08-40-225LIGHTING FIXTURE SCHEDULE Type Luminaire Description Manufacturer and Catalog Number Volts Lgmp InfqrmationMounting ��� W.. V • ' U ` ' Finish Remarks No. Type /Base/Color/CRI A 4' SURFACE FLUORESCENT KENALL MLHA8 48 -R -MW -PP -2 -32 -ED -1 -DV DUAL 2 32W T-8 MED. BI -PIN 4100082 CRI SURFACE WHITE UL LISTED FOR WET LOCATION B ELEVATOR PIT LIGHT HUBBELL ZVW-100TW 120 1 10OW A-19 FROSTED WALL WHITE UL LISTED FOR WET LOCATION C 4' ENCLOSED FLUORESCENT COLUMBIA UNIV 2 32W T-8 MED. BI -PIN SURFACE WHITE UL LISTED FOR WET LOCATION D 4' FLUORESCENT STRIP TEMPORARY COLUMBIA CS4-232-E-U-CSW UNIV 2 32W 1-8 MED. BI -PIN 41000 82 CRI SURFACE WHITE E EMERGENCY LIGHT COMPASS SEU2 DUAL 2 5.0 HALOGEN INCLUDED WALL 7 AFF WHITE F EXTERIOR DECORATIVE LIGHT KIM 120 1 32W TT 4P GX24q-3 WALL 7 AFF WHITE UL LISTED FOR WET LOCATION G 5" PL DOWNLIGHT PEACHTREE PEF-52 6-C- 120 120 1 26W TT 4P GX24q-3 100K A9 CRI RECESSED CLEAR ALUMINUM H 4' LOW PROFILE WEATHER-PROOF FLUORESCENT THE LIGHT EDGE MON/154/120/WB/PEND 120 1 54W T-5/HO MINI BI -PIN 41000 82 CRI PENDANT WHITE EVEN WITH BOTTOM OF TEES AND/OR XPOSED B MS H1 4 LOW PROFILE WEATHER-PROOF FLUORESCENT WITH BATT PACK THE LIGHT EDGE MON 154 120 WB EM PEND 120 1 54W T'-5/HO MINI BI -PIN 41000 82 CRI PENDANT WHITE EVEN WITH BOTTOM OF TEES AND/OR EXPOSED BEAMS H2 HID GARAGE LUMINAIRE KIM 120 1 10OW PMH ED -17 MED. BASE PENDANT OR WHITE WEATHER-PROOF IP66 RATED H3 HID GARAGE LUMINAIRE KIM PGL53 100PMH120 A PW2 120 1 10OW PMH ED -17 MED. BASE PENDANT OR SURFACE WHITE WEATHER-PROOF IP66 RATED THRU POWERCLONE INVERTER I SMALL DECORATIVE FLOOD LIGHT KIM CFL1 Z42PL120 CC -P J -27N 120 1 42W TT 4P GX24q-3 41OOK 82 CRI SURFACE WITH J- 7N COLOR BY ARCHITECT UL LISTED FOR WET LOCATION J 8" PL PENDANT CYLINDER PEACHTREE - - 20 -WL -PND -XX 120 2 32W TT 4P GX24q-3 410Q 92 PENDANT WHITE K CONCEALED EMERGENCY LIGHT WITH REMOTE EMERG. PANELS SIGNTEX CVRE-50-24-DP-SM 120/12 2 -CRI 50W MR -16 INCLUDED PENDANT ON SURFACE BOX WHITE EVEN WITH BOTTOM OF TEES AND/OR EXPOSED L HID CUT-OFF DECORATIVE WALL PACK KIM WD14x4 75MH120 WH -P HS 120 1 175W MH ED -17 MED. BASE 38000 65 CRI WALL ABOVE 12 ON SIDE OF MLDG WHITE UL LISTED FOR WET LOCATION M 2X4 TROFFER COLUMBIA UNIV 232W T-8 MED. BI -PIN LAY -IN WHITE N 5" PL DOWNLIGHT PEACHTREE PFF532-C-120 120 1 32W TT 4P GX24q-3 41nm/A9 CRI RECESSED CLEAR ALUMINUM 0 4' LOW PROFILE WEATHER-PROOF FLUORESCENT THE LIGHT EDGE MON 154 XX WB EM 120 1 54W T-6/HO MINI BI -PIN 41000 82 CRI SURFACE WHITE 1250 LUMENS BATTERY PACK P 41" FLUORESCENT VANITY LIGHT VISA CB6440-2F39-120-BA 120 2 39W T5 21311 41000 82 CRI 6" ABOVE MIRROR BRUSHED ALUMINUM Q AIRCRAFT WARNING LIGHT TWR 120 2116A-21/TS SURFACE GREY FAA APPROVED R PL WALL PACK KENALL H612EM-C-MW-32P-2-DV DUAL 2 32W TT 4P GX24q-3 41000 82 CRI SURFACE WHITE S LOW WATTAGE HID CUT-OFF WALL PACK KENALL FN15D-IV-8G-MB-70M-1 S 120 1 70W MH ED -17 MED. BASE 42000 82 CRI WALL +10 AFF ON BLDG WALL WHITE UL LISTED FRO WET LOCATION T FLOURESCENT STEP LIGHT WITH INTF('RAI FMERG. BATTERY PACK COLE 2156-E2156-2 J -W -TP -EM -XXX 120 2 13W TT 2P GX23 PH R2 CRI WALL 3 AFF COLOR BY ARCHITECT - UL LISTED FOR WET LOCATION X THERMOPLASTIC LED EXIT SIGN ___4100 COMPASS DUAL NIA RED LED'S UNIVERSAL WHITE SINGLE AND DOUBLE FACE EXIT SIGN X1 _.._. WP LED EXIT SIGN WITH EMERG. BATTER COLE 120 NIA RED LED'S LNl(11 UDFD TOP WHITE UL LISTED FOR WET LOCATION NEC 300-19 (b) SUPPORT BUSHING, LOCATED AT THE TOP OF A VERTICAL CONDUIT AT CABINET OR PULL NOS, PREVENTS THE WEIGHT OF THE CONDUCTORS FROM DAMAGING THE INSULATION OR RACING A STRAIN ON TERMINATION POINTS. BUSHING SUPPORT DETAIL N.T.S. CLAMP RISER CLAMP FEEDER SUPPORT 3/16"X1-1/2" GALVANIZED STEEL SECURE CLAMP WITH TWO 1/2-0 X 1/2- LONG BOLTS LOCKWASHER, AND NUT FEEDER/RISER CONDUIT FINISHED FLOOR FLOOR:CONCRETE FLOOR % �'.:' i' �' • ' '' SLAB DIMENSION VARIES METAL FLOOR I FILL SPACE BETWEEN SLEEVE SLEEVE h CONDUIT WITH SEALING COMPOUND FOR FULL DEPTH FEEDER CONDUIT SLEEVE DETAIL N.T.S. ELEVATOR ELECTRICAL NOTES 1. PROVIDE ELEVATOR DISCONNECT INSIDE ELEVATOR MACHINE ROOM WITH TIME DELAY FUSES (RK5) WITH REJECTION CLIPS. FUSES ARE TO BE SIZED AS REQUIRED BY ELEVATOR COMPANY SHOP DRAWINGS. (NEC 620-51). 2. PROVIDE A DEDICATED 120V, 20A, BRANCH CIRCUIT PER NEC 620-22 FOR ELEVATOR CAR LIGHTS WITH A DISCONNECTING MEANS, (MUST RE LOCKABLE IN THE OPEN POSITION AND WIRED TO ELEVATOR CONTROLLER). 3. LIGHT FIXTURE INSIDE ELEVATOR MACHINE ROOM SHALL BE LENSED TYPE; OR IF INDUSTRIAL TYPE, SHALL BE PROVIDE WITH WIRE CARDS AND TUBE GARD. 4. PROVIDE A 20A, 125V, GFI RECEPTACLE IN ELEVATOR MACHINE ROOM AND PIT. 5. PROVIDE A DEDICATED TELEPHONE LINE TO ELEVATOR CONTROLLER. (ONE DEDICATE LINE PER ELEVATOR). 6. ELEVATOR CAB(S) SHALL BE PROVIDED WITH A TELEPHONE OR A MEANS OF TWO-WAY COMMUNICATION. 7. PROVIDE TWO VAPOR TIGHT LIGHT FIXTURES CONTROLLED BY A SWITCH INSIDE EACH ELEVATOR PIT. 8. WHEN A HYDRAULIC ELEVATOR HAS PROVISIONS FOR LOWERING BY BATTERY, THE MACHINE ROOM DISCONNECT, WHILE IN THE "OFF' POSITION (OPEN), MUST PREVENT THE ELEVATOR FROM LOWERING UNDER BATTERY POWER TO SHUT DOWN THE BATTERY LOWERING FEATURE WITH THE ELEVATOR DISCONNECT SWITCH, THE CONTRACTOR SHALL PROVIDE AN AUXILIARY SET OF CONTACTS IN THAT SWITCH AND A PAIR OF #16 WIRES TO THE ELEVATOR CONTROLLER TO DISABLE THE BATTERY LOWERING FUNCTION. THE BATTERY LOWERING FUNCTION SHALL ALSO BE DISABLED UNDER SHUNT TRIP OPERATION, SEE BELOW. 9. WHEN A BUILDING IS PROTECTED BY A WET PIPE SPRINKLER SYSTEM AND SPRINKLER HEADS ARE INSTALLED IN THE ELEVATOR SHAFT, THE ELEVATOR PIT, AND THE ELEVATOR MACHINE ROOM. PROVIDE FIXED TEMPERATURE HEAT DETECTOR NEXT TO EACH SPRINKLER HEAD ON THE TOP OF THE SHAFT, SIDE OF THE ELEVATOR PIT, AND ELEVATOR MACHINE ROOM. HEAT DETECTOR TEMPERATURE SHALL BE LOWER THAN SPRINKLER HEAD TEMPERATURE, VERIFY WITH FIRE PROTECTION CONTRACTOR PRIOR TO ORDERING. THESE HEAT DETECTORS ARE NOT CONNECTED TO THE BUILDING'S FIRE ALARM SYSTEM, BUT ARE USED EXCLUSIVELY FOR TIRING OF THE ELEVATOR SERVICE DISCONNECT AT THE MAIN ELECTRICAL ROOM. PROVIDE SHUNT TRIP BREAKER AT EACH ELEVATOR SERVICE DISCONNECT. IF ELEVATOR IS EQUIPPED WITH A BATTERY LOWERING FEATURE, AN ADDITIONAL SET OF AUXILIARY CONTACTS MUST BE PROVIDED AT THE HEAT DETECTOR AND 2#16 WIRES SHALL BE PROVIDED TO THE ELEVATOR CONTROLLER TO DISABLE THE BATTERY LOWERING FEATURE. IN LIEU OF ADDITIONAL CONTACTS AT THE HEAT DETECTORS, THE CONTRACTOR SHALL PROVIDE ADDITIONAL WIRING FROM THE SHUNT TRIP BREAKER TO THE ELEVATOR CONTROLLER TO DISABLE THE BATTERY LOWERING FEATURE. THIS WIRING WILL BE INSTALLED IN SERIES WITH THE AUXILIARY DISCONNEf SWITCH CONTACTS. THE DRY CONTACTS CONTAINED IN THE AUXILIARY SWITCHES ARE CLOSED WHEN EITHER THE SHUNT TRIP OR DISCONNECT IS IN THE "ON" POSITION AND WILL BE OPEN WHEN THE DISCONNECT IS OPENED OR SHUNT TRIP/HEAT DETECTOR ACTIVATED. ELECTRICAL SYMBOL LEGEND FLUORESCENT LIGHT FIXTURE, 'Ef' EMERGENCY LIGHT W/BATTERY 1�0 WALL LIGHT HM i WALL OR CEILING MOUNTED EXIT LIGHT FIXTURE WITH BATTERY BACK-UP. ARROWS, NUMBER OF FACES AND MOUNTING AS REQUIRED TO INDICATE A CLEAN PATH TO EXIT. $ 120/277 V., 20 AMP., SINGLE POLE LIGHT SWITCH. $3 120/277V., 20 AMP., THREE WAY SWITCH. $M MANUAL MOTOR STARTER. m ELECTRICAL PANEL o -I FUSED DISCONNECT SWITCH SIZED PER EQUIPMENT NAMEPLATE. ® MAGNETIC MOTOR STARTER, PROVIDED BY MECHANICAL CONTRACTOR, INSTALLED BY ELECTRICAL CONTRACTOR. 4 ELECTRIC MOTOR. .IV\r EQUIPMENT CONNECTION WITH FLEXIBLE CONDUIT. 20A., 120 V., QUADRUPLEX RECEPTACLE, TWO DUPLEX IN TWO BOX. 18" A.F.F. 20 A., 120., V., DUPLEX RECEPTACLE, GROUNDING ME, U.Q.N. MOUNTED 11" A.F.F. CEILING OR WALL MOUNTED JUNCTION BOX. TELEPHONE OUTLET AT 11" A..F.F. (4" SQ. J. BOX) ' HOME RUN TO PANEL ACCESSIBLE JUNCTION BRANCH CIRCUIT FINISH SLAB BOX f- J GRID SUPPORT 3/8- FLEXIBLE CONDUIT. NEXT TO FIXTURE MAX 6FT. AS PER NEC 3411aHTING FIXTURE J �-- FINISHED CEILING RECESSED FLORESCENT LT. FIXTURE CONNECTION DETAIL N.T.S. NOTES: 1.- ALL RECESSED LIGHT FIXTURES ARE TO BE CONNECTED AS DETAILED. 2.- ALL JUNCTION BOXES ARE TO BE READILY ACCESIBLE. 3.- PROVIDE FIRE PROOF TENT AS REQUIRED TO KEEP UL CEILING RATING. ADDRESSABLE FIRE ALARM SYSTEM NOTES 1. FURNISH AND INSTALL ALL LABOR, MATERIAL, AND EQUIPMENT NECESSARY FOR AND DEVICES NEW ADDRESSABLE FIRE ALARM PANEL AS SPECIFIED HEREIN AND AS SHOWN ON THE ELECTRICAL DRAWINGS. THIS SYSTEM SHALL BE ZONED, ELECTRICALLY SUPERVISED, HAVE CLOSED CIRCUITS, AND SHALL BE CONNECTED, TESTED AND LEFT IN FIRST CLASS OPERATING CONDITION. 2. FIRE ALARM SYSTEM SHALL BE U.L LISTED NFPA 72 APPROVED. 3. UPON ACTIVATION OF FIRE ALARM SYSTEM BY MANUAL STATION, THE FOLLOWING SHALL TAKE PLACE: A ENERGIZE ALARM SIGNALING DEVICES I SOUND AUDIBLE ALARMS AND FLASH VISUAL SIGNALS C ALERT LOCAL FIRE DEPARTMENT OR PROPRIETARY SYSTEM D CAUSE ZONE IN ALARM TO BE DISPLAYED ON THE ANNUNCIATOR 4. ALL WIRING AND CONDUIT SIZE SHALL BE IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATION, AND REQUIREMENTS OF NEC, LOCAL CODES AND NFPA IN NO CASE, SHALL THE WIRING ME SMALLER THAN #16 5. ALL CONDUCTORS SHALL BE COOPER AND SHALL BE SIZED FOR A MAXIMUM LOSS OF Id1. MINIMUM WIRE SIZE SHALL BE AS REQUIRED BY MANUFACTURER IN NO CASE. SHALL THE WIRING BE SMALLER THAN J16 F.P.L. CU IN. 3/4 CONDUIT 6. QUANTITY OF WIRES PER DEVICES SHALL BE AS REQUIRED NY MANUFACTURER. 7. SYSTEM TO BE POWER LIMITED. 8. VISUAL ALARMS PER ANSI A117.1,4.26, FMC AND ADA 9. CONDUIT FOR FIRE ALARM SHALL BE METALLIC TYPE. 10. CONTRACTOR IS RESPONSIBLE FOR PROVIDING SIGNED A SEALED FIRE ALARM PERMIT DRAWINGS BY A FLORIDA REGISTERED ENGINEER. JMM CONSULTING ENGINEERS LLC IS NOT RESPONSIBLE FOR F/A PERMIT DWGS. 11. COORDINATE EXACT LOCATION OF ALL TAMPER k FROM SWITCHES WITH SPRINKLERS DRAWINGS. ALL TAMPER is FROM SWITCHES SHALL ME MONITORED BY FACP. 12. ACTIVATION OF A SMOKE DETECTOR IN ANY ELEVATOR LOBBY OR ASSOCIATED ELEVATOR MACHINE ROOM, OTHER THAN AT THE DESIGNATED LEVEL, SHALL CAUSE ALL CARS THAT SERVE THAT LOBBY TO RETURN NON-STOP TO THE DESIGNATED LEVEL THE OPERATION SHALL CONFORM TO THE REQUIREMENTS OF RULE 211.3A OF ASME/ANSI A17.1-1987 AS ADOPTED BY CHAPTER 4A-47 OF THE DEPARTMENT OF INSURANCE, STATE FIRE MARSHAL. NO DEVICE, OTHER THAN PHASE I SWITCH (RULE 211.3A) OR THE DETECTORS IN THE ELEVATOR LOBBY OR ASSOCIATED MACHINE ROOM SHALL INITIATE PHASE I OPERATION. IF THE SMOKE DETECTOR AT THE DESIGNATED LEVEL IS ACTIVATED, THE CARS SHALL RETURN TO ALERNATE LEVEL APPROVED BY THE ENFORCING AUTHORITY, UNLESS THE PHASE I SWITCH (RULE 211.3A) IS IN THE "ON" POSITION. SMOKE DETECTOR ACTIVATION SHALL ONLY BE RESET MANUALLY. FIRE ALARM LEGEND E ]ETC., NOTIFIER NFS-640 ADDRESSABLE FIRE ALARM PANEL PROVIDED DIALER, POWER SUPPLIES, ACCESORIES AND RELAYS AS REQUIRED. AS REQUIRED. H< ADA HORN/STROBE SYSTEM SENSOR jP21R (SEE FLOOR PLAN FOR CANDELA) 5D PHOTOELECTRIC SMOKE DETECTOR NOTIFIER #FSP -151 W/BASE 171OLID sD SMOKE DUCT DETECTOR NOTIFIER #FSD-751PL WITH SAMPLING TUBES HD HEAT DETECTOR NOTIFIER #FST -851 W/RASE 171OLP R PULL STATION NOTIFIER #NIG-12LX ADA STORME LIGHT SYSTEM SENSOR SR (SEE FLOOR PLAN FOR CANDELA) (WP) UL LABELED WEATHER PROOF REMOTE ANNUNCIATOR NOTIFIER LCD80 WQ-I ELEVATOR WARNING LIGHT 'DO NOT USE" 10. ALL SHALL BE THWN. 11. ALL CONDUCTORS SHALL BE COPPER RUN IN METALLIC CONDUIT. 12. ALL CONDUCTORS SHALL BE RUN IN CONDUIT METALLIC TYPE). IF PVC SCHEDULE 40 IS USED FOR UNDERGROUND FEEDERS ONLY, AN EQUIPMENT GROUND CONDUCTOR SIZED IN ACCORDANCE WITH N.E.C. 250-122 MUST 8E INSTALLED AND CONDUIT SIZE INCREASED AS REQUIRED. 13, ALL MATERIALS SHALL BE U.L. APPROVED. 14. NEW TYPEWRITTEN PANEL TALLY SHALL BE FURNISHED AFTER JOB IS COMPLETED. 15. ALL BRANCH CIRCUITS SHALL BE PROPERLY PHASE BALANCED. 111. ALL NON POWER RELATED WIRING I N CEILING AIR CONDITIONING PLENUM RUNNING WITHOUT CONDUIT SHALL RE TEFLON COATED CLASSIFIED FOR USE IN PLENUMS. 17. PROVIDE TRAPEZE HANGER AS ASSEMBLE FOR PLENUM COMMUNICATION CABLE WITH 3/8' DIAMETER. THREADED ROD AND CHANNEL ASSEMBLY TO SUPPORT CABLE BUNDLES EVERY 4 FTO.C. (MAXIMUM CABLES SHALL NOT LIE ON TOP OF CEILING TILE OR LUMINARIES). 11. LIGHT SWITCHES OPERATING CIRCUIT OTHER THAN 120 V SHALL NOT RE GANGED IN SAME BOX UNLESS SWITCHES ARE CONNECTED TO SAME CIRCUIT. 19. ALL BRANCH CIRCUITS TO HAVE A GREEN EQUIPMENT GROUNDING CONDUCTOR SIZED AS PER N.E.C. 250.122. 20. ALL EMPTY CONDUITS TO ME PROVIDED WITH NYLON PULL STRINGS. 21. FUSES SHALL BE DUAL ELEMENT, TIME DELAY TYPE UNLESS OTHERWISE NOTED. 22. A/C EQUIPMENT WIRING, BREAKER AND FUSE SIZES ARE BASED ON A/C EQUIPMENT SPECIFIED ON CONTRACT DRAWING, CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL WIRING, BREAKER AND FUSES SIZES IN ACCORDANCE WITH A/C EQUIPMENT NAMEPLATE REQUIREMENTS IF DIFFERENT FROM THAT SPECIFIED ON DRAWINGS, AS WELL AS ANY FEEDER CHANGES BEING AFFECTED BY THIS CHANGE CONTRACTOR SHALL MAKE ABOVE MENTIONED CHANGES AT NO EXTRA COST. 23. CONTACTOR SHALL COORDINATE ALL HIS WORK WITH OTHER TRADES IN ORDER TO FURNISH AND INSTALL ALL CONTROL WIRING AND RACEWAYS, ALL POWER CONTROL CIRCUIT WIRING AND RACEWAY AS SHOWN ON THE AIR CONDITIONING DRAWING OR SPECIFICATIONS. IF AIR CONDITIONG DRAWING REFER TO MANUFACTURER ALL REQUIREMENT AND INCLUDE ALL RELATED WORK IN HAS CONTACT. 24. ALL LUMINARIES SHALL BE PROPERLY SUPPORTED IN ACCORDANCE WITH THE CEILING SYSTEM MANUFACTURER RECOMMENDATIONS AND LOCAL CODE REQUIREMENTS. 25. RISERS ARE DIAGRAMMATIC ONLY, THEY DO NOT SHOW EVERY BEND REQUIRED FOR THE INSTALLATION. 26. THIS DRAWING IS A GUIDE FOR THE ELECTRICAL INSTALLTION, THE ELECTRICAL CONTRACTOR IS RESPONSIBLE TO PROVIDE A FUNCTIONING SYSTEM. 27. ALL CABLES SHALL ME RUN WITHOUT SPLICES EXCEPT IF OTHERWISE INDICATED. 28. ALL PULL AND JUNCTION BOXES SHAL IE ACCESSIBLE AT ALL TIMES. 29. EXACT POINT AND METHODS OF CONNECTION SHALL BE DETERMINED IN FIELD. 30. ALL WORK SHALL NE DONE IN A NEAT AND WORKMANLIKE MANNER. 31. BRANCH CIRCUIT BREAKERS SHALL BE OF THE BOU N TYPE. PLUG IN CIRCUIT BREAKERS WILL NOT BE ACCEPTED. 32. SUMMIT DETAILED LAYOUT OF ALL ELECTRICAL ROOMS WITH EQUIPMENT REQUIRING ELECTRICAL SERVICE, LAYOUT SHALL SHOW PROPOSED LOCATION OF ELECTRICAL SERVICE ITEMS SUCH AS DISCONNECTS, RELAY, PANELBOARDS, ETC. AND DIMENSIONS SHOWING CODE CLEARANCES TO ADJACENT SURFACES, 33. ALL ROUGH IN DIMENSIONS ARE TO CENTER LINE OF DEVICE UNLESS OTHERWISE NOTED. 34, ALL PULL BOXES, HAND HOLES AND MAN HOLES TO HAVE COVER PLATE BOLTED TO FRAME AND BONDED TO THE EQUIPMENT GROUND SYSTEM. 35. CONTRACTOR SHALL INCLUDE IN HIS BID ALL COST RELATED TO THE WIND LOAD COMPLIANCE, THE CERTIFICATION OF THE EXTERIOR POLE/LUMINARY ASSEMBLIES BY A STRUCTURAL ENGINEER. 36. ALL CONDUCTOR SPLICES IN EXTERIOR LOCATED JUNCTION / PULL BOXES EXPOSED TO THE WEATHER TO ME WEATHER SEALED BY USING AN APPROVED METHOD SUCH AS 3M, SCOTHLOCK CONNECTOR EPDXY SEALING, PACK OR SIMILAR. 37. CONTRACTOR SHALL PROVIDE TEMPORARY PANEL, LIGHTS & OUTLETS THROUGHOUT THE BUILDING DURING COMPLETE CONSTRUCTION (ALL POWER MUST BE MADE TO SATISFY CONSULTANT NEEDS FOR ALL EQUIPMENT.) CI1'Y OF SOUT, !-1 I''S7V+i`.'Ii BUILDING DEPT. ELE:CTril(".AL. ST-CT10i,J APPROVE 3Y: _,_. __. __ DATE: , #26000522 ARCHITECTURE INTERIOR DESIGN PLANNING SEAL RONEY J. MATEU AR 0008220 JMM CONSULTING ENGINEERS, LLC M.E.P. 12651 S DIXIE HIGHWAY, SUITE 209 MIAMI, FLORIDA 33156 M.A. SUAREZ CONSULTING ENGINEERS STRUCTURAL ENGINEERING 4869 SW 75TH AVENUE MIAMI, FLORIDA 33155 PISTORIND & ALAM CONSULTING ENG, INC, CIVIL ENGINEERING 7171 SW 62ND AVENUE, 4TH FLOOR MIAMI, FLORIDA 33143 OXFORD UNIVERSAL 4311 PONCE DE LEON BLVD. CORAL GABLES, FLORIDA 33146 5966 SOUTH DIXIE BUILDING 5966 & 5970 SOUTH DIXIE HIGHWAY MIAMI, FLORIDA 33133 M A TE U ARCH ITECTURE INC. THIS DRAWING 15 THE PROPERTY OF MATEU ARCHITECTURE INC. UNLESS OTHERWISE PROVIDED FOR BY CONTRACT THE CONTENTS OF THIS DRAWING ARE CONFIDENTIAL AND SHALL NOT IE TRANSMITTED TO ANY PARTY EXCEPT AS AUTHORIZED BY THE ARCHITECT/ENGINEERS OF RECORD PHASE -AT. LT1j"Ififfla i FILE NAME: E -204 -DWG PROJECT NO MA0605 DRAWN NY: JMM CHECKED BY: JMM ISSUE DATE. DECEMBER 10, 2007 diH691U�169 SHEET TITLE NOTES & DETAILS SHEET- OF. E-204 19 • M f r V• i i • • • u • r r • G • i y V E •G •Y V • • Y • V Y Y iVu uuV u GENERAL ELECTRICAL NOTES �` • V y • 4,"V ��� W.. V • ' U ` ' `GY • .� • V y V 1. ALL WORK SHALL ME IN ACCORDANCE WITH NATIONAL ELECTRICAL CODE, " " . " • . • G r FLORIDA BUILDING CODE AND OTHER APPLICABLE CODES AND STANDARDS. 2. a) THE DRAWINGS ARE DIAGRAMMATIC AND DO NOT SHOW ALL OFFSETS, BENDS ANQ BOXES REQUIRED TO MAKE A COMPLETE NEAT INSTALLATION IN ACCORDANCE 11` b) N.E.C. WHEN CONFLICTS ARISE IN LOCATIONS WIRING DEVICES, ELECTRICAL EQUIPMENT,' DISCONNECTS, PANELBOARDS, ETC. DUE TO FIELD CONDITION OR IMPROPER FIELDo •+• i v • 4 G COORDINATION CONTRACTOR SHALL BRING IT TO THE A/E'S ATTENTION AND AT NO EXTRA COST RELOCATE, AND OR EXTEND WITHIN A REASONABLE DISTANCE SUCH ITEM WHICH IS IN CONFLICT, THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING LOCATION OF ALL COMPONENTS PRIOR TO ROUGH IN WITH ALL TRADES NO EXTRAS WILL BE ALLOWED FOR FAILURE TO DO SO. 3. THE CONTRACTOR IS RESPONSIBLE FOR EVALUATING FIELD CONDITIONS BY VISITING THE SITE PRIOR TO COMMENCING / BIDDING WORK. 4. THE CONTRACTOR SHALL SATISFACTORILY REPAIR! REPLACE EQUIPMENT OR PART OF STRUCTURE DAMAGED AS A RESULT OF HIS WORK. SURFACES AND FINISHED AREAS SHALL BE RESTORED TO MATCH ADJACENT AREAS. 5. APPROVAL SHALL BE OBTAINED FROM A STRUCTURAL ENGINEER PRIOR TO CUTTING OR DRILLING ANY STRUCTUALSUPPORT MEMBER. G. ALL DEVICE BOXES SHALL ME INSTALLED FLUSH AND CONDUITS RUN CONCEALED IN FINISHED AREAS EXCEPT AS SPECIFICALLY SHOWN/NOTED OTHERWISE. 7. INSTALL POWER AND CONTROL WIRING AND REQUIRED CONTROL COMPONENTS FOR AIR CONDITIONING SYSTEM AS SHOWN/NOTED ON THESE DRAWINGS AND PER OTHER APPLICILE DRAWINGS / INSTRUCTTIONS. SEE AIR CONDITIONING DRAWING. 8. ALL MATERIAL REMOVED SHALL BE SISPQSED OF AS DIRECTED BY OWNER. 9. MINIMUN WIRE SIZE SHALL BE # 12 THHN / THWN UNLESS OTHERWISE NOTED ON PLANS. 10. ALL SHALL BE THWN. 11. ALL CONDUCTORS SHALL BE COPPER RUN IN METALLIC CONDUIT. 12. ALL CONDUCTORS SHALL BE RUN IN CONDUIT METALLIC TYPE). IF PVC SCHEDULE 40 IS USED FOR UNDERGROUND FEEDERS ONLY, AN EQUIPMENT GROUND CONDUCTOR SIZED IN ACCORDANCE WITH N.E.C. 250-122 MUST 8E INSTALLED AND CONDUIT SIZE INCREASED AS REQUIRED. 13, ALL MATERIALS SHALL BE U.L. APPROVED. 14. NEW TYPEWRITTEN PANEL TALLY SHALL BE FURNISHED AFTER JOB IS COMPLETED. 15. ALL BRANCH CIRCUITS SHALL BE PROPERLY PHASE BALANCED. 111. ALL NON POWER RELATED WIRING I N CEILING AIR CONDITIONING PLENUM RUNNING WITHOUT CONDUIT SHALL RE TEFLON COATED CLASSIFIED FOR USE IN PLENUMS. 17. PROVIDE TRAPEZE HANGER AS ASSEMBLE FOR PLENUM COMMUNICATION CABLE WITH 3/8' DIAMETER. THREADED ROD AND CHANNEL ASSEMBLY TO SUPPORT CABLE BUNDLES EVERY 4 FTO.C. (MAXIMUM CABLES SHALL NOT LIE ON TOP OF CEILING TILE OR LUMINARIES). 11. LIGHT SWITCHES OPERATING CIRCUIT OTHER THAN 120 V SHALL NOT RE GANGED IN SAME BOX UNLESS SWITCHES ARE CONNECTED TO SAME CIRCUIT. 19. ALL BRANCH CIRCUITS TO HAVE A GREEN EQUIPMENT GROUNDING CONDUCTOR SIZED AS PER N.E.C. 250.122. 20. ALL EMPTY CONDUITS TO ME PROVIDED WITH NYLON PULL STRINGS. 21. FUSES SHALL BE DUAL ELEMENT, TIME DELAY TYPE UNLESS OTHERWISE NOTED. 22. A/C EQUIPMENT WIRING, BREAKER AND FUSE SIZES ARE BASED ON A/C EQUIPMENT SPECIFIED ON CONTRACT DRAWING, CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL WIRING, BREAKER AND FUSES SIZES IN ACCORDANCE WITH A/C EQUIPMENT NAMEPLATE REQUIREMENTS IF DIFFERENT FROM THAT SPECIFIED ON DRAWINGS, AS WELL AS ANY FEEDER CHANGES BEING AFFECTED BY THIS CHANGE CONTRACTOR SHALL MAKE ABOVE MENTIONED CHANGES AT NO EXTRA COST. 23. CONTACTOR SHALL COORDINATE ALL HIS WORK WITH OTHER TRADES IN ORDER TO FURNISH AND INSTALL ALL CONTROL WIRING AND RACEWAYS, ALL POWER CONTROL CIRCUIT WIRING AND RACEWAY AS SHOWN ON THE AIR CONDITIONING DRAWING OR SPECIFICATIONS. IF AIR CONDITIONG DRAWING REFER TO MANUFACTURER ALL REQUIREMENT AND INCLUDE ALL RELATED WORK IN HAS CONTACT. 24. ALL LUMINARIES SHALL BE PROPERLY SUPPORTED IN ACCORDANCE WITH THE CEILING SYSTEM MANUFACTURER RECOMMENDATIONS AND LOCAL CODE REQUIREMENTS. 25. RISERS ARE DIAGRAMMATIC ONLY, THEY DO NOT SHOW EVERY BEND REQUIRED FOR THE INSTALLATION. 26. THIS DRAWING IS A GUIDE FOR THE ELECTRICAL INSTALLTION, THE ELECTRICAL CONTRACTOR IS RESPONSIBLE TO PROVIDE A FUNCTIONING SYSTEM. 27. ALL CABLES SHALL ME RUN WITHOUT SPLICES EXCEPT IF OTHERWISE INDICATED. 28. ALL PULL AND JUNCTION BOXES SHAL IE ACCESSIBLE AT ALL TIMES. 29. EXACT POINT AND METHODS OF CONNECTION SHALL BE DETERMINED IN FIELD. 30. ALL WORK SHALL NE DONE IN A NEAT AND WORKMANLIKE MANNER. 31. BRANCH CIRCUIT BREAKERS SHALL BE OF THE BOU N TYPE. PLUG IN CIRCUIT BREAKERS WILL NOT BE ACCEPTED. 32. SUMMIT DETAILED LAYOUT OF ALL ELECTRICAL ROOMS WITH EQUIPMENT REQUIRING ELECTRICAL SERVICE, LAYOUT SHALL SHOW PROPOSED LOCATION OF ELECTRICAL SERVICE ITEMS SUCH AS DISCONNECTS, RELAY, PANELBOARDS, ETC. AND DIMENSIONS SHOWING CODE CLEARANCES TO ADJACENT SURFACES, 33. ALL ROUGH IN DIMENSIONS ARE TO CENTER LINE OF DEVICE UNLESS OTHERWISE NOTED. 34, ALL PULL BOXES, HAND HOLES AND MAN HOLES TO HAVE COVER PLATE BOLTED TO FRAME AND BONDED TO THE EQUIPMENT GROUND SYSTEM. 35. CONTRACTOR SHALL INCLUDE IN HIS BID ALL COST RELATED TO THE WIND LOAD COMPLIANCE, THE CERTIFICATION OF THE EXTERIOR POLE/LUMINARY ASSEMBLIES BY A STRUCTURAL ENGINEER. 36. ALL CONDUCTOR SPLICES IN EXTERIOR LOCATED JUNCTION / PULL BOXES EXPOSED TO THE WEATHER TO ME WEATHER SEALED BY USING AN APPROVED METHOD SUCH AS 3M, SCOTHLOCK CONNECTOR EPDXY SEALING, PACK OR SIMILAR. 37. CONTRACTOR SHALL PROVIDE TEMPORARY PANEL, LIGHTS & OUTLETS THROUGHOUT THE BUILDING DURING COMPLETE CONSTRUCTION (ALL POWER MUST BE MADE TO SATISFY CONSULTANT NEEDS FOR ALL EQUIPMENT.) CI1'Y OF SOUT, !-1 I''S7V+i`.'Ii BUILDING DEPT. ELE:CTril(".AL. ST-CT10i,J APPROVE 3Y: _,_. __. __ DATE: , #26000522 ARCHITECTURE INTERIOR DESIGN PLANNING SEAL RONEY J. MATEU AR 0008220 JMM CONSULTING ENGINEERS, LLC M.E.P. 12651 S DIXIE HIGHWAY, SUITE 209 MIAMI, FLORIDA 33156 M.A. SUAREZ CONSULTING ENGINEERS STRUCTURAL ENGINEERING 4869 SW 75TH AVENUE MIAMI, FLORIDA 33155 PISTORIND & ALAM CONSULTING ENG, INC, CIVIL ENGINEERING 7171 SW 62ND AVENUE, 4TH FLOOR MIAMI, FLORIDA 33143 OXFORD UNIVERSAL 4311 PONCE DE LEON BLVD. CORAL GABLES, FLORIDA 33146 5966 SOUTH DIXIE BUILDING 5966 & 5970 SOUTH DIXIE HIGHWAY MIAMI, FLORIDA 33133 M A TE U ARCH ITECTURE INC. THIS DRAWING 15 THE PROPERTY OF MATEU ARCHITECTURE INC. UNLESS OTHERWISE PROVIDED FOR BY CONTRACT THE CONTENTS OF THIS DRAWING ARE CONFIDENTIAL AND SHALL NOT IE TRANSMITTED TO ANY PARTY EXCEPT AS AUTHORIZED BY THE ARCHITECT/ENGINEERS OF RECORD PHASE -AT. LT1j"Ififfla i FILE NAME: E -204 -DWG PROJECT NO MA0605 DRAWN NY: JMM CHECKED BY: JMM ISSUE DATE. DECEMBER 10, 2007 diH691U�169 SHEET TITLE NOTES & DETAILS SHEET- OF. E-204 19