Loading...
08-40-273GAS METER & REGU BY GAS C WATER HAMMER 1-1 /2" ARRESTOR (YP.) P-1 Pl I I \ 1n 'P=3 1/2" PP=3 \� "3ENERATOR ,246 MBTU) (S;,45 FIFING 150�lf=-tfRIG N.T.S. GAS DESIGN CRITERIA GAS TYPE: NATURAL GAS TOTAL DEMAND: 246 MSH TOTAL EQUIV. LENGTH: 36' WORKING PRESSURE: LESS THAN 1 PSI PRESSURE DROP: 0.5" WATER COLUMN SPECIFIC GRAVITY: 0.60 NOTE: PIPE SIZES BASED ON FSC TABLE 402(6) WATER HAMMER I �1-1/2" 1 ARRESTOR (TYP.) i PP=1 P 1 L�� ' P � P=2 I P=3 P,=3 1" P_' '\ r L3/4r L1 • �1 /2• I1 /2" 1Z " -1-1/2n p_5 INSTANTANEOUS I • r " WATER HEATER A ; 1-3/4 my t r1 /2 P -3A P, LT 1-1/2" 2_1/2" W ren r-1-1/4" P -2A P- 4" L1 " v-1 /2" 3/4"J 3/4"fi II � _ 3/4" HR I t _ W/ VB 1" CW LINE CAPPED—/ FOR FUTURE TENANT 1" CW LINE CAPPED 1 FOR FUTURE TENANT 1-1/2" CW LINE CAPPED FOR FUTURE TENANT 1-1/2" CW LINE CAI FOR FUTURE TENANT 3t - P -4 "P-4 1/2 yr 1/2" DOMESTIC WATER' PACKAGE SYSTEM (SEE SCHEDULE) I V II 1 L „A" l 4" WATER SERVICE "A" 1� 11 3/4" HEI / VB L1-1/2" 1/2's SHUT-OFF VALVE IN CO NC. VALVE BOX _, 'L1" CW LINE CAPPED �� 1 CW LINE CAPPED FOR FUTURE TENANT FOR FUTURE TENANT cr 1-1 /2" 1" CW LINE CAPPED FOR FUTURE TENANT 1" CW LINE CAPPED FOR FUTURE TENANT +---1-1 /2" , ks?0- FV 1" CW LINE CAPPED FOR FUTURE TENANT 1" F�• 1" CW LINE CAPPED FOR FUTURE TENANT 1" CW LINE CAPPED FOR FUTURE TENANT 1" CW LINE CAPPED FOR FUTURE TENANT 1" CW LINE CAPPED 3 4" HB FOR FUTURE TENANT VB 1" CW LINE CAPPED FOR FUTURE TENANT D0t_lE5_'1G w.~4_rEz_iR fi IFING; 11501*lEz_'r RIG N.T.S. IL1" CW LINE CAPPED FOR FUTURE TENANT 'Ll" CW LINE CAPPED FOR FUTURE TENANT 1-1/2" J� T HB W/ VB W #26000522 v V w C F" U • i q ,w. V U V U V y � C W u • Vj = ti w w V 6V♦ 'J vi • W • •ire Wim' q W ti v a h to 4 � � M O N r= h C M W J Y_ � r V 6 d � w � O N O � M p r � W C W � N H � W o AL PC t w ARCHITECTURE INTERIOR DESIGN PLANNING SEAL: RONEY J. MATEU AR 0008220 JMM CONSULTING ENGINEERS, LLC M.E.P. 12651 S DIXIE HIGHWAY, SUITE 209 MIAMI, FLORIDA 33156 M.A. SUAREZ CONSULTING ENGINEERS STRUCTURAL ENGINEERING 4169 SW 75TH AVENUE MIAMI, FLORIDA 33155 RISTORINO & ALAM CONSULTING ENG. INC. CIVIL ENGINEERING 7171 SW 62ND AVENUE, 4TH FLOOR MIAMI, FLORIDA 33143 OXFORD UNIVERSAL 4311 PONCE DE LEON BLVD. CORAL GABLES, FLORIDA 33146 5966 SOUTH DIXIE BUILDING 5966 & 5970 SOUTH DIXIE HIGHWAY MIAMI, FLORIDA 33133 MATED ARCHITECTURE INC. THIS DRAWING IS THE PROPERTY OF MATED ARCHITECTURE INC. UNLESS OTHERWISE PROVIDED FOR BY CONTRACT. THE CONTENTS OF THIS DRAWING ARE CONFIDENTIAL AND SHALL NOT I TRANSMITTED TO ANY PARTY DCEPT AS AUTHORIZED BY THE ARCHITECT/ENGINEERS OF RECORD - PHASE PERMIT DRAWINGS FILE NAME: P-202.DWG PROJECT NO: MA0605 DRAWN BY JMM I CHECKED BY: JMM ISSUE DATE: DECEMBER 10, 2007 REVISIONS A BD COMMENTS 06-02-08 _ t _ I SHEET TITLE I DOMESTIC WATER PIPING ISOMETRIC SHEET: OF: P-202 12