08-40-278
PL\JMBING GENERAL NOTES 1. ALL WORK i0 BE DONE IN ACCORDANCE WITH THE FLORIDA PLUMBING AND BUILDING CODES. 2. PLUMBING CONTRACTOR SHALL GUARANTEE ALL WORK FREE OF DEFECTS IN MATERIALS AND WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM DATE OF ACCEPTANCE, 3. ALL PIPING SHALL BE INSTALLED RECESSED IN BLOCK WALLS, CHASES OR PARTITIONS. 4. PLUMBING CONTRACTOR SHALL PAY ALL FEES, INSPECTION AND CONNECTION CHARGES REQUIRED. 5. COORDINATE ALL WORK WITH OTHER TRADES. 6. PROVIDE SHOCK ABSORBERS SIZE, QUANTITY AND LOCATION AS PER P.D.I. STANDARDS. 7. PROVIDE SHUT-OFF VALVE FOR EACH GROUP OF FIXTURE AND EACH FIXTURE SUPPLY. B. WHEREVER DISSIMILAR METALS ARE TO BE JOINED, A DIELECTRIC FITTING SHALL BE PROVIDED TO CONNECT BOTH TYPES OF PIPES. 9. CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE ALL ROUGH -INS WITH THE MANUFACTURER BEFORE MAKING ANY INSTALLATION. 10. POTABLE HOT AND COLD WATER SYSTEMS SHALL BE "LEAD FREE" WITH LEAD CONTENT NOT EXCEEDING 0.2 PERCENT FOR SOLDER AND FLUXES AND 1 PERCENT FOR PIPE FITTINGS, FIXTURES AND TRIM. CONTRACTOR SHALL VERIFY MANUFACTURER'S COMPLIANCE. 11. ALL POTABLE HOT AND COLD WATER SYSTEMS SHALL BE FLUSHED CLEAR, STERILIZED WITH AN APPROVED SOLUTION AND THROUGHLY FLUSHED OF ALL RESIDUAL SOLUTION AFTER FINAL PRESSURE TESTS AND WITH ALL TRIM AND CONNECTIONS INSTALLED. 12. PROVIDE SHUT-OFF AND VACUUM BREAKER TO ALL HOSE BIBBS AND FAUCETS WITH HOSE -END CONNECTIONS. 13. ALL FLOOR DRAINS SHALL HAVE TRAP PRIMERS TO PROTECT THE SEAL OF THE TRAP. 14. PVC PIPING IS NOT ALLOWED IN RETURN AIR PLENUMS. IF RETURN AIR PLENUMS ARE USED, CONTRACTOR SHALL REPLACE ALL EXISTING PVC PIPING WITH CAST IRON OR COPPER PIPING. 15. DRAINAGE SYSTEM DESIGN IS BASED ON 1/9" PER FOOT MINIMUM FALL FOR PIPES 3" OR LARGER AND 1/4" PER FOOT MINIMUM FALL FOR PIPES 2" OR SMALLER, ANY DEVIATIONS SHALL BE APPROVED BY ARCHITECT/ENGINEER. 16. ALL VENT THROUGH ROOF OPENINGS SHALL BE OFFSETED TO A MINIMUM DISTANCE OF 3'-0" FROM PARRAPET WALL OR ROOF EDGE. SEE ARCHITECTURAL DRAWINGS FOR ROOF FLASHING. LEAD FLASHING WILL NOT BE ACCEPTED. 17. ALL MATERIAL SHALL BE NEW, UNUSED, BEST OF THEIR RESPECTIVE KINDS AND FREE FROM DEFECTS IN WORKMANSHIP; IN CONFORMANCE WITH THE LATEST PUBLICATIONS IN FORCE AT TIME OF BIDDING. 11. PIPE AND FITTINGS: A. SANITARY SOIL AND VENT PIPING (ABOVE GROUND): SERVICE WEIGHT CAST IRON BELL AND SPIGOT PIPE AND FITTINGS, ASTMI A74-75; NO HUB CAST IRON PIPE AND FITTINGS, CISPI. 301-72, OD DWV. COPPER PIPE WITH CAST BRASS OR WROUGHT COPPER SOLDER JOINT FITTINGS, ASTM. 1306-79, (ABOVE GROUND). VENTING AS HEREIN BEFORE SPECIFIED OR GALVANIZED THREADED STEEL WITH MALLEABLE IRON FITTINGS. 1. DRAINAGE WASTE, VENT k GREASEWASTE PIPING (UNDERGROUND): PVC DRAINAGE WASTE AND VENT PIPING (DWV) CONFORMING TO ASTM D-2665 AND CAST IRON HUN, PLAIN END ASTM A-74 WITH NEOPRENE GASKETS UNDERGROUND, PROVIDE PIPE HANGERS ON HORIZONTAL PIPING ABOVE CEILING NOT TO EXCEED 6 FT ON CENTER. NO PVC PIPING SHALL ME ALLOWED IN RETURN AIR PLENUM. C. WATER PIPING: COPPER TYPE " L" ASTM 1-85 ABOVE GROUND, COPPER TYPE K ASTM 1-I6 UNDERGROUND. PROVIDE ADJUSTABLE PIPE HANGERS ON HORIZONTAL OVERHEAD PIPING ABOVE CEILING NOT TO EXCEED 6 FT. ON CENTER D. CONDENSATE PIPING: AS HEREIN BEFORE SPECIFIED FOR SANITARY SOIL, WASTE AND VENT PIPING. E. STORM DRAIN PIPING: AS HEREIN BEFORE SPECIFIED FOR SANITARY SOIL, WASTE AND VENT PIPING. 19. JOINTS AND METHODS OF CONNECTION: A. CAST IRON BELL AND SPIGOT PIPE: COMPRESSION GASKET. INSTALL PER MANUFACTURER'S RECOMMENDATION. GASKET AND PIPE BY SAME MANUFACTURER. B. CAST IRON NO -HUN PIPE: MAKE JOINTS WITH NEOPRENE RUBBER SLEEVE AND STAINLESS STEEL RING CLAMP PER MANUFACTURER'S RECOMMENDATIONS. GASKET AND PIPE NY SAME MANUFACTURER. C. DWV CORER PIPE: JOINT WITH 95-5 TIN -ANTIMONY SOLDER, INSTALL PER MANUFACTURER'S RECOMMENDATIONS. D. TYPE 'L' COPPER TUBE: JOIN WITH 95-5 TIN -ANTIMONY SOLDER, INSTALL PER MANUFACTURER'S RECOMMENDATIONS. E. STEEL PIPE s. THREADED JOINTS: AFTER CUTTING AND BEFORE THREADING, REAM ALL PIPE AND REMOVE BURRS. MAKE JOINTS WITH JOINT COMPOUND APPLIED TO MALE THREADS ONLY. 6. FLANGED JOINTS: STANDARD WEIGHT, 150 P.S.I. STEEL, WITH APPROVED RED RUNNER GASKET OR NEOPRENE RUBBER GASKET, INSTALL AS PER MANUFACTURER'S RECOMMENDATIONS. 4. UNIONS AND FLANGES: A. COPPER PIPE: BRONZE UNIONS FOR 2 INCHES AND SMALLER. FOR 2-1/2 INCHES AND LARGER USE BRONZE FLANGED CONNECTIONS 150 POUND CLASS. 1. DIELECTRIC UNIONS OR FLANGES: UNIONS SHALL MEET DIMENSIONAL REQUIREMENTS AND TENSILE STRENGTH OF PIPE UNIONS IN ACCORDANCE WITH FED. SPEC. WW -U-531 E. UNIONS OR FLANGES SHALL BE SUITABLE FOR REQUIRED OPERATING PRESSURES AND TEMPERATURE CONDITIONS. UNIONS SHALL HAVE METAL CONNECTIONS ON BOTH ENDS. ENDS SHALL BE THREADED OR SOLDERED TO MATCH ADJACENT PIPING. METAL PARTS OF UNION OR FLANGED SHALL BE SEPAREATED TO PREVENT CURRENT FLOW BETWEEN DISSIMILAR METALS. EPCO DIELECTRIC PIPE FITTINGS OR EQUIVALENT. 20. ESCUTCHEONS: CHROME PLATED OR STAINLESS STEEL WITH SET SCREWS FOR HOLDING SECURELY IN PLACE. USE ESCUTCHEONS ON PIPES PASSING THROUGH WALLS, FLOORS AND CEILINGS OF FINISHED AREAS. A. ALL CONDENSATE LINES SHALL BE INSULATED WITH 3/4" FIRE RETARDANT ARMAFLEX INSULATION WITH A MAXIMUM OF 25/50 FLAME SPREAD AND SMOKE DEVELOPED RESPECTIVELY. 1. ALL HOT WATER AND TEMPERED WATER LINES SHALL BE INSULATED WITH 1" FIRE RETARDANT ARMAFLEX INSULATION WITH A MAXIMUM OF 25/50 FLAME SPREAD AND SMOKE DEVELOPED RESPECTIVELY. C. HORIZONTAL STORM DRAIN PIPING SHALL BE INSULATED WITH TWO-PIECE, RIGID PREFORMED, HEAVY DENSITY FIBERGLASS PIPE INSULATION AND FACTORY APPLIED REINFORCED FOIL VAPOR WIRIER, ALL SERVICE JACKET WITH SELF-SEALING LONGITUDINAL LAP AND BUTT ADHESIVE JOINTS, -60 TO 450 DEGREE F. NON-COMBUSTIBLE. 22. TRAP PRIMER SHALL BE SELF PRIMING TYPE ON COLD WATER SUPPLY LINE AS MANUFACTURED NY PRECISION PLUMBING PRODUCTS, INC. "PRIME -RITE" #PR -500. WHEN TWO OR MORE TRAPS REQUIRE PRIMING, PROVIDE WITH DISTRIBUTION UNIT #DU -2, 3 OR 4 AND SUPPLY TUBE #SS -B ASSEMBLY. PROVIDE ACCESS PANEL AND INSTALL AS PER MANUFACTURER'S RECOMMENDATION. 23. FLOOR DRAINS: AS MANUFACTURED BY JOSAM. A. FD -1: JOSAM 30000-A SERIES WITH 6"x6" SQUARE NIKALOY TOP AND 1/2" TRAP PRIMER CONNECTION. 24. PERFORM THE FOLLOWING TEST: WATER PIPING SHALL BE SUBJECTED TO A HYDROSTATIC PRESSURE TEST OF 100 PSIG FOR A PERIOD OF TIME SUFFICIENT TO EXAMINE THE ENTIRE SYSTEM, BUT NOT LESS THAN ONE HOUR. A. DRAINAGE SYSTEM: NEFORE THE INSTALLATION OF ANY DRAINS, THE ENDS OF THE SYSTEM SHALL BE CAPPED AND ALL LINES FILLED WITH WATER TO THE HIGHEST POINT AND ALLOWED TO STAND UNTIL INSPECTION IS MADE AND WATER LEVELS REMAIN CONSTANT. 1. CORRECT ALL DEFECTS DISCLOSED BY ABOVE TESTS. C. COMPLETE SYSTEM, FIXTURES AND EQUIPMENT SHALL BE GIVEN AN IN-SERVICE TEST AFTER COMPLETION OF THE INSTALLATION. D. STERILIZE ALL WATER LINES WITH A MIXTURE OF (2) POUNDS OF CHLORINATED LIME FOR EACH 1000 GAL. OF WATER (50 RM OF AVAILABLE CHLORINE). RETAIN MIXTURE IN PIPES FOR 24 HOURS AND FLUSH THROUGHLY WITH POTABLE WATER BEFORE PLACING IN SERVICE. 25. DOMESTIC WATER PACKAGE PUMP SINGLE-SOURSE RESPONSANILITY : RUMPS SHALL BE MANUFACTURED BY THE BOOSTER MANUFACTURER.THE ENTIRE PACKAGE SHALL BE PARTY CERTIFIED BY UNDERWRITERS LABORATORIES INC. DESIGN CRITERIA. DESING CRITIRIA. THE DRAWINGS INDICATE SIZES, PROFILES CONNECTIONS AND DIMENSIONAL REQUIREMENTS OF PLUMBING AND ARE BASED ON SPESIFIC MANUFACTURES TIRES AND MODELS INDICATED. PUMPS HAVING EQUAL PERFORMANCE CHARACTERISTICS BY OTHER MANUFACTURES MAY BE CONSIDERED ,PROVIDED THAT DEVIATIONS IN DIMENSIONS AND PROFILES DO NOT CHANGE THE DESING INTENT AND PREFORMANCE AND JUDGED BY THE ENGINEER. THE BURDEN OF PROOF FOR EQUALITY IS ON THE PROPOSER. DELIVERY AND STORAGE. STORE PUMPS IN A DRY LOCAZTION. RETAIN SHIPPING FLANGE PROTECTIVE CORVERS AND PROTECTIVE COATINGS DURING STORAGE PROTECT BEARINGS AND COUPLINGS AGAINST DAMAGE FROM SAND, GRIT AND OTHER FOREING MATTER, COMPLY WITH MANUFACTURES' RIGGING INSTRUCTIONS FOR HANDELING. PART II: PRODUCTS CONSTANT PRESUSURE, VARIABLE SPEED DOMESTIC WATER BOOSTER SISTEM FURNISH AND INSTALL ONE FACTORY PREFABRICADED AND TESTED SERIES 6901 VARIABLE SPEED BOOSTER SYSTEM AS MANUFACTURED BY ARMSTRONG PUMPS INC. THE SYSTEM SHALL BE CAPABLE OF PROVIDING A C05NSTANT SYSTEM PRESSURE AND PUMP FLOW RATED AS SHOW BELOW_ TAG NUMBER MODEL I FLOW USGPM HEAD FT SPEED GPM POWER HP NP -1 6524 185 151 13500 13 BP -2 6524 185 151 1 3500 13 DWHT FX -500 132 GALLON 150# NON ASME CLOSE -COUPLED VERTICAL; IN -LINES PUMPS PUMP CASING SHALL BE CAST IRON, BRONZE FITTED SUITABLE FOR 250 WORKING PRESSURE AT 140 F. THE CASING SHALL BE RADIALLY SPLIT TO ALLOW REMOVAL OF THE ROTATING ELEMENT WHITOUT DISTURBING THE PIPE CONNETIONS. THE CASING SUCTION AND DISCARGE CONNECTIONS SHALL BE THE SAME SIZE AND SHALL BE PROVIDED WITH DRILLED AND TAPPED SEAL VENT AND PRESSURE GAUGE CONNTECTIONS. PUMP IMPELLER SHALL BE BRONZE, FULLY ENCLOSED TYPE . IMPELLER SHALL BE DYNAMICALLY "CED. A BRONZE SHAFT SLEEVE, EXTENDING THE FULL LENGTH OF THE MECHANICAL SEAL ARE, SHALL BE PROVIDE. MECHANICAL SEAL SHALL BE SINGLE SPRING INSIDE TYPE WITH CARBON AGAINST O-RING MOUNTED NI -RESIST FACES. EPDM ELASTOMER WITH STAINLESS STEEL SPRING AND HARDWARE SHALL BE PROVIDE. SEAL VENT LINE SHALL BE FACTORY INSTALLED AND SHALL BE PIPED FROM THE PUMP SUCTION CONNETION. MOTTORS SHALL BE OF NEMA N DESING, AND OF THE OPEN DRIP -PROOF (STANDARD), PREMIUN EFFICIENCY TYPE. PUMP CONTROL VALVES EACH PUMP SHALL BE EQUIPPED WIHT ISOLATION VALVES ON THE SUCTION AND DISCHARGE, THE DISCHARGE VALVE SHALL BE LOCATED AFTER A SOFT SEATING CHECK VALVE. NO PRESSURE REDUCING VALVES SHALL BE REQUIRED. PUMP SEQUENCIG THE PUMP DESINGNATED AD THE LEAD PUMP WILL START AFTER 5 SECOND ON -DELAY. THE PUMP CONTROLLER COMPARES A SIGNAL FROM THE DISCHARGE PRESSURE TRASNDUCER TO THE DESIRED SET POINT VALVE. THE LEAD PUMP SPEED WILL RAMP UP IN ORDER TO SATISFY THE SET POINT PRESSURE. ONCE THE LEAD PUMP EXCEEDS IT'S BEST OPERATING POINT (101) THE FIRST LAG PUMP IS STARTED FOLLOWING A 5 SECONG TIME DELAY. ONCE THE LAG PUMP IS CALLED ON A MINIMUN RUN TIMER BEGINS COUNTING TO ENSURE THAT THE PUMP RUNS FOR A MINIMUM OF 5 MINUTES. WHENTHE 2 PUMPS ARE RUNNING AND ARE OPERATING AT A POINT BELOW THE AND THE LAG PUMP MINIMUM RUN TIMER HAVING TIMED OUT, THE LAG PUMP WILL RAMP DONW IN SPEED AND TURN OFF. THE LEAD PUMP WILL CONTINUE TO OPERATE AND MEET SYSTEM REQUIREMENTS BASED ON THE POINT PRESSURE. STEPS 2-5 ARE REPEADED IN ORDER TO SATISFY THE NULDING REQUIREMENTS. THE LEAD PUMP WILL BE ALTERNATED AFTHE EVERY 24 HRS OF OPERATION. A TIME CLOCK WILL BRING ON THE SECOND PUMP, FOR A PERIOD OF 5 SECONDS BOTH PUMPS WILL OPERATE AT WHICH POINT THE FIRST PUMP ON WILL BE SHUT OFF. LEAD PUMP SHUTDOWN CONTROLS AND PUMP OVER -TEMPERATURE PROTECTION AN AQUASTAT CONNETED TO THE PUMP SEAL CHAMBERS MONITORS THE WATER TEMPERATURE M ENERGIZES A SOLENOID THAT WILL ALLOW WATER TO DRAIN AND PREVENT THE PUMPS FROM OV( NTING DURING LONG PERIODS OF LOW DEMAND. SYSTEMS EQUIPPED WITH A "NO FLOW" SHUTDONW WILT J') WHEN THE PUMP CONTROLLER DETERMINES THERE HAS BEEN A "NO FLOW" CONDITION FOR A C01_ '',AUS 2 - MINUTE PERIOD. THE LEAD PUMP WILL START AGAIN ONCE A DROP IN PRESSURE OF AT LEAST 5 PS IS' ;. MEASURED ON THE DISCHARGE OF THE SYSTEM. THE SYSTEM CAN BE MANUALLY OPERATED NY MEANS OF THE VIRTUAL HOA SELECTOR BUTTONS PROVIDED ON THE TOUCH SCREEN OPERATOR INTERFACE. POWER AND CONTROL PANEL CONTRLLERS ARE HOUSED IN A NEMA TYPE1 ENCLOSURE WHIT NEMA TYPE 4 TOUCH SCREEN OPERATOR INTERFACE AND ONE MAIN DISCONNECT. CONTROL PANEL IS EQUIPPED WITH VIRTUAL HAND -OFF -AUTO CONTROL SWITCHES ON DISPLAY PANEL FOR USE CONTROLUF PUMP MOTORS, AND VARIABLE FREQUENCY DRIVES, CONTROL PANEL IS COMPLETE WITH 3 LEG OVERLOAD AND CIRCUIT PROTECTION, .120V CONTROL CIRCUIT TRANSFORMER AND INTEGRALFUSED 24 VOLT CONTROLLER POWER SUPPLY. AMBIENT ENVIRONMENTAL RATINGS FOR THE CONTROLLER SHALL BE is A MINIMUN, 0"c TO 6Tc AND 5 X TO 95% RELATIVE HUMIDITY, NON CONDENSING. THE CONTROL PANEL SHALL BE COMPLETE WITH 3.5"BY 4.5" LIQUID CRISTAL, WATERTIGHT TOUCH SCREEN OPERATOR INTERFACE WITH EASY TO READ BACKLIT DISPLAY. THE OPERATOR INTERFACE SHALL HAVE PASSWORD PROTECTOR SISTEM PARAMETERS, ON-SCREEN DISPLAY OF PUMP SYSTEM PARAMETERS SUCH AS SYSTEM PRESSURE (PSI), SURLY PRESSURE (PSI),THREE PHASE VOLTAGES, THREE PHASE AMPERAGES, PUMP RUN STATUS, OPERATING RPM. ALL SYSTEM PARAMETERS ARE VISIBLES ON SCREEN ON ONE SCREEN WHITHOUT HAVING TO SCROLL. ACCESS TO THE INSIDE OF THE NOT REQUIRED TO CHANGE SYSTEM PARAMETER SETTINGS, ALARM SETTINGS OR RESET ALARMS. SYSTEM PARAMETERS CAN BE MONITORED WITHOUT ADDITIONAL TOOLS OR DEVICES OR THE NEED TO OPEN CONTROL PANEL DOOR. CONTROLLER DESIGN SHALL INCLUDE PROVISIONS FOR FLOW ENERGY SAVINGS, BEST OPERATING POINT (NOP) SEQUENCING, END OF PUMP CURVE PROTECTION, 24 HR AUTOMATIC ALTERNATION OF THE PUMPS, BUILT-IN PUMP ON -DELAY AND MINIMUN RUN TIMERS, RE-SETTABLE PUMP ELAPSED RUN TIME METERS. SMOOTH PUMP STARING AND SEQUENCING, ON-SCREEN MODIFIABLE CONTROL AND ALRMAN PARAMETERS, NO -FLOW SHUTDONW AND DRAWDOWN TANK OPTIMIZATION. ON-SCREN ALARM DISPLAY WITH ALARM LOG FIRST ON IDENTIFICATION SHALL BE INCORPORATED WITH THE FOLOWING ALARMS INCLUDED; MOTOR OVERLOAD LOW SYSTEM PRESSURE SHUTDOWN, HIGH SYSTEM PRESSURE SHUTDOWN, LOW SUCTION PRESSURE SHUTDOWN,HIGH SUCTION PRESSURE SHUTDOWN,PUMP FAILURE, CONTROLLER FAILURE,VFD FAILURE SUCTION OR DISCHARGE PRESSURE TRANSMITTER FAILURE,MOTOR OVER/ UNDERVOLTAGE. THE CONTROLLER SHALL INCLUDED ON-SCREEN FAULT DESCRIPTION AND POSSIBLE CAUSE INFORMATION AS WELL AS AUDIBLE ALARM HORN. NON-VOLATILE FACTORY SET PARAMETERS MUST BE CAPABLE OF BEING RESTORED AT ANY TIME IN THE FIELD WITHOUT REQUIRED ANY PROGRAMATION DEVICE OR CONNECTION TO EXTERNAL SOURSE. THE CONTROLLER MUST HOLD SOFTWARE IN EPROM. EPROM MEMORY STORAGE PREVENT ACCIDENTAL LOSS OF DATA DUE TO VOLTAGE SURGE OR SPIKE. THE FOLOWING REMOTE INDICATION,N/0 CONTACTS SHALL BE INCLUDED: INDIVIDUAL PUMP STATUS DRIVE/MOTOR FAILURE,LOW SYSTEM PRESSURE, HIGH SYSTEM PRESSURE, LOW SYSTEM PRESSURE OR LOW SUPPLY LEVEL VARIABLE SPEED DRIVES SUPPLUES SHALL HAVE THE FOLLOWING FEATURES; DETACHABLE OPERATOR PANELS, SCREWLESS CONTROL TERMINALS, LATEST IGNT TECHNOLOGY, DIGITAL MICROCOMPRESSOR CONTROL, FLUX CURRENT CONTROL (FCC)FOR IMPROVED DYNAMIC REPONSE AND OPTIMIZED MOTOR CONTROL PROGRAMMABLE v/f CHARACTERISTIC,FLYING RESTAT, SUP COMPENSATION FAST CURRENT LIMIT (FCL)FOR TRIP FREE OPERATION. COMPOUND BRAKING FOR RAPID CONTROLLER BRAKING, 50% OVERLOAD CAPACITY FOR A PERIOD OF 60 s WITHIN 5 MIN RELATION TO THE RATED CURRENT. OVERVOLTAGE/UNDERVOLTAGE PROTECTION, INVENTER OVER -TEMPERATURE PROTECTION, EARTH FAULT PROTECTION, SHORT CIRCUIT PROTECTION,% MOTOR THERMAL PROTECTION, LOCKED MOTOR PROTECTION,SHALL PREVENTION, PARAMETER INTERLOCK USING PIN NUMBER. ALL CONTROL TO BE FACTORY PRE -WIRED AND ACCORDANCE WITH PROVISIONS OF THE NATIONAL ELECTRICAL CODE. ALL CONTROL WIRES SHALL BE INDIVIDUALLY NUMERED AND EACH COMPONENT SHALL BE LABELED ACCOERDINGLY. ALL INTERNAL WIRING SHALL BE COPPER STRANDED.A.W.G. WIHT A MINIMUN 90DEG. F RATING. THE CONTROLLER SHALL NEAR THE UL508 LABEL INDUSTRIAL CONTROL, COMMUNICATIONS INTERFACE FACTORY PREFABRICATION THE SYSTEM SHALL BE FACTORY FABRICATED, INCLUDING INSOLATION VALVES ON SUCTION AND DISCHARGE EACH PUMP. ALL PIPING AND VALVES ON THE DISCHARGESIDE OF THE PUMPS SHALL BE RATED TO 175psi. THE ONLY FIELD CONNECTIONS REQUIRED SHALL BE PIPING TO THE SYSTEM HEADERS, OVER TEMPERATURE DRAIN TUBE PIPING, AND ONE INCOMING POWER CONNEC71ON AT THE CONTROL PANEL FACTORY TEST AND CERTIFICATION THE BOOSTER SYSTEM AND ITS COMPONENT PART SHALL UNDERGO A COMPLETE OPERATION FLOW TEST FROM ZERO TO 100 DESING FLOW RATE UNDER THE SPECIFIED SUCTION AND NET SYSTEM PRESSURE CONDITIONS. THE SYSTEM CERTIFICATION SHALL INCLUDE COPIES OF THE TEST DATA AS WITNESSED BY A FACTORY ENGINEER PERFORMANCE TEST CERTIFICATIONS SHOUL BE PLACED INSIDE THE SYSTEM CONTROL PANEL AND EXTRA COPIES WITH INSTALLATION MANUAL IN ADDITION , THE ENTERY SYSTEM SHALL BE THIRD PARTY CERTIFIED BY UNDERWRITERS LABORATORIES INC. IN ACCORDANCE WITH OSHA 29 CFR WHICH REFERENCES NATIONALLY RECOGNIZED TESTING LABORATORIES. SUBMITTAL DATA THE SUBMITTAL DATA FOR THE PUMPING SYSTEM SHALL INCLUDE, BUT NOT LIMITED TO: PUMP CURVES INDIVIDUAL COMPUTER DATA SHEETS, SYSTEM DRAWINGS AND COMPLETE DESCRIPTIONS OF CONTROL PANEL, WITH WIRING DIAGRAM SEQUENCING DATA, INSTRUMENTATION, AND ALARMS GUARANTEE THE PUMPING SYSTEM SHALL BE GUARANTEED IN WRITTING BY THE MANUFACTURE FOR A PERIOD OF ONE YEAR FROM DATE OF START-UP AGAINST DEFECT IN DESIGN, MATERIAL, OR CONSTRUCTION. START-UP SERVICE THE SERVICE OF THE FACTORY TRAINED REPRESENTATIVE SHALL BE MADE AVAILABLE ON THE JON SITE TO CHECK INSTALLATION AND START-UP AND INSTRUCT OPERATING PERSONNEL. SYMBOL CD -- SD - OSD - RWL ORWL LI- HB VTR CO -- FCOFD �- W/TPRE- COOG FD V 0 0 RD 0 ORD -FOS- ' FOR - 0 PLUMBING LEGEND i; i � Mf • ° � v r„ DESCRIPTION Vv" •0� Y y Vi Y V V � v SANITARY WASTE PIPING � uc�Yc •Y� COLD WATER PIPING (CW) *(duo „° (d • V 40 V�eiV f 4V4V• • `Y•i• • VYVV" SANITARY VENT PIPING CONDENSATE DRAIN PIPING STORM DRAIN PIPING OVERFLOW STORM DRAIN PIPING RAIN WATER LEADER OVERFLOW RAIN WATER LEADER GATE VALVE CHECK VALVE "P" TRAP HOSE BIBS (HB) PLUMBING FIXTURE CONNECTION SCHEDULE DESCRIPTION VSASTE C.W. H.W. COLD HOT Y- l- V SYMBOL DESCRIPTION DRAIN WATER WATER MANUFACTURER/MODEL TRIM 1/21P P -1A WATER CLOSET 4" 1/2" -- A. fowl: Floor mounted, siphon jet, 1.5 gal Ion to 1.6 gallon per flush, standard height uXiu u Y V M • ANTISCALD, PRESSURE BALANCING VALVE (HANDICAP) LAVATORY 1-1/2- 1/2" vitreous china closet bowl with elongated rim, 1 -1 /2 inch top spud. COUNTER TOP P-4 KITCHEN SINK 1-1/2" 1/2" 1/2" 1. Kohler #K-4350 'Welcome Lite" REF REFRIGERATOR- � z -4t 1 /2" - PROVIDE SHUTOFF VALVE 2. American Standard #2234.015 "Madero" EL 1.6 B. Flush Valve: 11 inch high exposed chrome plated, chemical and clog resistant diaphragm with ADA metal oscillating handle, cast escutcheon with set screw, seat bumper, integral screwdriver atop, vandal resistant cap, vacuum breaker, pipe support, 1.6 gallon per flush. y y 3. Sloan Royal #113 -YB 4. ZurnAquaVantage#Z-GOOOAV-I-WSI-YK-YO C. Flush Valve (Faculty, Public Group Toilets and Other Areas Not Mentioned Above): 11-1/2 inch high exposed chrome plated, chemical and clog resistant diaphragm with ADA metal oscillating handle, cast escutcheon with set screw, seat bumper, Integral screwdriver stop, vandal resistant cap, vacuum breaker, pipe support, 1.6 gallon per flush. 1. Sloan Royal #111 -YB 2. Zurn AquaVantage#Z-6000AV-WSI-YK-YO D. Seat: Solid white fire -resistant plastic, open front, self -sustaining hinge, brass belts and without cover. 1. Sporzal#50EW-SSCH 2. Olsonite *10CC/SS/FR P-1 WATER CLOSET A. Bowl: Floor mounted, siphon jet, 1.5 gallon to 1.6 gallon per flush, standard height vitreous china closet bawl with elongated rim, 1-1/2 inch top spud. 1. Kohler #K-4350 "Welcome Lita" 2. American Standard *2234.015 "Madero" EL 1.6 ■. Flush Valve (Elementary School Classroom Toilet, Clinic and Student Group Toilet ADA Stall Only): 16 inch high exposed chrome plated, chemical and clog resistant diaphragm with ADA metal oscillating handle, cast escutcheon with set screw, seat bumper, integral screwdriver stop, vandal resistant cap, vacuum breaker, pipe support, 1.6 gallon per flush. 1. Sloan Royal #11 3-Y3 2. Zurn AquaVantage #Z4000AV-I-WSI-YK-Y0 B. Flush Valve (Faculty, Public Group Toilets and Other Areas Not Mentioned Above): 11-1/2 inch high exposed chrome plated, chemical and clog resistant diaphragm with ADA metal oscillating handle, cast escutcheon with set screw, seat bumper, integral screwdriver stop, vandal resistant cap, vacuum breaker, pipe support, 1.6 gallon per flush. 1. Sloan Roysl #111-YB 2. Zurn AquaVantage *Z-C000AV-WS1-YK-YO C. Seat: Solid white fire-resistant plastic, open front, self-sustaining hinge, brass bolts and without cover. 1. Sparzel *50EW-SSCH 2. Olsonite #1 OCC/SSIFR P -2A URINAL 2" (HANDICAP) WATERLESS URINAL P-2 URINAL 2" WATERLESS URINAL P -3A LAVATORY 1 1/4' 1/2' 1 /2" A. Basin: 20 inch x 1 a inch wall hung with floor -mounted concealed arm carrier, acid - (HANDICAP) resisting, enameled cast iron lavatory with 4 inch centers. 1. Kohlsr#K-2167 "Hudson" 2. CECO #551A B. Faucet: Adjustable slaw closing push button metering faucet for CW only, 4 Inch canter, deckplato, 2.0 GPM vandal resistant f low control and internal stream regulator. 1. Zurn #Z86300-CP4-2M 2. TTS #8-805 C. Supply Riser: 3/8 inch chrome plated angle stop with loose key stop, rigid riser, escutheon plate and brass chrome plated nipples. 1. Zurn #Z -8810 -LR -LK 2. McGuire #158LK D. Grid Drain: Offset perforated wheelchair lavatory drain assembly with a 1 -1 A inch tailpiece. 1. Zurn *Z-8746 2. McGuire #155 -WC 3. Keenly #K570OPC E. P -Trap: 1-1/2 inch x 1-112 inch chrome plated with swivel joint and cleanout. 1. Zurn *Z -8701-1J 2. McGuire #3112 3. Keeny *530710C F. Carrier: Steel upright with cast iron arms. 1. J.R. Smith*0712-M34 2. Zorn #Z-1236 P-3 LAVATORY 1 1/4" 1/2" 1/2" A. Basin: 19 inch x IQ inch oval countertop, self -rimming, enamel cast iron lavatory with 4 inch centers. 1. Kohler #K-2916 "Farmington" 2. CECO #596 IN. Faucet: Adjustable slow closing push button metering faucet for CW only, 4 inch center, deckplate, 2.0 GPM, vandal resistant flaw control and internal stream regulator. 1. Zurn #Z86300-CP4-2M 2. TTS #3-805 C. Supply Riser: 3/8 inch chrome plated angle supply with loose key stop, rigid riser, escutcheon plate and brass chrome plated nipples. 1. Zurn #Z -8810 -LR -LK 2. McGuire #158LK D. Grid Drain: Lavatory drain assembly with a 1-1/4 inch tailpiece. 1. Zurn #Z4743 2. McGuire *155-A 3. Keeny #K5680PC E. P -Trap: 1-1/2 inch x 1-1/2 Inch chrome plated with swivel joint and cleanout. 1. Zurn #Z-8701-9 P_5 SINK 1-1/2 " 1/2" 1/2" MOP SINK OF PRECAST FIAT "TERRAZO" P-4 MOP SINK 3 " 1/2" __ MODELTSBC-1610 FLOOR MOUNTED WITH STAINLESS STEEL TRESHOLD ONLY WITH 3" PERFORATED STRAINER SS. SERVICE FAUCET: FIAT# 830-M CHROME PLATED FINISHED WALL MOUNTED, WITH VACUM BREAKER SOLID CAST BRASS DODY, BRASS SPOUT WITH PAIL HOOK. MOP HANGER 819 -CC HOSE AND HOE BRACKET # 832-M P-5 DRINKING FOUNTAIN 1-1/2 " 1/2" �- HALSEY TAYLOR REF: HRFSEBP BARRIER -FREE SPLIT-LEVEL RATED CAPACITY B GPH, 4.6 AMPS FULL LOAD , 1/4H.P. COMP. STAINLESS STEEL BOTTOM TOPS WATERWAY ARE LEAD-FREE IN MATERIALS 0 CONSTRUCTION FLEXI-GUARD SAFETY BUBBLER. FD FLOOR DRAIN 4" -- -- JOSAM SERIES # 3000 TOILET ROOMS PROVIDE FIXTURE WITH 1/2" TRAP PRIMER AND INSIDE CAULK OUTLET FOR LEAD AND OAKUM JOINT. TP TRAP PRIMER -- 1/2" -- PRECISION PLUMBING PRODUCTSJNC HEAVY DUTY TRENCH DRAIN TD - 1-_ TRENCH DRAIN 4„ MEAJOSAM CHANNEL 100 G 22 W/ CAST IRON SLOTTED GRATIN" SYMBOL CD -- SD - OSD - RWL ORWL LI- HB VTR CO -- FCOFD �- W/TPRE- COOG FD V 0 0 RD 0 ORD -FOS- ' FOR - 0 PLUMBING LEGEND i; i � Mf • ° � v r„ DESCRIPTION Vv" •0� Y y Vi Y V V � v SANITARY WASTE PIPING � uc�Yc •Y� COLD WATER PIPING (CW) *(duo „° (d • V 40 V�eiV f 4V4V• • `Y•i• • VYVV" SANITARY VENT PIPING CONDENSATE DRAIN PIPING STORM DRAIN PIPING OVERFLOW STORM DRAIN PIPING RAIN WATER LEADER OVERFLOW RAIN WATER LEADER GATE VALVE CHECK VALVE "P" TRAP HOSE BIBS (HB) WATER HAMMER ARRESTOR VENT THRU ROOF CLEAN OUT FLUSH FLOOR CLEAN OUT FLOOR DRAIN WITH TRAP PRIMER CLEAN OUT ON GRADE FLOOR DRAIN VENT TRAP PRIMER (RESEAL) TO CLOSEST FIXTURE ROOF DRAIN OVERFLOW ROOF DRAIN FUEL OIL SUPPLY PIPING FUEL OIL RETURN PIPING NOTE: SYMBOLS INDICATED MAY NOT BE USED ON DRAWINGS PLUMBING FIXTURE CONNECTION SCHEDULE MARKS DESCRIPTION VSASTE C.W. H.W. REMARKS/SPECS P-1 Y- l- V V ii••il G�4i V i M M V V W 1/21P 1 /2" VALVE P -2A SHOWER V Y uXiu u Y V M • WATER HAMMER ARRESTOR VENT THRU ROOF CLEAN OUT FLUSH FLOOR CLEAN OUT FLOOR DRAIN WITH TRAP PRIMER CLEAN OUT ON GRADE FLOOR DRAIN VENT TRAP PRIMER (RESEAL) TO CLOSEST FIXTURE ROOF DRAIN OVERFLOW ROOF DRAIN FUEL OIL SUPPLY PIPING FUEL OIL RETURN PIPING NOTE: SYMBOLS INDICATED MAY NOT BE USED ON DRAWINGS PLUMBING FIXTURE CONNECTION SCHEDULE MARKS DESCRIPTION VSASTE C.W. H.W. REMARKS/SPECS P-1 WATER CLOSET `" 1/2" - FLOOR MOUNTED, FLUSH TANK P-2 TUB 2' 1/21P 1 /2" VALVE P -2A SHOWER 2" 1/219 1/221 ANTISCALD, PRESSURE BALANCING VALVE P-3 LAVATORY 1-1/2- 1/2" 1/2" COUNTER TOP P-4 KITCHEN SINK 1-1/2" 1/2" 1/2" DOUBLE COMPARTMENT REF REFRIGERATOR- � z -4t 1 /2" - PROVIDE SHUTOFF VALVE ALL PLUMBING FIXTURES SHALL COMPLY WITH FPC TABLE 604.4 i DOMESTIC WATER PACKAGE PJMP SCHEDULE PUPM No SERVICE-'OMESTIC WATER LOCATION Pl ,rp�M, PUMP RM, GPM 85 85 HEAD. (FT) -= 58 .� T - 2 r !60 .14 �UttiS1p1" N G NP051? 4 43 ^ �t o � U c \ 6 LL U � C A � O � w c o !n 45 4i v' O ti VJ en O M O N t M W 4. o O � M o i+i M 6 N 0 4; r o K � w U � W � U � � z LJL, Imo,, " I I i�l�ll"ti ARCHITECTURE INTERIOR DESIGN PLANNING SEAL MONEY J. MATED AR 0008220 JMM CONSULTING ENGINEERS, LLC M.E.P. 12651 S DIXIE HIGHWAY, SUITE 2D9 MIAMI, FLORIDA 33156 M.A. SUAREZ CONSULTING ENGINEERS STRUCTURAL ENGINEERING 4869 SW 75TH AVENUE MIAMI, FLORIDA 33155 PISTORINO & ALAM CONSULTING ENG. INC. CIVIL ENGINEERING 7171 SW 62ND AVENUE, 4TH FLOOR MIAMI, FLORIDA 33143 I "w OXFORD UNIVERSAL , �. 4311 PONCE DE LEON BLVD. CORAL GABLES, FLORIDA 33146 3 - 5966 SOUTH DIXIE BUILDING i 5966 & 5970 SOUTH DIXIE HIGHWAY MIAMI, FLORIDA 33133 t MATEU ARGHITEq,TURE INC THII DRAWING IS. TME 'PROPERTY OF MATEU ARCHITECTURE INC- UNLESS OTHERWISE PROWEI! FO tfY CONTRACT. THE CONTENTS OF THIS D WING ARE CONFIDENTIAL AND SHALL NOT BE RANSMITTED TO ANY PARTY EXCEPT AS AUTHORIZED BY THE ARCHITECT/ENGINEERS OF RECORD- PHASE PERMIT DRAWINGS FILE NAME, P-205.DWG PROJECT NO. MA0605 DRAWN BY JMM CHECKED BY: JMM _ Is AVE: DECEMBEJ� f'u©7 - r