width: 44 -inches Minimum Clear Openings of Exit Doors: 32" (door leaf) Egress Width Per Person Served (inches): 0.2 Level (includes ramps, doors and corridors) 0.3 Stairs L. Minimum Plumbing Fixtures (Florida Buildinq Code (2001 Edition))(Table 403.1): Restaurant: Occupancy 58 persons Total required fixtures male female Water closets 1 per 75 = 1 (1 provided) 1 per 75 = 1 (1 provided) Lavatories 1 per 200 = 1 (1 provided) 1 per 200 = 1 (1 provided) Drinking fountains Comply with Board of Health Requirements M. Parking Requierements: Small restaurant 1 space/400 gross sq. ft. 1,750/400=4 Parking Spaces (Requiered) 10 Provided O �pD:ZUNO ZWO �.Z »F- 0MZV) W Y l l N N~ Q J ZpOZ<OJaow�a0 Q W U 0=0W a o J U Z O d J Zwzcn = x J -L'' a ` � Ln OON O VZ'?UOO aW�0_w "UO rr LJJZL=NW�zVi �U <--'0 Wz` 0. wZ V) a- U U 0Z-Z0WL'U waQO�Hd'W0 W>ZQWp0Q] ZpvwwuJawa Wpa0ZV) �-0 V) (.5 U �crLJF: wzwa¢ao 0UMW �y r ax(ro5r Nu,m -M ZmL�OH QF - W U ZX00> 0 UpOW r~ice tnw >� WO <V)Ld W Z H U Z O W O w O >- O a O m U OwaW2w�ao 30Fr L'Jp0ZVa- Wa< -XLLj OZV) 0>o OO LWnw OW <LL)Vap<L �U-,c-mot-� J W W Z a of O ~ W Q O H Z V) O <oLx-0(.52M2IL 3:M0<z0iEm v E 21 zS X t 0 ._ LL ■ 1 c ■ ^ o JBCD H o 00 (n^ U m a LL + 2Lo D da_ N Q to + N ~ c.) Z Z3 W o U Z �° LUm W cn n ZC')+Z O Q M CLO 705020