08-471-029AIR HANDLING UNIT SCHEDULE
DESIGNATION
AHU-I
MANUFACTURER
TRANE
MODEL N0.
4TEE3F37Aiboo,8
TOTAL AIR (CFM)
1300
E.S.P. (IN OF W.G.)
0.4
RPM
VARIABLE
N.P. (F.L.A.)
CEILING
AVAILABLE SERVICE
208/1/60
OUTSIDE AIR (CFM) - INFILTRATION
75
MCA / MOCP (AMP.) (BLOWER)
--
TOTAL COOLING - BTUH (*)
36,000
TOTAL COOLING - SENSIBLE BTUH
28,800
TOTAL HEATING - BTUH
18,800
ELECTRIC NEATER TOTAL KW
5.0
ELECTRIC HEATER NO STEPS
I
DIMENSIONS(L, W, W (INS.)
22 X 24 X 45
WEIGHT (LBS)
142
LIQUID (IN. OD)
3/8
SUCTION (IN OD)
3/4
REMARKS:
I. ALTERNATE MANUFACTURERS OF EQUAL QUALITY MAY
BE SUBMITTED FOR APPROVAL (TRANE, RNEEM, RUUD
OR YORK)
(w) ARI RATINGS BASED ON OUTDOOR TEMPERATURES OF:
SUMMER: 80•F DRY BULB / 67•F WET BULB
WINTER: 70•F DRY BULB
AIR DISTRIBUTION SCHEDULE
FAN SCHEDULE
A
FAN DESIGNATION
EF -I
EF -2
EF -3
AREA SERVED
BATH 3
MBATH
BATH 1/2
LOCATION
CEILING
CEILING
CEILING
MANUFACTURER
NUTONE
NUTONE
NUTONE
MODEL NO.
S50
689
S50
TOTAL AIR (CFM)
50 1
60
50
E.S.P. (INCHES OF WATER)
0.125
0.125
0.125
SONES
0.9
3.5
0.9
RPM
-----
-----
-----
H.P. (A=AMP - W=WATTS)
0.8 A
LI A
0.8 A
VOLT -PH -NZ
120-1-60
120-1-60
120-1-60
DRIVE
DIRECT
DIRECT
DIRECT
BACKDRAFT DAMPER
YES I
YES
YES
INTERLOCK
LIGHT SWITCH LIGHT SWITCH
LIGHT SWITCH
REMARKS
I. ALTERNATE MANUFACTLJPE12S OF EQUAL QUALITY MAY BE
SUBMITTED FOR APPROVAL.
2. UNLESS OTHERWISE NOTED ALL FANS SHALL BE EQUIPPED
WITH SAFETY DISCONNECT SWITCH.
AIR DISTRIBUTION SCHEDULE
DESIGNATION
A
B
C
MANUFACTURER
TITUS
TITUS
TITUS
MODEL AND
250 AA
272 FL
3 FL
CATALOG NO.
ALL ALUM.
ALL ALUM.
ALL ALUM.
FRAME TYPE
SURFACE
SURFACE
SURFACE
IT LINES
(CEILING)
(SIDE WALL)
(CEILING is WALL)
DEVICE TYPE
ADJUSTABLE
DOUBLE
SINGLE
MULTI-PATTEPN
DEFLECTION
DEFLECTION
FUNCTION
SUPPLY
SUPPLY
RETURN E TRANS.
PATTERN
SEE DRAWINGSN/A
AC
N/A
OPPOSED BLADE DAMPERS
I SEE NOTE 4
1 SEE NOTE 4
SEE NOTE 4
REMARKS:
I. ALTERNATE MANUFACTURERS OF EQUAL QUALITY MAY BE SUBMITED FOR APPROVAL.
2. ALL AIR DEVICES SHALL BE ALL ALUMINUM CONSTRUCTION AND FULLY GASKETED.
3. UNLESS OTHERVISE NOTED ALL AIR DEVICES FINISHES SHALL BE BAKED OFF-WHITE
4. SUPPLY,RETURN OR EXHAUST OUTLETS SERVED BY AN INDIVIDUAL DUCT BRANCH
THAT ARE NOT PROVIDED WITH AN ACCESSIBLE: MANUAL VOLUME DAMPER SHALL BE
SUPPLIED WITH INTEGRAL O.B.D.
REFRIGEPAP
CLEANOL
CONDI
DRAIN
!P
n
PET, AIR
DUCT CONN. TO
PLENUM
RETURN AIR PLENUM
TYPICAL A.H.U. MOUNTING DETAIL
N.T.S.
NOTE:
I. PROVIDE SECONDARY DRAIN PAN WITH AN APPROVED
WATER LEVEL DETECTOR OR FLOAT SWITCH DEVICE
THAT WILL CONTROL OVERFLOW BY AUTOMATICALY
SHUTTING DOWN THE AHU'S. FOR SWITCH MANUF. AND
MODEL NO PLEASE REFER TO PLUMBING DRAWINGS.
2. PROVIDE MIN. 4" CLEARANCE ALL AROUND AC UNIT
INSTALLED INSIDE AC CLOSET AS PER FMC 603.1.4
(LING
S PANEL
rURE
HANGER
TO STRUCT
DUCT
CEILING FAN.
AIR COOLED CONDENSING UNIT SCHEDULE
DESIGNATION CU -1
MANUFACTURER TRANE XL -191
MODEL NO. 2TWZ90366I000A
AVAILABLE SERVICE 208-1-60
COMPRESSOR TYPE SCROLL
NO. OF COMPRESSORS I
COMPRESSORS PLA -LRA (EACH) 16.7-82.0
CONDENSER COIL AREA - SO. FT, 16.33
NO. OF CONDENSER FANS 1
CONDENSER AIR (CFM) 3,060
FAN N.P./FLA EACH I/6HP / 1.1 AMP
A.R.I. NOISE RATING - DB 74
TOTAL COOLING - BTUH W 36,000
TOTAL HEATING - BTUH (*) 18,800
S.E.E.P. W/MATCHED ANU (x) 17,90
C.O.P. W/MATCHED AHU (x) N/A
CONDENSING UNIT MCA (AMPS) 220
CONDENSING UNIT MAX. FUSE 36.0
OR CKT. BREAKER AMPS
DIMENSIONS(L, W, H) (INS.) 37 X 34 X 50
WEIGHT (LBS) 440
LIQUID (IN. OD) 3/8
SUCTION (IN OD) 7/8
REMARKS:
I. ALTERNATE MANUFACTURERS OF EQUAL QUALITY MAY BE
SUBMITTED FOR APPROVAL (TRANERHEEM,RUUD OR YORK)
2. PROVIDE TIME GUARD II, START CAPACITOR AND RELAY, LIQUID
LINE FILTER DRYER £ SOLENOID VALVE, 24 V CONTROL
TRANSFORMER is THERMOSTAT WITH SYSTEM "OFF -HEAT -AUTO -
COOL" AND FAN "ON -AUTO" S/S
(.0 ARI RATINGS BASED ON OUTDOOR TEMPERATURES OF
SUMMER: 95• F DRY BULB
WINTER: 44• F DRY BULB
(x) MINIMUM VALUE TO MEET ENERGY CODE
SPEED
CONTROL
CEILING -GRILLE `'JOIST
TOILET EXHAUST FAN DETAIL
N.T_S.
DIRECTION OF
AIR FLT"'
14 (4'MIN.)
?ANCH DUCT
BRANCH DUCT CONNECTION
N.T.S.
WALL OR CONCRETE
3/4" DEEP X 1/8' --1
POWERED ACTUATED,
PINS.
FLEX. DUCT. UP TO
29 ' WITH OPIG"
DEEP.
SLEEVE
WALL CAP W/ BACK DRAFT
E/AIR DUCT -'DAMPER AND BIRD SCREEN
NOTE: BIRD SCREEN MUST BE AVOID
TAPE AND SEALER FOR DRYER WALL CAP
ALL AROUND SILICONE CAULK
n ALL AROUND
WALL CAP MOUNTING DETAIL
N.T.S.
CONDENSING �G
UNIT
u
2\"X2\"XI/4'GALV
ANGLE TYP, OF 4 o
(TWO PEP SIDE)
MIN.
CONCRETE BASE
W/6X6-10/10 WWF
1/2" MEGH. EXPAN51ON 4
GALVANIZED ANCHOR
BOLTS
MINIMUM EMBEDMENT 4"
NOTE SUCTION LINE
W/ 1/2 ARMAFLEX
I- SEAL ENTRANCE OF REFRIGERANT INSULATION £ VAPOR
LINES INTO PVC PIPE W/IMPEPMEABLE, BARRIER
RESILIENT MATERIAL (SEE DETAIL). 1/2" BOLTS AND NUTS
2- AN ANCHOR BOLT W/ MINIMUM 500 LBS PULL OUT
RESISTANCE SHALL SECURE THE AC CONDENSER UNIT
FROM WITHIN THE UNIT THROUGH THE CONC. SLAB ON
WHICH THE UNIT RESTS.(ANTI-THEFT BOLT).
(MDC CH 8-c SEC. 8c-5) C.U. MOUNTING DETAIL
Nts_
AC LEGEND
ATTIC
SPACE.
24X24 CD -(SEE SCHEDULE)
FIRE DAMPER(S)
DUCT TO MATCH NECK SIZE TYP.
�v
CEILING GRILLE SEE SIZE SCHEDULE
FIRE RATED ENCLOSURE
DUCT TO MATCH NECK SIZE TYP.
\-CE
RETURN AIR GRILLE -(SEE SCHEDULE)
�,C
S/AIR DUCT
�-(
TURNING VANES
0
MANUAL VOLUME DAMPER
QT
THERMOSTAT
-WALLS
IT LINES
1 WAY, 2 WAY, ETC., SEE PLANS
-- v- RETURN OR EXHAUST, SEE PLANS.
C)1oO
WALL MOUNTED SIDE REGISTER.
FILTER ACCEE,
T PLUG
EXHAUST FAN
OAL
OUTSIDE AIR INTAKE
&R
TNSATE
CD
CEILING DIFFUSER
AC
ISOMODE PAD
LINE
CONDENSING UNIT
Z
ALL AROUND
TRAP
0
0
(0
a
GALV. STEEL
•i.�
ANGLE STRUC
PET, AIR
DUCT CONN. TO
PLENUM
RETURN AIR PLENUM
TYPICAL A.H.U. MOUNTING DETAIL
N.T.S.
NOTE:
I. PROVIDE SECONDARY DRAIN PAN WITH AN APPROVED
WATER LEVEL DETECTOR OR FLOAT SWITCH DEVICE
THAT WILL CONTROL OVERFLOW BY AUTOMATICALY
SHUTTING DOWN THE AHU'S. FOR SWITCH MANUF. AND
MODEL NO PLEASE REFER TO PLUMBING DRAWINGS.
2. PROVIDE MIN. 4" CLEARANCE ALL AROUND AC UNIT
INSTALLED INSIDE AC CLOSET AS PER FMC 603.1.4
(LING
S PANEL
rURE
HANGER
TO STRUCT
DUCT
CEILING FAN.
AIR COOLED CONDENSING UNIT SCHEDULE
DESIGNATION CU -1
MANUFACTURER TRANE XL -191
MODEL NO. 2TWZ90366I000A
AVAILABLE SERVICE 208-1-60
COMPRESSOR TYPE SCROLL
NO. OF COMPRESSORS I
COMPRESSORS PLA -LRA (EACH) 16.7-82.0
CONDENSER COIL AREA - SO. FT, 16.33
NO. OF CONDENSER FANS 1
CONDENSER AIR (CFM) 3,060
FAN N.P./FLA EACH I/6HP / 1.1 AMP
A.R.I. NOISE RATING - DB 74
TOTAL COOLING - BTUH W 36,000
TOTAL HEATING - BTUH (*) 18,800
S.E.E.P. W/MATCHED ANU (x) 17,90
C.O.P. W/MATCHED AHU (x) N/A
CONDENSING UNIT MCA (AMPS) 220
CONDENSING UNIT MAX. FUSE 36.0
OR CKT. BREAKER AMPS
DIMENSIONS(L, W, H) (INS.) 37 X 34 X 50
WEIGHT (LBS) 440
LIQUID (IN. OD) 3/8
SUCTION (IN OD) 7/8
REMARKS:
I. ALTERNATE MANUFACTURERS OF EQUAL QUALITY MAY BE
SUBMITTED FOR APPROVAL (TRANERHEEM,RUUD OR YORK)
2. PROVIDE TIME GUARD II, START CAPACITOR AND RELAY, LIQUID
LINE FILTER DRYER £ SOLENOID VALVE, 24 V CONTROL
TRANSFORMER is THERMOSTAT WITH SYSTEM "OFF -HEAT -AUTO -
COOL" AND FAN "ON -AUTO" S/S
(.0 ARI RATINGS BASED ON OUTDOOR TEMPERATURES OF
SUMMER: 95• F DRY BULB
WINTER: 44• F DRY BULB
(x) MINIMUM VALUE TO MEET ENERGY CODE
SPEED
CONTROL
CEILING -GRILLE `'JOIST
TOILET EXHAUST FAN DETAIL
N.T_S.
DIRECTION OF
AIR FLT"'
14 (4'MIN.)
?ANCH DUCT
BRANCH DUCT CONNECTION
N.T.S.
WALL OR CONCRETE
3/4" DEEP X 1/8' --1
POWERED ACTUATED,
PINS.
FLEX. DUCT. UP TO
29 ' WITH OPIG"
DEEP.
SLEEVE
WALL CAP W/ BACK DRAFT
E/AIR DUCT -'DAMPER AND BIRD SCREEN
NOTE: BIRD SCREEN MUST BE AVOID
TAPE AND SEALER FOR DRYER WALL CAP
ALL AROUND SILICONE CAULK
n ALL AROUND
WALL CAP MOUNTING DETAIL
N.T.S.
CONDENSING �G
UNIT
u
2\"X2\"XI/4'GALV
ANGLE TYP, OF 4 o
(TWO PEP SIDE)
MIN.
CONCRETE BASE
W/6X6-10/10 WWF
1/2" MEGH. EXPAN51ON 4
GALVANIZED ANCHOR
BOLTS
MINIMUM EMBEDMENT 4"
NOTE SUCTION LINE
W/ 1/2 ARMAFLEX
I- SEAL ENTRANCE OF REFRIGERANT INSULATION £ VAPOR
LINES INTO PVC PIPE W/IMPEPMEABLE, BARRIER
RESILIENT MATERIAL (SEE DETAIL). 1/2" BOLTS AND NUTS
2- AN ANCHOR BOLT W/ MINIMUM 500 LBS PULL OUT
RESISTANCE SHALL SECURE THE AC CONDENSER UNIT
FROM WITHIN THE UNIT THROUGH THE CONC. SLAB ON
WHICH THE UNIT RESTS.(ANTI-THEFT BOLT).
(MDC CH 8-c SEC. 8c-5) C.U. MOUNTING DETAIL
Nts_
HVAC DESIGN REQUIRES=
AC LEGEND
DUCT SMOKE DETECTOR
24X24 CD -(SEE SCHEDULE)
FIRE DAMPER(S)
DUCT TO MATCH NECK SIZE TYP.
�v
CEILING GRILLE SEE SIZE SCHEDULE
FIRE RATED ENCLOSURE
DUCT TO MATCH NECK SIZE TYP.
FIRE RATED POOF/FLOOR CEILING ASSEMBLY
RETURN AIR GRILLE -(SEE SCHEDULE)
�,C
ALL ELBOWS MUST BE PROVIDED WITH
�-(
TURNING VANES
0
MANUAL VOLUME DAMPER
QT
THERMOSTAT
.....••♦
U)
AIR FLOW DIRECTION ( ARROWS DENOTE
1 WAY, 2 WAY, ETC., SEE PLANS
-- v- RETURN OR EXHAUST, SEE PLANS.
C)1oO
WALL MOUNTED SIDE REGISTER.
r
L�J
EXHAUST FAN
OAL
OUTSIDE AIR INTAKE
&R
SIDE REGISTER
CD
CEILING DIFFUSER
AC
AIR CONDITIONING UNIT
Cu
CONDENSING UNIT
HVAC DESIGN REQUIRES=
YES NO
DUCT SMOKE DETECTOR
X
FIRE DAMPER(S)
X
SMOKE DAMPERS)
X
FIRE RATED ENCLOSURE
X
FIRE RATED POOF/FLOOR CEILING ASSEMBLY
X
FIRE STOPPING
X
SMOKE CONTROL
X
I" WIDE X 22 GA
STRAP • 8"-0 O/C
PINS.
VYIL�'L_ A 28 GA
G.M. STRIP AT
SUPPORT.
DUCT HANGER DETAIL
N.T.S.
4
VENT
OVS
RIGID DUCT UP
TO 29" WITH
OR 16" DEEP.
3 WIDE X 28 GA
G.M. STRIP AT
SUPPORT.
HVAC GENERAL NOTES
I. THE CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS AND EQUIPMENT
NECESSARY FOR THE REVISIONS TO NEW HVAC SYSTEM IN
ACCORDANCE WITH THESE DRAWINGS, THE APPLICABLE EDITION OF THE
FLORIDA BUILDING CODE 2004, ALL OTHER APPLICABLE STATE,
COUNTY AND LOCAL ORDINANCES AND THE LATEST EDITION OF THE
FOLLOWING PUBLICATIONS A) ANS B-9.1 MECHANICAL REFRIGERATION,
B) NEPA PAMPHLETS 90A, 90B AND 91, C) SMACNA, D) ASHRAE, E) OSHA AND
THE STANDARD OF CONSTRUCTION ESTABLISHED BY THE EXISTING
INSTALLATION.
2. THE CONTRACTOR SHALL PAY ALL COSTS OF PERMIT, INSPECTIONS AND ALL
OTHER COSTS INCIDENTAL TO THE COMPLETION AND TESTING OF THIS
WORK. UPON FINAL ACCEPTANCE, A CERTIFICATE FROM THE LOCAL
INSPECTION AUTHORITY SHALL BE FURNISHED TO THE OWNER.
3. THE CONTRACTOR SHALL VISIT THE SITE AND FAMILIARIZE HIMSELF WITH
THE LOCATION OF EXISTING EQUIPMENT, DUCTWORK, PIPING, CONDUITS,
ETC., AND/OR ANY CONDITION THAT MAY AFFECT HIS WORK, ALL
NECESSARY RE-ROUTING, RE -LOCATING AND/OR REMOVAL OF EXISTING
EQUIPMENT, DUCTWORK, PIPING, ETC., SHALL BE INCLUDED IN THE SCOPE
OF WORK. ALL MATERIALS USED MUST BE EQUAL TO EXISTING SO
INTEGRITY OF THE INSTALLATION IS NOT CHANGED.
4. ALL MATERIAL AND EQUIPMENTS SHALL BE NEW, OF U.S. MANUFACTURER
AND OF GOOD QUALITY OF RESPECTIVE KIND AND GRADE, AND MUST BE
FURNISHED SO AS TO PREVENT ANY DELAY IN THE PROGRESS OF THE WORK.
ALL WORK THROUGHOUT SHALL BE PERFORMED IN A WORKMANLIKE
MANNER BY SUFFICIENT NUMBER OF SKILLED WORKMEN.
5, CONTRACTOR SHALL COORDINATE HIS WORK WITH ALL TRADES, SPECIALLY
WITH THE EXISTING LOCATION OF STRUCTURAL MEMBERS,
6, NEW THERMOSTATS SHALL BE COMBINATION COOLING/HEATING, WITH
SYSTEM "COOL -AUTO -NEAT -OFF" AND FAN "ON -AUTO" SELECTOR SWITCHES.
USE HONEYWELL OR APPROVED EQUAL.
7. UNLESS OTHERWISE NOTED, FAN COIL UNITS SHALL BE MOUNTED HUNG
FROM THE STRUCTURE MEMBERS ABOVE WITH VIBRATION ISOLATORS.
CONDENSING UNIT SHALL BE PROPERLY ANCHORED TO THE CONCRETE PAD
TO WITHSTAND HURRICANE FORCE WINDS.
8. REFRIGERANT PIPE INSULATION I" FOAMED PLASTIC INSULATION SHALL
BE PROVIDED FOR SUCTION LINES, WITH APPROVED PROTECTIVE FINISH
WHEN EXPOSED TO WEATHER. FIRE RATING NOT TO EXCEED 25 FOR FLAME
SPREAD AND 50 FOR FUEL CONTRIBUTED AND SMOKE DEVELOPED
MANUFACTURER Al2MAFLEX OR APPROVED EQUAL.
9. REFRIGERANT PIPING SHALL BE COPPER, TYPE L HARD DRAWN (ASTM -B-88)
WITH WROUGHT COPPER, SOLDER JOINT TYPE FITTINGS, USE 95/5 SOLDER.
REFRIGERANT PIPING SHALL BE SIZED IN ACCORDANCE WITH EQUIVALENT
PIPE LENGTH FOR PRESSURE DROP EQUIVALENT TO ONE DEGREE
FAHRENHEIT. I" FOAMED PLASTIC INSULATION SHALL BE PROVIDED FOR
SUCTION LINES, WITH APPROVED PROTECTIVE FINISH WHEN EXPOSED TO
WEATHER. FILTER/DRYER AND SIGHTGLASS SHALL BE PROVIDED AT LIQUID
LINES.
10. CONTPACTOR SHALL BE RESPONSIBLE TO TEST E BALANCE THE HVAC
SYSTEM AS PER ASSOCIATED AIR BALANCE COUNCIL STANDARDS.
11. CONTRACTOR SHALL PRINT UP INSTRUCTIONS FOR OWNER'S OPERATION OF
SYSTEM, STATING THE ITEMS COVERED BY HIS GUARANTEE AND THE
EQUIPMENT MANUFACTUPER'S GUARANTEE.
12. AIR CONDITIONING DUCTWORK SHALL BE ONE INCH STANDARD DUTY, FOIL REINFORCE
FIBERGLASS WITH MANUFACTURER'S LOGO PRINTED ON VAPOR BARRIER, KNAUF TYPE
475 DUCTBOAPD-M- WITH 1.5 INCH THICK AND AN INSTALLED R -VALUE OF 8.0 OR
APPROVED EQUIVALENT, INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURER'S
RECOMMENDATIONS. ALL OUTSIDE AIR VENTILATION AND EXHAUST DUCTWORK SHALL
BE CODE GAGE GALVANIZED SHEET METAL. DUCT SIZES SHOWN APE NET FREE AREA.
PROVIDE DOUBLE THICKNESS TURNING VANES AT ALL ELBOWS.
TYPE OF DIFFUSER
F1_50 1 W DIRECTION OF FLOW
6
_ SIZE OF DIFFUSER
AMOUNT OF CFM
:INSIDE AIR OUTLET TAG
)M N.T.S.
EXHAUST VENT DETAIL - THROUGH OVERHANG
N.T.S.
1/8" STAINLESS STEEL WIRE
WRAP APPOUND CONDENSING UNIT
(DADE COUNTY ORDINANCE 86-5).
POWER is CONTROL
LOCATION
LIQUID LINE W1 0
INSULATION
NOTES:
1, INSTALL CONDENSING UNIT E:ITI-EP ABOVE THE BASE
FLOOD ELEVATION LEVEL OR PROTECTED SO AS TO
PREVENT WATER FROM ENTERING OR ACCUMULATING
WITHIN THE CONDENSING UNIT DURING FLOODS UP TO
THE BASE FLOOD ELEVATION.
2. INSTALLATION MUST MEET MINIMUM OF 146 MPH WIND
LOADING. MIN. REQUIREMENTS ARE HEREBY INDICATED
HOWEVER BASED ON ACTUAL EQUIPMENT INSTALLED
EPA (EFFECTIVE PROJECTED AREA) ADDITIONAL
SECURING SHALL BE PROVIDED
UPPER ATTACHMENT
PER SMACNA.
FLEXIBLE: DUCT
6' MIN - 10' MAX
LENGTH
MAXIMUM D/8 OFFSET
ALLOWED IN LAST
EXHAUST VENTS AND DUCT NOTES
I. CLOTHES DRYER EXHAUST DUCT SHALL "NOT" BE SCREENED.
2. CLOTHES DRYERS EXHAUST DUCTS (OR VENTS) SHALL COMPLY WITH
MANUFACTURER'S INSTALLATION INSTRUCTIONS, BE CONSTRUCTED OF A
MIN, 26 GAUGE METAL PIPE, HAVING A SMOOTH INTERIOR SURFACE WITH
JOINTS RUNNING IN THE DIRECTION OF THE AIR FLOW. DUCT JOINTS
SHALL NOT BE ASSEMBLED WITH SHEET METAL SCREWS OR OTHER
FASTENERS WHICH WOULD EXTEND INTO THE DUCT.
ROUND SPIN -IN COLLAR
MOUNT IN SIDE OF DUCT
UNLESS SPECIFICALLY
SHOWN OTHERWISE
ADJUSTABLE CLAMP
MAX. SAG 1/2" PER FOOT
BETWEEN SUPPORT POINTS
D INCHES TO DEVICE `- SEE NOTE 3
WHERE D IS THE ADJUSTABLE CLAMP
INTERNAL FLEX
DIAMETER DUCT SEALER
NECK SIZE TO
MATCH FLEX
DUCT SIZE
INDICATED
CEILING
(T -BAR SHOWN,
GYP -BOARD SIMILAR).
INSULATE TOP PANEL OF
LAY -IN DIFFUSER. SEAL INSULATION
TO DIFFUSER- NOT TO T -BAR GRID
1�
AIR DISTRIBUTION DEVICE, SEE
SCHEDULE. (LAY -IN SHOWN,
SURFACE MOUNT SIMILAR).
FLEXIBLE DUCT DETAIL
NTS
DUCT SEALER AT SPIN
COLLAR CONNECTION TO
MAIN
SUPPLY DUCT SIZE:
AS SHOWN ON PLANS
VOLUME DAMPER WITH LOCKING
QUADRANT AND 2" STANDOFF
1
24'X 24"
CEILING ACCESS PANEL
FOR DAMPER ACCESS IN
NON -ACCESSIBLE CEILINGS.
FLEXIBLE DUCT NOTES
I. FLEXIBLE DUCTS SHALL BE ONE-PEICE AND SHALL NOT BE SPLICED TOGETHER
2. EXTEND FLEXIBLE DUCT INSULATION TO DUCT/DIFFUSER PANEL INSULATION AND SEAL WITH MASTIC
3, MINIMUM I" WIDE 22 GALVANIZED STRAP HANGER WITH HEMMED EDGES PEP SMACNA, FIGURE 3-10
4. FLEXIBLE AIR DUCT SHALL BE FULLY EXTENDED AND NOT COMPRESSED WITH ELBOW RADIUS NO
LESS THAN P/D = 1.0 .
a • r«v•• ccv
•••• ••• •• GV i • •
• W
•••• • • V Q • •••••
♦ • 4 V • • V «
• • 00000
♦ • Y « • • • V �'
• u4i • r
• « V
• r �•u r •
a••r ••••• ••• •c
•
TFS
:009w • « V
• •
• •
4 r • • •
V V•• V •• r•• V • V r V •'
CITY Of SOUTH PJIIl &II
BUILDING DLpT.
A1EC)3ALAICAL SECTION
GUIROLA & ASSOCIATES P.A.
CONSULTING ENGINEERS
P.E. No 57468
David Guirola
ce] ElectriC21 Engineer
1150 NW 72nd AVE, S-451
MIAMI, FLORIDA 33126
R.H: (305)513.9665
CA 00005112 EMAIL: GUIRO 5(_WAOL.COM
MAW
TELEPHONE (305) 2"7231 FAX (305) 285-6722
535 SW $ ST, SUITE 100 MIAMI, FL. 33130
DESIGN I CONSTRUCTION ADMINISTRATION
BUILDING INSPECTIONS I CAD PRODUCTION
CONSULTANT/ NOTES
APPROVALS/REVISIONS DATE
W
z
C)
(y)
Irl -
UJ
ODcoM
0
z
W
C�
.....••♦
U)
W
a
W
C)1oO
0.%
U)
z
-
WQ
uj
Z
r
uj�
KSS
0
0
(0
a
•i.�
SEAL:
y wi•i• i
�., . 00
i'
Mmrk A Coltroin AR 0013380
Richard K. Jones, AIA AR 0015755
SHEET TITLE:
MECHANICAL
FLOOR PLAN
Job No. Drawing No.
2007 - JONES RESIDENCE
Drown By:
I- S.
Date dotted:
10/15/2007
Scall:
/vuiec _ crr nw�wiur_l
IPIRPI