Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
6835 SW 67 ST EB-09-019-031
oO LO I CID Co m Ln o t*7 T-t °o o 00 W DIFFUSER SCHEDULE � o w TYPE SERVICE CFM RANGE SIZE NECK MANUFACTURER MODEL co LO � MINI MAX co I~ O c 0 100 6X6 6 010 TITUS 250 AA C) 101 200 10x8 $"0 TITUS 250 AA � O . � O SUPPLY 201 300 10x10 10"o TITUS 250 AA y 301 400 14x10 10"o TITUS 250 AA 401 500 14x14 12"0 TITUS 250 AA SPLIT a A/C UNIT SCHEDULE TITUS 250 AA 501 700 16x16 12"0 UNIT DESIGNATION AHU#1 AHU#2 AHU#3 AHU#4 AHU#5 AHU#6 r� r- AREA SERVED 70 185 8X6 -- TITUS 350RS Partial 1st Floor Partial 1st Floor Partial 1st Floor Partial 1st Floor Partial 1 st Floor Partial 1st Floor SUPPLY, 186 225 10X6 -- TITUS 350RS Master Area West South South East Family/Kitchen � e SIDE DICH. 226 240 8X8 -- TITUS 350RS LOCATION A/C CLOSET A/C CLOSET A/C CLOSET A/C CLOSET A/C CLOSET A/C CLOSET 0 LOUVER 241 270 12X6 -- TITUS 350RS DESIGN MANUFACTURER TRANE c TRANE TRANE TRANE TRANE TRANE 271 295 14X6 -- TITUS 350RS MODEL N0. 4TEE3D07B1 4TEE3D05B1 4TEE3D07B1 4TEE3D05B1 4TEE3D07B1 4TEE3D10B1 SEER 20.0 Cb 296 340 12X8 -- TITUS 350RS 20.0 20.0 20.0 20.0 20.0 TOTAL AIR, CFM 1,600 1,200 1,600 1,200 1,600 1.800 0 100 8x8 -- TITUS 350 FL z EXT. STATIC PRESS., INCHES OF H2O 0.4 0.4 0.4 0.4 0.4 0.4 101 200 12x10 -- TITUS 350 FL FAN MOTOR H.P. (NON-OVERLOAD) 3/4 1/2 3/4 1 2 3/4 1/2 w Uj ELECTRIC HEAT, KW 7.0 4.0 5.5 5.5 7.0 7.0 201 300 12x12 -- TITUS 350 FL Z TOTAL CAPACITY, BTUH 47,000 35,800 47,000 35.800 47,000 58,500 HVAC NOTES 301 400 14X14 -- 11TUS 350 FL TOTAL SENSIBLE CAPACITY, BTUH 34,800 27,400 34,800 27,400 34,800 40,500 1. GENERAL RETURN/EXHAUSI 401 500 18X14 __ ¢ 67 ENTERING AIR TEMP. F DB/WB 80 CEILING TITUS 350 FL / 80/67 $0/67 80/67 80/67 80/67 __ ___ ___ L MODEL NO. a'�q o•4,� A. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE FLORIDA OR SIDE WALL 501 600 24x14 TITUS 350 FL FLA/RLA 6.8 - --- 4.3 6.8 4.3 6.8 4.3 o 0 zi 04.2v BUILDING CODE AND WITH ALL APPLICABLE REGULATIONS. 601 700 32x12 ELECTRICAL SERVICE 208-230/1/60 ��� � k B. DRAWINGS: REFER TO ALL DRAWINGS FOR COORDINATION OF THE HVAC WORK. -- TITUS 350 FL 208-230/1/60 208-230/1/60 208-230 1 60 208-230/1/60 208-230/1/60 . o o 701 1000 36x12 OPERATING WEIGHT, LBS. 176 H 21-4 0-." a o ARRANGE AND PAY FOR ALL PERMITS LICENSES, INSPECTIONS AND TESTS. TITUS 350 FL 130 176 130 176 121 r, � �• � 0 � � OBTAIN THE REQUIRED CERTIFICATES AND PRESENT TO OWNER. 1001 1800 30x18 UNIT DIMENSIONS H X W X D (IN) 58 X 26 X 21 52 X 26 X 21 58 X 26 X 21 m °� °; ,G w 52X26X21 58X26X21 63X26X21 �Ao9MOb - A 'D D. GUARANTEE: THE COMPLETED INSTALLATION SHALL BE FULLY GUARANTEED -- TITUS 350 FL Ga 0 0 0 ;~ g AGAINST DEFECTIVE MATERIALS AND/OR IMPROPER WORKMANSHIP FORA 1801 2000 36x34 UNIT DESIGNATION CU#1 CU#2 CU#3 CU#4 CU#5 CU#6 of U 4' o �b b k 4J p, MINIMUM OF ONE YEAR FOR MATERIAL AND LABOR. COMPRESSORS SHALL BE -- TITUS 350 FL DESIGN MANUFACTURER z 0 0 0 8 � a°� GURANTEED FOR A PERIOD OF FIVE YEARS. TRANE TRANE TRANE TRANE TRANE TRANE b a� a� m E. AS BUILT DRAWINGS SHALL BE SUBMITTED TO OWNER AT THE COMPLETION MODEL N0. 4TTZO048A1 (XI-201) 4TTZO036A1 (XI-201) ( ) ( ) 4TTZ0048A1 (XL2Q1) 4TTZ0060A1 (XL201) v a� �+.9 a) V OF PROJECT. AREA/DUCT WITH ( ) ( ) 4TTZ0048A1 (XI-201) 4TTZ0036A1 (XI-20 o g'g 0 ,� >%4J a, o d NOMINAL CAPACITY (TONS) q 0 3.0 4 p 3.0 4 0 5 b &1 p,�0', � a 0 A4a 2. SHOP DRAWINGS: CONTRACTORS SHALL SUBMIT FOR APPROVAL, WITHIN 30 DAYS 25 CFM/LF 0.048SF/2" -- TITUS CT-480 �- TYPE OF FAN PROPELLER PROPELLER H 0 q s., AFTER SIGNING CONTRACT, A MINIMUM OF FIVE COPIES OF FULLY DESCRIPTIVE O SUPPLY LINEAR 50 CFM LF 0.066SF 2.5' - PROPELLER PROPELLER PROPELLER m / / - TITUS CT-480 PROPELLER oy o o ,,.a 0 0 o LITERATURE, INCLUDING BUT NOT LIMITED T0: FANS, AIR CONDITIONING UNITS, AIR OUTLETS. BAR .� D N0. OF FANS AND HP / 1_1 3 1-1/3 1-1 3 1-1 3 E'�., � ° � �,� � a o 90 CFM/LF 0.121 SF/4 -- TITUS CT-480 1-1 3 1-1 3 rx NO WORK SHALL PROCEED WITHOUT APPROVAL OF THESE SUBMITTALS. IF APPLICABLE. 125 CFM AF 0.157SF 5" -- Z CONDENSING TEMP., F DB 95' 95' g5• 95' g5• 95' / / 11TUS CT-480 3. DESIGN PARAMETERS: NO. OF COMPRESSORS 150 CFM/LF 0-194SF/6 -- TITUS CT-480 Z 1/SCROLL 1/SCROLL 1/SCROLL 1 SCROLL 1/SCROLL 1/SCROLL A. OUTDOOR DESIGN TEMPERATURE (SUMMER): 91'F DB AND 77F WB Z CY COMPRESSORS R.L.A. L.R.A. 18.6 93.4 13.8 61.5 18.6 93.4 13.8 61.5 18.6 93.4 22.8 128.7 B. OUTDOOR DESIGN TEMPERATURE (WINTER): 46F C. INDOOR DESIGN TEMPERATURE (SUMMER): 75T OB AREA/DUCT WITH 0 CAPACITY REDUCTION � � 0-100% 0-100% 0-100% 0-100% 0-100% 0-100% A D. INDOOR DESIGN TEMPERATURE (WINTER): 70F OB °w MCA MOCP 26 40 19 30 26 4O 19 30 �'j p RETURN LINEAR 40 CFMIAF 0.066SF/2.5 -- TITUS CT-480 26 40 31 50 L '- 4. ALL THERMOSTATS SHALL HAVE HEATING MODE MAXIMUM SETTING OF 75 F, AND E o ELECTRICAL SERVICE 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 208-230/l/60 O BAR 70 CFM/LF 0.103SF/3.5 -- TITUS CT-480 a COOLING MODE MINIMUM SETTING OF 70 F. THE THERMOSTAT SHALL BE ARRANGED 150 CFM/LF 0.194SF/6" TITUS CT-480 0 OPERATING WEIGHT,LBS. 420 335 420 335 420 480 TO PREVENT THE SIMULTANEOUS OPERATION OF HEATING AND COOLING. w 5. ELECTRICAL CONTROLS AND POWER WIRING: UNDER ELECTRICAL CONTRACT. 0 UNIT DIMENSIONS H X W X D (IN) 54X35X38 54X35X38 54X35X38 54X35X38 54X35X38 54X35X38 IP EF.PIPES SIZE; GAS I LIQ. 7 $ 3 8 3/4 13/8 7 $ 3 8 3/4 13/8 7 8 3 8 7 8 3 8 / i / 6. EQUIPMENT SPECIFIED BY MANUFACTURER'S NUMBER SHALL INCLUDE ALL E F.TYPE; CHARGE (lb-oz) R-41OA; 15-7 R-41OA; (9-13) R-41OA; 15-7 R-410A; (9-13) R-41OA; (1-9-7114 R-410A• 13-15 ACCESSORIES, CONTROLS, ETC., LISTED IN THE CATALOG AS STANDARD WITH THE EQUIPMENT. OPTIONAL OR ADDITIONAL ACCESSORIES SHALL BE FURNISHED AS 1 SEE DETAIL SHEET(S) FOR ADDITIONAL INFORMATION SPECIFIED. 2 PROVIDE ALL UNITS NTH OPPOSED BLADE DAMPERS NOTES: 7. MATERIALS: 3 DIFFUSER RUNOUT SIZE SHALL BE DIFFUSER NECK SIZE, UNLESS OTHERWISE NOTED 1. ALL AIR HANDLER UNITS SHALL BE PROVIDED WITH FACTORY INSTALLED CIRCUIT BREAKER. A. REFRIGERANT PIPING: SHALL BE TYPE L SOFT DRAWN, COPPER TUBING, ON PLANS 2. ALL THERMOSTATS/HUMIDISTAT SHALL BE PROGRAMABLE TYPE. DEHYDRATED FOR REFRIGERANT USE. SIZED AS SHOWN ON DRAWINGS OR AS 4 ALL SUPPLY AIR DIFFUSER AIR THROW PATTERNS ARE 4-WAY UNLESS OTHERWISE 3. ALL AIR HANDLER UNITS SHALL BE PROVIDED WITH INTEGRATED WHOLE HOUSE AIR CLEANER AND UV-LIGHT PER AIR CONDITIONING EQUIPMENT MANUFACTURER'S RECOMMENDATIONS. INDICATED ON MECHANICAL PLANS 4. STANDARD LINE LENGTHS-80'. STANDARD LIFT-25', SUCTION & LIQUID LINE. B. INSULATION: REFRIGERANT SUCTION PIPING SHALL BE INSULATED WITH 5 PROVIDE SURFACE MOUNT HARDWARE IN ALL INACCESSABLE CEILING SYSTEMS 1/2" THICK FOAMED PLASTIC INSULATION, FIRE RETARDANT TYPE. INSULATION SHALL BE INSTALLED IN PIPING BEFORE ASSEMBLY. NO SPLIT 6 PROVIDE LAY-IN MOUNT HARDWARE IN ALL SUSPENDED CEILING SYSTEMS INSULATION WILL BE ACCEPTABLE. SEAL JOINTS WITH MANUFACTURER'S APPROVED ADHESIVE AND GREY TAPE. 7 PROVIDE FULL LENGTH PLENUM FOR SIDEWALL AND LINEAR SLOTS C. DUCTWORK: 8 REFER TO ARCHITECTURAL REFLECTED CEILING PLAN FOR LOCATIONS OF DIFFUSERS A. ALL HVAC DUCT WORK SHALL BE FIBERGLASS DUCT BOARD, FABRICATED 9 PROVIDE SELECTION BASED ON A MAXIMUM RADIATED NOISE OF NC-22 AND INSTALLED AS PER LATEST EDITION OF SMACNA "FIBROUS GLASS 10. FURNISH AND INSTALL APPROPIATE HARDWARE TO CONNECT FLEX WITH DIFFUSER NECK DUCT MANUAL". 1-1/2" THICK (R-6.0) IN UNCOND. SPACE ABOVE AND 1" THICK (R-4.2) IN COND. SPACE ABOVE. ALL DUCT WORK TO BE WITH ANTI MICROBIAL COATING. B. ALL EXHAUST DUCTWORK SHALL BE GALVANIZED SHEET METAL DUCT NOT LIGHTER THAN 26 GAGE. FAN SCHEDULE y� C. ALL DUCT DIMENSIONS ARE CLEAR INSIDE DIMENSIONS. UNIT DESIGNATION EF-1 EF-2 �`1 D. FLEXIBLE INSULATED DUCTWORK WITH 1 1/2" FIBERGLASS MASTER INSULATION WITH FRK VAPOR BARRIER, CLASS 1 AIR DUCT, U.L AREA SERVED BATHROOM R-6.0 MIN. BATHROOM Q E-4 E. DRYER DUCTWORK: 26 GA. MIN. GALVINIZED STEEL HAVING A OPERATING WEIGHT, LEIS 12 16 HVAC SYMBOL LEGEND �' co SMOOTH INTERIOR SURFACE WITH JOINTS RUNNING IN THE DIRECTION HVAC DESIGN REQUIRES: YES NO W OF AIRFLOW AND WITHOUT SHEET METAL SCREWS OR OTHER FASTNERS CEILING IN THE AIR STREAM. MAXIMUM LENGTH SHALL NOT EXCEED 25 FEET. LOCATION CEILING SPACE SYMBOL DESCRIPTION WALL CAPS SHALL BE PROVIDED WITH BACKDRAFT DAMPER. REMOTE DUCT SMOKE DETECTOR X W FAN TYPE CLG. BLOWER INLINE FAN 8. PROVIDE METAL ROUND FITTINGS WITH SCOOP AT ALL FLEXIBLE DUCT CONNECTION SUPPLY DUCT (� C To SUPPLY DUCT. TOTAL AIR, CFM 50 70 FIRE DAMPER(S) - X . DRIVE TYPE DIRECT DIRECT RETURN/EXHAUST DUCT W o 9. TEST AND BALANCE: AN INDEPENDENT CONTRACTOR SHALL TEST AND BALANCE ALL yy x VENTILATION AND AIR CONDITIONING SYSTEMS. SUBMIT FOUR COPIES OF TEST AND FAN WHEEL TYPE CENTRIFUGAL CENTRIFUGAL �W�1JW�UJJI FLEXIBLE DUCT SMOKE DAMPER(S) - X E-+ BALANCE REPORT TO OWNER FOR APPROVAL FAN TIP SPEED, FPM MAX. --- --- to E ELBOW W/ TURNING VALVES FIRE RATED ENCLOSURE - X W a0 O 10. CONTROLS: AIR CONDITIONING UNITS SHALL BE STARTED AND STOPPED THRU FAN SPEED, RPM ___ 950 Z 00 0 INDIVIDUAL THERMOSTAT. INDIVIDUAL THERMOSTATS SHALL START/STOP SUPPLY Q TOTAL STATIC PRESSURE, IN OF W.C. 0.10" 0.375" FIRE RATED ROOF/FLOOR FANS AND ACTIVATE COOLING/HEATING SYSTEMS AS SELECTED. 4 REF. S&L REFRIGERANT SUCTION CEILING ASSEMBLY - X co FAN MOTOR (AMPS) 0.6 0.62 & LIQUID LINES 11. MECHANICAL PLANS IN GENERAL, ARE DIAGRAMMATIC IN NATURE, AND ARE TO BE READ IN CONJUCTION WITH ARCH. PLUMBING, ELECTRICAL AND STRUCTURAL PLANS AND SHALL FAN MOTOR STARTER TYPE WALL SWITCH WALL SWITCH FIRE STOPPING BE CONSIDERED AS ONE SET OF DOCUMENTS. DUCT AND PIPING OFFSETS, BENDS STARTER FURNISHED BY MC MC EF CEILING EXHAUST FAN - X AND TRANSITIONS WILL BE REQUIRED TO PROVIDE AND INSTALL A COMPLETE FUNCTIONAL EXHAUST REGISTER SMOKE CONTROL X SYSTEM AND SHALL BE PROVIDED BY THE CONTRACTOR AT NO ADDITIONAL COST TO ELECTRICAL SERVICE 120-1-60 120-1-60 - THE OWNER. UNIT DIMENSIONS WXLXH (IN) 14 X 10 X 9 14 X 11 X 11 12. CONTRACTOR SHALL VERIFY JOB CONDITIONS PRIOR TO ORDERING, FABRICATION OR SONES 1.0 1.3 T COOLING THERMOSTAT E/ INSTALLATION OF MATERIALS OR EQUIPMENT. NOTIFY ARCHITECT/ENGINEER OF ANY O CONFLICTS BEFORE FABRICATION. DESIGN MANUFACTURER NUTONE GREENHECK A X B X: AIR DEVICE TYPE MODEL NUMBER QT-50 CSP-A110 # Q # CFM SERVICE SWITCH YES YES AXB: NECK SIZE SMOKE DETECTOR (U.L APPROVED) NO NO SA SUPPLY AIR FIRE DAMPER --- --- RA RETURN AIR w CONSTRUCTION ALUM/PLASTIC ALUM/STEEL CU CONDENSING UNIT Ix o BACKDRAFT DAMPER YES YES N CFM w BIRDSCREEN NO NO CUBIC FEET PER MINUTE U AHU AIR HANDLING UNIT .0 a SOLID STATE SPEED CONTROL NO NO THERMOSTAT CONTROL NO NO FACTORY FABRICATED CURB NO NO FILTER AND FILTER FRAME NO NO � <<<< O LL- c+) 6 O Q o T Q CV cu T � rn gldyiD! � •rl � V JOB# C I 3i, c_ sheet no. A "Ii ROiJnguez,;"" �. Lice a Nu%be6 B©2 6 C . ' � CA.262591r � a � , °� � IBC MECHANICAL SCHEDULE � �� � ����� �� Gables International Plaza i 2655 Le Jeune Road,Suite 902 `7• `''° Engineering 4esign: Slgflatu + % _ SCALE:N.T.S Coral Gables,Florida 33134 >Mechanical >Electrcal ,' ' M - 3 Phone>305 444 9809 >Plumbing >Fire Protection Date +,,� Fax >305 444 9827 vvvvvv.arpe-eng.com ++i 3 OF 3