6835 SW 67 ST EB-09-019-030 M L_ 01 M I I to CIO m C M ei go di O f ----i C.0 0 O �f7 M �! SECURE WIRE a STRUCTURE OF FLOOR ABOVE SCREWS FASTENE LO TRANSITION AS REQUIRED ELBOW AHU CONNECTION O co c SU AIR TO S/A PLENUM CT PER SMACNA O O & DECK. CEILING F.G.PAG#2.14"DETAIL". WOOD JOIS CORNER ANG , � Q; •B #10"X1 1/4-SHEET METAL SCREWS 12" HANGER WIRE X TURNING VAN O. MIN. 2 12 GAUGE (MIN 4---- PER SIDE. 10"0 MAX. UNIT WALL F/C UNIT 4 MIN. ALL MECHANICAL 10 AROUNE FASTENING AT SHEET METAL CHANNEL DUCT • REFRIGERANT PIPES CONNECTION TO SUSPENDED CEILING �Ca FROM COND. UNIT AHU. (SEE ARCH. DRAWINGS) DRAIN DISCONNECTED °m SWITCH NEOPRENE PADS FAN SECTION DUCT HANGER DETAIL 03 METAL SHELVE COIL SECTION N.T.S. CHANNEL STRAP & SADDLE HANG ALL DUCT PER SMACNA STANDARDS TYPICAL OF 2 I SWITCH.FLOAT HANGING SWITCH. FLOAT GALVANIZED AUXILIARY DRAIN - SWITCH SHALL PAN WITH FLOAT SWITCH STOP FAN COIL (WATER LEVEL DETECTION UNIT IF DEVICE) WIRED TO SHUT INDICATED. HVAC DUCT DETAILS DOWN AHU. NOT TO SCALE PAN SHALL BE MIN. 1.5" INTEGRATED DEEP AND BE AT LEAST 3" WHOLE HOUSE x, : NO COMBUSTIBLES ALLO NOTE M LARGER THAN THE UNIT ON IN A/C CLOSET. AIR CLEANER t>a 0 v ALL DIRECTIONS. MAIN DUCT 0�°� �4-1 k 0 FLOOR �aQ AIR SPLITTER DAMPER b � UQ0 ao RN :a p. CLINCH EDGE 0 m M v ovi ui -=.�•-=::•.:::.... .... .... ....�•-•.:•..,:•..,:•...:.�:•..,:•..,.�.-.:•..,;-..,: PLENUM • . - . . ,•..,:•..,: •- :-..:•-::�':: �::�:::.:::::..::::::: :::::a::=:::.:::�::•.:::-..::-.:::•.:::_•-=.. ' .- ., c� �y 'goy 'oo b o a�i 0 00 0 d'iy b �•fr 04 0 BRANCH DUC z� �oaoi•d ° � NOTE: •� m+�•� ,a ,� m o d 1. PROVIDE MINIMUM 4" SERVICE/ MAINTENANCE AREA AROUND AIR m >a M DIRECTION OF gip,,U 0 0 as HANDLING UNIT. AIRFLOW o � � x 2. PROVIDE FLOAT SWITCH IN DRAINPAN WIRED TO SHUT DOWST! AC SPACER REQ'D ON INSULATED DUCT 0 o o ;",a o UNIT IN CASE OF CONDENSATE STOPPAGE. AS PER FBC 307.2.3. E-4 0 :r4 Q a SET SCREW a m GALV. STEEL ROD FAN COIL UNIT MOUNTING DETAIL N.T.S. TYPICAL DUCT TAP—OFF A N.T.S. PERFORATED CAP O CLEAN OUT " V SUPPORT FROM w STEEL HANGER STRAP UNDERSIDE OF DRAIN PAN (5' O.C.) STRUCTURE. 18' MIN PITCH DOWN SUPPORT STRAP (SUPPORT FROM TOWARD DRAIN AIR DUCT (SEE PLAN VIEW) STRUCTURE) CLEAN OUT LOW FRICTION LOSS SUPLY OR RETURN AIR PLENUM BRANCH TAKE-OFF FITTING SUPPORT BRACE 16 ON CENTER METAL ROUND FITTING 2' MIN QUADRANT OPERATOR TO BE. OUTSIDE INSULATION PROVIDE INSULATION GUARD DRAIN LINE SHALL BE AT LEAST THE WHERE NECESSARY SAME SIZE AS THE NIPPLE ON THE AIR FLOW DRAIN PAN SEAL JOINT W/ DUCT SEALER AND 6' MAX. Ic TAPE DUCT rA .3" MIN CLAMP TYPICAL CONDENSATE DRAIN TRAP AIR FLOW SPIN-IN TAP CEILING N.T.S. INSULATE TOP INSULATED FLEX. DUCT CT-480 OF DIFFUSER. AND OF SAME SIZE o AS HANGER STRAP (3)#14 SHEET METAL SEAL JOINT WITH DUCT NOTES: 1. REFER TO ARCH. FOR FRAMING SCREWS TO C.U. SEALER AND TAPE 2. SIDE DISCHARGE LINEAR BAR DIFFUSER MOUNTING PROCEDURE IS THE SAME BUT WITH AIR OUTLET FACING VERTICAL FACE A/C UNITHOUSING 1/2" HILTI SLEEVE OF SORT. ANCHORS (3)PER SIDE _ 212 X2 X3/ 21 rl� SECTION LINEAR BAR DIFFUSER INSULATED PAD DIFFUSER W/ OPPOSED BLADE DAMPER W 1-1/4" X12", 1$ N.T.S. A �!� • � GAUGE GALVN. METAL ADAPTOR ROUND TO SQUARE STRAP. ONE ON EVERY IF REQUIRE W o CORNER OF 08 og °$: CONDENSER. co to FLEXIBLE DUCT CONNECTION DETAIL w 0 0 MOUNTING DETAIL ® BASE N.T.S. co U) W/TURN BUCKLES 1/8" WIRE PROVIDE ANTI-THEFT 1) 500 6" TOILET EXHAUST DUCT ANCHORED TO SLAB W/18 LBS. BOLT WITHIN UNIT CASING (SHEETMETAL THERMOFIN TO SLAB. / � GAUGE TFK SCREWS TYPICAL ROOF CAP r� POWER AND CONTROL CONNECTIONS VIBRATION HANGER SPRING TYPE CONDENSIN W/NEOPRENE ISOLATOR UNIT 6" MIN. GRADE if 321 1 3/8" THREADED 1 4 6" MIN. RODS • :. 1\-4" MIN. VIBRATION JOIST 3/8" ALL ISOLATOR o CONCRETE BASE THREAD W/ 6" X 6"- +� LIQUID LINE WITH 12" DIAMETER 10/10 W.W.F. `ii i� OUT INSULATION CONCRETE Q ° VIBRATION ISOLATOR cP n n ° A ISOLATOR Jill PERFORATED AL ° o ° O 2" X 2" X 3/4' "';; DRAINAGE OR CLAY ° ° DUCT / "I PIPE WITHOUT COVER ° ° ° INSULATED PAD a , � „ ��.�.` 4'0 SCH. 40 FILLED WITH 3/4 ° ° DUCT CEILING BDD 6" M P.V.C. PIPE CRUSHED ROCK o ° 2" NU HUNG WRITE O ° Q°° CONDENSATE FAN GRILLE � SUCTION LINE WITH 3/ DRAIN LINE �• E� ARMAFLER INSULATION NOTE: CONDENSER SHALL BE 24" ° ° °° 221 X UT. �� A/C INSTALLED OSEToVE FLOOD LEVEL I o o ° FROM BUILDING NOTES: 1.- PROVIDE BACKDRAFT DAMPER W/ BIRDSCREEN N AND VAPOR BARRIER °°°o SEE PLAN I 0 IJ 2.- FLASH & SEAL WALL AND ROOF CAP � ° NOTE: CONCRETE CREWS SHALL BE RATED CEILING � BACKDRAFT 3.- PROVIDE INTERNAL ISOLATION AND SOUND INSULATION 4.- SUPPORT FAN FROM STRUCTURE <<< DAMPER o � ch 0 00 LBS. MIN. PULL-OUT CAPACITY. 1 U_ aC T DRY WELL DETAIL TOILET INLINE EXHAUST DETAIL CABINET EXHAUST FAN DETAIL r o N.T.S. N.T.S. N ONDENSING UNIT MOUNTING DETAIL r N.T.S. .T.S. O 'ZS 0 cu W co lici rn t � ,10134_ 9-040 s Sheet 110. —� Amarilig'Rddnguez,P . Nu 111 �r License �NI ` License � CA 26359 T ` inn STATEGF M E C HAH I CAL DETAILS Gables Intemational Plaza 2655 Le Jeune Road,Suite 902 Engineering Design: Signa_ 70 p 10 .• M - 2 Coral Gables,Florida 33134 >Mechanical >Bectrical •' . C' ALE :N.T.S Phone>305 444 9809 >Plumbing >Rre Protection Date Fax >305 444 9827 vvww.arpe-eng.com "'`�° ' ' ` � 2 of 3